Review



custom-built two-photon laser scanning microscope  (Evident Corporation)

 
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Evident Corporation custom-built two-photon laser scanning microscope
    Custom Built Two Photon Laser Scanning Microscope, supplied by Evident Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/matlab-based+scanimage+software/two+photon+microscope/pmc03531664-286-6-15
    Average 90 stars, based on 1 article reviews
    custom-built two-photon laser scanning microscope - by Bioz Stars, 2026-11
    90/100 stars

    Images

    Related Articles

    Laser-Scanning Microscopy:

    Article Title: Small molecule inhibitor DDQ-treated hippocampal neuronal cells show improved neurite outgrowth and synaptic branching
    Article Snippet: .. Using a multiphoton laser scanning microscope equipment, pictures were captured (Olympus IX83). .. Using a multiphoton laser scanning microscope equipment, pictures were captured (Olympus IX83).

    Article Title: Multicompartmentalized Microvascularized Tumor-on-a-Chip to Study Tumor-Stroma Interactions and Drug Resistance in Ovarian Cancer.
    Article Snippet: .. A similar approach was taken to study the differences in collagen fiber orientation in the different stromal scenarios for both control and halofuginone-treated groups in the microfluidic device by second harmonic generation microscopy (SHG) using FLUOVIEW FVMPE-RS Multi Photon Laser Scanning Microscope (Olympus). .. A tunable laser (InSight, SpectraPhysics) was used at 840 nm and z-stacks of 50 μm with a step size of 1 μm in 2 different positions of the stromal chamber in the microfluidic device were acquired using 25x water-immersion objective.

    Control:

    Article Title: Multicompartmentalized Microvascularized Tumor-on-a-Chip to Study Tumor-Stroma Interactions and Drug Resistance in Ovarian Cancer.
    Article Snippet: .. A similar approach was taken to study the differences in collagen fiber orientation in the different stromal scenarios for both control and halofuginone-treated groups in the microfluidic device by second harmonic generation microscopy (SHG) using FLUOVIEW FVMPE-RS Multi Photon Laser Scanning Microscope (Olympus). .. A tunable laser (InSight, SpectraPhysics) was used at 840 nm and z-stacks of 50 μm with a step size of 1 μm in 2 different positions of the stromal chamber in the microfluidic device were acquired using 25x water-immersion objective.

    Microscopy:

    Article Title: Multicompartmentalized Microvascularized Tumor-on-a-Chip to Study Tumor-Stroma Interactions and Drug Resistance in Ovarian Cancer.
    Article Snippet: .. A similar approach was taken to study the differences in collagen fiber orientation in the different stromal scenarios for both control and halofuginone-treated groups in the microfluidic device by second harmonic generation microscopy (SHG) using FLUOVIEW FVMPE-RS Multi Photon Laser Scanning Microscope (Olympus). .. A tunable laser (InSight, SpectraPhysics) was used at 840 nm and z-stacks of 50 μm with a step size of 1 μm in 2 different positions of the stromal chamber in the microfluidic device were acquired using 25x water-immersion objective.

    Article Title: Identification of cortical arteries and veins in awake mice using two-photon microscopy.
    Article Snippet: Cortical artery–vein separation in vivo is essential for basic research including hemodynamics (Nishimura et al., 2007; Sugashi et al., 2014), oxygen concentration (Lyons et al., 2016; Sakadzic et al., 2016), and angiogenesis (Masamoto et al., 2013).. It is also highly valuable in the clinical assessment, diagnosis, and treatment of various vascular diseases, such as stroke (Liu et al., 2018; Park et al., 2008), hypertension (Naessens et al., 2020), cerebral hemorrhage (Oyama et al., 2013), and aneurysm (Hussein et al., 2018).. Therefore, an effective method is urgently needed to distinguish between arteries and veins from cerebral cortical blood vessels.

    other:

