Review



computer vision toolboxtm 9 2  (MathWorks Inc)


Bioz Verified Symbol MathWorks Inc is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 96

    Structured Review

    MathWorks Inc computer vision toolboxtm 9 2
    Computer Vision Toolboxtm 9 2, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 96/100, based on 427 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/kanade-+lucas-tomasi+(klt)+feature-tracking+algorithm/Computer+Vision+Toolbox/pmc07664231-59-10-15
    Average 96 stars, based on 427 article reviews
    computer vision toolboxtm 9 2 - by Bioz Stars, 2026-11
    96/100 stars

    Images

    Related Articles

    other:

    Article Title: Longitudinal Multi-Batch Characterisation of Beer Wort Fermentation Foam Using Image-Based Semantic Segmentation.
    Article Snippet: Development and within-batch evaluation of the segmentation component (a) Segmentation model and training A convolutional encoder–decoder network was implemented in MATLAB R2024a using the Deep Learning Toolbox and Computer Vision Toolbox.

    Article Title: Optical Smart-Wheel Sensing of Tire Deformation for Tire State and Load Estimation.
    Article Snippet: The Camera Calibrator app in MATLAB R2025b (Computer Vision Toolbox, version 25.2) was used with checkerboard images acquired at different positions and orientations.

    Article Title: A thermopile array and stereo vision fusion system for small-tube temperature sensing.
    Article Snippet: For the calibration of the stereo vision system, we used the wellestablished Zhang’s chessboard calibration method, implemented using the MATLAB stereo camera calibrator toolbox.

    Article Title: Physics-Based Synthetic Training for Automatic Target Detection in Radar Imaging
    Article Snippet: Training and inference are implemented in MATLAB R2025b using the Deep Learning Toolbox and Computer Vision Toolbox.

    Article Title: Mechanical Fidelity of Fixed-Cell Traction Force Microscopy
    Article Snippet: Fluorescent bead feature points were detected using the MATLAB function detectMinEigenFeatures (Computer Vision Toolbox), which implements the Shi– Tomasi minimum-eigenvalue corner detector.

    Article Title: Novel image analysis method for estimating muscle strain from ultrasound B-mode images.
    Article Snippet: All analyses were performed using MATLAB 2024a and the Computer Vision Toolbox (MathWorks Inc., Natick, MA, USA).

    Article Title: Poisson's Ratio‐Driven Control of Myogenic Differentiation and Maturation in Auxetic Metamaterials under Dynamic Mechanical Stimulation
    Article Snippet: The Poisson’s ratio was calculated using a custom MATLAB script (Computer Vision Toolbox).

    Tissue:

    Article Title: Quantifying the influence of contraction history on ex vivo bladder mechanics using optogenetics.
    Article Snippet: Initial images and video of the deformation were recorded with a camera (Lumenera Infinity 3) mounted to a dissecting microscope (Leica M80). .. To calculate tissue deformation, pin locations were tracked with the resulting video using a combination of Kanade-Lucas-Tomasi and aggregate channel features object detectors from the MATLAB Image Processing and Computer Vision toolbox. ..



    Similar Products

    90
    MathWorks Inc kanade- lucas-tomasi (klt) feature-tracking algorithm
    Kanade Lucas Tomasi (Klt) Feature Tracking Algorithm, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/kanade-+lucas-tomasi+(klt)+feature-tracking+algorithm/pm32696231-121-17-32
    Average 90 stars, based on 1 article reviews
    kanade- lucas-tomasi (klt) feature-tracking algorithm - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc kanade-lucas-tomasi (klt) feature tracking algorithm
    Kanade Lucas Tomasi (Klt) Feature Tracking Algorithm, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/kanade-+lucas-tomasi+(klt)+feature-tracking+algorithm/pmc06611451-89-1-15
    Average 90 stars, based on 1 article reviews
    kanade-lucas-tomasi (klt) feature tracking algorithm - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc kanade-lucas-tomasi features tracking algorithm klt
    (a) Description of the method used to quantify to pulsatile Rho1 activity without cell segmentation (see Methods for more details and Supplementary Movie 16). Basically, isolated clusters of AniRBD::eGFP signal are detected using a DBSCAN algorithm. These clusters are then converted into surface ROIs using convex hulls and overlapping ROIs tracked over time to follow individual pulses. Filters such as min./max. area or min./max. duration are applied to <t>reduce</t> <t>tracking</t> mistakes. Finally, the AniRBD::eGFP pulse amplitude measurements are performed considering the maximum of total fluorescence intensity for each track. (b) MyoII pulses are automatically detected in time following the derivatives of high-pass filtered total medial MyoII levels (see Methods for more details). Pulse temporal landmarks have been defined as follow : ti : initial time; tdmax : max derivative; t max : max amplitude; td min : min derivative; t f : final time. (c) MyoII pulses are automatically detected in space by monitoring the centre of mass of the medial sqh::mKate2 signal over time (see Methods for more details and Supplementary Movie 22). The actual pulse centre used for the <t>KLT</t> analysis is then defined by averaging the position of the recorded centre of mass between td max and td min of the pulse. This time interval corresponds to the period during which the apical surface contract during a pulse. (d) Line plots : Averaged speed towards the pulse according to pulse temporal landmarks (see above) for different distance bins (see legend). The black arrows show the time of maximum speed. (e) Schematics of the numerical model. The black circle depicts the actomyosin pulse, and arrows depict forces applied to boundary elements. Only a fraction of boundary elements is represented.
    Kanade Lucas Tomasi Features Tracking Algorithm Klt, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/kanade-+lucas-tomasi+(klt)+feature-tracking+algorithm/bio_rxiv__680033-401-12-30
    Average 90 stars, based on 1 article reviews
    kanade-lucas-tomasi features tracking algorithm klt - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    (a) Description of the method used to quantify to pulsatile Rho1 activity without cell segmentation (see Methods for more details and Supplementary Movie 16). Basically, isolated clusters of AniRBD::eGFP signal are detected using a DBSCAN algorithm. These clusters are then converted into surface ROIs using convex hulls and overlapping ROIs tracked over time to follow individual pulses. Filters such as min./max. area or min./max. duration are applied to reduce tracking mistakes. Finally, the AniRBD::eGFP pulse amplitude measurements are performed considering the maximum of total fluorescence intensity for each track. (b) MyoII pulses are automatically detected in time following the derivatives of high-pass filtered total medial MyoII levels (see Methods for more details). Pulse temporal landmarks have been defined as follow : ti : initial time; tdmax : max derivative; t max : max amplitude; td min : min derivative; t f : final time. (c) MyoII pulses are automatically detected in space by monitoring the centre of mass of the medial sqh::mKate2 signal over time (see Methods for more details and Supplementary Movie 22). The actual pulse centre used for the KLT analysis is then defined by averaging the position of the recorded centre of mass between td max and td min of the pulse. This time interval corresponds to the period during which the apical surface contract during a pulse. (d) Line plots : Averaged speed towards the pulse according to pulse temporal landmarks (see above) for different distance bins (see legend). The black arrows show the time of maximum speed. (e) Schematics of the numerical model. The black circle depicts the actomyosin pulse, and arrows depict forces applied to boundary elements. Only a fraction of boundary elements is represented.

    Journal: bioRxiv

    Article Title: Assembly of a persistent apical actin network by the formin Frl/Fmnl tunes epithelial cell deformability

    doi: 10.1101/680033

    Figure Lengend Snippet: (a) Description of the method used to quantify to pulsatile Rho1 activity without cell segmentation (see Methods for more details and Supplementary Movie 16). Basically, isolated clusters of AniRBD::eGFP signal are detected using a DBSCAN algorithm. These clusters are then converted into surface ROIs using convex hulls and overlapping ROIs tracked over time to follow individual pulses. Filters such as min./max. area or min./max. duration are applied to reduce tracking mistakes. Finally, the AniRBD::eGFP pulse amplitude measurements are performed considering the maximum of total fluorescence intensity for each track. (b) MyoII pulses are automatically detected in time following the derivatives of high-pass filtered total medial MyoII levels (see Methods for more details). Pulse temporal landmarks have been defined as follow : ti : initial time; tdmax : max derivative; t max : max amplitude; td min : min derivative; t f : final time. (c) MyoII pulses are automatically detected in space by monitoring the centre of mass of the medial sqh::mKate2 signal over time (see Methods for more details and Supplementary Movie 22). The actual pulse centre used for the KLT analysis is then defined by averaging the position of the recorded centre of mass between td max and td min of the pulse. This time interval corresponds to the period during which the apical surface contract during a pulse. (d) Line plots : Averaged speed towards the pulse according to pulse temporal landmarks (see above) for different distance bins (see legend). The black arrows show the time of maximum speed. (e) Schematics of the numerical model. The black circle depicts the actomyosin pulse, and arrows depict forces applied to boundary elements. Only a fraction of boundary elements is represented.

    Article Snippet: We first tracked these apical F-Actin structures using a Kanade-Lucas-Tomasi features tracking algorithm (KLT) , implemented in C (S.Birchfield, retrieved from https://cecas.clemson.edu/~stb/klt ) whose tracking results have been exported to Matlab for further processing.

