Review



eeg data preprocessing and analysis software  (Brainvision Inc)

 
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Brainvision Inc eeg data preprocessing and analysis software
    Erotica-induced modulation of NFR, pain, N2 and P2 in studies 2 and 3.
    Eeg Data Preprocessing And Analysis Software, supplied by Brainvision Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/preprocessed+eeg+data/brainvision+analyzer2/pmc11925531-225-7-15
    Average 90 stars, based on 1 article reviews
    eeg data preprocessing and analysis software - by Bioz Stars, 2026-11
    90/100 stars

    Images

    1) Product Images from "Cerebral peak alpha frequency: Associations with chronic pain onset and pain modulation"

    Article Title: Cerebral peak alpha frequency: Associations with chronic pain onset and pain modulation

    Journal: Neurobiology of Pain

    doi: 10.1016/j.ynpai.2025.100180

    Erotica-induced modulation of NFR, pain, N2 and P2 in studies 2 and 3.
    Figure Legend Snippet: Erotica-induced modulation of NFR, pain, N2 and P2 in studies 2 and 3.

    Techniques Used:

    Mutilation-induced modulation of NFR, pain, N2 and P2 in studies 2 & 3.
    Figure Legend Snippet: Mutilation-induced modulation of NFR, pain, N2 and P2 in studies 2 & 3.

    Techniques Used:

    Grand average EEG waveforms at Cz for ECON. Time windows used for analysis of N2 (90–140 ms) and P2 (280–350 ms) are shaded.
    Figure Legend Snippet: Grand average EEG waveforms at Cz for ECON. Time windows used for analysis of N2 (90–140 ms) and P2 (280–350 ms) are shaded.

    Techniques Used:

    Related Articles

    other:

    Article Title: Sleep Dependent Changes of Lactate Concentration in Human Brain
    Article Snippet: PSG measurements were continuously recorded with a sampling frequency of 5 kHz using BrainVision Recorder software, and temporally registered with 1 H-MRS time-series using time-stamps - generated by the MR instrument and recorded with PSG.

    Article Title: Abstracts of the 25th Congress of the European Sleep Research Society, 22-24 September 2020, Virtual Congress.
    Article Snippet: We analyzed data in BrainVision Analyzer2.0 and conducted clusterbased permutation statistics for global effect (GD minus GS) after the onset of the fifth sound in FieldTrip, MatlabR2019a.

    Article Title: Cerebral peak alpha frequency: Associations with chronic pain onset and pain modulation
    Article Snippet: For analysis of PEPs during CPM and ECON, EEG data were preprocessed and analyzed in BrainVision Analyzer Software (Version 2.1.2.327).

    Article Title: Brain signatures indexing variation in internal processing during perceptual decision-making
    Article Snippet: EEG recording and analysis EEG was acquired from 64 active electrodes (BrainVision ActiChamp), with each impedance kept below 30kΩ.

    Article Title: Forensic Study on Objective Evaluation of Visual Acuity of Ametropia with the Event-related Potential P3.
    Article Snippet: Fu-quan JIA1, Fang-liang LUO2, Yan-he XIONG3, Long-long CHENG4, Zhi-qiang DANG5, Ji-hui LIU2# Department of Forensic Medicine, Inner Mongolia Medical University, Hohhot 010059, China Judicial Authentication Research Institute, Liaoning University, Shenyang 110036, China Shanghai Love Nursing Station, Shanghai 200030, China Affiliated Zhongshan Hospital of Dalian University, Dalian 116001, China Dian Regional Forensic Science Institute (Nei Mongol), Hohhot 010041, China

    Article Title: A Case Study on EEG Signal Correlation Towards Potential Epileptic Foci Triangulation
    Article Snippet: Using BRAINVISION professional ANALYZER2.1 ® software, the impedance of the electrodes on the coupled EEG cap was checked to determine if it was below the usual standard of 15 kOhm at 1 kHz.

