Review



oral microbiome whole cell mix  (ATCC)


Bioz Verified Symbol ATCC is a verified supplier
Bioz Manufacturer Symbol ATCC manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 92

    Structured Review

    ATCC oral microbiome whole cell mix
    Oral Microbiome Whole Cell Mix, supplied by ATCC, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microbiome/Oral+Microbiome%3B+Whole+Cell+Mix/pmc11225822-296-0-5
    Average 92 stars, based on 1 article reviews
    oral microbiome whole cell mix - by Bioz Stars, 2026-11
    92/100 stars

    Images

    Related Articles

    Positive Control:

    Article Title: Single-cell view into the role of microbiota shaping host immunity in the larynx
    Article Snippet: .. Oral Microbiome Whole Cell Mix (ATCC, Manassas, VA) (Oral, n=4) was included as positive control, processed, and sequenced in parallel with tissue samples, to examine the effectiveness of sample/data processing methods. .. The mock community was a defined synthetic community comprised of equal portion of Schaalia odontolytica ( ATCC 17982 ), Prevotella melaninogenica ( ATCC 25845 ), Fusobacterium nucleatum subsp. nucleatumStreptococcus mitis ( ATCC 49456 ), Veillonella parvula ( ATCC 17745 ), and Haemophilus parainfluenzae ( ATCC 33392 ), with each representing 16.7% of the total cells.

    Article Title: Age and sex-related variations in murine laryngeal microbiota.
    Article Snippet: PCR Amplicons were confirmed on 1.5% agarose gel, and amplicon concentration was subsequently quantified with a Qubit1 Fluorometer (Invitrogen, San Diego, CA, United States). .. Oral Microbiome Whole Cell Mix (ATCC, Manassas, VA) (n = 4) was included as positive control, processed, and sequenced in parallel with tissue samples, to examine the effectiveness of sample/data processing methods. .. The mock community was a defined synthetic community comprised of equal portions of Schaalia odontolytica (ATCC 17982), Prevotella melaninogenica (ATCC 25845), Fusobacterium nucleatum subsp. nucleatum (ATCC 25586), Streptococcus mitis (ATCC 49456), Veillonella parvula (ATCC 17745), and Haemophilus parainfluenzae (ATCC 33392), with each representing 16.7% of total cells.

    Article Title: Effects of psychosocial stress on laryngeal microbiology and epithelial barrier integrity
    Article Snippet: .. The Oral Microbiome Whole Cell Mix (ATCC, Manassas, VA) was used as positive control, processed with tissue samples to test data collection/analysis effectiveness. ..

    Article Title: Effects of psychosocial stress on laryngeal microbiology and epithelial barrier integrity.
    Article Snippet: .. The Oral Microbiome Whole Cell Mix (ATCC, Manassas, VA) was used as positive control, processed with tissue samples to test data collection/ analysis effectiveness. ..

    Article Title: Age and sex-related variations in murine laryngeal microbiota
    Article Snippet: PCR Amplicons were confirmed on 1.5% agarose gel, and amplicon concentration was subsequently quantified with a Qubit® Fluorometer (Invitrogen, San Diego, CA, United States). .. Oral Microbiome Whole Cell Mix (ATCC, Manassas, VA) (n = 4) was included as positive control, processed, and sequenced in parallel with tissue samples, to examine the effectiveness of sample/data processing methods. .. The mock community was a defined synthetic community comprised of equal portions of Schaalia odontolytica ( ATCC 17982 ), Prevotella melaninogenica ( ATCC 25845 ), Fusobacterium nucleatum subsp. nucleatum ( ATCC 25586 ), Streptococcus mitis ( ATCC 49456 ), Veillonella parvula ( ATCC 17745 ), and Haemophilus parainfluenzae ( ATCC 33392 ), with each representing 16.7% of total cells.

    Polymerase Chain Reaction:

    Article Title: Associations and recovery dynamics of the nasopharyngeal microbiota during influenza-like illness in the aging population
    Article Snippet: The rRNA V4 region of the 16S rRNA gene was amplified by PCR using the 515F (5’-GTG CCA GCM GCC GCG GTA A-3’) and 806R (5’-GGA CTA CHV GGG TWT CTA AT-3’) primers including the Illumina adapters and sample specific barcodes [ , ]. .. For PCR, we included additional DNA mocks, ATCC-MSA-2004 and an in-house DNA mock consisting of Haemophilus influenzae, Streptococcus pneumoniae, Streptococcus pyogenes (group B), Klebsiella oxytoca, Klebsiella pneumoniae , Hemolytic Streptococcus Group A, Pseudomonas aeruginosa, Staphylococcus epidermidis, Staphylococcus aureus and Moraxella catarrhalis pooled in equal ratios based on 16S rRNA gene qPCR data. .. Overall, DNA blanks, non-template controls (NTC), ZymoBIOMICS Microbial Community Standard (whole cell) and gDNA mocks were included in each PCR plate and sequenced alongside the samples sequenced with an Illumina MiSeq instrument (Illumina Inc., San Diego, CA, US) following manufacturer’s recommendations.

    Article Title: Associations and recovery dynamics of the nasopharyngeal microbiota during influenza-like illness in the aging population
    Article Snippet: The rRNA V4 region of the 16S rRNA gene was amplified by dual-index PCR using the 515F (5′-GTG CCA GCM GCC GCG GTA A-3′) and 806R (5′-GGA CTA CHV GGG TWT CTA AT-3′) primers including the Illumina adapters and sample specific barcodes , . .. For PCR, we included additional DNA mocks, ATCC-MSA-2004 and an in-house DNA mock consisting of Haemophilus influenzae , Streptococcus pneumoniae , Streptococcus pyogenes (group B), Klebsiella oxytoca , Klebsiella pneumoniae , Hemolytic Streptococcus Group A, Pseudomonas aeruginosa , Staphylococcus epidermidis , Staphylococcus aureus and Moraxella catarrhalis pooled in equal ratios based on 16S rRNA gene qPCR data. .. Overall, DNA blanks, non-template controls (NTC), ZymoBIOMICS Microbial Community Standard (whole cell) and gDNA mocks were included in each PCR plate and sequenced alongside the samples sequenced (2 × 250 bp) with an Illumina MiSeq instrument (Illumina Inc., San Diego, CA, US) using MiSeq v2 (500 cycles) reagent kit following manufacturer’s recommendations.

    Real-time Polymerase Chain Reaction:

    Article Title: Associations and recovery dynamics of the nasopharyngeal microbiota during influenza-like illness in the aging population
    Article Snippet: The rRNA V4 region of the 16S rRNA gene was amplified by PCR using the 515F (5’-GTG CCA GCM GCC GCG GTA A-3’) and 806R (5’-GGA CTA CHV GGG TWT CTA AT-3’) primers including the Illumina adapters and sample specific barcodes [ , ]. .. For PCR, we included additional DNA mocks, ATCC-MSA-2004 and an in-house DNA mock consisting of Haemophilus influenzae, Streptococcus pneumoniae, Streptococcus pyogenes (group B), Klebsiella oxytoca, Klebsiella pneumoniae , Hemolytic Streptococcus Group A, Pseudomonas aeruginosa, Staphylococcus epidermidis, Staphylococcus aureus and Moraxella catarrhalis pooled in equal ratios based on 16S rRNA gene qPCR data. .. Overall, DNA blanks, non-template controls (NTC), ZymoBIOMICS Microbial Community Standard (whole cell) and gDNA mocks were included in each PCR plate and sequenced alongside the samples sequenced with an Illumina MiSeq instrument (Illumina Inc., San Diego, CA, US) following manufacturer’s recommendations.

