Review



simscape  (MathWorks Inc)


Bioz Verified Symbol MathWorks Inc is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 96

    Structured Review

    MathWorks Inc simscape
    Electrical configuration of whole-cell and microchamber voltage clamp. A, Whole-cell clamp speed is limited by τ ≈ Rs * Cm. Stray capacitance (amplifier, pipette holder, and pipette) is typically modeled in a position that does not interfere with voltage-clamp speed, but can influence measured high-frequency currents if not compensated. B, The microchamber partitions the cell partway within the orifice of the macropipette. Stray Cs1 is as with whole-cell mode. The frequency response of voltage clamp also depends on Rs and Cm, since stray Cs2, if it contributes at all, is dominated by Cm. The configuration in the figure is for a cell midway in the microchamber, membrane Cm equally divided. At high frequencies, the input capacitance will be the series combination of Cm/2 and Cm/2, giving a value of Cm/4. Thus, τ ≈ Rs * Cm/4 provides a faster clamp than whole cell, but the configuration suffers from lack of DC voltage-clamp control across the membranes. With partitioning of the cell more or less within the chamber, the series combination of the nonequal partitioned cell Cm will provide an input Cm less than the smaller of the two partitioned capacitances, regardless of its location inside or outside the microchamber. Thus, clamp τ for both inserted and extruded membranes will have the same U-shaped speed function, being slowest at the half-inserted condition, as depicted. C, Displayed are two current traces (ta and tb) generated by a Matlab <t>Simscape</t> microchamber model using a voltage protocol similar to our DC off-set AC voltage protocol (Fig. 10B, inset). The red trace (also marked with a downward red triangle) is at zero offset, and the blue trace (also marked with an upward blue triangle) is at an offset of −65 mV. Black lines are single exponential fits. Under voltage clamp, the time course of capacitive currents mirrors the time course of the voltage delivered to the cell membrane, as shown in D and E. See text for more details.
    Simscape, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 96/100, based on 1000 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/mat-lab+simulink+model/Simscape/pmc06001036-137-7-5
    Average 96 stars, based on 1000 article reviews
    simscape - by Bioz Stars, 2026-11
    96/100 stars

    Images

    1) Product Images from "The Frequency Response of Outer Hair Cell Voltage-Dependent Motility Is Limited by Kinetics of Prestin"

    Article Title: The Frequency Response of Outer Hair Cell Voltage-Dependent Motility Is Limited by Kinetics of Prestin