    Comparison:

    Article Title: Posttraumatic stress symptomatology rather than mild traumatic brain injury is related to atypical early neural processing during cognitive control.
    Article Snippet: Neuropsychology Posttraumatic Stress Symptomatology Rather Than Mild Traumatic Brain Injury Is Related to Atypical Early Neural Processing During Cognitive Control Kara L. Stevens, Craig A. Marquardt, Matthew A. Tong, Nicholas D. Davenport, and Scott R. Sponheim Online First Publication, April 7, 2025. https://dx.doi.org/10.1037/neu0001008 CITATION Stevens, K. L., Marquardt, C. A., Tong, M. A., Davenport, N. D., & Sponheim, S. R. (2025).. Posttraumatic stress symptomatology rather than mild traumatic brain injury is related to atypical early neural processing during cognitive control.. Neuropsychology.

    Software:

    Article Title: Posttraumatic stress symptomatology rather than mild traumatic brain injury is related to atypical early neural processing during cognitive control.
    Article Snippet: Neuropsychology Posttraumatic Stress Symptomatology Rather Than Mild Traumatic Brain Injury Is Related to Atypical Early Neural Processing During Cognitive Control Kara L. Stevens, Craig A. Marquardt, Matthew A. Tong, Nicholas D. Davenport, and Scott R. Sponheim Online First Publication, April 7, 2025. https://dx.doi.org/10.1037/neu0001008 CITATION Stevens, K. L., Marquardt, C. A., Tong, M. A., Davenport, N. D., & Sponheim, S. R. (2025).. Posttraumatic stress symptomatology rather than mild traumatic brain injury is related to atypical early neural processing during cognitive control.. Neuropsychology.

    Article Title: Protocol for designing, conducting, and analyzing event-related potentials in human participants
    Article Snippet: .. Make sure that your recording software records the EEG in the BrainVision format, which is the format that was used in Pütz and colleagues. .. Note: When recording in the BrainVision format, your recordings will contain three separate files, with the file extensions .vhdr, .eeg, .vmk. b.



    Similar Products

    86
    Compumedics Neuroscan preprocessing eeg data
    Preprocessing Eeg Data, supplied by Compumedics Neuroscan, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/preprocessed+eeg+data/data+eeg/pm41692886-343-4-23
    Average 86 stars, based on 1 article reviews
    preprocessing eeg data - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    96
    MathWorks Inc pr es s 2 5 2 preprocessing eeg data 235 eeg data
    Pr Es S 2 5 2 Preprocessing Eeg Data 235 Eeg Data, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/preprocessed+eeg+data/Database+Toolbox/pm41353480-96-6-29
    Average 96 stars, based on 1 article reviews
    pr es s 2 5 2 preprocessing eeg data 235 eeg data - by Bioz Stars, 2026-11
    96/100 stars
      Buy from Supplier

    90
    MathWorks Inc eeg data preprocessing
    Eeg Data Preprocessing, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/preprocessed+eeg+data/pm40596140-134-2-14
    Average 90 stars, based on 1 article reviews
    eeg data preprocessing - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    brain products gmbh eeg raw data preprocessing
    Eeg Raw Data Preprocessing, supplied by brain products gmbh, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/preprocessed+eeg+data/eeg+preprocessing/pm40577938-136-2-14
    Average 90 stars, based on 1 article reviews
    eeg raw data preprocessing - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc eeg and respiratory data preprocessing
    a , Hypnogram of the full night for a single participant. b , Time-frequency representation (spectrogram) of the <t>EEG</t> data recording (exemplary channel Pz). c , Continuously estimated 1/f spectral slope (z-scored over the full recording) from channel Pz. Aperiodic activity was estimated within a one-second sliding window (75% overlap) applied to the whole-night time series recorded from each channel (see Methods for details). Colour code indicates the simultaneously scored sleep stage shown in panel a. The dark vertical line marks the segment enlarged below. d , The inset illustrates the z-scored 1/f slope (upper trace) and <t>z-scored</t> <t>respiratory</t> signal (lower trace) across an exemplary 40-second time window.
    Eeg And Respiratory Data Preprocessing, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/preprocessed+eeg+data/bio_rxiv__2025__06__03__657770-112-1-11
    Average 90 stars, based on 1 article reviews
    eeg and respiratory data preprocessing - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Brainvision Inc eeg data preprocessing software brainvision analyzer 2
    a , Hypnogram of the full night for a single participant. b , Time-frequency representation (spectrogram) of the <t>EEG</t> data recording (exemplary channel Pz). c , Continuously estimated 1/f spectral slope (z-scored over the full recording) from channel Pz. Aperiodic activity was estimated within a one-second sliding window (75% overlap) applied to the whole-night time series recorded from each channel (see Methods for details). Colour code indicates the simultaneously scored sleep stage shown in panel a. The dark vertical line marks the segment enlarged below. d , The inset illustrates the z-scored 1/f slope (upper trace) and <t>z-scored</t> <t>respiratory</t> signal (lower trace) across an exemplary 40-second time window.
    Eeg Data Preprocessing Software Brainvision Analyzer 2, supplied by Brainvision Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/preprocessed+eeg+data/eeg+recordings+brainvision+analyzer+2+1/10__1016_slash_j__bspc__2024__107128-128-9-8
    Average 90 stars, based on 1 article reviews
    eeg data preprocessing software brainvision analyzer 2 - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Brainvision Inc eeg data preprocessing and analysis software
    Erotica-induced modulation of NFR, pain, N2 and P2 in studies 2 and 3.
    Eeg Data Preprocessing And Analysis Software, supplied by Brainvision Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/preprocessed+eeg+data/brainvision+analyzer2/pmc11925531-225-7-15
    Average 90 stars, based on 1 article reviews
    eeg data preprocessing and analysis software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    a , Hypnogram of the full night for a single participant. b , Time-frequency representation (spectrogram) of the EEG data recording (exemplary channel Pz). c , Continuously estimated 1/f spectral slope (z-scored over the full recording) from channel Pz. Aperiodic activity was estimated within a one-second sliding window (75% overlap) applied to the whole-night time series recorded from each channel (see Methods for details). Colour code indicates the simultaneously scored sleep stage shown in panel a. The dark vertical line marks the segment enlarged below. d , The inset illustrates the z-scored 1/f slope (upper trace) and z-scored respiratory signal (lower trace) across an exemplary 40-second time window.

    Journal: bioRxiv

    Article Title: Respiratory coordination of excitability states across the human wake-sleep cycle

    doi: 10.1101/2025.06.03.657770

    Figure Lengend Snippet: a , Hypnogram of the full night for a single participant. b , Time-frequency representation (spectrogram) of the EEG data recording (exemplary channel Pz). c , Continuously estimated 1/f spectral slope (z-scored over the full recording) from channel Pz. Aperiodic activity was estimated within a one-second sliding window (75% overlap) applied to the whole-night time series recorded from each channel (see Methods for details). Colour code indicates the simultaneously scored sleep stage shown in panel a. The dark vertical line marks the segment enlarged below. d , The inset illustrates the z-scored 1/f slope (upper trace) and z-scored respiratory signal (lower trace) across an exemplary 40-second time window.

    Article Snippet: All EEG and respiratory data preprocessing was done in Fieldtrip for Matlab [ ].

    Techniques: Activity Assay

    a , Group-level distribution of 1/f slope across polysomnographic stages, averaged across all k = 60 EEG channels and irrespective of respiration phase. Tukey-Kramer-corrected significance is shown relative to wakefulness; full statistical results are provided in the main text. b , Group-level distribution of respiratory rates across stages. Across all pairwise comparisons, only the difference between N1 and SWS was significant ( p = .041, Tukey-Kramer-corrected). c , Polar representation of group-level mean 1/f slope ± SEM across respiration phase per polysomnographic stage, averaged across all k = 60 channels. Coloured dashed lines indicate mean directions of the respective circular distributions. FDR-corrected significance is shown relative to wakefulness; full statistics on differences in mean direction are provided in the main text. d , Polar histograms show the circular distribution of mean directions in 1/f slope across the n = 23 participants per stage. Polar plots show individual courses of aperiodic activity over respiration phase. FDR-corrected tests against circular uniformity were highly significant for all polysomnographic stages. Statistical results are provided in the main text. e , Polar histograms show the circular distribution of group-level mean directions in 1/f slope across the k = 60 electrodes per stage. Polar plots show electrode-specific courses of aperiodic activity over respiration phase. FDR-corrected tests against circular uniformity were highly significant for all sleep stages. Statistical results are provided in the main text. f , Detailed visualisation of topographic consistency in group-level average 1/f slope across all electrodes, sorted from anterior to posterior location.

    Journal: bioRxiv

    Article Title: Respiratory coordination of excitability states across the human wake-sleep cycle

    doi: 10.1101/2025.06.03.657770

    Figure Lengend Snippet: a , Group-level distribution of 1/f slope across polysomnographic stages, averaged across all k = 60 EEG channels and irrespective of respiration phase. Tukey-Kramer-corrected significance is shown relative to wakefulness; full statistical results are provided in the main text. b , Group-level distribution of respiratory rates across stages. Across all pairwise comparisons, only the difference between N1 and SWS was significant ( p = .041, Tukey-Kramer-corrected). c , Polar representation of group-level mean 1/f slope ± SEM across respiration phase per polysomnographic stage, averaged across all k = 60 channels. Coloured dashed lines indicate mean directions of the respective circular distributions. FDR-corrected significance is shown relative to wakefulness; full statistics on differences in mean direction are provided in the main text. d , Polar histograms show the circular distribution of mean directions in 1/f slope across the n = 23 participants per stage. Polar plots show individual courses of aperiodic activity over respiration phase. FDR-corrected tests against circular uniformity were highly significant for all polysomnographic stages. Statistical results are provided in the main text. e , Polar histograms show the circular distribution of group-level mean directions in 1/f slope across the k = 60 electrodes per stage. Polar plots show electrode-specific courses of aperiodic activity over respiration phase. FDR-corrected tests against circular uniformity were highly significant for all sleep stages. Statistical results are provided in the main text. f , Detailed visualisation of topographic consistency in group-level average 1/f slope across all electrodes, sorted from anterior to posterior location.

    Article Snippet: All EEG and respiratory data preprocessing was done in Fieldtrip for Matlab [ ].

    Techniques: Activity Assay

    Erotica-induced modulation of NFR, pain, N2 and P2 in studies 2 and 3.

    Journal: Neurobiology of Pain

    Article Title: Cerebral peak alpha frequency: Associations with chronic pain onset and pain modulation

    doi: 10.1016/j.ynpai.2025.100180

    Figure Lengend Snippet: Erotica-induced modulation of NFR, pain, N2 and P2 in studies 2 and 3.

    Article Snippet: For analysis of PEPs during CPM and ECON, EEG data were preprocessed and analyzed in BrainVision Analyzer Software (Version 2.1.2.327).

    Techniques:

    Mutilation-induced modulation of NFR, pain, N2 and P2 in studies 2 & 3.

    Journal: Neurobiology of Pain

    Article Title: Cerebral peak alpha frequency: Associations with chronic pain onset and pain modulation

    doi: 10.1016/j.ynpai.2025.100180

    Figure Lengend Snippet: Mutilation-induced modulation of NFR, pain, N2 and P2 in studies 2 & 3.

    Article Snippet: For analysis of PEPs during CPM and ECON, EEG data were preprocessed and analyzed in BrainVision Analyzer Software (Version 2.1.2.327).

    Techniques:

    Grand average EEG waveforms at Cz for ECON. Time windows used for analysis of N2 (90–140 ms) and P2 (280–350 ms) are shaded.

    Journal: Neurobiology of Pain

    Article Title: Cerebral peak alpha frequency: Associations with chronic pain onset and pain modulation

    doi: 10.1016/j.ynpai.2025.100180

    Figure Lengend Snippet: Grand average EEG waveforms at Cz for ECON. Time windows used for analysis of N2 (90–140 ms) and P2 (280–350 ms) are shaded.

    Article Snippet: For analysis of PEPs during CPM and ECON, EEG data were preprocessed and analyzed in BrainVision Analyzer Software (Version 2.1.2.327).

    Techniques: