Review



macsquant tyto running buffer  (Miltenyi Biotec)


Bioz Verified Symbol Miltenyi Biotec is a verified supplier
Bioz Manufacturer Symbol Miltenyi Biotec manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 94

    Structured Review

    Miltenyi Biotec macsquant tyto running buffer
    Macsquant Tyto Running Buffer, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 94/100, based on 29 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/macsquant+running+buffer/MACSQuant+Tyto+Running+Buffer/pmc13083789-127-9-13
    Average 94 stars, based on 29 article reviews
    macsquant tyto running buffer - by Bioz Stars, 2026-11
    94/100 stars

    Images

    Related Articles

    Incubation:

    Article Title: CD133/CD49a discriminate between human pluripotent stem cell-derived pancreatic beta and alpha cells
    Article Snippet: .. The cells were then counted, centrifuged, and resuspended in MACSQuant Tyto Running Buffer (Miltenyi Biotec, #130-107-207) supplemented with CD133 antibody (1:10) and CD49a antibody (1:50) (100 μL buffer per 1 × 10 6 cells), and incubated for 15 min at room temperature. .. Subsequently, the cells were washed once with the Running Buffer and sorted on a Miltenyi MACSQuant Tyto sorter using gates to isolate single cells based on scatter characteristics.

    Article Title: CD133/CD49a discriminate between human pluripotent stem cell-derived pancreatic beta and alpha cells.
    Article Snippet: .. The cells were then counted, centrifuged, and resuspended in MACSQuant Tyto Running Buffer (Miltenyi Biotec, #130-107-207) supplemented with CD133 antibody (1:10) and CD49a antibody (1:50) (100 μL buffer per 1 × 10 6 cells), and incubated for 15 min at room temperature. .. Subsequently, the cells were washed once with the Running Buffer and sorted on a Miltenyi MACSQuant Tyto sorter using gates to isolate single cells based on scatter characteristics.

    Article Title: CD31 + Cell Enrichment Enhances Therapeutic Effects of Stromal Vascular Fraction in Experimental Primary Osteoarthritis: A Preclinical Study in the Dunkin Hartley Guinea Pig Model.
    Article Snippet: Adipose tissue was collected during general anesthesia via waterjet-assisted liposuction and subsequently processed using the automated Celution 800/CRS system (Cytori Therapeutics, San Diego, CA, US), which employs enzymatic digestion to isolate SVF [ 74 ]. .. To isolate CD31+ cells from SVF, SVF with a concentration of 1 × 108 cells/mL was incubated with a conjugated CD31/APC antibody (Blue Cell Therapeutics Ltd., Denmark) for 10 min. A PBS-based MACSQuant Tyto running buffer (130-107- 206, Miltenyi Biotec, Germany) was used for all washing steps and antibody incubations. .. The labeled SVF was then placed into a MACSQuant Tyto cartridge (130-104-791, Miltenyi Biotec, Germany), and CD31+ cells were sorted using a MACSQuant Tyto cell sorter (Miltenyi Biotec, Germany).

    Article Title: A molecular circuit regulates fate plasticity in emerging and adult AT2 cells
    Article Snippet: .. Cells are washed with sorting buffer (Miltenyi, 130-107-207) and subsequently incubated with 20 μL of each of the following secondary antibodies: (Anti-rabbit Alexa Fluor 647, anti-rat Alexa Fluor 405) for 30 min at 4 °C. .. EdU (Cayman Chemicals 20518) was administered via drinking water at 0.1 mg/mL for the indicated period of time.

    Staining:

    Article Title: A comparative study for the isolation of rabbit phenotypically defined candidate HSPCs based on CD45 or CD34 marker expression
    Article Snippet: Briefly, cells were diluted in 1 ml of sterile MACS Separation Buffer and incubated in the dark and under sterile conditions with mAb 575/36/8 or 58/47/34 (at a final concentration of at least 10 μg/ml) and with 10 μl of LIVE/DEAD Fixable Green Dead Cell Stain Kit (Live/Dead Green; Thermo Fisher Scientific, Waltham, MA, USA) for 15 min. on ice with gentle mixing on vortex mixer each 5 min. After washing, cells were co-labeled with APC conjugated rat antimouse IgG1 antibody (eBioscience) under the same conditions as for rabbit CD34 mAb as well as according to the producer’s manual. .. Afterwards stained cells were diluted in 10 ml of MACSQuant Tyto Running Buffer (Miltenyi Biotec) and gently filtered through 20 μm filter to get single cell population for further sorting procedure. .. The filtered cells were loaded into the MACSQuant Tyto Cartridge and immediately sorted using MACSQuant Tyto Cell Sorter (both from Miltenyi Biotec) according to producer’s manual by gating live (Live/Dead Green-) and CD34+ rabbit bone marrow cells.

    Article Title: IgG4 + plasma cell enrichment and λ-chain-biased BCR remodeling drive low-grade autoimmunity in chronic obstructive pulmonary disease
    Article Snippet: For live B-cell sorting, PBMCs were stained with anti-CD45-FITC (BioLegend, clone HI30), anti-CD19-PerCP-Cy5.5 (BioLegend, clone HIB19) and fixable viability stain 506 (FVS506; BD Horizon) for 30 min on ice in the dark. .. Following staining, cells were washed twice and resuspended in MACSQuant Tyto running buffer (Miltenyi Biotec) at a concentration of 2–4 × 106 cells/mL. .. Cell sorting was performed using a MACSQuant Tyto cell sorter (Miltenyi Biotec) equipped with 405 nm, 488 nm, and 561 nm lasers and a closed cartridge-based system.

    Single Cell:

    Article Title: A comparative study for the isolation of rabbit phenotypically defined candidate HSPCs based on CD45 or CD34 marker expression
    Article Snippet: Briefly, cells were diluted in 1 ml of sterile MACS Separation Buffer and incubated in the dark and under sterile conditions with mAb 575/36/8 or 58/47/34 (at a final concentration of at least 10 μg/ml) and with 10 μl of LIVE/DEAD Fixable Green Dead Cell Stain Kit (Live/Dead Green; Thermo Fisher Scientific, Waltham, MA, USA) for 15 min. on ice with gentle mixing on vortex mixer each 5 min. After washing, cells were co-labeled with APC conjugated rat antimouse IgG1 antibody (eBioscience) under the same conditions as for rabbit CD34 mAb as well as according to the producer’s manual. .. Afterwards stained cells were diluted in 10 ml of MACSQuant Tyto Running Buffer (Miltenyi Biotec) and gently filtered through 20 μm filter to get single cell population for further sorting procedure. .. The filtered cells were loaded into the MACSQuant Tyto Cartridge and immediately sorted using MACSQuant Tyto Cell Sorter (both from Miltenyi Biotec) according to producer’s manual by gating live (Live/Dead Green-) and CD34+ rabbit bone marrow cells.

    Concentration Assay:

    Article Title: CD31 + Cell Enrichment Enhances Therapeutic Effects of Stromal Vascular Fraction in Experimental Primary Osteoarthritis: A Preclinical Study in the Dunkin Hartley Guinea Pig Model.
    Article Snippet: Adipose tissue was collected during general anesthesia via waterjet-assisted liposuction and subsequently processed using the automated Celution 800/CRS system (Cytori Therapeutics, San Diego, CA, US), which employs enzymatic digestion to isolate SVF [ 74 ]. .. To isolate CD31+ cells from SVF, SVF with a concentration of 1 × 108 cells/mL was incubated with a conjugated CD31/APC antibody (Blue Cell Therapeutics Ltd., Denmark) for 10 min. A PBS-based MACSQuant Tyto running buffer (130-107- 206, Miltenyi Biotec, Germany) was used for all washing steps and antibody incubations. .. The labeled SVF was then placed into a MACSQuant Tyto cartridge (130-104-791, Miltenyi Biotec, Germany), and CD31+ cells were sorted using a MACSQuant Tyto cell sorter (Miltenyi Biotec, Germany).

    Article Title: IgG4 + plasma cell enrichment and λ-chain-biased BCR remodeling drive low-grade autoimmunity in chronic obstructive pulmonary disease
    Article Snippet: For live B-cell sorting, PBMCs were stained with anti-CD45-FITC (BioLegend, clone HI30), anti-CD19-PerCP-Cy5.5 (BioLegend, clone HIB19) and fixable viability stain 506 (FVS506; BD Horizon) for 30 min on ice in the dark. .. Following staining, cells were washed twice and resuspended in MACSQuant Tyto running buffer (Miltenyi Biotec) at a concentration of 2–4 × 106 cells/mL. .. Cell sorting was performed using a MACSQuant Tyto cell sorter (Miltenyi Biotec) equipped with 405 nm, 488 nm, and 561 nm lasers and a closed cartridge-based system.

    Article Title: Automated GMP-compatible production of universal CAR Tregs for organ-targeted tolerance induction.
    Article Snippet: The enriched cells were further labeled using MACS GMP clinical-grade antibodies: CD4-Vioblue (Clone M-T466, Miltenyi Biotec) and CD127-FITC (Clone MB15-18C9, Miltenyi Biotec) at 1:31 dilution and CD8APC (Clone BW135/80, Miltenyi Biotec) at either 1:31 or 1:21 dilution for 30 minutes at 4 °C, followed by a single wash with working buffer (300xg, 15 minutes). .. For sorting, the cells were resuspended in 10 mL of MACSQuant Tyto Running Buffer (Miltenyi Biotec) achieving an average concentration of 7.4 × 106 cells/mL (range: 6.9 × 106 to 7.8 × 106). .. The cells were filtered through a 20 μm cellstrainer and loaded into the MACSQuant Tyto high speed (HS) cartridges (Miltenyi Biotec) and sorted on the MACSQuant Tyto Cell Sorter (Miltenyi Biotec).

    other:

    Article Title: Automated GMP-compatible production of universal CAR Tregs for organ-targeted tolerance induction
    Article Snippet: The enriched cells were further labeled using MACS GMP clinical-grade antibodies: CD4-Vioblue (Clone M-T466, Miltenyi Biotec) and CD127-FITC (Clone MB15-18C9, Miltenyi Biotec) at 1:31 dilution and CD8-APC (Clone BW135/80, Miltenyi Biotec) at either 1:31 or 1:21 dilution for 30 minutes at 4 °C, followed by a single wash with working buffer (300xg, 15 minutes).



    Similar Products

    95
    Miltenyi Biotec macsquant running buffer
    Macsquant Running Buffer, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/macsquant+running+buffer/MACSQuant+Running+Buffer/pm42508561-81-14-17
    Average 95 stars, based on 1 article reviews
    macsquant running buffer - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    94
    Miltenyi Biotec macsquant tyto running buffer
    Macsquant Tyto Running Buffer, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/macsquant+running+buffer/MACSQuant+Tyto+Running+Buffer/10__1038_slash_s41598___026___74633___x-142-9-13
    Average 94 stars, based on 1 article reviews
    macsquant tyto running buffer - by Bioz Stars, 2026-11
    94/100 stars
      Buy from Supplier

    94
    Miltenyi Biotec pbs based macsquant tyto running buffer
    Pbs Based Macsquant Tyto Running Buffer, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/macsquant+running+buffer/MACSQuant+Tyto+Running+Buffer/pm42435424-303-31-38
    Average 94 stars, based on 1 article reviews
    pbs based macsquant tyto running buffer - by Bioz Stars, 2026-11
    94/100 stars
      Buy from Supplier

    95
    Miltenyi Biotec cells
    Cells, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/macsquant+running+buffer/MACSQuant+Running+Buffer/pm42380677-328-2-13
    Average 95 stars, based on 1 article reviews
    cells - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    95
    Miltenyi Biotec macsquant running buffer for cytometry
    Production and titration of LV using replicon cell pools (RCPs) or conventional three-plasmid transfection of HEK293FT cells. ( a ) LV/CAR-GFP production in 10 cm dishes. Supernatant was harvested at 48 h post-transfection, replaced with fresh medium, and collected again at 96 h. Bar graph shows functional titers (TU/mL) from three independent experiments (mean ± SD). ( b ) Representative images of HEK293FT cells transduced with LV/CAR-GFP during titration experiment. Cells in the first well of a 6-well plate (1:10 dilution of culture supernatant) were photographed 48 h post-transduction. Left: phase contrast; right: GFP fluorescence. Magnification: 10× objective; scale bar: 100 µm. ( c ) Schematic workflow of large-scale LV/CAR production in 5-layer stacks using RCP cells, or conventional HEK293FT cells. ( d ) Flow <t>cytometry</t> histograms for titration of LV/CAR vector. HEK293FT cells were transduced to express CAR and stained with PE-conjugated anti-CAR antibodies. Numbers indicate the percentage of CAR-positive cells.
    Macsquant Running Buffer For Cytometry, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/macsquant+running+buffer/MACSQuant+Running+Buffer/pmc13255789-152-14-20
    Average 95 stars, based on 1 article reviews
    macsquant running buffer for cytometry - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    Image Search Results


