Review




Structured Review

Mcs GmbH microelectrode arrays
Microelectrode Arrays, supplied by Mcs GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multi-electrode+array+mea+well/multi+electrode+array+mea/pmc04173299-119-65-72
Average 90 stars, based on 1 article reviews
microelectrode arrays - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

other:

Article Title: Meprin β Modulates Brevican Proteolysis Impairing Neural Plasticity and Memory Formation
Article Snippet: Slices rested in ACSF for at least 40 min before individual slices were transferred onto a multi‐electrode array (MEA) chip of a two‐chamber MEA system (MEA2100 System, Multi‐Channel Systems MCS GmbH), which was constantly perfused with normal ACSF at 32°C.

Article Title: Electric spiking activity in epithelial cells
Article Snippet: Extracellular electric potential measurement Multi-electrode array (MEA) chips (60ThinMEA200/30iR-ITO) were purchased from Multi Channel System MCS GmbH (Germany).

Article Title: Human sensory-like neuron cultivation—An optimized protocol
Article Snippet: The electrical activity of iSNs was assessed using a multiwell multi-electrode array (MEA) system comprising 24 individual wells with 12 electrodes per well (Multi Channel Systems MCS GmbH, Reutlingen, Germany).

Article Title: Durable Thin-Film DLC on Wafer Surfaces of Gravure Cylinders for Roll-to-Roll Printing of 1-Bit Electrodes and Microtext in Flexible Electronics and Graphic Security.
Article Snippet: Diamond-Like Carbon (DLC), a thin-film material, is emerging as a promising alternative for durable surfaces due to its eco-friendly application process.. This study evaluated the use of thin-film DLC on the wafer surface of gravure cylinders for roll-to-roll printing of fine-line electrodes and microtext patterns, specifically for applications in flexible electronics and graphics security.. Results suggested that using thin film DLC on the wafer surface allows reliable reproduction of isometric grids and line structures with widths of 15, 20, and 30 μm, as well as solid electrodes.

Article Title: autoMEA: machine learning-based burst detection for multi-electrode array datasets
Article Snippet: Neurons were plated in a multiwell multi-electrode array (MEA) plate with an epoxy base (Multichannel Systems, MCS GmbH, Reutlingen, Germany) in a density of 35,000 neurons/well.

Article Title: Quality of life and survivorship in patients with low-grade ovarian cancer.
Article Snippet: Multiwell microelectrode arrays (MEAs) is a useful for the recording and analysis of neuronal activity.27 MEAs (MCS, GmbH, Reutlingen, Germany) containing 24 wells, each with 12 round electrodes (30 mm diameter) were used.

Activity Assay:

Article Title: Robust In Vitro Models for Studying Parkinson's Disease? LUHMES Cells and SH-SH5Y Cells.
Article Snippet: .. Microelectrode arrays (60MEA200/30iR/T, Multi-Channel Systems MCS GmbH, 72770 Reutlingen, Germany) recorded neuronal activity. .. Briefly, microelectrode arrays were coated with 1 mL 50μg/mL poly-L-ornithine (PLO; Sigma-Aldrich) and 1 μg/mL fibronectin from human plasma (Sigma-Aldrich) for 24 h at 37 ◦C.

Article Title: Robust In Vitro Models for Studying Parkinson’s Disease? LUHMES Cells and SH-SH5Y Cells
Article Snippet: .. Microelectrode arrays (60MEA200/30iR/T, Multi-Channel Systems MCS GmbH, 72770 Reutlingen, Germany) recorded neuronal activity. .. Briefly, microelectrode arrays were coated with 1 mL 50 μg/mL poly-L-ornithine (PLO; Sigma-Aldrich) and 1 μg/mL fibronectin from human plasma (Sigma-Aldrich) for 24 h at 37 °C.