    Article Title: The choroid plexus synergizes with immune cells during neuroinflammation.
    Article Snippet: REAGENT or RESOURCE SOURCE IDENTIFIER DNase1 Worthington Biochemical Cat# LS002007 F4/80-PE BioLegend Cat# 157340 Fluoromount-G Southern Biotech Cat# 00-4958-02 GM6001 MMP Inhibitor Tocris Bioscience Cat# 2983 HEPES Millipore Sigma Cat# 83264-100ML-F KIRAVIA Blue 520 Streptavidin BioLegend Cat# 405172 LEGENDplex Mouse Inflammation Panel BioLegend Cat# 740446 Lipopolysaccharides Millipore Sigma Cat# L3024 Paraformaldehyde Millipore Sigma Cat# P6148 Tamoxifen Thermo Fisher Cat# 4306311 Triptolide Millipore Sigma Cat# T3652 Critical commercial assays Chromium Next GEM Single Cell 3’ Reagent Kits, Dual Index, V3.1 10x Genomics Cat# PN-1000269 Chromium Next GEM Chip G Single Cell Kit 10x Genomics Cat# PN-1000127 3’ Feature Barcode Kit 10x Genomics Cat# PN-1000262 Dual Index Kit TT Set A 10x Genomics Cat# PN-1000215 Dual Index Kit NT Set A 10x Genomics Cat# PN-1000242 Deposited data ChP scRNAseq GEO GEO: GSE239318 CSF scRNAseq GEO GEO: GSE239318 Experimental models: Organisms/strains Ai14, tdTomato reporter JAX Laboratory 007914 Ai6, ZsGreen reporter JAX Laboratory 007906 C57BL6 JAX Laboratory 000664 TtrmNeonGreen Fame et al.31 N/A Ccr2RFP JAX Laboratory 017586 Cx3cr1CreER JAX Laboratory 020940 Cx3cr1GFP JAX Laboratory 005582 Ly2Cre JAX Laboratory 004781 Software and algorithms Cell Ranger 10x Genomics V3.1.0 FIJI/ ImageJ Schindelin et al.86 http://imagej.net/Fiji;https://imagej.nih.gov FlowJo BD Biosciences v10 MATLAB MathWorks R2020b Prism GraphPad v7 Two-photon microscopy Olympus FVMPE-RS ZEN Black/Blue Zeiss N/A ImageStream Cytek N/A ll OPEN ACCESS Please cite this article in press as: Xu et al., The choroid plexus synergizes with immune cells during neuroinflammation, Cell (2024), https:// doi.org/10.1016/j.cell.2024.07.002 Article

    Article Title: Quinolines that modulate SERCA and their use for treating disease
    Article Snippet: Ca2+ Imaging: Ca2+ imaging within individual neurons was performed in brain slice preparations using a custom-made video-rate multiphoton-imaging system based on an upright Olympus BX51 microscope frame.

    Article Title: Dynamics of directional motor tuning in the primate premotor and primary motor cortices during sensorimotor learning
    Article Snippet: For marmosets 4–6, we conducted two-photon imaging with a custom-built two-photon microscopy system (Olympus, Tokyo, Japan) that is described in ref. . A femtosecond pulse laser (Femtolite FD/J-FD-500; pulse width, 191–194 fs; repetition rate, 51 MHz; wavelength, 920 nm; IMRA, MI, USA) was introduced to the microscope scanning head through a neodymium-based fiber so that X-Y scanning was possible without any tilt effect on the microscope body.

    Article Title: A Regulatory Mechanism on Pathways: Modulating Roles of MYC2 and BBX21 in the Flavonoid Network
    Article Snippet: Interaction of the proteins was examined under fluorescent light and transmitting light with a two-photon fluorescence microscope (Olympus, Tokyo, Japan) and photographed at about 100×.



    Similar Products

    90
    Vidrio Technologies matlab-based scanimage software

    Matlab Based Scanimage Software, supplied by Vidrio Technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/matlab-based+scanimage+software/scanimage+software/pmc10755854-365-52-54
    Average 90 stars, based on 1 article reviews
    matlab-based scanimage software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    Journal: Cell reports

    Article Title: All-optical recreation of naturalistic neural activity with a multifunctional transgenic reporter mouse

    doi: 10.1016/j.celrep.2023.112909

    Figure Lengend Snippet:

    Article Snippet: For 2-photon calcium imaging in vivo in awake animals ( , – , , and ), mice were head-fixed and allowed to run on a freely moving circular treadmill under a 20× magnification (1.0 NA) water-immersion objective (Olympus Corporation) and imaged with a Sutter MOM 2p resonance scanning microscope controlled with MATLAB-based ScanImage software (Vidrio Technologies) (see also microscope design, above, ).

    Techniques: Virus, Recombinant, Software, Activity Assay