    Article Title: Associations and recovery dynamics of the nasopharyngeal microbiota during influenza-like illness in the aging population
    Article Snippet: The rRNA V4 region of the 16S rRNA gene was amplified by dual-index PCR using the 515F (5′-GTG CCA GCM GCC GCG GTA A-3′) and 806R (5′-GGA CTA CHV GGG TWT CTA AT-3′) primers including the Illumina adapters and sample specific barcodes , . .. For PCR, we included additional DNA mocks, ATCC-MSA-2004 and an in-house DNA mock consisting of Haemophilus influenzae , Streptococcus pneumoniae , Streptococcus pyogenes (group B), Klebsiella oxytoca , Klebsiella pneumoniae , Hemolytic Streptococcus Group A, Pseudomonas aeruginosa , Staphylococcus epidermidis , Staphylococcus aureus and Moraxella catarrhalis pooled in equal ratios based on 16S rRNA gene qPCR data. .. Overall, DNA blanks, non-template controls (NTC), ZymoBIOMICS Microbial Community Standard (whole cell) and gDNA mocks were included in each PCR plate and sequenced alongside the samples sequenced (2 × 250 bp) with an Illumina MiSeq instrument (Illumina Inc., San Diego, CA, US) using MiSeq v2 (500 cycles) reagent kit following manufacturer’s recommendations.



    Similar Products

    97
    Transnetyx microbiome
    Microbiome, supplied by Transnetyx, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microbiome/Microbiome/bio_rxiv__64898__2026__11__05__764678-66-3-19
    Average 97 stars, based on 1 article reviews
    microbiome - by Bioz Stars, 2026-11
    97/100 stars
      Buy from Supplier

    97
    Zymo Research zymobiomics gut microbiome standard
    Zymobiomics Gut Microbiome Standard, supplied by Zymo Research, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microbiome/ZYMOBIOMICS+GUT+MICROBIOME+STANDARD/pm42992936-141-1-7
    Average 97 stars, based on 1 article reviews
    zymobiomics gut microbiome standard - by Bioz Stars, 2026-11
    97/100 stars
      Buy from Supplier

    99
    Zymo Research zymobiomics microbial community standard
    Zymobiomics Microbial Community Standard, supplied by Zymo Research, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microbiome/ZymoBIOMICS+Microbial+Community+Standard/pmc13773292-73-1-5
    Average 99 stars, based on 1 article reviews
    zymobiomics microbial community standard - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    97
    Qiagen rneasy power microbiome kit
    Six commercially available methods were used to extract nucleic acid from the ZymoBIOMICS <t>Microbial</t> <t>Community</t> Standard, and libraries were sequenced using the NexteraXT kit and Illumina NovaSeq platform. The Aitchison distance between the fraction of bases mapping to each species in the NGS datasets compared to the expected input was calculated for each method. An Aitchison distance of zero indicates no difference in community composition compared to the input. Variation introduced by library preparation was evaluated using the ZymoBIOMICS Microbial Community DNA Standard. Libraries were prepared from the nucleic acid standard using four different methods, and the libraries were sequenced on either the Illumina NextSeq or the ONT MinION, as appropriate for the library method.
    Rneasy Power Microbiome Kit, supplied by Qiagen, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microbiome/RNeasy+PowerMicrobiome+Kit/pmc13773292-75-23-22
    Average 97 stars, based on 1 article reviews
    rneasy power microbiome kit - by Bioz Stars, 2026-11
    97/100 stars
      Buy from Supplier

    97
    Qiagen qiaamp dna microbiome kit
    Six commercially available methods were used to extract nucleic acid from the ZymoBIOMICS <t>Microbial</t> <t>Community</t> Standard, and libraries were sequenced using the NexteraXT kit and Illumina NovaSeq platform. The Aitchison distance between the fraction of bases mapping to each species in the NGS datasets compared to the expected input was calculated for each method. An Aitchison distance of zero indicates no difference in community composition compared to the input. Variation introduced by library preparation was evaluated using the ZymoBIOMICS Microbial Community DNA Standard. Libraries were prepared from the nucleic acid standard using four different methods, and the libraries were sequenced on either the Illumina NextSeq or the ONT MinION, as appropriate for the library method.
    Qiaamp Dna Microbiome Kit, supplied by Qiagen, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microbiome/QIAamp+DNA+Microbiome+Kit/pmc13759983-22-9-13
    Average 97 stars, based on 1 article reviews
    qiaamp dna microbiome kit - by Bioz Stars, 2026-11
    97/100 stars
      Buy from Supplier

    95
    Zymo Research microbial community dna standard ii
    Six commercially available methods were used to extract nucleic acid from the ZymoBIOMICS <t>Microbial</t> <t>Community</t> Standard, and libraries were sequenced using the NexteraXT kit and Illumina NovaSeq platform. The Aitchison distance between the fraction of bases mapping to each species in the NGS datasets compared to the expected input was calculated for each method. An Aitchison distance of zero indicates no difference in community composition compared to the input. Variation introduced by library preparation was evaluated using the ZymoBIOMICS Microbial Community DNA Standard. Libraries were prepared from the nucleic acid standard using four different methods, and the libraries were sequenced on either the Illumina NextSeq or the ONT MinION, as appropriate for the library method.
    Microbial Community Dna Standard Ii, supplied by Zymo Research, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microbiome/ZymoBIOMICS+Microbial+Community+Standard+II+(Log+Distribution)/10__1038_slash_s41598___026___79345___w-51-4-10
    Average 95 stars, based on 1 article reviews
    microbial community dna standard ii - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    99
    Zymo Research zymo d6300
    Summary of datasets used for evaluation
    Zymo D6300, supplied by Zymo Research, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microbiome/ZymoBIOMICS+Microbial+Community+Standard/pmc13760973-7-0-0
    Average 99 stars, based on 1 article reviews
    zymo d6300 - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Zymo Research positive bacterial mock community controls
    Summary of datasets used for evaluation
    Positive Bacterial Mock Community Controls, supplied by Zymo Research, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microbiome/ZymoBIOMICS+Microbial+Community+DNA+Standard/pm42989121-88-3-13
    Average 99 stars, based on 1 article reviews
    positive bacterial mock community controls - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    Image Search Results


    Six commercially available methods were used to extract nucleic acid from the ZymoBIOMICS Microbial Community Standard, and libraries were sequenced using the NexteraXT kit and Illumina NovaSeq platform. The Aitchison distance between the fraction of bases mapping to each species in the NGS datasets compared to the expected input was calculated for each method. An Aitchison distance of zero indicates no difference in community composition compared to the input. Variation introduced by library preparation was evaluated using the ZymoBIOMICS Microbial Community DNA Standard. Libraries were prepared from the nucleic acid standard using four different methods, and the libraries were sequenced on either the Illumina NextSeq or the ONT MinION, as appropriate for the library method.

    Journal: PLOS One

    Article Title: Experimental and computational insights for broad, metagenomic next-generation sequencing-based biodetection in complex environments

    doi: 10.1371/journal.pone.0361775

    Figure Lengend Snippet: Six commercially available methods were used to extract nucleic acid from the ZymoBIOMICS Microbial Community Standard, and libraries were sequenced using the NexteraXT kit and Illumina NovaSeq platform. The Aitchison distance between the fraction of bases mapping to each species in the NGS datasets compared to the expected input was calculated for each method. An Aitchison distance of zero indicates no difference in community composition compared to the input. Variation introduced by library preparation was evaluated using the ZymoBIOMICS Microbial Community DNA Standard. Libraries were prepared from the nucleic acid standard using four different methods, and the libraries were sequenced on either the Illumina NextSeq or the ONT MinION, as appropriate for the library method.

    Article Snippet: Six commercially available nucleic acid extraction kits were included in this analysis: the Qiagen DNeasy PowerSoil Pro kit (n = 5), the Qiagen RNeasy Power Microbiome kit (now discontinued, n = 5), the MP Biomedical FastDNA kit (n = 5), the Qiagen RNeasy PowerFecal Pro kit (n = 2), and the Zymo MiniPrep kit following the protocols for total nucleic acid extraction (n = 1) or DNA extraction (n = 1).

    Techniques:

    Summary of datasets used for evaluation

    Journal: iScience

    Article Title: Multi-scale hybrid correction of noisy long reads

    doi: 10.1016/j.isci.2026.118150

    Figure Lengend Snippet: Summary of datasets used for evaluation

    Article Snippet: Zymo D6300 , Real , Mock community containing eight bacterial and two yeast strains , ONT R9.4.1; 10% subset ( ∼ 18.73 × ) , Illumina; ∼ 34.56 × , Correction performance benchmark; Comparison with self-correction tools using additional subsets (5%–40% subsets)..

    Techniques: Yeast, Comparison