Review




Structured Review

STEMCELL Technologies Inc easysep mouse cd25 treg positive selection kit
Easysep Mouse Cd25 Treg Positive Selection Kit, supplied by STEMCELL Technologies Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mouse+treg+selection+kit/easysep+human+t+cell+isolation+kit/pm30612787-75-23-30
Average 90 stars, based on 1 article reviews
easysep mouse cd25 treg positive selection kit - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

Selection:

Article Title: Protocol for phenotyping and isolation of dendritic cell subsets from blood and lymphoid organs of non-human primates and humans by flow cytometry
Article Snippet: .. Magnetic depletion of unwanted populations using StemCell EasySep PE Positive Selection kit. a. ..

Article Title: A CARMIL2 gain-of-function mutation suffices to trigger most CD28 costimulatory functions in vivo
Article Snippet: Jurkat T cells were analyzed using anti-CD3 (OKT3), anti-CD28 (CD28.2), and anti-CD69 (FN50), all from BD. .. CD4 + and CD8 + T cells were purified by immunomagnetic negative selection using CD4 or CD8 EasySep Mouse T Cell Isolation Kit (STEMCELL Technologies) and then stimulated with plate-bound anti-CD3 (145-2C11; Exbio) and soluble anti-CD28 (37–51; Exbio) antibodies or with phorbol 12-myristate 13-acetate and ionomycin. .. CellTiter-Glo Luminescent Cell Viability Assay (Promega) was used for assessing T cell proliferation.

Article Title: CD56 on intratumoral NK cells: orchestrating NK cell-mediated anti-tumor effects in bladder cancer
Article Snippet: .. To ensure a completely homogeneous T24-CD56KO cell line, the single colonies were depleted using the EasySep PE Positive Selection Kit (StemCell Technologies). ..

Article Title: Sustained and specific multiplexed immune checkpoint modulation in CAR T cells induced by targeted epigenome editing
Article Snippet: Peripheral blood mononuclear cells (PBMCs) from at least three different healthy donors were obtained from leukoreduction system (LRS) chambers by density gradient separation using Biocoll (Bio&SELL, Nuremberg, Germany). .. Primary T cells were obtained from PBMCs either by enrichment after activation or by negative selection using the EasySep Human T cell Isolation Kit (Stemcell technologies, Vancouver, Canada) to obtain a pure CD3 + cell population. .. The cells were cultured in RPMI complete medium, which includes RPMI 1640 GlutaMAX (Life technologies, Carlsbad, California), 10% FBS (PAN Biotech, Aidenbach, Germany), 1X penicillin-streptomycin, and 10 mM HEPES buffer (Sigma-Aldrich, San Luis, Missouri).

Article Title: Protocol for phenotyping and isolation of dendritic cell subsets from blood and lymphoid organs of non-human primates and humans by flow cytometry
Article Snippet: LIVE/DEAD fixable blue dead , Fisher Scientific , Cat# 10114812. .. EasySep PE positive selection kit II , STEMCELL , Cat# 17684. .. EasyEights EasySep magnet , STEMCELL , Cat# 18103.

other:

Article Title: Intravesical VSVd51-GM-CSF virotherapy is superior to BCG in treating bladder cancer in preclinical and translational models
Article Snippet: Human monocytes were isolated from peripheral blood (human CD14 + isolation kit, STEMCELL).

Article Title: Effectorless Fc-fusion improves FLT3L drug-like properties for cancer immunotherapy combinations
Article Snippet: Plates were incubated for 10 min and luminescence was measured with a SpectraMax i3 plate reader (Molecular Device).

Article Title: A CARMIL2 gain-of-function mutation suffices to trigger most CD28 costimulatory functions in vivo
Article Snippet: Naive CD8 + T cells were purified from OT-I, OT-I Carmil 2 −/− , and OT-I Carmil2 QE mice by immunomagnetic negative selection using EasySep Mouse Naive CD8 + T Cell Isolation Kit (STEMCELL Technologies).

Purification:

Article Title: A CARMIL2 gain-of-function mutation suffices to trigger most CD28 costimulatory functions in vivo
Article Snippet: Jurkat T cells were analyzed using anti-CD3 (OKT3), anti-CD28 (CD28.2), and anti-CD69 (FN50), all from BD. .. CD4 + and CD8 + T cells were purified by immunomagnetic negative selection using CD4 or CD8 EasySep Mouse T Cell Isolation Kit (STEMCELL Technologies) and then stimulated with plate-bound anti-CD3 (145-2C11; Exbio) and soluble anti-CD28 (37–51; Exbio) antibodies or with phorbol 12-myristate 13-acetate and ionomycin. .. CellTiter-Glo Luminescent Cell Viability Assay (Promega) was used for assessing T cell proliferation.

Cell Isolation:

Article Title: A CARMIL2 gain-of-function mutation suffices to trigger most CD28 costimulatory functions in vivo
Article Snippet: Jurkat T cells were analyzed using anti-CD3 (OKT3), anti-CD28 (CD28.2), and anti-CD69 (FN50), all from BD. .. CD4 + and CD8 + T cells were purified by immunomagnetic negative selection using CD4 or CD8 EasySep Mouse T Cell Isolation Kit (STEMCELL Technologies) and then stimulated with plate-bound anti-CD3 (145-2C11; Exbio) and soluble anti-CD28 (37–51; Exbio) antibodies or with phorbol 12-myristate 13-acetate and ionomycin. .. CellTiter-Glo Luminescent Cell Viability Assay (Promega) was used for assessing T cell proliferation.

Article Title: Sustained and specific multiplexed immune checkpoint modulation in CAR T cells induced by targeted epigenome editing
Article Snippet: Peripheral blood mononuclear cells (PBMCs) from at least three different healthy donors were obtained from leukoreduction system (LRS) chambers by density gradient separation using Biocoll (Bio&SELL, Nuremberg, Germany). .. Primary T cells were obtained from PBMCs either by enrichment after activation or by negative selection using the EasySep Human T cell Isolation Kit (Stemcell technologies, Vancouver, Canada) to obtain a pure CD3 + cell population. .. The cells were cultured in RPMI complete medium, which includes RPMI 1640 GlutaMAX (Life technologies, Carlsbad, California), 10% FBS (PAN Biotech, Aidenbach, Germany), 1X penicillin-streptomycin, and 10 mM HEPES buffer (Sigma-Aldrich, San Luis, Missouri).

Activation Assay:

Article Title: Sustained and specific multiplexed immune checkpoint modulation in CAR T cells induced by targeted epigenome editing
Article Snippet: Peripheral blood mononuclear cells (PBMCs) from at least three different healthy donors were obtained from leukoreduction system (LRS) chambers by density gradient separation using Biocoll (Bio&SELL, Nuremberg, Germany). .. Primary T cells were obtained from PBMCs either by enrichment after activation or by negative selection using the EasySep Human T cell Isolation Kit (Stemcell technologies, Vancouver, Canada) to obtain a pure CD3 + cell population. .. The cells were cultured in RPMI complete medium, which includes RPMI 1640 GlutaMAX (Life technologies, Carlsbad, California), 10% FBS (PAN Biotech, Aidenbach, Germany), 1X penicillin-streptomycin, and 10 mM HEPES buffer (Sigma-Aldrich, San Luis, Missouri).



Similar Products

90
STEMCELL Technologies Inc mouse cd25 treg cell positive selection kit
Mouse Cd25 Treg Cell Positive Selection Kit, supplied by STEMCELL Technologies Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mouse+treg+selection+kit/mouse+cd25+regulatory+t+cell+positive+selection+kit/pm40249873-51-19-26
Average 90 stars, based on 1 article reviews
mouse cd25 treg cell positive selection kit - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
STEMCELL Technologies Inc easyseptm mouse treg positive selection kit
Flow cytometric analysis of the purity of sorted CD4 + CD25 high+ thymocytes and splenocytes after negative selection of CD4 + cells followed by CD25 + positive selection of <t>Treg</t> cells. Foxp3 intracellular staining was used to test the purity of Treg subpopulations. The figure shows representative flow cytometric plots
Easyseptm Mouse Treg Positive Selection Kit, supplied by STEMCELL Technologies Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mouse+treg+selection+kit/easyseptm+mouse+treg+enrichment+kit/pmc07527366-60-23-29
Average 90 stars, based on 1 article reviews
easyseptm mouse treg positive selection kit - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

96
Miltenyi Biotec macstm mouse treg selection kit
Flow cytometric analysis of the purity of sorted CD4 + CD25 high+ thymocytes and splenocytes after negative selection of CD4 + cells followed by CD25 + positive selection of <t>Treg</t> cells. Foxp3 intracellular staining was used to test the purity of Treg subpopulations. The figure shows representative flow cytometric plots
Macstm Mouse Treg Selection Kit, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mouse+treg+selection+kit/CD4%2BCD25%2B+Regulatory+T+Cell+Isolation+Kit%2C+mouse/pm31542859-56-7-12
Average 96 stars, based on 1 article reviews
macstm mouse treg selection kit - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

90
STEMCELL Technologies Inc easysep mouse cd25 treg positive selection kit
Flow cytometric analysis of the purity of sorted CD4 + CD25 high+ thymocytes and splenocytes after negative selection of CD4 + cells followed by CD25 + positive selection of <t>Treg</t> cells. Foxp3 intracellular staining was used to test the purity of Treg subpopulations. The figure shows representative flow cytometric plots
Easysep Mouse Cd25 Treg Positive Selection Kit, supplied by STEMCELL Technologies Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mouse+treg+selection+kit/easysep+human+t+cell+isolation+kit/pm30612787-75-23-30
Average 90 stars, based on 1 article reviews
easysep mouse cd25 treg positive selection kit - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

96
Miltenyi Biotec mouse treg selection kit
Flow cytometric analysis of the purity of sorted CD4 + CD25 high+ thymocytes and splenocytes after negative selection of CD4 + cells followed by CD25 + positive selection of <t>Treg</t> cells. Foxp3 intracellular staining was used to test the purity of Treg subpopulations. The figure shows representative flow cytometric plots
Mouse Treg Selection Kit, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mouse+treg+selection+kit/CD4%2BCD25%2B+Regulatory+T+Cell+Isolation+Kit%2C+mouse/pmc05940497-123-31-30
Average 96 stars, based on 1 article reviews
mouse treg selection kit - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

Image Search Results


Flow cytometric analysis of the purity of sorted CD4 + CD25 high+ thymocytes and splenocytes after negative selection of CD4 + cells followed by CD25 + positive selection of Treg cells. Foxp3 intracellular staining was used to test the purity of Treg subpopulations. The figure shows representative flow cytometric plots

Journal: Apoptosis

Article Title: Regulatory T cells are less sensitive to glucocorticoid hormone induced apoptosis than CD4 + T cells

doi: 10.1007/s10495-020-01629-x

Figure Lengend Snippet: Flow cytometric analysis of the purity of sorted CD4 + CD25 high+ thymocytes and splenocytes after negative selection of CD4 + cells followed by CD25 + positive selection of Treg cells. Foxp3 intracellular staining was used to test the purity of Treg subpopulations. The figure shows representative flow cytometric plots

Article Snippet: In some experiments the CD4 + T cells were subjected to further positive selection to obtain CD4 + CD25 + Treg cells using EasySepTM Mouse Treg Positive Selection Kit (Stemcell Technologies, Vancouver, Canada) following the manufacturer’s instructions.

Techniques: Selection, Staining

a Treg cells express higher level of apoptosis-related proteins than CD4 + T cells. Analysis of 21 apoptosis-related protein expression in the cell lysates of untreated, sorted pTreg cells and CD4 + splenocytes. Bars show the average OD values of each analyte from at least three independent experiments (n = 6). b Effect of DX treatment on the expression of 21 apoptosis-related molecules in T cell subpopulations. Protein arrays were used to detect the in vitro DX treatment (4 h) induced changes of apoptosis-related molecules in cell lysates of sorted CD4 + T cells and pTreg cells. Bars show the DX-induced relative changes (%) of the average OD values of each analyte compared to untreated controls from at least three independent experiments (n = 6). Relative changes were calculated with the following formula: [(OD DX – OD Ctrl )/OD Ctrl ] × 100%

Journal: Apoptosis

Article Title: Regulatory T cells are less sensitive to glucocorticoid hormone induced apoptosis than CD4 + T cells

doi: 10.1007/s10495-020-01629-x

Figure Lengend Snippet: a Treg cells express higher level of apoptosis-related proteins than CD4 + T cells. Analysis of 21 apoptosis-related protein expression in the cell lysates of untreated, sorted pTreg cells and CD4 + splenocytes. Bars show the average OD values of each analyte from at least three independent experiments (n = 6). b Effect of DX treatment on the expression of 21 apoptosis-related molecules in T cell subpopulations. Protein arrays were used to detect the in vitro DX treatment (4 h) induced changes of apoptosis-related molecules in cell lysates of sorted CD4 + T cells and pTreg cells. Bars show the DX-induced relative changes (%) of the average OD values of each analyte compared to untreated controls from at least three independent experiments (n = 6). Relative changes were calculated with the following formula: [(OD DX – OD Ctrl )/OD Ctrl ] × 100%

