Article Title: A monthly quality assurance procedure for 3D surface imaging
Article Snippet: Our department has installed the AlignRT system in two treatment rooms occupied by Elekta and Varian linear accelerators.

Imaging:

Article Title: SU-GG-T-267: Imaging Properties of the OCTOPUSTM-IQ Scanner in Combination with a New Polymer Gel Dosimeter
Article Snippet: In-vivo quantitative measurement of iron has been the focus of several studies related to iron disorders in the human body.. Techniques such as SQUID and MRI have been used to detect liver iron stores in patients afflicted with hemochromatosis and thalassemia.. Here we present a gammastimulated spectroscopy method to detect iron in an aqueous sample through nuclear resonance fluorescence.

Article Title: Three-dimensional surface and ultrasound imaging for daily IGRT of prostate cancer
Article Snippet: .. In this work, we compared daily setup variations observed by two IGRT modalities relying on surface imaging by AlignRT and trans-abdominal US by Clarity (Resonant Medical, Elekta, SE) in a cohort of patients treated for prostate cancer who underwent also regular quality assurance (QA) procedure by portal imaging. ..



Similar Products

90
Vision RT Ltd optical surface imaging (osi) systems alignrt
Optical Surface Imaging (Osi) Systems Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/surface+imaging+system+alignrt/optical+surface+monitoring+system+alignrt/pmc12149718-42-9-10
Average 90 stars, based on 1 article reviews
optical surface imaging (osi) systems alignrt - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Vision RT Ltd optical surface imaging systems alignrt
Optical Surface Imaging Systems Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/surface+imaging+system+alignrt/optical+surface+monitoring+system+alignrt/pm40123313-23-3-10
Average 90 stars, based on 1 article reviews
optical surface imaging systems alignrt - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Respiratory Motion catalyst, alignrt, identify surface imaging system
Catalyst, Alignrt, Identify Surface Imaging System, supplied by Respiratory Motion, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/surface+imaging+system+alignrt/catalyst++alignrt++identify+surface+imaging+system/pmc11969100-60-1-11
Average 90 stars, based on 1 article reviews
catalyst, alignrt, identify surface imaging system - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Vision RT Ltd surface-guided imaging alignrt version 6.3.2
Surface Guided Imaging Alignrt Version 6.3.2, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/surface+imaging+system+alignrt/controlled+surface+monitoring+technique+alignrt/pm39098107-50-20-23
Average 90 stars, based on 1 article reviews
surface-guided imaging alignrt version 6.3.2 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Vision RT Ltd optical surface-guided imaging visionrt–alignrt
Optical Surface Guided Imaging Visionrt–Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/surface+imaging+system+alignrt/3+camera+align+rt+system/pmc11204472-63-12-13
Average 90 stars, based on 1 article reviews
optical surface-guided imaging visionrt–alignrt - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Vision RT Ltd surface scanning imaging alignrt
Surface Scanning Imaging Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/surface+imaging+system+alignrt/controlled+surface+monitoring+technique+alignrt/pm38492672-77-5-9
Average 90 stars, based on 1 article reviews
surface scanning imaging alignrt - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Vision RT Ltd surface imaging system alignrt
Surface Imaging System Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/surface+imaging+system+alignrt/alignrt+surface+imaging+system/pmc10646616-142-10-14
Average 90 stars, based on 1 article reviews
surface imaging system alignrt - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Vision RT Ltd on-board cbct imaging and surface guidance from alignrt
Surface‐guided radiation therapy (SGRT) setup registration. Left: The surface used for treatment setup by the <t>AlignRT</t> system. Middle: Recreation of the surface surveyed by the AlignRT system using a manually generated chest surface contour (shown in white) on the quality assurance CT (QA‐CT). Right: Fusion image from the planning CT and the QA‐CT after performing an automatic image registration focusing on the chest surface contour only
On Board Cbct Imaging And Surface Guidance From Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/surface+imaging+system+alignrt/linear+accelerator+equipped+with+a+real+time+3d+surface+imaging+system+alignrt/pmc08425866-49-12-13
Average 90 stars, based on 1 article reviews
on-board cbct imaging and surface guidance from alignrt - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Vision RT Ltd alignrt surface imaging system
Surface‐guided radiation therapy (SGRT) setup registration. Left: The surface used for treatment setup by the <t>AlignRT</t> system. Middle: Recreation of the surface surveyed by the AlignRT system using a manually generated chest surface contour (shown in white) on the quality assurance CT (QA‐CT). Right: Fusion image from the planning CT and the QA‐CT after performing an automatic image registration focusing on the chest surface contour only
Alignrt Surface Imaging System, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/surface+imaging+system+alignrt/alignrt+surface+imaging+system/pmc08279697-23-9-5
Average 90 stars, based on 1 article reviews
alignrt surface imaging system - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Vision RT Ltd optical 3d surface imaging system alignrt
Statistical summary of the <t> AlignRT </t> mean and max magnitude readouts of a phantom.
Optical 3d Surface Imaging System Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/surface+imaging+system+alignrt/3d+surface+imaging+system+alignrt/pmc07484878-53-11-12
Average 90 stars, based on 1 article reviews
optical 3d surface imaging system alignrt - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Surface‐guided radiation therapy (SGRT) setup registration. Left: The surface used for treatment setup by the AlignRT system. Middle: Recreation of the surface surveyed by the AlignRT system using a manually generated chest surface contour (shown in white) on the quality assurance CT (QA‐CT). Right: Fusion image from the planning CT and the QA‐CT after performing an automatic image registration focusing on the chest surface contour only

Journal: Journal of Applied Clinical Medical Physics

Article Title: Comparison of the dosimetric accuracy of proton breast treatment plans delivered with SGRT and CBCT setups

doi: 10.1002/acm2.13357

Figure Lengend Snippet: Surface‐guided radiation therapy (SGRT) setup registration. Left: The surface used for treatment setup by the AlignRT system. Middle: Recreation of the surface surveyed by the AlignRT system using a manually generated chest surface contour (shown in white) on the quality assurance CT (QA‐CT). Right: Fusion image from the planning CT and the QA‐CT after performing an automatic image registration focusing on the chest surface contour only

Article Snippet: The patient was setup with on‐board CBCT imaging and surface guidance from AlignRT (VisionRT Ltd.) for the first three fractions.

Techniques: Generated

Statistical summary of the  AlignRT  mean and max magnitude readouts of a phantom.

Journal: Journal of Applied Clinical Medical Physics

Article Title: Validating robotic couch isocentricity with 3D surface imaging

doi: 10.1002/acm2.12939

Figure Lengend Snippet: Statistical summary of the AlignRT mean and max magnitude readouts of a phantom.

Article Snippet: The accuracy of a commercially available optical 3D surface imaging system, AlignRT (VisionRT Ltd., London UK) has been shown by several studies to be within 1 mm., Here we investigate sensitivity and specificity of a surface imaging system for identifying excessive mechanical runout in a robotic couch rotation.

Techniques:

Statistical summary of the  AlignRT  mean and max magnitude readouts of volunteers.

Journal: Journal of Applied Clinical Medical Physics

Article Title: Validating robotic couch isocentricity with 3D surface imaging

doi: 10.1002/acm2.12939

Figure Lengend Snippet: Statistical summary of the AlignRT mean and max magnitude readouts of volunteers.

Article Snippet: The accuracy of a commercially available optical 3D surface imaging system, AlignRT (VisionRT Ltd., London UK) has been shown by several studies to be within 1 mm., Here we investigate sensitivity and specificity of a surface imaging system for identifying excessive mechanical runout in a robotic couch rotation.

Techniques:

A distribution of the reported deviation magnitude for AlignRT following 0, 0.2, 0.4, 0.6, and 0.8 cm shifts from isocenter, in conjunction with a 90° rotation. Upper and lower panels represent the results from immobilized and nonimmobilized volunteers respectively.

Journal: Journal of Applied Clinical Medical Physics

Article Title: Validating robotic couch isocentricity with 3D surface imaging

doi: 10.1002/acm2.12939

Figure Lengend Snippet: A distribution of the reported deviation magnitude for AlignRT following 0, 0.2, 0.4, 0.6, and 0.8 cm shifts from isocenter, in conjunction with a 90° rotation. Upper and lower panels represent the results from immobilized and nonimmobilized volunteers respectively.

Article Snippet: The accuracy of a commercially available optical 3D surface imaging system, AlignRT (VisionRT Ltd., London UK) has been shown by several studies to be within 1 mm., Here we investigate sensitivity and specificity of a surface imaging system for identifying excessive mechanical runout in a robotic couch rotation.

Techniques:

Represents the number of true/false positives and true/false negatives for detecting couch runouts ≥2 mm using a 2 mm action level on the  AlignRT  displacement vector.

Journal: Journal of Applied Clinical Medical Physics

Article Title: Validating robotic couch isocentricity with 3D surface imaging

doi: 10.1002/acm2.12939

Figure Lengend Snippet: Represents the number of true/false positives and true/false negatives for detecting couch runouts ≥2 mm using a 2 mm action level on the AlignRT displacement vector.

Article Snippet: The accuracy of a commercially available optical 3D surface imaging system, AlignRT (VisionRT Ltd., London UK) has been shown by several studies to be within 1 mm., Here we investigate sensitivity and specificity of a surface imaging system for identifying excessive mechanical runout in a robotic couch rotation.

Techniques: Plasmid Preparation

Represents the number of true/false positives and true/false negatives for detecting couch runouts ≥4 mm using a 4 mm action level on the  AlignRT  displacement vector.

Journal: Journal of Applied Clinical Medical Physics

Article Title: Validating robotic couch isocentricity with 3D surface imaging

doi: 10.1002/acm2.12939

Figure Lengend Snippet: Represents the number of true/false positives and true/false negatives for detecting couch runouts ≥4 mm using a 4 mm action level on the AlignRT displacement vector.

Article Snippet: The accuracy of a commercially available optical 3D surface imaging system, AlignRT (VisionRT Ltd., London UK) has been shown by several studies to be within 1 mm., Here we investigate sensitivity and specificity of a surface imaging system for identifying excessive mechanical runout in a robotic couch rotation.

Techniques: Plasmid Preparation