Review




Structured Review

SPL Life Sciences picogreen reagent
Picogreen Reagent, supplied by SPL Life Sciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/picogreen/picogreen+reagent/pmc08243239-45-4-26
Average 90 stars, based on 1 article reviews
picogreen reagent - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

Staining:

Article Title: Verification of performance of a direct fluorescent assay for cell-free DNA quantification, stability according to pre-analytical storage conditions, and the effect of freeze-thawing
Article Snippet: .. For staining, 100 μl PicoGreen reagent was added volume to each sample in black 96-well plates for 3 min at room temperature (~20 ̊C; cat. no. SPL30296; SPL Life Sciences Co., Ltd.), and the mixture was diluted 400-fold. .. Fluorescence intensity was measured with a black 96-well microplate reader (Spark; Tecan Group, Ltd.) at an emission wavelength of 535 nm and an excitation wavelength of 485 nm.

96 Well Plates:

Article Title: Verification of performance of a direct fluorescent assay for cell-free DNA quantification, stability according to pre-analytical storage conditions, and the effect of freeze-thawing
Article Snippet: .. For staining, 100 μl PicoGreen reagent was added volume to each sample in black 96-well plates for 3 min at room temperature (~20 ̊C; cat. no. SPL30296; SPL Life Sciences Co., Ltd.), and the mixture was diluted 400-fold. .. Fluorescence intensity was measured with a black 96-well microplate reader (Spark; Tecan Group, Ltd.) at an emission wavelength of 535 nm and an excitation wavelength of 485 nm.



Similar Products

86
Yeasen Biotechnology picogreen dsdna quantitation
Picogreen Dsdna Quantitation, supplied by Yeasen Biotechnology, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/picogreen/dsdna+picogreen+quantitation+reagent/10__1096_slash_fj__202601242r-43-0-7
Average 86 stars, based on 1 article reviews
picogreen dsdna quantitation - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Fisher Scientific picogreen dsdna assay kit
Picogreen Dsdna Assay Kit, supplied by Fisher Scientific, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/picogreen/assay+bca+kit+protein/pm42156746-379-28-32
Average 86 stars, based on 1 article reviews
picogreen dsdna assay kit - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Yeasen Biotechnology picogreen dsdna quantitation reagent
The standard curve was generated by plotting the fluorescence intensity against the <t>dsDNA</t> concentration (ng/mL). Due to the wide dynamic range of the assay, both axes are presented with a break to clearly display the low-concentration region (0–50 ng/mL) and the high-concentration region (50–1,000 ng/mL) on a single graph. Data points represent the mean <t>PicoGreen</t> fluorescence from a single independent experiment, performed with at least three technical replicates per dsDNA concentration. The dsDNA concentrations shown are consistent with those listed in . Standard deviations (SD) were calculated for each concentration, and the coefficients of variation were consistently below 5% across all concentrations tested. The linear regression equation is y = 15.9x + 78.831 (R 2 = 1), where y is PicoGreen fluorescence intensity and x is dsDNA concentration in ng/mL. Unknown concentrations can be calculated as x = (y - 78.831)/15.92. The dsDNA detection range is 1–1,000 ng/mL.
Picogreen Dsdna Quantitation Reagent, supplied by Yeasen Biotechnology, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/picogreen/dsdna+picogreen+quantitation+reagent/pmc13156701-148-0-4
Average 86 stars, based on 1 article reviews
picogreen dsdna quantitation reagent - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Fisher Scientific quant it picogreen assay
The standard curve was generated by plotting the fluorescence intensity against the <t>dsDNA</t> concentration (ng/mL). Due to the wide dynamic range of the assay, both axes are presented with a break to clearly display the low-concentration region (0–50 ng/mL) and the high-concentration region (50–1,000 ng/mL) on a single graph. Data points represent the mean <t>PicoGreen</t> fluorescence from a single independent experiment, performed with at least three technical replicates per dsDNA concentration. The dsDNA concentrations shown are consistent with those listed in . Standard deviations (SD) were calculated for each concentration, and the coefficients of variation were consistently below 5% across all concentrations tested. The linear regression equation is y = 15.9x + 78.831 (R 2 = 1), where y is PicoGreen fluorescence intensity and x is dsDNA concentration in ng/mL. Unknown concentrations can be calculated as x = (y - 78.831)/15.92. The dsDNA detection range is 1–1,000 ng/mL.
Quant It Picogreen Assay, supplied by Fisher Scientific, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/picogreen/assay+ribogreen/pm42012728-114-8-11
Average 86 stars, based on 1 article reviews
quant it picogreen assay - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Yeasen Biotechnology cells with picogreen
The standard curve was generated by plotting the fluorescence intensity against the <t>dsDNA</t> concentration (ng/mL). Due to the wide dynamic range of the assay, both axes are presented with a break to clearly display the low-concentration region (0–50 ng/mL) and the high-concentration region (50–1,000 ng/mL) on a single graph. Data points represent the mean <t>PicoGreen</t> fluorescence from a single independent experiment, performed with at least three technical replicates per dsDNA concentration. The dsDNA concentrations shown are consistent with those listed in . Standard deviations (SD) were calculated for each concentration, and the coefficients of variation were consistently below 5% across all concentrations tested. The linear regression equation is y = 15.9x + 78.831 (R 2 = 1), where y is PicoGreen fluorescence intensity and x is dsDNA concentration in ng/mL. Unknown concentrations can be calculated as x = (y - 78.831)/15.92. The dsDNA detection range is 1–1,000 ng/mL.
Cells With Picogreen, supplied by Yeasen Biotechnology, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/picogreen/cells+picogreen12641es01+with/pm41992317-170-9-12
Average 86 stars, based on 1 article reviews
cells with picogreen - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Yeasen Biotechnology picogreen
The standard curve was generated by plotting the fluorescence intensity against the <t>dsDNA</t> concentration (ng/mL). Due to the wide dynamic range of the assay, both axes are presented with a break to clearly display the low-concentration region (0–50 ng/mL) and the high-concentration region (50–1,000 ng/mL) on a single graph. Data points represent the mean <t>PicoGreen</t> fluorescence from a single independent experiment, performed with at least three technical replicates per dsDNA concentration. The dsDNA concentrations shown are consistent with those listed in . Standard deviations (SD) were calculated for each concentration, and the coefficients of variation were consistently below 5% across all concentrations tested. The linear regression equation is y = 15.9x + 78.831 (R 2 = 1), where y is PicoGreen fluorescence intensity and x is dsDNA concentration in ng/mL. Unknown concentrations can be calculated as x = (y - 78.831)/15.92. The dsDNA detection range is 1–1,000 ng/mL.
Picogreen, supplied by Yeasen Biotechnology, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/picogreen/picogreen/pm42025044-162-0-4
Average 86 stars, based on 1 article reviews
picogreen - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Yeasen Biotechnology picogreen dsdna assay kit
The standard curve was generated by plotting the fluorescence intensity against the <t>dsDNA</t> concentration (ng/mL). Due to the wide dynamic range of the assay, both axes are presented with a break to clearly display the low-concentration region (0–50 ng/mL) and the high-concentration region (50–1,000 ng/mL) on a single graph. Data points represent the mean <t>PicoGreen</t> fluorescence from a single independent experiment, performed with at least three technical replicates per dsDNA concentration. The dsDNA concentrations shown are consistent with those listed in . Standard deviations (SD) were calculated for each concentration, and the coefficients of variation were consistently below 5% across all concentrations tested. The linear regression equation is y = 15.9x + 78.831 (R 2 = 1), where y is PicoGreen fluorescence intensity and x is dsDNA concentration in ng/mL. Unknown concentrations can be calculated as x = (y - 78.831)/15.92. The dsDNA detection range is 1–1,000 ng/mL.
Picogreen Dsdna Assay Kit, supplied by Yeasen Biotechnology, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/picogreen/dsdna+picogreen+quantitation+reagent/pm41916025-86-5-9
Average 86 stars, based on 1 article reviews
picogreen dsdna assay kit - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

Image Search Results


The standard curve was generated by plotting the fluorescence intensity against the dsDNA concentration (ng/mL). Due to the wide dynamic range of the assay, both axes are presented with a break to clearly display the low-concentration region (0–50 ng/mL) and the high-concentration region (50–1,000 ng/mL) on a single graph. Data points represent the mean PicoGreen fluorescence from a single independent experiment, performed with at least three technical replicates per dsDNA concentration. The dsDNA concentrations shown are consistent with those listed in . Standard deviations (SD) were calculated for each concentration, and the coefficients of variation were consistently below 5% across all concentrations tested. The linear regression equation is y = 15.9x + 78.831 (R 2 = 1), where y is PicoGreen fluorescence intensity and x is dsDNA concentration in ng/mL. Unknown concentrations can be calculated as x = (y - 78.831)/15.92. The dsDNA detection range is 1–1,000 ng/mL.

Journal: Bio-protocol

Article Title: A Cell-Based Protocol to Assess Manganese Content and Relative Transport Activity of Manganese Transporters

doi: 10.21769/BioProtoc.5680

Figure Lengend Snippet: The standard curve was generated by plotting the fluorescence intensity against the dsDNA concentration (ng/mL). Due to the wide dynamic range of the assay, both axes are presented with a break to clearly display the low-concentration region (0–50 ng/mL) and the high-concentration region (50–1,000 ng/mL) on a single graph. Data points represent the mean PicoGreen fluorescence from a single independent experiment, performed with at least three technical replicates per dsDNA concentration. The dsDNA concentrations shown are consistent with those listed in . Standard deviations (SD) were calculated for each concentration, and the coefficients of variation were consistently below 5% across all concentrations tested. The linear regression equation is y = 15.9x + 78.831 (R 2 = 1), where y is PicoGreen fluorescence intensity and x is dsDNA concentration in ng/mL. Unknown concentrations can be calculated as x = (y - 78.831)/15.92. The dsDNA detection range is 1–1,000 ng/mL.

Article Snippet: Picogreen dsDNA quantitation reagent (YEASEN, catalog number: 12641ES04) Western blotting 17.

Techniques: Generated, Fluorescence, Concentration Assay