Article Snippet: In some experiments the CD4 + T cells were subjected to further positive selection to obtain CD4 + CD25 + Treg cells using EasySepTM Mouse Treg Positive Selection Kit (Stemcell Technologies, Vancouver, Canada) following the manufacturer’s instructions.

Techniques: Expressing, In Vitro

Effect of DX on basal Ca 2+ levels in tTreg and pTreg cells. Short-term (30 min) DX treatment induced elevation of basal cytosolic free Ca 2+ levels in thymic Treg cells. In both organs, the baseline Ca 2+ levels were higher in Treg cells than in the corresponding CD4 + T cells. The columns show the Fluo 3-AM fluorescence intensities (MFI) of Tregs minus MFI of CD4 + T cells. Data represent mean ± SEM (n = 4). Significant change is indicated with asterisk ( p < 0.05)

Journal: Apoptosis

Article Title: Regulatory T cells are less sensitive to glucocorticoid hormone induced apoptosis than CD4 + T cells

doi: 10.1007/s10495-020-01629-x

Figure Lengend Snippet: Effect of DX on basal Ca 2+ levels in tTreg and pTreg cells. Short-term (30 min) DX treatment induced elevation of basal cytosolic free Ca 2+ levels in thymic Treg cells. In both organs, the baseline Ca 2+ levels were higher in Treg cells than in the corresponding CD4 + T cells. The columns show the Fluo 3-AM fluorescence intensities (MFI) of Tregs minus MFI of CD4 + T cells. Data represent mean ± SEM (n = 4). Significant change is indicated with asterisk ( p < 0.05)

Article Snippet: In some experiments the CD4 + T cells were subjected to further positive selection to obtain CD4 + CD25 + Treg cells using EasySepTM Mouse Treg Positive Selection Kit (Stemcell Technologies, Vancouver, Canada) following the manufacturer’s instructions.

Techniques: Fluorescence

Calcium response is low in thymic and splenic Treg cells. Effect of TCR (anti-CD3) stimulation in thymic CD4 SP and tTreg cells was measured in the presence or absence of DX ( a ). Calcium influx kinetics in splenic CD4 + and Treg cells upon specific TCR-mediated activation (anti-CD3) in the presence or absence of DX ( b ). Data were calculated as the relative ratio of calcium values of Fluo 3-AM fluorescence intensities (median). Columns show the relative ratio of peak to baseline calcium flux measured as Fluo 3-AM fluorescence intensities (MFI) ( c ). The graphs show the mean ± SEM of at least three independent experiments (n = 9). Significant changes are indicated with asterisk (* p < 0.05, ***p < 0.001)

Journal: Apoptosis

Article Title: Regulatory T cells are less sensitive to glucocorticoid hormone induced apoptosis than CD4 + T cells

doi: 10.1007/s10495-020-01629-x

Figure Lengend Snippet: Calcium response is low in thymic and splenic Treg cells. Effect of TCR (anti-CD3) stimulation in thymic CD4 SP and tTreg cells was measured in the presence or absence of DX ( a ). Calcium influx kinetics in splenic CD4 + and Treg cells upon specific TCR-mediated activation (anti-CD3) in the presence or absence of DX ( b ). Data were calculated as the relative ratio of calcium values of Fluo 3-AM fluorescence intensities (median). Columns show the relative ratio of peak to baseline calcium flux measured as Fluo 3-AM fluorescence intensities (MFI) ( c ). The graphs show the mean ± SEM of at least three independent experiments (n = 9). Significant changes are indicated with asterisk (* p < 0.05, ***p < 0.001)

Article Snippet: In some experiments the CD4 + T cells were subjected to further positive selection to obtain CD4 + CD25 + Treg cells using EasySepTM Mouse Treg Positive Selection Kit (Stemcell Technologies, Vancouver, Canada) following the manufacturer’s instructions.

Techniques: Activation Assay, Fluorescence