    Production and titration of LV using replicon cell pools (RCPs) or conventional three-plasmid transfection of HEK293FT cells. ( a ) LV/CAR-GFP production in 10 cm dishes. Supernatant was harvested at 48 h post-transfection, replaced with fresh medium, and collected again at 96 h. Bar graph shows functional titers (TU/mL) from three independent experiments (mean ± SD). ( b ) Representative images of HEK293FT cells transduced with LV/CAR-GFP during titration experiment. Cells in the first well of a 6-well plate (1:10 dilution of culture supernatant) were photographed 48 h post-transduction. Left: phase contrast; right: GFP fluorescence. Magnification: 10× objective; scale bar: 100 µm. ( c ) Schematic workflow of large-scale LV/CAR production in 5-layer stacks using RCP cells, or conventional HEK293FT cells. ( d ) Flow cytometry histograms for titration of LV/CAR vector. HEK293FT cells were transduced to express CAR and stained with PE-conjugated anti-CAR antibodies. Numbers indicate the percentage of CAR-positive cells.

    Journal: Biology

    Article Title: Development of Replicon Cell Pools Bearing a Flavivirus RNA Replicon as a Source of HIV-1 Gag-Pol for Lentiviral Vector Production

    doi: 10.3390/biology15110848

    Figure Lengend Snippet: Production and titration of LV using replicon cell pools (RCPs) or conventional three-plasmid transfection of HEK293FT cells. ( a ) LV/CAR-GFP production in 10 cm dishes. Supernatant was harvested at 48 h post-transfection, replaced with fresh medium, and collected again at 96 h. Bar graph shows functional titers (TU/mL) from three independent experiments (mean ± SD). ( b ) Representative images of HEK293FT cells transduced with LV/CAR-GFP during titration experiment. Cells in the first well of a 6-well plate (1:10 dilution of culture supernatant) were photographed 48 h post-transduction. Left: phase contrast; right: GFP fluorescence. Magnification: 10× objective; scale bar: 100 µm. ( c ) Schematic workflow of large-scale LV/CAR production in 5-layer stacks using RCP cells, or conventional HEK293FT cells. ( d ) Flow cytometry histograms for titration of LV/CAR vector. HEK293FT cells were transduced to express CAR and stained with PE-conjugated anti-CAR antibodies. Numbers indicate the percentage of CAR-positive cells.

    Article Snippet: Cells were detached with trypsin-EDTA, washed with PBS, and resuspended in 1 mL of MACSQuant Running Buffer for cytometry (RB, Miltenyi Biotec Cat. 130-092-747).

    Techniques: Titration, Plasmid Preparation, Transfection, Functional Assay, Transduction, Fluorescence, Flow Cytometry, Staining

    Characterization of a CAR-T cell product generated using LV/CAR vector produced from RCP cells. ( a ) Representative flow cytometry plots showing the gating strategy used for counting CAR + cells (debris exclusion, CD45 + leukocytes, viable cells, CD3 + T cells, and CAR + subset within CD3 + cells). ( b ) Summary of cell product composition after T-cell selection and transduction, including cell subsets, markers, event counts, and relative frequencies.

    Journal: Biology

    Article Title: Development of Replicon Cell Pools Bearing a Flavivirus RNA Replicon as a Source of HIV-1 Gag-Pol for Lentiviral Vector Production

    doi: 10.3390/biology15110848

    Figure Lengend Snippet: Characterization of a CAR-T cell product generated using LV/CAR vector produced from RCP cells. ( a ) Representative flow cytometry plots showing the gating strategy used for counting CAR + cells (debris exclusion, CD45 + leukocytes, viable cells, CD3 + T cells, and CAR + subset within CD3 + cells). ( b ) Summary of cell product composition after T-cell selection and transduction, including cell subsets, markers, event counts, and relative frequencies.

    Article Snippet: Cells were detached with trypsin-EDTA, washed with PBS, and resuspended in 1 mL of MACSQuant Running Buffer for cytometry (RB, Miltenyi Biotec Cat. 130-092-747).

    Techniques: Generated, Plasmid Preparation, Produced, Flow Cytometry, Selection, Transduction