    Journal: The Journal of Neuroscience

    doi: 10.1523/JNEUROSCI.0425-18.2018

    Electrical configuration of whole-cell and microchamber voltage clamp. A, Whole-cell clamp speed is limited by τ ≈ Rs * Cm. Stray capacitance (amplifier, pipette holder, and pipette) is typically modeled in a position that does not interfere with voltage-clamp speed, but can influence measured high-frequency currents if not compensated. B, The microchamber partitions the cell partway within the orifice of the macropipette. Stray Cs1 is as with whole-cell mode. The frequency response of voltage clamp also depends on Rs and Cm, since stray Cs2, if it contributes at all, is dominated by Cm. The configuration in the figure is for a cell midway in the microchamber, membrane Cm equally divided. At high frequencies, the input capacitance will be the series combination of Cm/2 and Cm/2, giving a value of Cm/4. Thus, τ ≈ Rs * Cm/4 provides a faster clamp than whole cell, but the configuration suffers from lack of DC voltage-clamp control across the membranes. With partitioning of the cell more or less within the chamber, the series combination of the nonequal partitioned cell Cm will provide an input Cm less than the smaller of the two partitioned capacitances, regardless of its location inside or outside the microchamber. Thus, clamp τ for both inserted and extruded membranes will have the same U-shaped speed function, being slowest at the half-inserted condition, as depicted. C, Displayed are two current traces (ta and tb) generated by a Matlab Simscape microchamber model using a voltage protocol similar to our DC off-set AC voltage protocol (Fig. 10B, inset). The red trace (also marked with a downward red triangle) is at zero offset, and the blue trace (also marked with an upward blue triangle) is at an offset of −65 mV. Black lines are single exponential fits. Under voltage clamp, the time course of capacitive currents mirrors the time course of the voltage delivered to the cell membrane, as shown in D and E. See text for more details.
    Figure Legend Snippet: Electrical configuration of whole-cell and microchamber voltage clamp. A, Whole-cell clamp speed is limited by τ ≈ Rs * Cm. Stray capacitance (amplifier, pipette holder, and pipette) is typically modeled in a position that does not interfere with voltage-clamp speed, but can influence measured high-frequency currents if not compensated. B, The microchamber partitions the cell partway within the orifice of the macropipette. Stray Cs1 is as with whole-cell mode. The frequency response of voltage clamp also depends on Rs and Cm, since stray Cs2, if it contributes at all, is dominated by Cm. The configuration in the figure is for a cell midway in the microchamber, membrane Cm equally divided. At high frequencies, the input capacitance will be the series combination of Cm/2 and Cm/2, giving a value of Cm/4. Thus, τ ≈ Rs * Cm/4 provides a faster clamp than whole cell, but the configuration suffers from lack of DC voltage-clamp control across the membranes. With partitioning of the cell more or less within the chamber, the series combination of the nonequal partitioned cell Cm will provide an input Cm less than the smaller of the two partitioned capacitances, regardless of its location inside or outside the microchamber. Thus, clamp τ for both inserted and extruded membranes will have the same U-shaped speed function, being slowest at the half-inserted condition, as depicted. C, Displayed are two current traces (ta and tb) generated by a Matlab Simscape microchamber model using a voltage protocol similar to our DC off-set AC voltage protocol (Fig. 10B, inset). The red trace (also marked with a downward red triangle) is at zero offset, and the blue trace (also marked with an upward blue triangle) is at an offset of −65 mV. Black lines are single exponential fits. Under voltage clamp, the time course of capacitive currents mirrors the time course of the voltage delivered to the cell membrane, as shown in D and E. See text for more details.

    Techniques Used: Transferring, Generated

    Related Articles

    other:

    Article Title: A simulation-based dataset for anomaly detection in hydrogen blend transport networks
    Article Snippet: MATLAB_SIMSCAPE_Simulation/ , Original MATLAB Simscape files.

    Article Title: A simulation-based dataset for anomaly detection in hydrogen blend transport networks
    Article Snippet: The hydrogen transport network was modeled in MATLAB/Simscape (R2025a) using components from the Simscape Gas Fluids library.

    Article Title: A simulation-based dataset for anomaly detection in hydrogen blend transport networks
    Article Snippet: The model files can also be opened in earlier compatible MATLAB/Simscape versions (e.g., R2024a/b) and can be exported in a backward-compatible format.

    Article Title: Dual-Unit ECG Acquisition System Without Shared Ground: Design and Implementation.
    Article Snippet: The manufacturer-provided SPICE subcircuit description was automatically converted into a custom Simscape component using the subcircuit2ssc MATLAB function.

    Article Title: Enhanced terminal sliding mode control for gait exoskeleton device: experimental investigation and validation.
    Article Snippet: Furthermore, the models are validated in MATLAB/Simulink and Simscape, and extended with dynamic interaction assessments to suggest the device’s potential to support standard gait patterns, thereby addressing the relative underdevelopment of pediatric exoskeletons20.

    Article Title: Development and application of a hydrogen aircraft fuel system mass estimation framework
    Article Snippet: The framework is implemented in MATLAB Simscape, offering fast simulation cycles and modular component integration.

