Review




Structured Review

Gesellschaft fur Silizium-Mikrosysteme nanoplotter 2.1
Nanoplotter 2.1, supplied by Gesellschaft fur Silizium-Mikrosysteme, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/non-contact+high+performance+microarray+printer/nano+plotter+2+1/pmc03493956-86-29-34
Average 90 stars, based on 1 article reviews
nanoplotter 2.1 - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

other:

Article Title: Insights Into Glycobiology and the Protein-Glycan Interactome Using Glycan Microarray Technologies
Article Snippet: Examples of non-contact printers in the literature include SciFlexArrayers from Scienion, Mercury from ArrayJet, M2-automation systems from axiVEND, and Nano-Plotter from GESIM.

Article Title: Lectin-based diagnostics of cancers
Article Snippet: Preparation of Biotinylated 5A10 Fab Spots Biotinylated 5A10 Fab (100 μg/mL) was printed in an array-in-well format onto the yellow streptavidin-coated 96-well microtiter plates (Kaivogen, Finland) with a Nano-Plotter noncontact microdispensing instrument (GeSiM, Germany) by using settings: 70% humidity, pulse 50 μs, voltage 90 V, delay 250 μs, frequency 100 Hz.

Article Title: Detection of egg white allergy in children by specific IgE microarray chemiluminescence immunoassay.
Article Snippet: Background: Allergen testing has emerged as a pivotal component in prevention and treatment strategies for allergic diseases among children and the utilization of specific IgE (sIgE) through a fully automated chemiluminescent microarray immunoassay (CLMIA) has emerged as a promising trend in the simultaneous detection of multiple allergenic components of children.. Methods: The accuracy and reliability of CLMIA were verified using children’s serum samples that concentrated on allergens. the allergens.. The clinical diagnostic practicability of CLMIA was assessed through comprehensive evaluations including measurements of the limit of detection (LOD), intra-batch, and inter-batch precision, linearity analysis, the cross-contamination rate, and the concordance rate with the Phadia system.

Article Title: Fluidic Interface for Surface-based DNA Origami Studies.
Article Snippet: Depending on the DON protruding tags, a 10 μM solution of the complementary capture o l i g o n u c l e o t i d e s e q u e n c e a F 1 ( 5 ′ - N H 2 - C 1 2 - TTTTTTTTCCTGCGTCGTTT-3′) or aATG (5′-NH2-C6TTTTTTTTATGATGATGATG-3′) in trehalose buffer (200 mM K2HPO4, 200 mM KH2PO4, 0.5% trehalose dehydrate, pH 7.6) was inkjet printed on epoxy-reactive glass slides using a NanoPlotter 2.1 (GeSiM).

Article Title: Microarray-Based Methodology for Lipid Profiling, Enzymatic Activity, And Binding Assays in Printed Lipid Raft Membranes from Astrocytes and Neurons
Article Snippet: Raft preparations were printed onto preactivated glass slides using a noncontact microarrayer with a solenoid tip (Nanoplotter NP2.1, GeSiM Bioinstruments, and Microfluidics, Radeberg, Germany), placing 3 replicates of each sample (3 nl/drop, 10 drops/spot).

Article Title: Synthesis of trisaccharide antigens featuring colitose, abequose and fucose residues and assessment of antibody binding on antigen arrays.
Article Snippet: Printing was done on NEXTERION® 3-D Hydrogel coated slides (Schott Nexterion, Jena, Germany) using the Nanoplotter NP2.1 (GeSiM, Dresden, Germany).

Article Title: Microarray-Based Methodology for Lipid Profiling, Enzymatic Activity, And Binding Assays in Printed Lipid Raft Membranes from Astrocytes and Neurons.
Article Snippet: Raft preparations were printed onto preactivated glass slides using a noncontact microarrayer with a solenoid tip (Nanoplotter NP2.1, GeSiM Bioinstruments, and Microfluidics, Radeberg, Germany), placing 3 replicates of each sample (3 nl/drop, 10 drops/ spot).

Article Title: Fluidic Interface for Surface-based DNA Origami Studies
Article Snippet: Depending on the DON protruding tags, a 10 μM solution of the complementary capture oligonucleotide sequence aF1 (5′-NH 2 -C12-TTTTTTTTCCTGCGTCGTTT-3′) or aATG (5′-NH 2 -C6-TTTTTTTTATGATGATGATG-3′) in trehalose buffer (200 mM K 2 HPO 4 , 200 mM KH 2 PO 4 , 0.5% trehalose dehydrate, pH 7.6) was inkjet printed on epoxy-reactive glass slides using a NanoPlotter 2.1 (GeSiM).



