Review




Structured Review

Vision RT Ltd alignrt
Shift of the target in the MLC defined field, with respect to the radiation isocenter in the left–right and superior-inferior directions versus couch angle. Three primary couch angles are shown. The coordinate system is shifted so that radiation isocenter is at position 0,0 at couch angle 0°. <t>AlignRT</t> measured, ●, and Winston-Lutz calculated, solid line, data are shown. Couch rotation centers measured by Winston-Lutz (*) and AlignRT methods (▲) are shown. The error bars indicate the uncertainty in these measurement methods as explained in the text.
Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/optical+surface+imaging+systems+alignrt/alignrt/pmc08861408-76-11-12
Average 90 stars, based on 1 article reviews
alignrt - by Bioz Stars, 2026-11
90/100 stars

Images

1) Product Images from "Positions of radiation isocenter and the couch rotation center established by Winston-Lutz and optical measurements"

Article Title: Positions of radiation isocenter and the couch rotation center established by Winston-Lutz and optical measurements

Journal: Technical Innovations & Patient Support in Radiation Oncology

doi: 10.1016/j.tipsro.2022.01.004

Shift of the target in the MLC defined field, with respect to the radiation isocenter in the left–right and superior-inferior directions versus couch angle. Three primary couch angles are shown. The coordinate system is shifted so that radiation isocenter is at position 0,0 at couch angle 0°. AlignRT measured, ●, and Winston-Lutz calculated, solid line, data are shown. Couch rotation centers measured by Winston-Lutz (*) and AlignRT methods (▲) are shown. The error bars indicate the uncertainty in these measurement methods as explained in the text.
Figure Legend Snippet: Shift of the target in the MLC defined field, with respect to the radiation isocenter in the left–right and superior-inferior directions versus couch angle. Three primary couch angles are shown. The coordinate system is shifted so that radiation isocenter is at position 0,0 at couch angle 0°. AlignRT measured, ●, and Winston-Lutz calculated, solid line, data are shown. Couch rotation centers measured by Winston-Lutz (*) and AlignRT methods (▲) are shown. The error bars indicate the uncertainty in these measurement methods as explained in the text.

Techniques Used:

 AlignRT  measurement of the position of the couch rotation center with respect to the center of the MLC defined field with the gantry at 0°.
Figure Legend Snippet: AlignRT measurement of the position of the couch rotation center with respect to the center of the MLC defined field with the gantry at 0°.

Techniques Used:

Related Articles

other:

Article Title: Systems and methods for patient positioning during radiotherapy
Article Snippet: The treatment room is equipped with AlignRT (VisionRT, U.K.), an FDA approved optical motion tracking system for radiation therapy that evaluates changes in position of a ROI in 6 DOF to sub-millimeter accuracy.

Article Title: A Study on Synchronous Bilateral Breast Cancer Radiotherapy Based on an Accelerator Integrated with Optical Surface Monitoring System
Article Snippet: AlignRT (VisionRT, London) is a commercially available optical surface monitoring system (OSMS) that provides real-time visual feedback on patient motion by continuously monitoring the patient's surface region of interest(ROI) during treatment process.

Article Title: A Study on Synchronous Bilateral Breast Cancer Radiotherapy Based on an Accelerator Integrated with Optical Surface Monitoring System.
Article Snippet: AlignRT (VisionRT, London) is a commercially available optical surface monitoring system (OSMS) that provides real-time visual feedback on patient motion by continuously monitoring the patient’s surface region of interest(ROI) during treatment process.

Article Title: Tattoo-less chest wall and regional nodal irradiation using surface imaging
Article Snippet: To compare TTB versus surface-imaging setup approaches, techniques were alternated daily for each patient: traditional TTB was employed for all patients on odd-numbered days of the month, alternating with tattoo-less setup via surface imaging using the AlignRT® system (VisionRT, London, UK) (ART).

Software:

Article Title: Comparison between the SGRT and the conventional setup method for patients undergoing VMAT for pelvic malignancies.
Article Snippet: Purpose: Surface Guided Radiation Treatment (SGRT) is a new method of positioning and monitoring patients on the linear accelerator’s couch, using visual light cameras to monitor the skin’s surface.. The purpose of this study was to compare the SGRT with the conventional method, based on lasers and tattoos, in terms of accuracy and time expenditure, on patients with pelvic malignancies.. Materials and methods: A group of 34 patients were enrolled in this study, 24 males who underwent radiotherapy prostate treatment and 10 females who underwent gynecological radiation therapy.



Similar Products

90
Vision RT Ltd optical surface imaging (osi) systems alignrt
Optical Surface Imaging (Osi) Systems Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/optical+surface+imaging+systems+alignrt/optical+surface+monitoring+system+alignrt/pmc12149718-42-9-10
Average 90 stars, based on 1 article reviews
optical surface imaging (osi) systems alignrt - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Vision RT Ltd optical surface imaging systems alignrt
Optical Surface Imaging Systems Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/optical+surface+imaging+systems+alignrt/optical+surface+monitoring+system+alignrt/pm40123313-23-3-10
Average 90 stars, based on 1 article reviews
optical surface imaging systems alignrt - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Vision RT Ltd optical 3d surface imaging system alignrt
Statistical summary of the <t> AlignRT </t> mean and max magnitude readouts of a phantom.
Optical 3d Surface Imaging System Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/optical+surface+imaging+systems+alignrt/3d+surface+imaging+system+alignrt/pmc07484878-53-11-12
Average 90 stars, based on 1 article reviews
optical 3d surface imaging system alignrt - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Vision RT Ltd optical surface imaging system alignrt
Room set up of the Mevion S250™ proton therapy machine equipped with <t>AlignRT.</t> The couch angles are labeled in the figure. The couch angle for the mannequin set up shown in the figure is 270 degrees
Optical Surface Imaging System Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/optical+surface+imaging+systems+alignrt/optical+surface+monitoring+system+alignrt/pmc06907344-33-1-6
Average 90 stars, based on 1 article reviews
optical surface imaging system alignrt - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Statistical summary of the  AlignRT  mean and max magnitude readouts of a phantom.

Journal: Journal of Applied Clinical Medical Physics

Article Title: Validating robotic couch isocentricity with 3D surface imaging

doi: 10.1002/acm2.12939

Figure Lengend Snippet: Statistical summary of the AlignRT mean and max magnitude readouts of a phantom.

Article Snippet: The accuracy of a commercially available optical 3D surface imaging system, AlignRT (VisionRT Ltd., London UK) has been shown by several studies to be within 1 mm., Here we investigate sensitivity and specificity of a surface imaging system for identifying excessive mechanical runout in a robotic couch rotation.

Techniques:

Statistical summary of the  AlignRT  mean and max magnitude readouts of volunteers.

Journal: Journal of Applied Clinical Medical Physics

Article Title: Validating robotic couch isocentricity with 3D surface imaging

doi: 10.1002/acm2.12939

Figure Lengend Snippet: Statistical summary of the AlignRT mean and max magnitude readouts of volunteers.

Article Snippet: The accuracy of a commercially available optical 3D surface imaging system, AlignRT (VisionRT Ltd., London UK) has been shown by several studies to be within 1 mm., Here we investigate sensitivity and specificity of a surface imaging system for identifying excessive mechanical runout in a robotic couch rotation.

Techniques:

A distribution of the reported deviation magnitude for AlignRT following 0, 0.2, 0.4, 0.6, and 0.8 cm shifts from isocenter, in conjunction with a 90° rotation. Upper and lower panels represent the results from immobilized and nonimmobilized volunteers respectively.

Journal: Journal of Applied Clinical Medical Physics

Article Title: Validating robotic couch isocentricity with 3D surface imaging

doi: 10.1002/acm2.12939

Figure Lengend Snippet: A distribution of the reported deviation magnitude for AlignRT following 0, 0.2, 0.4, 0.6, and 0.8 cm shifts from isocenter, in conjunction with a 90° rotation. Upper and lower panels represent the results from immobilized and nonimmobilized volunteers respectively.

Article Snippet: The accuracy of a commercially available optical 3D surface imaging system, AlignRT (VisionRT Ltd., London UK) has been shown by several studies to be within 1 mm., Here we investigate sensitivity and specificity of a surface imaging system for identifying excessive mechanical runout in a robotic couch rotation.

Techniques:

Represents the number of true/false positives and true/false negatives for detecting couch runouts ≥2 mm using a 2 mm action level on the  AlignRT  displacement vector.

Journal: Journal of Applied Clinical Medical Physics

Article Title: Validating robotic couch isocentricity with 3D surface imaging

doi: 10.1002/acm2.12939

Figure Lengend Snippet: Represents the number of true/false positives and true/false negatives for detecting couch runouts ≥2 mm using a 2 mm action level on the AlignRT displacement vector.

Article Snippet: The accuracy of a commercially available optical 3D surface imaging system, AlignRT (VisionRT Ltd., London UK) has been shown by several studies to be within 1 mm., Here we investigate sensitivity and specificity of a surface imaging system for identifying excessive mechanical runout in a robotic couch rotation.

Techniques: Plasmid Preparation

Represents the number of true/false positives and true/false negatives for detecting couch runouts ≥4 mm using a 4 mm action level on the  AlignRT  displacement vector.

Journal: Journal of Applied Clinical Medical Physics

Article Title: Validating robotic couch isocentricity with 3D surface imaging

doi: 10.1002/acm2.12939

Figure Lengend Snippet: Represents the number of true/false positives and true/false negatives for detecting couch runouts ≥4 mm using a 4 mm action level on the AlignRT displacement vector.

Article Snippet: The accuracy of a commercially available optical 3D surface imaging system, AlignRT (VisionRT Ltd., London UK) has been shown by several studies to be within 1 mm., Here we investigate sensitivity and specificity of a surface imaging system for identifying excessive mechanical runout in a robotic couch rotation.

Techniques: Plasmid Preparation

Room set up of the Mevion S250™ proton therapy machine equipped with AlignRT. The couch angles are labeled in the figure. The couch angle for the mannequin set up shown in the figure is 270 degrees

Journal: Radiation Oncology (London, England)

Article Title: A novel approach to Verify air gap and SSD for proton radiotherapy using surface imaging

doi: 10.1186/s13014-019-1436-4

Figure Lengend Snippet: Room set up of the Mevion S250™ proton therapy machine equipped with AlignRT. The couch angles are labeled in the figure. The couch angle for the mannequin set up shown in the figure is 270 degrees

Article Snippet: An optical surface imaging system AlignRT (VisionRT, London, United Kingdom) was installed in our proton center in 2017 and has been routinely used to guide treatment setup and treatment.

Techniques: Labeling

An example of comparison of BEV in TPS, reconstructed CT surface, and AlignRT (VRT) captured surface

Journal: Radiation Oncology (London, England)

Article Title: A novel approach to Verify air gap and SSD for proton radiotherapy using surface imaging

doi: 10.1186/s13014-019-1436-4

Figure Lengend Snippet: An example of comparison of BEV in TPS, reconstructed CT surface, and AlignRT (VRT) captured surface

Article Snippet: An optical surface imaging system AlignRT (VisionRT, London, United Kingdom) was installed in our proton center in 2017 and has been routinely used to guide treatment setup and treatment.

Techniques: Comparison