Review



ti sapphire laser  (Coherent Corp)


Bioz Verified Symbol Coherent Corp is a verified supplier
Bioz Manufacturer Symbol Coherent Corp manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 99

    Structured Review

    Coherent Corp ti sapphire laser
    Ti Sapphire Laser, supplied by Coherent Corp, used in various techniques. Bioz Stars score: 99/100, based on 9877 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/matlab-based+scanimage+software/Chameleon/pmc03531664-286-20-24
    Average 99 stars, based on 9877 article reviews
    ti sapphire laser - by Bioz Stars, 2026-11
    99/100 stars

    Images

    Related Articles

    other:

    Article Title: Depth-enhanced molecular imaging with two-photon oblique plane microscopy
    Article Snippet: Ti:Sapph , Ti:Sapphire lasers (Coherent Chameleon Ultra I; 680-1040 nm, 2.9 W @800 nm, 80 MHz rep rate, 140 fs pulse duration).

    Second Harmonic Generation Microscopy:

    Article Title: Establishment of a Responsive Tooth-on-a-Chip Platform for the Assessment of Regenerative Factors in Dental Tissue Regeneration.
    Article Snippet: .. Second harmonic generation (SHG) imaging was perormed with a multiphoton microscope (TriMScope II, Miltenyi iotec, Germany) equipped with a Ti:sapphire laser (Chameleon ltra II, Coherent Inc., Santa Clara, CA, USA) and an optical arametric oscillator (MPX OPO, Coherent Inc.) to generate xcitation at 1200 nm with a power of 90–150 mW measured nder the microscope objective. .. Microscopy was performed sing a 25×/1.05 numerical aperture (NA) water-immersion bjective lens (XLPLN25XWMP2, Evident Inc., Tokyo, Japan).

    Imaging:

    Article Title: Establishment of a Responsive Tooth-on-a-Chip Platform for the Assessment of Regenerative Factors in Dental Tissue Regeneration.
    Article Snippet: .. Second harmonic generation (SHG) imaging was perormed with a multiphoton microscope (TriMScope II, Miltenyi iotec, Germany) equipped with a Ti:sapphire laser (Chameleon ltra II, Coherent Inc., Santa Clara, CA, USA) and an optical arametric oscillator (MPX OPO, Coherent Inc.) to generate xcitation at 1200 nm with a power of 90–150 mW measured nder the microscope objective. .. Microscopy was performed sing a 25×/1.05 numerical aperture (NA) water-immersion bjective lens (XLPLN25XWMP2, Evident Inc., Tokyo, Japan).

    Article Title: Distinct prelimbic microcircuits control sensory and affective dimensions of neuropathic pain.
    Article Snippet: .. A two-photon microscope (Lavision Biotech, Trimscope) equipped with a Ti:Sa pulsed laser (Chameleon Ultra, Coherent) and a long-working-distance, high-numerical-aperture objective (Leica ×10, 0.4 NA) was used at 960 nm for fluorescence excitation and imaging. ..

    Article Title: Improving bi-exponential fitting of autofluorescence lifetime decay data through whole-cell binning
    Article Snippet: .. Fluorescence lifetime imaging of the LDH-NADH solution was performed using a custom-built inverted multiphoton fluorescence microscope (Marianas, 3i) equipped with a 40× water-immersion objective (NA 1.1), providing a field of view of ∼ 270 × 270 μ m . NADH was excited at 750 nm using a titanium:sapphire femtosecond laser (Chameleon, COHERENT), with excitation power maintained between 20 and 25 mW. .. Fluorescence lifetime data were acquired using TCSPC electronics (SPC-150N, Becker &Hickl).

    Microscopy:

    Article Title: Establishment of a Responsive Tooth-on-a-Chip Platform for the Assessment of Regenerative Factors in Dental Tissue Regeneration.
    Article Snippet: .. Second harmonic generation (SHG) imaging was perormed with a multiphoton microscope (TriMScope II, Miltenyi iotec, Germany) equipped with a Ti:sapphire laser (Chameleon ltra II, Coherent Inc., Santa Clara, CA, USA) and an optical arametric oscillator (MPX OPO, Coherent Inc.) to generate xcitation at 1200 nm with a power of 90–150 mW measured nder the microscope objective. .. Microscopy was performed sing a 25×/1.05 numerical aperture (NA) water-immersion bjective lens (XLPLN25XWMP2, Evident Inc., Tokyo, Japan).

    Article Title: Microcephaly-causative ASPM mutations disrupt mitotic spindle orientation and timely specification of human outer radial glia cells.
    Article Snippet: .. Confocal images were generated using a Zeiss LSM780 confocal system fitted on an Observer Z1 inverted microscope equipped driven by ZEN 2012 software (Zeiss) and equipped with 5x/0.16, 10x/0.3, 20x/0.8 and 40x/1.1W objectives and a Chameleon Vision II 690–1064 nm multiphoton laser (Coherent Europe), a Nikon TiE A1R laser-scanning confocal microscope equipped with a highdefinition resonant scanner, a piezo nano-drive (Mad City Labs Inc.) and operated via NIS-Elements software (version 5.30, Nikon Instruments Europe B.V.), and a Nikon Ti2 inverted microscope equipped with a Cicero spinning-disk confocal module (CrestOptics S.p.A.) and a Kinetix sCMOS camera (Teledyne Photometrics). .. Widefield tiled images were generated on a Zeiss Axio widefield NL5+ with 5x and 10x objectives.

    Article Title: Metabolic and structural profiling of phosphaturic mesenchymal tumors by multimodal optical spectroscopy: a case study
    Article Snippet: .. FLIM of cell autofluorescence was performed under two-photon excitation at a wavelength of 730 nm using a femtosecond Chameleon Ultra II laser (Coherent, United States) with a FLIM module (Becker & Hickl, Germany) attached to an LSM-710-NLO microscope. ..

    Article Title: Distinct prelimbic microcircuits control sensory and affective dimensions of neuropathic pain.
    Article Snippet: .. A two-photon microscope (Lavision Biotech, Trimscope) equipped with a Ti:Sa pulsed laser (Chameleon Ultra, Coherent) and a long-working-distance, high-numerical-aperture objective (Leica ×10, 0.4 NA) was used at 960 nm for fluorescence excitation and imaging. ..

    Article Title: Improving bi-exponential fitting of autofluorescence lifetime decay data through whole-cell binning
    Article Snippet: .. Fluorescence lifetime imaging of the LDH-NADH solution was performed using a custom-built inverted multiphoton fluorescence microscope (Marianas, 3i) equipped with a 40× water-immersion objective (NA 1.1), providing a field of view of ∼ 270 × 270 μ m . NADH was excited at 750 nm using a titanium:sapphire femtosecond laser (Chameleon, COHERENT), with excitation power maintained between 20 and 25 mW. .. Fluorescence lifetime data were acquired using TCSPC electronics (SPC-150N, Becker &Hickl).

    Confocal:

    Article Title: Microcephaly-causative ASPM mutations disrupt mitotic spindle orientation and timely specification of human outer radial glia cells.
    Article Snippet: .. Confocal images were generated using a Zeiss LSM780 confocal system fitted on an Observer Z1 inverted microscope equipped driven by ZEN 2012 software (Zeiss) and equipped with 5x/0.16, 10x/0.3, 20x/0.8 and 40x/1.1W objectives and a Chameleon Vision II 690–1064 nm multiphoton laser (Coherent Europe), a Nikon TiE A1R laser-scanning confocal microscope equipped with a highdefinition resonant scanner, a piezo nano-drive (Mad City Labs Inc.) and operated via NIS-Elements software (version 5.30, Nikon Instruments Europe B.V.), and a Nikon Ti2 inverted microscope equipped with a Cicero spinning-disk confocal module (CrestOptics S.p.A.) and a Kinetix sCMOS camera (Teledyne Photometrics). .. Widefield tiled images were generated on a Zeiss Axio widefield NL5+ with 5x and 10x objectives.

    Generated:

    Article Title: Microcephaly-causative ASPM mutations disrupt mitotic spindle orientation and timely specification of human outer radial glia cells.
    Article Snippet: .. Confocal images were generated using a Zeiss LSM780 confocal system fitted on an Observer Z1 inverted microscope equipped driven by ZEN 2012 software (Zeiss) and equipped with 5x/0.16, 10x/0.3, 20x/0.8 and 40x/1.1W objectives and a Chameleon Vision II 690–1064 nm multiphoton laser (Coherent Europe), a Nikon TiE A1R laser-scanning confocal microscope equipped with a highdefinition resonant scanner, a piezo nano-drive (Mad City Labs Inc.) and operated via NIS-Elements software (version 5.30, Nikon Instruments Europe B.V.), and a Nikon Ti2 inverted microscope equipped with a Cicero spinning-disk confocal module (CrestOptics S.p.A.) and a Kinetix sCMOS camera (Teledyne Photometrics). .. Widefield tiled images were generated on a Zeiss Axio widefield NL5+ with 5x and 10x objectives.

    Inverted Microscopy:

    Article Title: Microcephaly-causative ASPM mutations disrupt mitotic spindle orientation and timely specification of human outer radial glia cells.
    Article Snippet: .. Confocal images were generated using a Zeiss LSM780 confocal system fitted on an Observer Z1 inverted microscope equipped driven by ZEN 2012 software (Zeiss) and equipped with 5x/0.16, 10x/0.3, 20x/0.8 and 40x/1.1W objectives and a Chameleon Vision II 690–1064 nm multiphoton laser (Coherent Europe), a Nikon TiE A1R laser-scanning confocal microscope equipped with a highdefinition resonant scanner, a piezo nano-drive (Mad City Labs Inc.) and operated via NIS-Elements software (version 5.30, Nikon Instruments Europe B.V.), and a Nikon Ti2 inverted microscope equipped with a Cicero spinning-disk confocal module (CrestOptics S.p.A.) and a Kinetix sCMOS camera (Teledyne Photometrics). .. Widefield tiled images were generated on a Zeiss Axio widefield NL5+ with 5x and 10x objectives.

    Software:

    Article Title: Microcephaly-causative ASPM mutations disrupt mitotic spindle orientation and timely specification of human outer radial glia cells.
    Article Snippet: .. Confocal images were generated using a Zeiss LSM780 confocal system fitted on an Observer Z1 inverted microscope equipped driven by ZEN 2012 software (Zeiss) and equipped with 5x/0.16, 10x/0.3, 20x/0.8 and 40x/1.1W objectives and a Chameleon Vision II 690–1064 nm multiphoton laser (Coherent Europe), a Nikon TiE A1R laser-scanning confocal microscope equipped with a highdefinition resonant scanner, a piezo nano-drive (Mad City Labs Inc.) and operated via NIS-Elements software (version 5.30, Nikon Instruments Europe B.V.), and a Nikon Ti2 inverted microscope equipped with a Cicero spinning-disk confocal module (CrestOptics S.p.A.) and a Kinetix sCMOS camera (Teledyne Photometrics). .. Widefield tiled images were generated on a Zeiss Axio widefield NL5+ with 5x and 10x objectives.

    Spinning Disk:

    Article Title: Microcephaly-causative ASPM mutations disrupt mitotic spindle orientation and timely specification of human outer radial glia cells.
    Article Snippet: .. Confocal images were generated using a Zeiss LSM780 confocal system fitted on an Observer Z1 inverted microscope equipped driven by ZEN 2012 software (Zeiss) and equipped with 5x/0.16, 10x/0.3, 20x/0.8 and 40x/1.1W objectives and a Chameleon Vision II 690–1064 nm multiphoton laser (Coherent Europe), a Nikon TiE A1R laser-scanning confocal microscope equipped with a highdefinition resonant scanner, a piezo nano-drive (Mad City Labs Inc.) and operated via NIS-Elements software (version 5.30, Nikon Instruments Europe B.V.), and a Nikon Ti2 inverted microscope equipped with a Cicero spinning-disk confocal module (CrestOptics S.p.A.) and a Kinetix sCMOS camera (Teledyne Photometrics). .. Widefield tiled images were generated on a Zeiss Axio widefield NL5+ with 5x and 10x objectives.

    Fluorescence:

    Article Title: Distinct prelimbic microcircuits control sensory and affective dimensions of neuropathic pain.
    Article Snippet: .. A two-photon microscope (Lavision Biotech, Trimscope) equipped with a Ti:Sa pulsed laser (Chameleon Ultra, Coherent) and a long-working-distance, high-numerical-aperture objective (Leica ×10, 0.4 NA) was used at 960 nm for fluorescence excitation and imaging. ..

    Article Title: Improving bi-exponential fitting of autofluorescence lifetime decay data through whole-cell binning
    Article Snippet: .. Fluorescence lifetime imaging of the LDH-NADH solution was performed using a custom-built inverted multiphoton fluorescence microscope (Marianas, 3i) equipped with a 40× water-immersion objective (NA 1.1), providing a field of view of ∼ 270 × 270 μ m . NADH was excited at 750 nm using a titanium:sapphire femtosecond laser (Chameleon, COHERENT), with excitation power maintained between 20 and 25 mW. .. Fluorescence lifetime data were acquired using TCSPC electronics (SPC-150N, Becker &Hickl).



    Similar Products

    90
    Vidrio Technologies matlab-based scanimage software

    Matlab Based Scanimage Software, supplied by Vidrio Technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/matlab-based+scanimage+software/scanimage+software/pmc10755854-365-52-54
    Average 90 stars, based on 1 article reviews
    matlab-based scanimage software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    Journal: Cell reports

    Article Title: All-optical recreation of naturalistic neural activity with a multifunctional transgenic reporter mouse

    doi: 10.1016/j.celrep.2023.112909

    Figure Lengend Snippet:

    Article Snippet: For 2-photon calcium imaging in vivo in awake animals ( , – , , and ), mice were head-fixed and allowed to run on a freely moving circular treadmill under a 20× magnification (1.0 NA) water-immersion objective (Olympus Corporation) and imaged with a Sutter MOM 2p resonance scanning microscope controlled with MATLAB-based ScanImage software (Vidrio Technologies) (see also microscope design, above, ).

    Techniques: Virus, Recombinant, Software, Activity Assay