Similar Products

90
PolyAn GmbH non-contact high performance microarray printer
Composition of global HIV-1 peptide <t> microarray. </t>
Non Contact High Performance Microarray Printer, supplied by PolyAn GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/non-contact+high+performance+microarray+printer/non+contact+high+performance+microarray+printer/pmc04324361-101-6-14
Average 90 stars, based on 1 article reviews
non-contact high performance microarray printer - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Composition of global HIV-1 peptide  microarray.

Journal: Journal of immunological methods

Article Title: Quantification of the Epitope Diversity of HIV-1-Specific Binding Antibodies by Peptide Microarrays for Global HIV-1 Vaccine Development

doi: 10.1016/j.jim.2014.11.006

Figure Lengend Snippet: Composition of global HIV-1 peptide microarray.

Article Snippet: Peptide microarrays were produced using a non-contact high performance microarray printer on epoxy-modified slides (PolyAn; Germany).

Techniques: Microarray

The signal distribution of a representative microarray is displayed, as well as the correlation between slide sub-arrays. This data is following incubation with serum from an HIV-1-infected subject. SA, subarray; Rq, R squared; Sl, slope; In, intersection with the y axis; MC2, two closest values between the 3 sub-arrays; MC2 1 and MC2 2, each component of MC2.

Journal: Journal of immunological methods

Article Title: Quantification of the Epitope Diversity of HIV-1-Specific Binding Antibodies by Peptide Microarrays for Global HIV-1 Vaccine Development

doi: 10.1016/j.jim.2014.11.006

Figure Lengend Snippet: The signal distribution of a representative microarray is displayed, as well as the correlation between slide sub-arrays. This data is following incubation with serum from an HIV-1-infected subject. SA, subarray; Rq, R squared; Sl, slope; In, intersection with the y axis; MC2, two closest values between the 3 sub-arrays; MC2 1 and MC2 2, each component of MC2.

Article Snippet: Peptide microarrays were produced using a non-contact high performance microarray printer on epoxy-modified slides (PolyAn; Germany).

Techniques: Microarray, Incubation, Infection

Top row: A, C, G, CRF02_AG; bottom row: B, D, CRF01_AE, and all other clades. The X-direction of each plot represents the sequence of gp120. Sequences segments included on the microarray are depicted in red. In the Y-direction all sequences for the respective clade from the alignment HIV1_ALL_2009_ENV_PRO.fasta are shown (total 2248). The average coverage (horizontally) for each used HIV-1 sequence is 50%. The evaluation of coverage was performed presuming the same length of all sequences for one protein or fragment within a given clade.

Journal: Journal of immunological methods

Article Title: Quantification of the Epitope Diversity of HIV-1-Specific Binding Antibodies by Peptide Microarrays for Global HIV-1 Vaccine Development

doi: 10.1016/j.jim.2014.11.006

Figure Lengend Snippet: Top row: A, C, G, CRF02_AG; bottom row: B, D, CRF01_AE, and all other clades. The X-direction of each plot represents the sequence of gp120. Sequences segments included on the microarray are depicted in red. In the Y-direction all sequences for the respective clade from the alignment HIV1_ALL_2009_ENV_PRO.fasta are shown (total 2248). The average coverage (horizontally) for each used HIV-1 sequence is 50%. The evaluation of coverage was performed presuming the same length of all sequences for one protein or fragment within a given clade.

Article Snippet: Peptide microarrays were produced using a non-contact high performance microarray printer on epoxy-modified slides (PolyAn; Germany).

Techniques: Sequencing, Microarray

The signal and noise distribution of data from a sample microarray is displayed, as well as the correlation between slide sub-arrays. Microarray data is following incubation with plasma from an HIV-1-infected subject. FDR, false discovery rate; SD, standard deviation.

Journal: Journal of immunological methods

Article Title: Quantification of the Epitope Diversity of HIV-1-Specific Binding Antibodies by Peptide Microarrays for Global HIV-1 Vaccine Development

doi: 10.1016/j.jim.2014.11.006

Figure Lengend Snippet: The signal and noise distribution of data from a sample microarray is displayed, as well as the correlation between slide sub-arrays. Microarray data is following incubation with plasma from an HIV-1-infected subject. FDR, false discovery rate; SD, standard deviation.

Article Snippet: Peptide microarrays were produced using a non-contact high performance microarray printer on epoxy-modified slides (PolyAn; Germany).

Techniques: Microarray, Incubation, Clinical Proteomics, Infection, Standard Deviation