    Techniques: Activity Assay, Isolation, Fluorescence

    (a) Live F-Actin (eGFP::UtrCH) localization in amnioserosa cells during DC comparing the dynamic of a pulsatile event in a WT and a frl 59/59 cell. Time series : images are extracted from the Supplementary Movie 21 at the indicated time-points, max-proj. (4 x 0.33 µm). The yellow frames show the pulse localization, the red and green outlines/arrows show, respectively, the contracting and the expanding parts of the cell. (b) Zoomed view on a contracting frl 59/59 cell displaying radial F-Actin filaments emanating from the pulse core and capturing the AJs. (c) Schematic representation of a contracting cell in WT or frl 59/59 condition. (d) Measuring the propagation of pulsatile contractility by following discrete apical F-Actin structures using a KLT tracking procedure. Left image : concentric circles showing the distance from a pulse (yellow cross). Right image : single time-point extracted from the Supplementary Movie 22, displaying the color-coded speed of KLT tracked structures toward the pulse centre. The white lines show the segmented cell boundaries. (e) Box plots : averaged speed toward the pulse centre of KLT tracked structures as a function to the distance to the pulse in WT vs frl 59/59 (left) or WT vs Frl OE (right) amnioserosa cells. Data are binned as indicated (distance ± 2.5 µm, e.g. the 5 µm bin contains all tracks within a 2.5 to 7.5 µm distance to the pulse). Line plots : speed toward the pulse as a function to the distance to the pulse averaged per bin. Each shade of grey in the background represents the typical size of an amnioserosa cell radius (~ 8 µm). (f) Representative simulations for different values of λ (Supplementary Movie 23). Left panels depict the initial condition, right panels depict the cell state upon maximal contraction. Green segments indicate that a boundary element is connected to the pulse. The pulse position is the same in the three examples. (g) Diagram : Measuring cell shape irregularity by comparing the convex hull (connecting vertices) and the segmented apical cell surface. Box plots : ratio between the surface of the inward + outward regions and the surface occupied by the convex hull (see ) upon maximal deformation. 200 iterations were performed for each value of λ . For each iteration, the pulse position is chosen randomly within the cell. (h) Line plots : Averaged speed towards the pulse vs. distance to the pulse during the contraction phase. Averages were performed from 200 iterations for each value of λ . For each iteration, the pulse position is chosen randomly within the cell. Box plots (e,g) : extend from 1 st (Q1) to 3 rd (Q3) quartile (Q3-Q1 = IQR), whiskers : S.D. (e) or : Q1 or Q3 ± 1.5 x IQR, horizontal lines : medians, black squares : means. Statistical significance (e,g) : two-sample t-test, NS : p > 5E-2, * : p < 5E-2, ** : p < 5E-3, *** : p < 5E-4, **** : p< 5E-5.

    Journal: bioRxiv

    Article Title: Assembly of a persistent apical actin network by the formin Frl/Fmnl tunes epithelial cell deformability

    doi: 10.1101/680033

    Figure Lengend Snippet: (a) Live F-Actin (eGFP::UtrCH) localization in amnioserosa cells during DC comparing the dynamic of a pulsatile event in a WT and a frl 59/59 cell. Time series : images are extracted from the Supplementary Movie 21 at the indicated time-points, max-proj. (4 x 0.33 µm). The yellow frames show the pulse localization, the red and green outlines/arrows show, respectively, the contracting and the expanding parts of the cell. (b) Zoomed view on a contracting frl 59/59 cell displaying radial F-Actin filaments emanating from the pulse core and capturing the AJs. (c) Schematic representation of a contracting cell in WT or frl 59/59 condition. (d) Measuring the propagation of pulsatile contractility by following discrete apical F-Actin structures using a KLT tracking procedure. Left image : concentric circles showing the distance from a pulse (yellow cross). Right image : single time-point extracted from the Supplementary Movie 22, displaying the color-coded speed of KLT tracked structures toward the pulse centre. The white lines show the segmented cell boundaries. (e) Box plots : averaged speed toward the pulse centre of KLT tracked structures as a function to the distance to the pulse in WT vs frl 59/59 (left) or WT vs Frl OE (right) amnioserosa cells. Data are binned as indicated (distance ± 2.5 µm, e.g. the 5 µm bin contains all tracks within a 2.5 to 7.5 µm distance to the pulse). Line plots : speed toward the pulse as a function to the distance to the pulse averaged per bin. Each shade of grey in the background represents the typical size of an amnioserosa cell radius (~ 8 µm). (f) Representative simulations for different values of λ (Supplementary Movie 23). Left panels depict the initial condition, right panels depict the cell state upon maximal contraction. Green segments indicate that a boundary element is connected to the pulse. The pulse position is the same in the three examples. (g) Diagram : Measuring cell shape irregularity by comparing the convex hull (connecting vertices) and the segmented apical cell surface. Box plots : ratio between the surface of the inward + outward regions and the surface occupied by the convex hull (see ) upon maximal deformation. 200 iterations were performed for each value of λ . For each iteration, the pulse position is chosen randomly within the cell. (h) Line plots : Averaged speed towards the pulse vs. distance to the pulse during the contraction phase. Averages were performed from 200 iterations for each value of λ . For each iteration, the pulse position is chosen randomly within the cell. Box plots (e,g) : extend from 1 st (Q1) to 3 rd (Q3) quartile (Q3-Q1 = IQR), whiskers : S.D. (e) or : Q1 or Q3 ± 1.5 x IQR, horizontal lines : medians, black squares : means. Statistical significance (e,g) : two-sample t-test, NS : p > 5E-2, * : p < 5E-2, ** : p < 5E-3, *** : p < 5E-4, **** : p< 5E-5.

    Article Snippet: We first tracked these apical F-Actin structures using a Kanade-Lucas-Tomasi features tracking algorithm (KLT) , implemented in C (S.Birchfield, retrieved from https://cecas.clemson.edu/~stb/klt ) whose tracking results have been exported to Matlab for further processing.

    Techniques: