Review




Structured Review

Decon Laboratories saf signal processing algorithm
Simulated waveforms at four different levels of local distortion parameter, σq, before (left column) and after (right column) accounting for <t>spatial</t> <t>averaging</t> effects due to reception by a membrane hydrophone with a geometrical sensitive element diameter of 500 μm (by application of the <t>SAF).</t> The source has a center frequency of 5 mHz, diameter of 19 mm, and a focal length of 38 mm. The nonlinearity index values were σq = 0.6, σm = 0.5, SI = 0.06 (top row), σq = 1.0, σm = 0.8, SI = 0.11 (second row), σq = 2.3, σm = 1.9, SI = 0.32 (third row), and σq = 4.6, σm = 3.9, SI = 0.45 (fourth row).
Saf Signal Processing Algorithm, supplied by Decon Laboratories, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/signal+processing+algorithms/saf+signal+processing+algorithm/pmc08325168-367-4-5
Average 90 stars, based on 1 article reviews
saf signal processing algorithm - by Bioz Stars, 2026-11
90/100 stars

Images

1) Product Images from "Correction for Hydrophone Spatial Averaging Artifacts for Circular Sources"

Article Title: Correction for Hydrophone Spatial Averaging Artifacts for Circular Sources

Journal: IEEE transactions on ultrasonics, ferroelectrics, and frequency control

doi: 10.1109/TUFFC.2020.3007808

Simulated waveforms at four different levels of local distortion parameter, σq, before (left column) and after (right column) accounting for spatial averaging effects due to reception by a membrane hydrophone with a geometrical sensitive element diameter of 500 μm (by application of the SAF). The source has a center frequency of 5 mHz, diameter of 19 mm, and a focal length of 38 mm. The nonlinearity index values were σq = 0.6, σm = 0.5, SI = 0.06 (top row), σq = 1.0, σm = 0.8, SI = 0.11 (second row), σq = 2.3, σm = 1.9, SI = 0.32 (third row), and σq = 4.6, σm = 3.9, SI = 0.45 (fourth row).
Figure Legend Snippet: Simulated waveforms at four different levels of local distortion parameter, σq, before (left column) and after (right column) accounting for spatial averaging effects due to reception by a membrane hydrophone with a geometrical sensitive element diameter of 500 μm (by application of the SAF). The source has a center frequency of 5 mHz, diameter of 19 mm, and a focal length of 38 mm. The nonlinearity index values were σq = 0.6, σm = 0.5, SI = 0.06 (top row), σq = 1.0, σm = 0.8, SI = 0.11 (second row), σq = 2.3, σm = 1.9, SI = 0.32 (third row), and σq = 4.6, σm = 3.9, SI = 0.45 (fourth row).

Techniques Used: Membrane

Effects of spatial averaging on measurements of peak compressional pressure (pc), peak rarefactional pressure (pr), and pulse intensity integral for the 25 transducer/hydrophone combinations. The plots show: 1) raw data (“Raw RF”); 2) data deconvolved for hydrophone sensitivity only (“Decon Sens”); and 3) data deconvolved for hydrophone sensitivity and inverse filtered using Sp(nf1) over all harmonics with sufficient SNR (see Fig. 8) (“Decons Sens + SAF”). Data are plotted as a function of hydrophone nominal geometric sensitive element diameter, dg. Error bars (which are so small they are difficult to discern) denote standard deviations. Linear and exponential fits to data are also shown.
Figure Legend Snippet: Effects of spatial averaging on measurements of peak compressional pressure (pc), peak rarefactional pressure (pr), and pulse intensity integral for the 25 transducer/hydrophone combinations. The plots show: 1) raw data (“Raw RF”); 2) data deconvolved for hydrophone sensitivity only (“Decon Sens”); and 3) data deconvolved for hydrophone sensitivity and inverse filtered using Sp(nf1) over all harmonics with sufficient SNR (see Fig. 8) (“Decons Sens + SAF”). Data are plotted as a function of hydrophone nominal geometric sensitive element diameter, dg. Error bars (which are so small they are difficult to discern) denote standard deviations. Linear and exponential fits to data are also shown.

Techniques Used:

Membrane hydrophone simulation results (open circles and squares) for percent error in estimates of peak compressional pressure (pc), peak rarefactional pressure (pr), and pulse intensity integral, when: 1) no spatial averaging correction is applied (“Without SAF”) and 2) the full SAF inverse filter correction is applied (“With SAF”). Measurements are shown in asterisks and x’s. All simulation and experimental data were inverse filtered to deconvolve the effects of hydrophone frequency-dependent sensitivity. Simulation data without SAF are fit to functions of the form – 100% × [1 − exp(−αx)], where x = dg/(λ1F#) and α is a fitting parameter. Standard deviations for measurements are less than 1%.
Figure Legend Snippet: Membrane hydrophone simulation results (open circles and squares) for percent error in estimates of peak compressional pressure (pc), peak rarefactional pressure (pr), and pulse intensity integral, when: 1) no spatial averaging correction is applied (“Without SAF”) and 2) the full SAF inverse filter correction is applied (“With SAF”). Measurements are shown in asterisks and x’s. All simulation and experimental data were inverse filtered to deconvolve the effects of hydrophone frequency-dependent sensitivity. Simulation data without SAF are fit to functions of the form – 100% × [1 − exp(−αx)], where x = dg/(λ1F#) and α is a fitting parameter. Standard deviations for measurements are less than 1%.

Techniques Used: Membrane

Needle/fiber optic hydrophone simulation results (open circles and squares) for percent error in estimates of peak compressional pressure (pc), peak rarefactional pressure (pr), and pulse intensity integral, when: 1) no spatial averaging correction is applied (“Without SAF”) and 2) the full SAF inverse filter correction is applied (“With SAF”). All simulation data were inverse filtered to deconvolve the effects of hydrophone frequency-dependent sensitivity. Simulation data without SAF are fit to functions of the form −100% × [1 − exp(−βx2)], where x = dg/(λ1F#) and β is a fitting parameter.
Figure Legend Snippet: Needle/fiber optic hydrophone simulation results (open circles and squares) for percent error in estimates of peak compressional pressure (pc), peak rarefactional pressure (pr), and pulse intensity integral, when: 1) no spatial averaging correction is applied (“Without SAF”) and 2) the full SAF inverse filter correction is applied (“With SAF”). All simulation data were inverse filtered to deconvolve the effects of hydrophone frequency-dependent sensitivity. Simulation data without SAF are fit to functions of the form −100% × [1 − exp(−βx2)], where x = dg/(λ1F#) and β is a fitting parameter.

Techniques Used:

Related Articles

other:

Article Title: Correction for Hydrophone Spatial Averaging Artifacts for Circular Sources
Article Snippet: Inverse filtering with the SAF (“Decon Sens + SAF”) significantly suppresses spatial averaging effects. shows that measurements made with the high-resolution HGL-0085 hydrophone ( d g = 85 μ m) that were not corrected for spatial averaging (“Raw RF” or “Decon Sens”) were consistent with the trends of measurements made with the membrane hydrophones that were corrected for spatial averaging (“Decon Sens + SAF”).



Similar Products

90
MathWorks Inc synthetic aperture radar signal processing with matlab algorithms
Synthetic Aperture Radar Signal Processing With Matlab Algorithms, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/signal+processing+algorithms/pm40608988-312-18-23
Average 90 stars, based on 1 article reviews
synthetic aperture radar signal processing with matlab algorithms - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
MathWorks Inc matlab-based signal processing algorithm
Matlab Based Signal Processing Algorithm, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/signal+processing+algorithms/pm40178030-62-1-1
Average 90 stars, based on 1 article reviews
matlab-based signal processing algorithm - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

98
MathWorks Inc findpeaks algorithm
Findpeaks Algorithm, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/signal+processing+algorithms/Signal+Processing+Toolbox/10__1109_slash_tnsre__2025__3537333-127-6-14
Average 98 stars, based on 1 article reviews
findpeaks algorithm - by Bioz Stars, 2026-11
98/100 stars
  Buy from Supplier

90
Routledge Ltd digital signal processing algorithms: number theory, convolution, fast fourier transforms, and applications
Digital Signal Processing Algorithms: Number Theory, Convolution, Fast Fourier Transforms, And Applications, supplied by Routledge Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/signal+processing+algorithms/digital+signal+processing+algorithms++number+theory++convolution++fast+fourier+transforms++and+applications/pm39705217-364-13-19
Average 90 stars, based on 1 article reviews
digital signal processing algorithms: number theory, convolution, fast fourier transforms, and applications - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
MathWorks Inc signal processing techniques-based pan tompkins algorithm
Signal Processing Techniques Based Pan Tompkins Algorithm, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/signal+processing+algorithms/10__1007_slash_s42979___024___03456___2-139-18-28
Average 90 stars, based on 1 article reviews
signal processing techniques-based pan tompkins algorithm - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
MathWorks Inc raman signal processing algorithm using weiner estimation method
Raman Signal Processing Algorithm Using Weiner Estimation Method, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/signal+processing+algorithms/pm39382540__am4c12322_si_001-41-7-22
Average 90 stars, based on 1 article reviews
raman signal processing algorithm using weiner estimation method - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Tekran Inc hg signal processing algorithms for the tekran 2537 analyzer
Hg Signal Processing Algorithms For The Tekran 2537 Analyzer, supplied by Tekran Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/signal+processing+algorithms/tekran+2537+analyzer/pm39122272-11-8-8
Average 90 stars, based on 1 article reviews
hg signal processing algorithms for the tekran 2537 analyzer - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Synopsys Inc spw signal processing algorithm tool
Spw Signal Processing Algorithm Tool, supplied by Synopsys Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/signal+processing+algorithms/spw+signal+processing+algorithm+tool/us12045737-837-158-164
Average 90 stars, based on 1 article reviews
spw signal processing algorithm tool - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
MathWorks Inc signal-processing algorithm
Signal Processing Algorithm, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/signal+processing+algorithms/pm38867338-85-1-13
Average 90 stars, based on 1 article reviews
signal-processing algorithm - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results