Review




Structured Review

HEKA Elektronik patchmaster software
Patchmaster Software, supplied by HEKA Elektronik, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/software+(heka+patchmaster)/patchmaster+software/10__1074_slash_jbc__m116__723932-78-7-9
Average 90 stars, based on 1 article reviews
patchmaster software - by Bioz Stars, 2026-10
90/100 stars

Images

Related Articles

Patch Clamp:

Article Title: Type I TARPs regulate Kv7.2 potassium channels and susceptibility to seizures
Article Snippet: Patch pipette electrodes (4–6 mΩ) made from borosilicate glass (Science Products, #GB150F-8P) were pulled with a horizontal microelectrode puller (P-97 Flaming/Brown type micropipette puller, Sutter Instruments), and filled with a K-gluconate-based solution (122 mM K-gluconate, 20 mM KCl, 20 mM HEPES, 13.6 mM NaCl, 3 mM Mg 2+ -ATP, 1 mM EGTA, 0.2 mM CaCl 2 , pH 7.3 adjusted with KOH, 295-300 mOsm). .. Both voltage- and current-clamp recordings were performed using an EPC 10 USB patch-clamp amplifier (HEKA Elektronik), low-pass filtered at 2.9 kHz using a built-in Bessel filter and digitized at 25 kHz with PATCHMASTER software (HEKA Elektronik). ..

Article Title: Cerebellar systems consolidation driven by the temporal dynamics of Purkinje cell excitability
Article Snippet: .. Electrophysiological data were acquired using an EPC9 patch-clamp amplifier (HEKA Elektronik) and PatchMaster software (HEKA Elektronik) at a sampling frequency of 20 kHz, and the signals were filtered at 2 kHz. ..

Article Title: Differential potassium channel inhibitory activities of a novel thermostable degradation peptide BmKcug1a-P1 from scorpion medicinal material and its N-terminal truncated/restored peptides
Article Snippet: .. An EPC-10 patch-clamp amplifier which was controlled by PatchMaster software (HEKA Elektronik, Lambrecht, Germany) was applied to measure and record the potassium currents for whole-cell. .. The MPS-2 multichannel microperfusion system (INBIO Inc., Wuhan, China) was applied to exchange the external bath solution with different concentration of peptides.

Software:

Article Title: Type I TARPs regulate Kv7.2 potassium channels and susceptibility to seizures
Article Snippet: Patch pipette electrodes (4–6 mΩ) made from borosilicate glass (Science Products, #GB150F-8P) were pulled with a horizontal microelectrode puller (P-97 Flaming/Brown type micropipette puller, Sutter Instruments), and filled with a K-gluconate-based solution (122 mM K-gluconate, 20 mM KCl, 20 mM HEPES, 13.6 mM NaCl, 3 mM Mg 2+ -ATP, 1 mM EGTA, 0.2 mM CaCl 2 , pH 7.3 adjusted with KOH, 295-300 mOsm). .. Both voltage- and current-clamp recordings were performed using an EPC 10 USB patch-clamp amplifier (HEKA Elektronik), low-pass filtered at 2.9 kHz using a built-in Bessel filter and digitized at 25 kHz with PATCHMASTER software (HEKA Elektronik). ..

Article Title: Functional properties of a disease mutation for migraine in Kv2.1/6.4 channels.
Article Snippet: .. For data acquisition and preliminary analysis, we employed Patchmaster software (HEKA Elektronik GmbH, Reutlingen, Germany). ..

Article Title: A novel KCND3 variant in the N‐terminus impairs the ionic current of Kv4.3 and is associated with SCA19 /22
Article Snippet: .. Whole‐cell recordings were performed with a EPC10 USB amplifier controlled by the PatchMaster Software (HEKA Elektronik GmbH, Reutlingen). .. The patch electrodes were pulled from 1.0 mm borosilicate capillary glass (Science Products GmbH, Hofheim) using a P2000 pipette puller (Sutter Instruments, Novato, CA).

Article Title: Type I TARPs regulate Kv7.2 potassium channels and susceptibility to seizures
Article Snippet: All recordings were analyzed using pCLAMP v10.7 (Axon Instruments, Molecular Devices). .. Data acquired with the PATCHMASTER software (HEKA Elektronik) were converted to ABF file format before analyses. ..

Article Title: Cerebellar systems consolidation driven by the temporal dynamics of Purkinje cell excitability
Article Snippet: .. Electrophysiological data were acquired using an EPC9 patch-clamp amplifier (HEKA Elektronik) and PatchMaster software (HEKA Elektronik) at a sampling frequency of 20 kHz, and the signals were filtered at 2 kHz. ..

Article Title: Differential potassium channel inhibitory activities of a novel thermostable degradation peptide BmKcug1a-P1 from scorpion medicinal material and its N-terminal truncated/restored peptides
Article Snippet: .. An EPC-10 patch-clamp amplifier which was controlled by PatchMaster software (HEKA Elektronik, Lambrecht, Germany) was applied to measure and record the potassium currents for whole-cell. .. The MPS-2 multichannel microperfusion system (INBIO Inc., Wuhan, China) was applied to exchange the external bath solution with different concentration of peptides.

Article Title: Functional properties of a disease mutation for migraine in Kv2.1/6.4 channels
Article Snippet: .. For data acquisition and preliminary analysis, we employed Patchmaster software (HEKA Elektronik GmbH, Reutlingen, Germany). ..

Article Title: Neuropeptidergic regulation of neuromuscular signaling in larval zebrafish alters swimming behavior and synaptic transmission
Article Snippet: Patch-clamp recordings were performed at room temperature using an EPC-10 amplifier (HEKA Elektronik, Germany). .. Data were acquired using the Patchmaster software (HEKA Elektronik, Germany) at a holding potential of −60 mV and filtered at 2.9 kHz bPAC photostimulation was performed using a KSL-70 LED light (Rapp Optoelectronics, 470 nm), triggered by the Patchmaster software. ..

Sampling:

Article Title: Cerebellar systems consolidation driven by the temporal dynamics of Purkinje cell excitability
Article Snippet: .. Electrophysiological data were acquired using an EPC9 patch-clamp amplifier (HEKA Elektronik) and PatchMaster software (HEKA Elektronik) at a sampling frequency of 20 kHz, and the signals were filtered at 2 kHz. ..



Similar Products

90
HEKA Electronics Incorporated patchmaster software with heka epc10
Patchmaster Software With Heka Epc10, supplied by HEKA Electronics Incorporated, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/software+(heka+patchmaster)/epc+10+amplifier/us12303496-590-7-9
Average 90 stars, based on 1 article reviews
patchmaster software with heka epc10 - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
HEKA Electronics Incorporated patchmaster software (heka)
Patchmaster Software (Heka), supplied by HEKA Electronics Incorporated, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/software+(heka+patchmaster)/patchmaster+software/bio_rxiv__2025__01__23__634330-113-11-7
Average 90 stars, based on 1 article reviews
patchmaster software (heka) - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

99
Danaher Inc patchmaster software heka
Patchmaster Software Heka, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/software+(heka+patchmaster)/MultiClamp+700B+current+%26+patch+clamp+amplifier/pmc11733414-109-22-33
Average 99 stars, based on 1 article reviews
patchmaster software heka - by Bioz Stars, 2026-10
99/100 stars
  Buy from Supplier

90
HEKA Electronics Incorporated heka patchmaster 2.65 software
Heka Patchmaster 2.65 Software, supplied by HEKA Electronics Incorporated, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/software+(heka+patchmaster)/heka+patchmaster/pm39566665-111-41-45
Average 90 stars, based on 1 article reviews
heka patchmaster 2.65 software - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

99
Danaher Inc patchmaster 1 2 software heka
Patchmaster 1 2 Software Heka, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/software+(heka+patchmaster)/MultiClamp+700B+current+%26+patch+clamp+amplifier/10__1134_slash_s0022093024060140-52-18-28
Average 99 stars, based on 1 article reviews
patchmaster 1 2 software heka - by Bioz Stars, 2026-10
99/100 stars
  Buy from Supplier

90
HEKA Elektronik heka patchmaster software
Reagents and tools table
Heka Patchmaster Software, supplied by HEKA Elektronik, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/software+(heka+patchmaster)/heka+patchmaster+software/pmc11148119-449-0-9
Average 90 stars, based on 1 article reviews
heka patchmaster software - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
HEKA Elektronik heka’s patchmaster software
Reagents and tools table
Heka’s Patchmaster Software, supplied by HEKA Elektronik, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/software+(heka+patchmaster)/heka+patchmaster+software/bio_rxiv__2024__01__08__574608-181-9-4
Average 90 stars, based on 1 article reviews
heka’s patchmaster software - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results


Reagents and tools table

Journal: The EMBO Journal

Article Title: Functional and structural insights into activation of TRPV2 by weak acids

doi: 10.1038/s44318-024-00106-4

Figure Lengend Snippet: Reagents and tools table

Article Snippet: HEKA Patchmaster software and EPC 10 USB HEKA amplifier (HEKA Elektronik, Lamprecht, Germany) were used for patch clamp recordings.

Techniques: Recombinant, Purification, Plasmid Preparation, Sequencing, Protease Inhibitor, Transfection, Modification, Software, Transformation Assay, Mutagenesis