Similar Products

90
Axion BioSystems multi-electrode array mea well
Multi Electrode Array Mea Well, supplied by Axion BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multi-electrode+array+mea+well/cytoview+mea+24+well+plates/us12223643-161-7-12
Average 90 stars, based on 1 article reviews
multi-electrode array mea well - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Axion BioSystems multi-electrode array (mea) 48-well plates axion biosystems #m768-tmea-48b
Multi Electrode Array (Mea) 48 Well Plates Axion Biosystems #M768 Tmea 48b, supplied by Axion BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multi-electrode+array+mea+well/m768+glx+12+well+plates/pmc11631337-84-25-33
Average 90 stars, based on 1 article reviews
multi-electrode array (mea) 48-well plates axion biosystems #m768-tmea-48b - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Axion BioSystems multi-electrode array (mea) 24-well plates
Multi Electrode Array (Mea) 24 Well Plates, supplied by Axion BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multi-electrode+array+mea+well/cytoview+mea+24+well+plates/pmc11538552-94-5-11
Average 90 stars, based on 1 article reviews
multi-electrode array (mea) 24-well plates - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Axion BioSystems multi-electrode array (mea) 48-well plates
Multi Electrode Array (Mea) 48 Well Plates, supplied by Axion BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multi-electrode+array+mea+well/cytoview+mea+24+well+plates/pm39441987-78-35-42
Average 90 stars, based on 1 article reviews
multi-electrode array (mea) 48-well plates - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Mcs GmbH multiwell multi-electrode array (mea) system comprising 24 individual wells with 12 electrodes per well
Validation of neuronal integrity. (A) Viability assay of iSNs following treatment with increasing concentrations of FdU and AraC for up to 72 h. SDS was used as negative ctrl, 10 μM of FdU for 24 h. The data of n = 3 differentiations, one-way ANOVA with post-hoc Tukey's HSD. * p < 0.05; *** p < 0.001. (B) iSNs generated using our optimized protocol express the sensory neuron marker Nav1.8, the peripheral neuron marker PRPH, and a general neuronal marker TUJ1. The scale bar = 100 μm. (C, D) Spontaneous electrical activity in iSNs was measured at 4 (I), 5 (II), and 6 (III) weeks of maturation using a <t>multi-electrode</t> array system, with activity detectable starting from 4 weeks of maturation. Scale: 50 μV/10 s. (D) Raster plot of one well over 4 (I), 5 (II), and 6 (III) weeks of maturation showing the single and developing network activity. For (C, D) n = 3 triplicates from 1 differentiation. ICC, immunocytochemistry; Nav1.8, voltage-gated sodium channel 1.8; PRPH, peripherin; TUJ1, Beta-III-tubulin.
Multiwell Multi Electrode Array (Mea) System Comprising 24 Individual Wells With 12 Electrodes Per Well, supplied by Mcs GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multi-electrode+array+mea+well/256+electrode+mea/pmc11484056-73-20-26
Average 90 stars, based on 1 article reviews
multiwell multi-electrode array (mea) system comprising 24 individual wells with 12 electrodes per well - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Axion BioSystems axion e-stim+ classic multi-electrode array (mea) 48-well plate
Validation of neuronal integrity. (A) Viability assay of iSNs following treatment with increasing concentrations of FdU and AraC for up to 72 h. SDS was used as negative ctrl, 10 μM of FdU for 24 h. The data of n = 3 differentiations, one-way ANOVA with post-hoc Tukey's HSD. * p < 0.05; *** p < 0.001. (B) iSNs generated using our optimized protocol express the sensory neuron marker Nav1.8, the peripheral neuron marker PRPH, and a general neuronal marker TUJ1. The scale bar = 100 μm. (C, D) Spontaneous electrical activity in iSNs was measured at 4 (I), 5 (II), and 6 (III) weeks of maturation using a <t>multi-electrode</t> array system, with activity detectable starting from 4 weeks of maturation. Scale: 50 μV/10 s. (D) Raster plot of one well over 4 (I), 5 (II), and 6 (III) weeks of maturation showing the single and developing network activity. For (C, D) n = 3 triplicates from 1 differentiation. ICC, immunocytochemistry; Nav1.8, voltage-gated sodium channel 1.8; PRPH, peripherin; TUJ1, Beta-III-tubulin.
Axion E Stim+ Classic Multi Electrode Array (Mea) 48 Well Plate, supplied by Axion BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multi-electrode+array+mea+well/cytoview+mea+48/pm39189070-169-73-80
Average 90 stars, based on 1 article reviews
axion e-stim+ classic multi-electrode array (mea) 48-well plate - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Axion BioSystems e-stim+ classic multi-electrode array (mea) 48-well plate
Validation of neuronal integrity. (A) Viability assay of iSNs following treatment with increasing concentrations of FdU and AraC for up to 72 h. SDS was used as negative ctrl, 10 μM of FdU for 24 h. The data of n = 3 differentiations, one-way ANOVA with post-hoc Tukey's HSD. * p < 0.05; *** p < 0.001. (B) iSNs generated using our optimized protocol express the sensory neuron marker Nav1.8, the peripheral neuron marker PRPH, and a general neuronal marker TUJ1. The scale bar = 100 μm. (C, D) Spontaneous electrical activity in iSNs was measured at 4 (I), 5 (II), and 6 (III) weeks of maturation using a <t>multi-electrode</t> array system, with activity detectable starting from 4 weeks of maturation. Scale: 50 μV/10 s. (D) Raster plot of one well over 4 (I), 5 (II), and 6 (III) weeks of maturation showing the single and developing network activity. For (C, D) n = 3 triplicates from 1 differentiation. ICC, immunocytochemistry; Nav1.8, voltage-gated sodium channel 1.8; PRPH, peripherin; TUJ1, Beta-III-tubulin.
E Stim+ Classic Multi Electrode Array (Mea) 48 Well Plate, supplied by Axion BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multi-electrode+array+mea+well/cytoview+mea+24+well+plates/pmc11381919-152-75-82
Average 90 stars, based on 1 article reviews
e-stim+ classic multi-electrode array (mea) 48-well plate - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Axion BioSystems micro-electrode array (mea) multi-well plates
All experiments were undertaken in DIV12 cultures cultured in <t>CytoView</t> micro-electrode array <t>(MEA)</t> multi-well plates using the Maestro-Pro MEA system (Axion Biosystems). A Each well contains 16 electrodes that can record local activity B Fluorescent microscopy shows DIV12 primary cortical neurons transduced with AAV-Syn1-eGFP and cultured on a micro-electrode plate. Scale bar = 275 µm. C An example of a raster plot, which shows firing over time, taken at baseline from untransduced neurons. Each row corresponds to an individual electrode. Action potentials are recorded as spikes (black lines) and this is termed ‘firing’. A burst (blue) occurs when multiples action potentials fire in rapid succession in the locality of an electrode; a minimum threshold is set at 50 spikes within 100 ms. A network burst was classified as at least 35% of electrodes recording bursts simultaneously; this shows that the neurons throughout the culture are connected. D Representative raster plots showing 60 s recordings of untransduced neurons at baseline and following treatment with 0.625 µM 4AP/12.5 µM Bicuculline (Bic). Baseline recordings show spontaneous firing and bursting. Treatment with 4AP/Bic stimulates synchronous and oscillatory firing across the well, as shown by a switch to network bursting. E 4AP/Bic treatment significantly increases activity and ( F ) burst strength ( t -test, **** P < 0.0001, n = 3 technical repeats). G Representative raster plots comparing neurons overexpressing eGFP, eGFP-Tau WT or eGFP-Tau P301L at baseline and following treatment with 4AP/Bic. H At baseline, the activity and ( I ) burst strength of neurons overexpressing eGFP-Tau P301L is significantly greater than those expressing eGFP or eGFP-Tau WT . Following treatment with 4AP/Bic, activity but not burst strength is significantly greater with eGFP-Tau P301L than eGFP or eGFP-Tau WT (two-way ANOVA with Tukey’s multiple comparisons test, * p < 0.05, ** p < 0.01, *** p < 0.001, **** p < 0.0001, n = 4 technical repeats).
Micro Electrode Array (Mea) Multi Well Plates, supplied by Axion BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multi-electrode+array+mea+well/cytoview+mea+24+well+plates/pmc11189525-246-9-20
Average 90 stars, based on 1 article reviews
micro-electrode array (mea) multi-well plates - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Axion BioSystems multi-electrode array well-based system mea
All experiments were undertaken in DIV12 cultures cultured in <t>CytoView</t> micro-electrode array <t>(MEA)</t> multi-well plates using the Maestro-Pro MEA system (Axion Biosystems). A Each well contains 16 electrodes that can record local activity B Fluorescent microscopy shows DIV12 primary cortical neurons transduced with AAV-Syn1-eGFP and cultured on a micro-electrode plate. Scale bar = 275 µm. C An example of a raster plot, which shows firing over time, taken at baseline from untransduced neurons. Each row corresponds to an individual electrode. Action potentials are recorded as spikes (black lines) and this is termed ‘firing’. A burst (blue) occurs when multiples action potentials fire in rapid succession in the locality of an electrode; a minimum threshold is set at 50 spikes within 100 ms. A network burst was classified as at least 35% of electrodes recording bursts simultaneously; this shows that the neurons throughout the culture are connected. D Representative raster plots showing 60 s recordings of untransduced neurons at baseline and following treatment with 0.625 µM 4AP/12.5 µM Bicuculline (Bic). Baseline recordings show spontaneous firing and bursting. Treatment with 4AP/Bic stimulates synchronous and oscillatory firing across the well, as shown by a switch to network bursting. E 4AP/Bic treatment significantly increases activity and ( F ) burst strength ( t -test, **** P < 0.0001, n = 3 technical repeats). G Representative raster plots comparing neurons overexpressing eGFP, eGFP-Tau WT or eGFP-Tau P301L at baseline and following treatment with 4AP/Bic. H At baseline, the activity and ( I ) burst strength of neurons overexpressing eGFP-Tau P301L is significantly greater than those expressing eGFP or eGFP-Tau WT . Following treatment with 4AP/Bic, activity but not burst strength is significantly greater with eGFP-Tau P301L than eGFP or eGFP-Tau WT (two-way ANOVA with Tukey’s multiple comparisons test, * p < 0.05, ** p < 0.01, *** p < 0.001, **** p < 0.0001, n = 4 technical repeats).
Multi Electrode Array Well Based System Mea, supplied by Axion BioSystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multi-electrode+array+mea+well/cytoview+mea+24+well+plates/pmc11239925-141-6-8
Average 90 stars, based on 1 article reviews
multi-electrode array well-based system mea - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Validation of neuronal integrity. (A) Viability assay of iSNs following treatment with increasing concentrations of FdU and AraC for up to 72 h. SDS was used as negative ctrl, 10 μM of FdU for 24 h. The data of n = 3 differentiations, one-way ANOVA with post-hoc Tukey's HSD. * p < 0.05; *** p < 0.001. (B) iSNs generated using our optimized protocol express the sensory neuron marker Nav1.8, the peripheral neuron marker PRPH, and a general neuronal marker TUJ1. The scale bar = 100 μm. (C, D) Spontaneous electrical activity in iSNs was measured at 4 (I), 5 (II), and 6 (III) weeks of maturation using a multi-electrode array system, with activity detectable starting from 4 weeks of maturation. Scale: 50 μV/10 s. (D) Raster plot of one well over 4 (I), 5 (II), and 6 (III) weeks of maturation showing the single and developing network activity. For (C, D) n = 3 triplicates from 1 differentiation. ICC, immunocytochemistry; Nav1.8, voltage-gated sodium channel 1.8; PRPH, peripherin; TUJ1, Beta-III-tubulin.

Journal: Frontiers in Neuroscience

Article Title: Human sensory-like neuron cultivation—An optimized protocol

doi: 10.3389/fnins.2024.1429694

Figure Lengend Snippet: Validation of neuronal integrity. (A) Viability assay of iSNs following treatment with increasing concentrations of FdU and AraC for up to 72 h. SDS was used as negative ctrl, 10 μM of FdU for 24 h. The data of n = 3 differentiations, one-way ANOVA with post-hoc Tukey's HSD. * p < 0.05; *** p < 0.001. (B) iSNs generated using our optimized protocol express the sensory neuron marker Nav1.8, the peripheral neuron marker PRPH, and a general neuronal marker TUJ1. The scale bar = 100 μm. (C, D) Spontaneous electrical activity in iSNs was measured at 4 (I), 5 (II), and 6 (III) weeks of maturation using a multi-electrode array system, with activity detectable starting from 4 weeks of maturation. Scale: 50 μV/10 s. (D) Raster plot of one well over 4 (I), 5 (II), and 6 (III) weeks of maturation showing the single and developing network activity. For (C, D) n = 3 triplicates from 1 differentiation. ICC, immunocytochemistry; Nav1.8, voltage-gated sodium channel 1.8; PRPH, peripherin; TUJ1, Beta-III-tubulin.

Article Snippet: The electrical activity of iSNs was assessed using a multiwell multi-electrode array (MEA) system comprising 24 individual wells with 12 electrodes per well (Multi Channel Systems MCS GmbH, Reutlingen, Germany).

Techniques: Viability Assay, Generated, Marker, Activity Assay, Immunocytochemistry

All experiments were undertaken in DIV12 cultures cultured in CytoView micro-electrode array (MEA) multi-well plates using the Maestro-Pro MEA system (Axion Biosystems). A Each well contains 16 electrodes that can record local activity B Fluorescent microscopy shows DIV12 primary cortical neurons transduced with AAV-Syn1-eGFP and cultured on a micro-electrode plate. Scale bar = 275 µm. C An example of a raster plot, which shows firing over time, taken at baseline from untransduced neurons. Each row corresponds to an individual electrode. Action potentials are recorded as spikes (black lines) and this is termed ‘firing’. A burst (blue) occurs when multiples action potentials fire in rapid succession in the locality of an electrode; a minimum threshold is set at 50 spikes within 100 ms. A network burst was classified as at least 35% of electrodes recording bursts simultaneously; this shows that the neurons throughout the culture are connected. D Representative raster plots showing 60 s recordings of untransduced neurons at baseline and following treatment with 0.625 µM 4AP/12.5 µM Bicuculline (Bic). Baseline recordings show spontaneous firing and bursting. Treatment with 4AP/Bic stimulates synchronous and oscillatory firing across the well, as shown by a switch to network bursting. E 4AP/Bic treatment significantly increases activity and ( F ) burst strength ( t -test, **** P < 0.0001, n = 3 technical repeats). G Representative raster plots comparing neurons overexpressing eGFP, eGFP-Tau WT or eGFP-Tau P301L at baseline and following treatment with 4AP/Bic. H At baseline, the activity and ( I ) burst strength of neurons overexpressing eGFP-Tau P301L is significantly greater than those expressing eGFP or eGFP-Tau WT . Following treatment with 4AP/Bic, activity but not burst strength is significantly greater with eGFP-Tau P301L than eGFP or eGFP-Tau WT (two-way ANOVA with Tukey’s multiple comparisons test, * p < 0.05, ** p < 0.01, *** p < 0.001, **** p < 0.0001, n = 4 technical repeats).

Journal: Cell Death & Disease

Article Title: Tau P301L disengages from the proteosome core complex and neurogranin coincident with enhanced neuronal network excitability

doi: 10.1038/s41419-024-06815-2

Figure Lengend Snippet: All experiments were undertaken in DIV12 cultures cultured in CytoView micro-electrode array (MEA) multi-well plates using the Maestro-Pro MEA system (Axion Biosystems). A Each well contains 16 electrodes that can record local activity B Fluorescent microscopy shows DIV12 primary cortical neurons transduced with AAV-Syn1-eGFP and cultured on a micro-electrode plate. Scale bar = 275 µm. C An example of a raster plot, which shows firing over time, taken at baseline from untransduced neurons. Each row corresponds to an individual electrode. Action potentials are recorded as spikes (black lines) and this is termed ‘firing’. A burst (blue) occurs when multiples action potentials fire in rapid succession in the locality of an electrode; a minimum threshold is set at 50 spikes within 100 ms. A network burst was classified as at least 35% of electrodes recording bursts simultaneously; this shows that the neurons throughout the culture are connected. D Representative raster plots showing 60 s recordings of untransduced neurons at baseline and following treatment with 0.625 µM 4AP/12.5 µM Bicuculline (Bic). Baseline recordings show spontaneous firing and bursting. Treatment with 4AP/Bic stimulates synchronous and oscillatory firing across the well, as shown by a switch to network bursting. E 4AP/Bic treatment significantly increases activity and ( F ) burst strength ( t -test, **** P < 0.0001, n = 3 technical repeats). G Representative raster plots comparing neurons overexpressing eGFP, eGFP-Tau WT or eGFP-Tau P301L at baseline and following treatment with 4AP/Bic. H At baseline, the activity and ( I ) burst strength of neurons overexpressing eGFP-Tau P301L is significantly greater than those expressing eGFP or eGFP-Tau WT . Following treatment with 4AP/Bic, activity but not burst strength is significantly greater with eGFP-Tau P301L than eGFP or eGFP-Tau WT (two-way ANOVA with Tukey’s multiple comparisons test, * p < 0.05, ** p < 0.01, *** p < 0.001, **** p < 0.0001, n = 4 technical repeats).

Article Snippet: All experiments were undertaken in DIV12 cultures cultured in CytoView micro-electrode array (MEA) multi-well plates using the Maestro-Pro MEA system (Axion Biosystems).

Techniques: Cell Culture, Activity Assay, Microscopy, Transduction, Expressing