    Generated:

    Article Title: A simulation-based dataset for anomaly detection in hydrogen blend transport networks
    Article Snippet: .. Data collection , Data were generated using a MATLAB Simscape model simulating a hydrogen pipeline segment. The dataset includes 12 distributed virtual pressure sensors and 4 mass flow rate sensors, capturing both normal operating conditions and anomalous scenarios such as leaks, compressor failures, and delayed component responses. The simulation reproduces both transient and steady-state dynamics typical of industrial hydrogen transport networks.. ..

    Control:

    Article Title: A data-driven reinforcement learning framework for optimal balance control and stabilization of a rotary inverted pendulum
    Article Snippet: .. The practical significance of TD3 for RIP control was demonstrated by the agent, which was trained in MATLAB Simscape and verified using a hardware model. For the Rotary Inverted Pendulum, a two-degree-offreedom underactuated nonlinear system, an adaptive neural network-based robust control technique was presented in Zabihifar et al. (2020). ..



    Similar Products

    90
    MathWorks Inc mat lab simulink model
    Mat Lab Simulink Model, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/mat-lab+simulink+model/10__47392_slash_irjaem__2024__0137-153-12-14
    Average 90 stars, based on 1 article reviews
    mat lab simulink model - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc mat lab simulink ann system model
    Abbreviated dynamic model structure, in a parallel mode, of the overall NARX network for the input layer ( a ) and the output layer ( b ), according to the Mat <t>Lab</t> <t>Simulink</t> <t>ANN</t> system model construction process (details in text).
    Mat Lab Simulink Ann System Model, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/mat-lab+simulink+model/pmc08227104-90-28-30
    Average 90 stars, based on 1 article reviews
    mat lab simulink ann system model - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc mat-lab simulink model
    Abbreviated dynamic model structure, in a parallel mode, of the overall NARX network for the input layer ( a ) and the output layer ( b ), according to the Mat <t>Lab</t> <t>Simulink</t> <t>ANN</t> system model construction process (details in text).
    Mat Lab Simulink Model, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/mat-lab+simulink+model/10__1016_slash_j__ifacol__2019__12__581-217-31-32
    Average 90 stars, based on 1 article reviews
    mat-lab simulink model - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc discrete-time mat-765 lab/simulink models
    Abbreviated dynamic model structure, in a parallel mode, of the overall NARX network for the input layer ( a ) and the output layer ( b ), according to the Mat <t>Lab</t> <t>Simulink</t> <t>ANN</t> system model construction process (details in text).
    Discrete Time Mat 765 Lab/Simulink Models, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/mat-lab+simulink+model/10__1016_slash_j__cl__2017__09__001-519-8-10
    Average 90 stars, based on 1 article reviews
    discrete-time mat-765 lab/simulink models - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc cots mat lab/simulink modeling software package
    Abbreviated dynamic model structure, in a parallel mode, of the overall NARX network for the input layer ( a ) and the output layer ( b ), according to the Mat <t>Lab</t> <t>Simulink</t> <t>ANN</t> system model construction process (details in text).
    Cots Mat Lab/Simulink Modeling Software Package, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/mat-lab+simulink+model/us08260736-374-7-9
    Average 90 stars, based on 1 article reviews
    cots mat lab/simulink modeling software package - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    Abbreviated dynamic model structure, in a parallel mode, of the overall NARX network for the input layer ( a ) and the output layer ( b ), according to the Mat Lab Simulink ANN system model construction process (details in text).

    Journal: Insects

    Article Title: Soft Computing of a Medically Important Arthropod Vector with Autoregressive Recurrent and Focused Time Delay Artificial Neural Networks

    doi: 10.3390/insects12060503

    Figure Lengend Snippet: Abbreviated dynamic model structure, in a parallel mode, of the overall NARX network for the input layer ( a ) and the output layer ( b ), according to the Mat Lab Simulink ANN system model construction process (details in text).

    Article Snippet: An abbreviated dynamic model structure, in a parallel mode, of the overall NARX neural network for the input layer (a) and the output layer (b), according to the Mat Lab Simulink ANN system model construction process, is shown in .

    Techniques: