Review




Structured Review

MBF Bioscience scanimage software v.2020.1.0
Scanimage Software V.2020.1.0, supplied by MBF Bioscience, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/matlab+scanimage+software/software++v++2020/pm40650286-179-4-7
Average 90 stars, based on 1 article reviews
scanimage software v.2020.1.0 - by Bioz Stars, 2026-09
90/100 stars

Images

Related Articles

other:

Article Title: Activity of Human-Specific Interlaminar Astrocytes in a Chimeric Mouse Model of Fragile X Syndrome.
Article Snippet: For imaging, we used ScanImage software v.2020.1.0 (MBF Biosciences, Williston, VT, USA) written in MATLAB v. R2024b (The MathWorks; Natick, MA, USA) [53].

Article Title: A combinatorial input landscape in the “higher-order relay” posterior thalamic nucleus
Article Snippet: The location and distribution of the BDA-labeled varicosities in Po were plotted using a motorized Nikon Eclipse 80i microscope with 40–60 brightfield objectives, Neurolucida controller, camera and software (v. 2020; MBF Bioscience).

Software:

Article Title: Differential effects of group III metabotropic glutamate receptors on spontaneous inhibitory synaptic currents in spine-innervating double bouquet and parvalbumin-expressing dendrite-targeting GABAergic interneurons in human neocortex.
Article Snippet: The India ink drawings were digitized using a digital camera (EOS 40D, Canon) and processed in Adobe Photoshop. .. Digital 3D reconstruction of some neurons (see Fig. 6a) was performed with Neurolucida software (v 2020 February 2 MBF Bioscience) and an Axioskop 2 mot plus (Zeiss) equipped with a Plan Apochromat 100x/1.4 Oil lens and Retiga 2000R (QImaging) digital camera, or with a v 2021 January 3 software and a Leica DMR microscope equipped with a HCX PL Fluotar 100x/1.30 Oil lens and Lumina HR (MBF Bioscience) digital camera. ..

Microscopy:

Article Title: Differential effects of group III metabotropic glutamate receptors on spontaneous inhibitory synaptic currents in spine-innervating double bouquet and parvalbumin-expressing dendrite-targeting GABAergic interneurons in human neocortex.
Article Snippet: The India ink drawings were digitized using a digital camera (EOS 40D, Canon) and processed in Adobe Photoshop. .. Digital 3D reconstruction of some neurons (see Fig. 6a) was performed with Neurolucida software (v 2020 February 2 MBF Bioscience) and an Axioskop 2 mot plus (Zeiss) equipped with a Plan Apochromat 100x/1.4 Oil lens and Retiga 2000R (QImaging) digital camera, or with a v 2021 January 3 software and a Leica DMR microscope equipped with a HCX PL Fluotar 100x/1.30 Oil lens and Lumina HR (MBF Bioscience) digital camera. ..



Similar Products

90
MathWorks Inc matlab scanimage software
Matlab Scanimage Software, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/matlab+scanimage+software/pmc11642993__pone__0309366__s001-42-4-4
Average 90 stars, based on 1 article reviews
matlab scanimage software - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Vidrio Technologies matlab-based scanimage software

Matlab Based Scanimage Software, supplied by Vidrio Technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/matlab+scanimage+software/scanimage+software/pmc10755854-365-52-54
Average 90 stars, based on 1 article reviews
matlab-based scanimage software - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
MathWorks Inc matlab software scanimage

Matlab Software Scanimage, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/matlab+scanimage+software/pmc04149184-219-3-1
Average 90 stars, based on 1 article reviews
matlab software scanimage - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Journal: Cell reports

Article Title: All-optical recreation of naturalistic neural activity with a multifunctional transgenic reporter mouse

doi: 10.1016/j.celrep.2023.112909

Figure Lengend Snippet:

Article Snippet: For 2-photon calcium imaging in vivo in awake animals ( , – , , and ), mice were head-fixed and allowed to run on a freely moving circular treadmill under a 20× magnification (1.0 NA) water-immersion objective (Olympus Corporation) and imaged with a Sutter MOM 2p resonance scanning microscope controlled with MATLAB-based ScanImage software (Vidrio Technologies) (see also microscope design, above, ).

Techniques: Virus, Recombinant, Software, Activity Assay