Review




Structured Review

KARL STORZ standard tungsten wire loop
Standard Tungsten Wire Loop, supplied by KARL STORZ, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/loop+wire/standard+tungsten+wire+loop/pmc06850481-89-25-29
Average 90 stars, based on 1 article reviews
standard tungsten wire loop - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

other:

Article Title: Four-year outcome of a prospective randomised trial comparing bipolar plasmakinetic and monopolar transurethral resection of the prostate.
Article Snippet: Riccardo Autorino *, Rocco Damiano , Giuseppe Di Lorenzo , Giuseppe Quarto , Sisto Perdonà , Massimo D’Armiento , Marco De Sio a Clinica Urologica, Seconda Università degli Studi, Napoli, Italy Cattedra di Urologia, Università Magna Graecia, Catanzaro, Italy Dipartimento di Oncologia Molecolare e Clinica, Università Federico II, Napoli, Italy UO Urologia, INT Fondazione G. Pascale, Napoli, Italy e u r o p e a n u r o l o g y 5 5 ( 2 0 0 9 ) 9 2 2 – 9 3 1

Article Title: A randomized trial comparing thulium laser resection to standard transurethral resection of the prostate for symptomatic benign prostatic hyperplasia: four-year follow-up results.
Article Snippet: Objective To report the results of a randomized prospective trial with a 4-year follow-up, comparing the thulium laser resection of the prostate-tangerine technique (TmLRP-TT) with transurethral resection of prostate (TURP) for treatment of symptomatic benign prostatic hyperplasia (BPH).. Methods BPH patients (96) were randomized for surgical treatment with TmLRP-TT (47) or TURP (49).. All patients were assessed pre-operatively and followed at 12, 24, 36, and 48 months post-operatively.

Article Title: Prostatic artery embolization versus conventional TUR-P in the treatment of benign prostatic hyperplasia: protocol for a prospective randomized non-inferiority trial
Article Snippet: A standard tungsten wire loop (Karl Storz Endoskope; Anklin AG, Binnigen, Switzerland) and electrolyte-free mannitol-sorbitol solution (Purisole, Fresenius Kabi AG, Bad Homburg, Germany) will be used for TURP.

Article Title: In‐hospital cost analysis of prostatic artery embolization compared with transurethral resection of the prostate: post hoc analysis of a randomized controlled trial
Article Snippet: Monopolar TURP was performed under spinal or general anaesthesia by four board‐certified study physicians using a 24‐F resectoscope (Karl Storz Endoskope, Binningen, Switzerland) with a standard tungsten wire loop (Karl Storz Endoskope) and electrolyte‐free mannitol‐sorbitol solution (Purisole [Fresenius Kabi AG, Bad Homburg, Germany]).

Article Title: Holmium laser enucleation versus transurethral resection of the prostate: 3-year follow-up results of a randomized clinical trial.
Article Snippet: Objectives: To report 3-yr follow-up results of a randomised clinical trial comparing holmium laser enucleation of the prostate (HoLEP) with transurethral resection of the prostate (TURP).. Methods: A total of 200 patients with urodynamic obstruction and a prostate volume of less than 100 cc were prospectively randomised and assigned to HoLEP or TURP.. All patients were assessed preoperatively and followed at 1, 6, 12, 18, 24, and 36 mo postoperatively.

Coagulation:

Article Title: Recurrent Dystrophic Calcification of the Prostatic Resection Cavity After Transurethral Resection of the Prostate: Clinical Presentation and Endoscopic Management
Article Snippet: .. Monopolar TURP was performed within a clinical trial using a 24F Storz resectoscope with a cutting power of 180 W and a coagulation power of 60 W. A standard tungsten wire loop (Karl Storz Endoskopie; Anklin AG, Binningen, Switzerland) and electrolyte-free mannitol-sorbitol solution (Purisole, Fresenius Kabi AG, Bad Homburg, Germany) were used. ..

