Review




Structured Review

COMSOL Inc laminar flow module
Laminar Flow Module, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/reaction-diffusion+comsol+module/laminar+flow+module/pm38968774-87-25-33
Average 90 stars, based on 1 article reviews
laminar flow module - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

other:

Article Title: Electrohydrodynamic Vortex Imaging: A New Tool for Understanding Mass Transfer in Surface-Based Biosensors.
Article Snippet: This velocity was then imposed as a boundary condition at the electrode surface to estimate fluid motion by solving Navier– Stokes equations using COMSOL Laminar flow module, assuming that the fluid was incompressible.

Article Title: Electrohydrodynamic Vortex Imaging: A New Tool for Understanding Mass Transfer in Surface-Based Biosensors.
Article Snippet: The particles were subjected to drag (based on the velocity obtained from the laminar flow module) and DEP forces, which are both implemented in COMSOL.

Membrane:

Article Title: Microfluidic system for efficient molecular delivery to artificial cell membranes.
Article Snippet: .. The laminar flow in the channels was modelled using the laminar flow module in COMSOL.15,16,34,35 In the first simulations, the pump connected to inlet 1 was run as done when membranes are formed (Fig. 2C) with an inlet flow rate of 5 μl min−1.30 It is crucial that the flow remains symmetric at the gaps to ensure that flat membranes form without any significant warping that may lead to membrane rupture. ..

Software:

Article Title: Study on the diffusion mechanism of gangue slurry within the rough connected voids in the caving zone.
Article Snippet: .. Utilizing the laminar flow module within the COMSOL Multiphysics software, the N-S equations are employed to compute the gangue slurry flow, while the level set method is utilized to trace the gangue slurry diffusion interface. ..

Article Title: Multienergy Codriven Electron Transfer Across the Nano-Bio Interface for Efficient Photobiocatalysis.
Article Snippet: Integrating biocatalysis with nanophotocatalysis provides a promising pathway to address the knotty environmental and energy problems.. However, energy loss during the transfer of extracellular electrons across the nano-bio interface seriously limits the efficiency of whole-cellbased photobiocatalytic systems.. Herein, we demonstrate an integrated multienergy codriven reaction platform containing BaTiO3 nanoparticles (BTO) for harvesting mechanical energy from flowing water to elevate the interfacial electric field, BiVO4 quantum dots (BQD) for harvesting light energy to generate photocarriers, and Geobacter sulfurreducens (GS) for accepting photoelectrons to accomplish the biocatalytic reactions.

Diffusion-based Assay:

Article Title: Study on the diffusion mechanism of gangue slurry within the rough connected voids in the caving zone.
Article Snippet: .. Utilizing the laminar flow module within the COMSOL Multiphysics software, the N-S equations are employed to compute the gangue slurry flow, while the level set method is utilized to trace the gangue slurry diffusion interface. ..

Article Title: Computational modeling of necrosis in neural organoids
Article Snippet: .. We coupled our diffusion-reaction model from the static state model with the Laminar flow module in COMSOL to simulate the convective transport of oxygen in the media during dynamic culture using orbital shaking and microfluidic flow around and within the NO. Due to the high cellular density of the NO, we assumed convective transport of O 2 within it to be negligible, and primarily occurring via diffusion. ..

Analysis:

Article Title: A microfluidic device for passive separation of platelet-rich plasma from whole blood.
Article Snippet: We present a microfluidic device for separating platelet-rich plasma (PRP) from whole blood, addressing key limitations in current sedimentation-based technologies.. Unlike existing methods that rely on a single sedimentation trench—limiting plasma yield and processing speed—our device incorporates a novel multitrench design, allowing the processing of 1 mL of whole blood in 40 minutes, yielding ∼250 μL of PRP with at least a 2-fold increase in platelet concentration.. The device is fabricated using a CO2 laser cutter on acrylic layers and bonded with a pressure-sensitive adhesives, offering a cost-effective and simple alternative to more complex manufacturing processes.

Flow Cytometry:

Article Title: A microfluidic device for passive separation of platelet-rich plasma from whole blood.
Article Snippet: We present a microfluidic device for separating platelet-rich plasma (PRP) from whole blood, addressing key limitations in current sedimentation-based technologies.. Unlike existing methods that rely on a single sedimentation trench—limiting plasma yield and processing speed—our device incorporates a novel multitrench design, allowing the processing of 1 mL of whole blood in 40 minutes, yielding ∼250 μL of PRP with at least a 2-fold increase in platelet concentration.. The device is fabricated using a CO2 laser cutter on acrylic layers and bonded with a pressure-sensitive adhesives, offering a cost-effective and simple alternative to more complex manufacturing processes.

Viscosity:

Article Title: A microfluidic device for passive separation of platelet-rich plasma from whole blood.
Article Snippet: We present a microfluidic device for separating platelet-rich plasma (PRP) from whole blood, addressing key limitations in current sedimentation-based technologies.. Unlike existing methods that rely on a single sedimentation trench—limiting plasma yield and processing speed—our device incorporates a novel multitrench design, allowing the processing of 1 mL of whole blood in 40 minutes, yielding ∼250 μL of PRP with at least a 2-fold increase in platelet concentration.. The device is fabricated using a CO2 laser cutter on acrylic layers and bonded with a pressure-sensitive adhesives, offering a cost-effective and simple alternative to more complex manufacturing processes.

Shear:

Article Title: A microfluidic device for passive separation of platelet-rich plasma from whole blood.
Article Snippet: We present a microfluidic device for separating platelet-rich plasma (PRP) from whole blood, addressing key limitations in current sedimentation-based technologies.. Unlike existing methods that rely on a single sedimentation trench—limiting plasma yield and processing speed—our device incorporates a novel multitrench design, allowing the processing of 1 mL of whole blood in 40 minutes, yielding ∼250 μL of PRP with at least a 2-fold increase in platelet concentration.. The device is fabricated using a CO2 laser cutter on acrylic layers and bonded with a pressure-sensitive adhesives, offering a cost-effective and simple alternative to more complex manufacturing processes.

Evaporation:

Article Title: Volatile liquid analysis
Article Snippet: .. A “Laminar Fluid Flow” module was also added in COMSOL to allow for the consideration of vapor pressure gradients that form due to the initial evaporation of the sample by means of solving the Navier-Stokes equations. ..



Similar Products

90
COMSOL Inc reaction-diffusion comsol module
Reaction Diffusion Comsol Module, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/reaction-diffusion+comsol+module/diffusion+module/pmc04293228-76-1-2
Average 90 stars, based on 1 article reviews
reaction-diffusion comsol module - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results