Article Title: Bipolar versus monopolar transurethral resection of the prostate: results of a comparative, prospective bicenter study--perioperative outcome and long-term efficacy.
Article Snippet: Objectives: To compare bipolar and monopolar transurethral resection of the prostate (TURP) in a comparative prospective study at two urology centers.. Methods: Of 212 patients with symptomatic benign prostatic hyperplasia entered prospectively into the study, 111 underwent bipolar and 101 monopolar TURP.. Patients were treated in two consecutive series with each surgical method at both centers.



Similar Products

86
Arthrex Inc nitinol wire loop
Nitinol Wire Loop, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/loop+wire/nitinol+wire/pm41324432-58-8-11
Average 86 stars, based on 1 article reviews
nitinol wire loop - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Arthrex Inc wire loop tool
Wire Loop Tool, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/loop+wire/loop+tool+wire/pm41067624-68-14-17
Average 86 stars, based on 1 article reviews
wire loop tool - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Instech Laboratories loop wire
Loop Wire, supplied by Instech Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/loop+wire/loop+wire/pmc12448133-258-12-17
Average 86 stars, based on 1 article reviews
loop wire - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

90
Arthrex Inc wire loop arthrex
Wire Loop Arthrex, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/loop+wire/fiberloops+arthrex/pmc12277742-66-1-3
Average 90 stars, based on 1 article reviews
wire loop arthrex - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

86
Agilis Biotherapeutics wire loop
Wire Loop, supplied by Agilis Biotherapeutics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/loop+wire/exchange+length/pmc12441537-73-1-12
Average 86 stars, based on 1 article reviews
wire loop - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Merck & Co conventional wire loop
Conventional Wire Loop, supplied by Merck & Co, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/loop+wire/conventional+loop+wire/pmc12486511-77-27-30
Average 86 stars, based on 1 article reviews
conventional wire loop - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

90
Arthrex Inc suturelasso sd wire loop
Intraoperative photographs detailing minimally invasive arthroscopic treatment of isolated Rockwood type III acute acromioclavicular dislocation in left shoulder of male patient via Dog Bone Button. The arthroscopic steps are as follows: (A) Through the anterolateral portal, the inferior surface of the coracoid is visualized. By use of the Serfas vaporizer instrument introduced through the anteroinferior portal, the inferior surface is skeletonized, exposing it as much as possible. (B) Visualization of inferior surface of coracoid from anteroinferior portal. (C) Visualization of inferior surface of coracoid from anteroinferior portal, followed by skeletonization of inferior surface using Serfas vaporizer instrument through anterolateral portal. (D) Visualization of inferior surface of coracoid from anteroinferior portal, with skeletonization of inferior surface using 4.0-mm powered shaver (Stryker) through anterolateral portal. (E) Palpation of medial margin of coracoid with probe (Stryker) introduced through anterolateral portal, with visualization from anteroinferior portal. (F) Palpation of medial margin of coracoid using the extremity of acromion Arthrex compass at 90° angle through anterolateral portal, with visualization from anteroinferior portal. (G) Visualization of drill insertion from anteroinferior portal, performed with Arthrex compass and drill, both introduced through anterolateral portal. (H) Passage of <t>SutureLasso</t> SD Wire Loop through Arthrex cannulated drill, visualized from anterolateral portal. (I) Retrieval of SutureLasso SD Wire Loop from Arthrex cannulated drill, correctly positioned at inferior surface of coracoid base. This is visualized from the anterolateral portal, and retrieval is performed with an arthroscopic grasper (Stryker) through the anteroinferior portal. (J) After loading the 2 FiberTape sutures of the Dog Bone Button onto the SutureLasso, the SutureLasso is retrieved, thereby pulling the 2 FiberTape sutures of the Dog Bone Button through the coracoid. This step is visualized from the anterolateral portal, with the FiberTape sutures being inserted through the anteroinferior portal. (K) Visualization of Dog Bone Button in vertical position on inferior surface of coracoid from anterolateral portal. (L) Visualization of Dog Bone Button properly positioned at inferior surface of coracoid base from anterolateral portal.
Suturelasso Sd Wire Loop, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/loop+wire/suturelasso+wire+loop/pmc12255453-58-9-13
Average 90 stars, based on 1 article reviews
suturelasso sd wire loop - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Arthrex Inc nitinol wire shuttle loop
<t>Shuttle</t> <t>loop</t> preparation and graft passage for reduction. (A) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. A <t>nitinol</t> <t>wire</t> shuttle loop with a passing hook (Arthrex) is cautiously placed close to the medial cortex of the coracoid base to avoid nerve injury. (B) Outside view of left shoulder with patient in beach-chair position. A FiberTape (white arrow) along with the long head of the biceps tendon (LHBT) graft (black arrow), in a venae comitantes fashion, is dragged into the subacromial space. The green arrows indicate the shuttle loop, and the yellow arrows indicate the epidural needles. (C) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape with 1 tail suture (“string”) of LHBT under base of coracoid. (D) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape along with LHBT around base of coracoid using shuttle loop. (E) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The grafts loop around the coracoid base. (F) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The 2 ends of the grafts are crossed and form an X shape within the coracoclavicular interval. The stars indicate the coracoid base.
Nitinol Wire Shuttle Loop, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/loop+wire/nitinol+wire/pmc12255420-56-4-25
Average 90 stars, based on 1 article reviews
nitinol wire shuttle loop - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Intraoperative photographs detailing minimally invasive arthroscopic treatment of isolated Rockwood type III acute acromioclavicular dislocation in left shoulder of male patient via Dog Bone Button. The arthroscopic steps are as follows: (A) Through the anterolateral portal, the inferior surface of the coracoid is visualized. By use of the Serfas vaporizer instrument introduced through the anteroinferior portal, the inferior surface is skeletonized, exposing it as much as possible. (B) Visualization of inferior surface of coracoid from anteroinferior portal. (C) Visualization of inferior surface of coracoid from anteroinferior portal, followed by skeletonization of inferior surface using Serfas vaporizer instrument through anterolateral portal. (D) Visualization of inferior surface of coracoid from anteroinferior portal, with skeletonization of inferior surface using 4.0-mm powered shaver (Stryker) through anterolateral portal. (E) Palpation of medial margin of coracoid with probe (Stryker) introduced through anterolateral portal, with visualization from anteroinferior portal. (F) Palpation of medial margin of coracoid using the extremity of acromion Arthrex compass at 90° angle through anterolateral portal, with visualization from anteroinferior portal. (G) Visualization of drill insertion from anteroinferior portal, performed with Arthrex compass and drill, both introduced through anterolateral portal. (H) Passage of SutureLasso SD Wire Loop through Arthrex cannulated drill, visualized from anterolateral portal. (I) Retrieval of SutureLasso SD Wire Loop from Arthrex cannulated drill, correctly positioned at inferior surface of coracoid base. This is visualized from the anterolateral portal, and retrieval is performed with an arthroscopic grasper (Stryker) through the anteroinferior portal. (J) After loading the 2 FiberTape sutures of the Dog Bone Button onto the SutureLasso, the SutureLasso is retrieved, thereby pulling the 2 FiberTape sutures of the Dog Bone Button through the coracoid. This step is visualized from the anterolateral portal, with the FiberTape sutures being inserted through the anteroinferior portal. (K) Visualization of Dog Bone Button in vertical position on inferior surface of coracoid from anterolateral portal. (L) Visualization of Dog Bone Button properly positioned at inferior surface of coracoid base from anterolateral portal.

Journal: Arthroscopy Techniques

Article Title: Two Scope Portals in Simple Acromioclavicular Joint Type III Injury

doi: 10.1016/j.eats.2025.103536

Figure Lengend Snippet: Intraoperative photographs detailing minimally invasive arthroscopic treatment of isolated Rockwood type III acute acromioclavicular dislocation in left shoulder of male patient via Dog Bone Button. The arthroscopic steps are as follows: (A) Through the anterolateral portal, the inferior surface of the coracoid is visualized. By use of the Serfas vaporizer instrument introduced through the anteroinferior portal, the inferior surface is skeletonized, exposing it as much as possible. (B) Visualization of inferior surface of coracoid from anteroinferior portal. (C) Visualization of inferior surface of coracoid from anteroinferior portal, followed by skeletonization of inferior surface using Serfas vaporizer instrument through anterolateral portal. (D) Visualization of inferior surface of coracoid from anteroinferior portal, with skeletonization of inferior surface using 4.0-mm powered shaver (Stryker) through anterolateral portal. (E) Palpation of medial margin of coracoid with probe (Stryker) introduced through anterolateral portal, with visualization from anteroinferior portal. (F) Palpation of medial margin of coracoid using the extremity of acromion Arthrex compass at 90° angle through anterolateral portal, with visualization from anteroinferior portal. (G) Visualization of drill insertion from anteroinferior portal, performed with Arthrex compass and drill, both introduced through anterolateral portal. (H) Passage of SutureLasso SD Wire Loop through Arthrex cannulated drill, visualized from anterolateral portal. (I) Retrieval of SutureLasso SD Wire Loop from Arthrex cannulated drill, correctly positioned at inferior surface of coracoid base. This is visualized from the anterolateral portal, and retrieval is performed with an arthroscopic grasper (Stryker) through the anteroinferior portal. (J) After loading the 2 FiberTape sutures of the Dog Bone Button onto the SutureLasso, the SutureLasso is retrieved, thereby pulling the 2 FiberTape sutures of the Dog Bone Button through the coracoid. This step is visualized from the anterolateral portal, with the FiberTape sutures being inserted through the anteroinferior portal. (K) Visualization of Dog Bone Button in vertical position on inferior surface of coracoid from anterolateral portal. (L) Visualization of Dog Bone Button properly positioned at inferior surface of coracoid base from anterolateral portal.

Article Snippet: The trocar is removed from the drill, and a SutureLasso SD Wire Loop (Arthrex) is passed through the drill cannulation loop and then retrieved through the anteroinferior portal, viewing through the anterolateral portal.

Techniques: Isolation

Shuttle loop preparation and graft passage for reduction. (A) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. A nitinol wire shuttle loop with a passing hook (Arthrex) is cautiously placed close to the medial cortex of the coracoid base to avoid nerve injury. (B) Outside view of left shoulder with patient in beach-chair position. A FiberTape (white arrow) along with the long head of the biceps tendon (LHBT) graft (black arrow), in a venae comitantes fashion, is dragged into the subacromial space. The green arrows indicate the shuttle loop, and the yellow arrows indicate the epidural needles. (C) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape with 1 tail suture (“string”) of LHBT under base of coracoid. (D) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape along with LHBT around base of coracoid using shuttle loop. (E) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The grafts loop around the coracoid base. (F) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The 2 ends of the grafts are crossed and form an X shape within the coracoclavicular interval. The stars indicate the coracoid base.

Journal: Arthroscopy Techniques

Article Title: Autologous Long Head of Biceps Tendon With High-Strength Suture for Reconstruction of Coracoclavicular Ligament

doi: 10.1016/j.eats.2025.103465

Figure Lengend Snippet: Shuttle loop preparation and graft passage for reduction. (A) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. A nitinol wire shuttle loop with a passing hook (Arthrex) is cautiously placed close to the medial cortex of the coracoid base to avoid nerve injury. (B) Outside view of left shoulder with patient in beach-chair position. A FiberTape (white arrow) along with the long head of the biceps tendon (LHBT) graft (black arrow), in a venae comitantes fashion, is dragged into the subacromial space. The green arrows indicate the shuttle loop, and the yellow arrows indicate the epidural needles. (C) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape with 1 tail suture (“string”) of LHBT under base of coracoid. (D) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. Passage of FiberTape along with LHBT around base of coracoid using shuttle loop. (E) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The grafts loop around the coracoid base. (F) Subacromial interval arthroscopic view of left shoulder with 30° arthroscope in lateral portal. The 2 ends of the grafts are crossed and form an X shape within the coracoclavicular interval. The stars indicate the coracoid base.

Article Snippet: Under arthroscopic visualization, a nitinol wire shuttle loop is passed around the base of the coracoid from medial to lateral with a passing hook (AR-7806; Arthrex), which is cautiously placed close to the medial cortex of the coracoid base to avoid nerve injury ( A).

Techniques: