Review



graphical user interface (gui) of becquerel  (BIOSAXS GmbH)

 
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    BIOSAXS GmbH graphical user interface (gui) of becquerel
    Schematic overview of the organization of the communication in <t>BECQUEREL</t> . The main interface has two major tasks: (i) controlling all devices at the beamline in a flexible manner and (ii) setting-up and triggering the data collection. All tasks, data collections and beamline optics are initiated through BECQUEREL , but an intermediary agent, the BMS, executes the commands during data collection. The communication is further mediated by an abstract communication layer, TINE, followed by the device specific servers that communicate directly to the hardware. BECQUEREL has different profiles for allowing smooth measurement and control of the different sample environments available at P12 ( a , robotic; b , SEC-SAXS; c , stop-flow; d , microfluidic spinning disk; e , in-air samples). Abstraction in the representation of the hardware makes it easy to establish communication following a switch between, for example, the four detectors or the two monochromators available. HFM and VFM refer to horizontal and vertical focusing mirror, respectively.
    Graphical User Interface (Gui) Of Becquerel, supplied by BIOSAXS GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/graphic+user+interface+(gui)+program/graphical+user+interface++gui++of+becquerel/pmc05929361-27-11-13
    Average 90 stars, based on 1 article reviews
    graphical user interface (gui) of becquerel - by Bioz Stars, 2026-11
    90/100 stars

    Images

    1) Product Images from "Integrated beamline control and data acquisition for small-angle X-ray scattering at the P12 BioSAXS beamline at PETRAIII storage ring DESY"

    Article Title: Integrated beamline control and data acquisition for small-angle X-ray scattering at the P12 BioSAXS beamline at PETRAIII storage ring DESY

    Journal: Journal of Synchrotron Radiation

    doi: 10.1107/S1600577518005398

    Schematic overview of the organization of the communication in BECQUEREL . The main interface has two major tasks: (i) controlling all devices at the beamline in a flexible manner and (ii) setting-up and triggering the data collection. All tasks, data collections and beamline optics are initiated through BECQUEREL , but an intermediary agent, the BMS, executes the commands during data collection. The communication is further mediated by an abstract communication layer, TINE, followed by the device specific servers that communicate directly to the hardware. BECQUEREL has different profiles for allowing smooth measurement and control of the different sample environments available at P12 ( a , robotic; b , SEC-SAXS; c , stop-flow; d , microfluidic spinning disk; e , in-air samples). Abstraction in the representation of the hardware makes it easy to establish communication following a switch between, for example, the four detectors or the two monochromators available. HFM and VFM refer to horizontal and vertical focusing mirror, respectively.
    Figure Legend Snippet: Schematic overview of the organization of the communication in BECQUEREL . The main interface has two major tasks: (i) controlling all devices at the beamline in a flexible manner and (ii) setting-up and triggering the data collection. All tasks, data collections and beamline optics are initiated through BECQUEREL , but an intermediary agent, the BMS, executes the commands during data collection. The communication is further mediated by an abstract communication layer, TINE, followed by the device specific servers that communicate directly to the hardware. BECQUEREL has different profiles for allowing smooth measurement and control of the different sample environments available at P12 ( a , robotic; b , SEC-SAXS; c , stop-flow; d , microfluidic spinning disk; e , in-air samples). Abstraction in the representation of the hardware makes it easy to establish communication following a switch between, for example, the four detectors or the two monochromators available. HFM and VFM refer to horizontal and vertical focusing mirror, respectively.

    Techniques Used: Control

    Screen-shot of the BECQUEREL GUI. ( a ) Left-most widgets give an overview of monitor readings specific to the profile, and a view of the sample holder (here, robotic sample-changer mode with a capillary view). The central widget accepts sample specifications of the user and displays the well structure of the sample holder. The upper right corner widget contains the status of the BMS and the current command queue. The queue can be paused, cleared and aborted (row of buttons). The Recommender widget (lower right corner) suggests commands and appropriate actions to take to allow for a data collection. Convenient shortcuts in the form of buttons are available in the top row, for submitting measurements and normalization measurements, breaking interlocks and accessing the data-collection directory. ( b ) Plot-tab, here showing transmitted beam over time during a robotic sample changer data collection. ( c ) Hardware tree-tab, with the hardware widget of a guard slit motor shown.
    Figure Legend Snippet: Screen-shot of the BECQUEREL GUI. ( a ) Left-most widgets give an overview of monitor readings specific to the profile, and a view of the sample holder (here, robotic sample-changer mode with a capillary view). The central widget accepts sample specifications of the user and displays the well structure of the sample holder. The upper right corner widget contains the status of the BMS and the current command queue. The queue can be paused, cleared and aborted (row of buttons). The Recommender widget (lower right corner) suggests commands and appropriate actions to take to allow for a data collection. Convenient shortcuts in the form of buttons are available in the top row, for submitting measurements and normalization measurements, breaking interlocks and accessing the data-collection directory. ( b ) Plot-tab, here showing transmitted beam over time during a robotic sample changer data collection. ( c ) Hardware tree-tab, with the hardware widget of a guard slit motor shown.

    Techniques Used:

    Overview of the slit scan functionality in BECQUEREL using the first slit after the monochromator. ( a ) Results of a slit scan with GGCDF and GGPDF fits to the experimental data and numerical derivatives. Re-scans can be made, and data appended to supplement the scan range. ( b ) Result of a fully automated positioning of a slit system. Data represented as beam profiles described by GGPDF are plotted in MATLAB. ( c ) Data from an adaptive scan (three steps) of one slit blade.
    Figure Legend Snippet: Overview of the slit scan functionality in BECQUEREL using the first slit after the monochromator. ( a ) Results of a slit scan with GGCDF and GGPDF fits to the experimental data and numerical derivatives. Re-scans can be made, and data appended to supplement the scan range. ( b ) Result of a fully automated positioning of a slit system. Data represented as beam profiles described by GGPDF are plotted in MATLAB. ( c ) Data from an adaptive scan (three steps) of one slit blade.

    Techniques Used:

    Related Articles

    other:

    Article Title: Integrated beamline control and data acquisition for small-angle X-ray scattering at the P12 BioSAXS beamline at PETRAIII storage ring DESY
    Article Snippet: At the P12 BioSAXS beamline, the graphical user interface (GUI) of BECQUEREL ( Biosaxs Experiment Control QUEue and RELax ) provides the necessary combination of flexibility and automation to efficiently operate a multi-set-up beamline.

    Article Title: Integrated beamline control and data acquisition for small-angle X-ray scattering at the P12 BioSAXS beamline at PETRAIII storage ring DESY
    Article Snippet: At the P12 BioSAXS beamline, the graphical user interface (GUI) of BECQUEREL (Biosaxs Experiment Control QUEue and RELax) provides the necessary combination of flexibility and automation to efficiently operate a multi-set-up beamline.



    Similar Products

    90
    MathWorks Inc matlab-based graphical user interface (gui) program
    Matlab Based Graphical User Interface (Gui) Program, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/graphic+user+interface+(gui)+program/pm39288720-163-4-2
    Average 90 stars, based on 1 article reviews
    matlab-based graphical user interface (gui) program - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc graphical user interface (gui) program
    Graphical User Interface (Gui) Program, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/graphic+user+interface+(gui)+program/pmc11359294-155-10-11
    Average 90 stars, based on 1 article reviews
    graphical user interface (gui) program - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    SoftBank Robotics gui (graphical user interface) based programming environment
    Gui (Graphical User Interface) Based Programming Environment, supplied by SoftBank Robotics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/graphic+user+interface+(gui)+program/gui++graphical+user+interface++based+programming+environment/10__21015_slash_vtse__v12i2__1836-70-8-17
    Average 90 stars, based on 1 article reviews
    gui (graphical user interface) based programming environment - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc graphic user interface (gui) of the matlab program
    Graphic User Interface (Gui) Of The Matlab Program, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/graphic+user+interface+(gui)+program/pm38358916__ac3c05233_si_001-104-6-6
    Average 90 stars, based on 1 article reviews
    graphic user interface (gui) of the matlab program - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc graphical user interface (gui; matlab) program
    Graphical User Interface (Gui; Matlab) Program, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/graphic+user+interface+(gui)+program/pm37566384-42-25-29
    Average 90 stars, based on 1 article reviews
    graphical user interface (gui; matlab) program - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc graphical user interface (gui) programmed in
    (A) Block diagram and (B) photograph of the portable DF-HRME imaging system. The distal tip of a thin, flexible fiber optic bundle is enclosed in a 3D-printed probe holder and placed in contact with the tissue epithelium. The probe relays the image to the portable optical system at the proximal end of the bundle. The system is controlled via a <t>GUI</t> on a laptop; high resolution video of microvasculature is displayed in real time without the need for an exogenous contrast agent. (C) Optical diagram of the DF-HRME. Scanning darkfield illumination is used to enable reflectance imaging of microvasculature through the fiber bundle. A DLP is used to project a scanning structured illumination pattern at the proximal face of the fiber bundle; synchronized detection is performed using a CMOS camera. An offset is introduced between the illumination and detection apertures to reduce internal reflection. Arrows indicate the directions of scanning at the probe surfaces, DLP and CMOS camera. DF-HRME: scanning darkfield high-resolution microendoscope; DLP: digital light projector; CMOS: complementary metal-oxide semiconductor camera; GUI: graphical user interface.
    Graphical User Interface (Gui) Programmed In, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/graphic+user+interface+(gui)+program/pmc10581811-59-1-7
    Average 90 stars, based on 1 article reviews
    graphical user interface (gui) programmed in - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc graphical user interface (gui) built within the matlab programming environment
    (A) Block diagram and (B) photograph of the portable DF-HRME imaging system. The distal tip of a thin, flexible fiber optic bundle is enclosed in a 3D-printed probe holder and placed in contact with the tissue epithelium. The probe relays the image to the portable optical system at the proximal end of the bundle. The system is controlled via a <t>GUI</t> on a laptop; high resolution video of microvasculature is displayed in real time without the need for an exogenous contrast agent. (C) Optical diagram of the DF-HRME. Scanning darkfield illumination is used to enable reflectance imaging of microvasculature through the fiber bundle. A DLP is used to project a scanning structured illumination pattern at the proximal face of the fiber bundle; synchronized detection is performed using a CMOS camera. An offset is introduced between the illumination and detection apertures to reduce internal reflection. Arrows indicate the directions of scanning at the probe surfaces, DLP and CMOS camera. DF-HRME: scanning darkfield high-resolution microendoscope; DLP: digital light projector; CMOS: complementary metal-oxide semiconductor camera; GUI: graphical user interface.
    Graphical User Interface (Gui) Built Within The Matlab Programming Environment, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/graphic+user+interface+(gui)+program/pm37251709-208-29-29
    Average 90 stars, based on 1 article reviews
    graphical user interface (gui) built within the matlab programming environment - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc programmed graphic user interface (gui)
    (A) Block diagram and (B) photograph of the portable DF-HRME imaging system. The distal tip of a thin, flexible fiber optic bundle is enclosed in a 3D-printed probe holder and placed in contact with the tissue epithelium. The probe relays the image to the portable optical system at the proximal end of the bundle. The system is controlled via a <t>GUI</t> on a laptop; high resolution video of microvasculature is displayed in real time without the need for an exogenous contrast agent. (C) Optical diagram of the DF-HRME. Scanning darkfield illumination is used to enable reflectance imaging of microvasculature through the fiber bundle. A DLP is used to project a scanning structured illumination pattern at the proximal face of the fiber bundle; synchronized detection is performed using a CMOS camera. An offset is introduced between the illumination and detection apertures to reduce internal reflection. Arrows indicate the directions of scanning at the probe surfaces, DLP and CMOS camera. DF-HRME: scanning darkfield high-resolution microendoscope; DLP: digital light projector; CMOS: complementary metal-oxide semiconductor camera; GUI: graphical user interface.
    Programmed Graphic User Interface (Gui), supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/graphic+user+interface+(gui)+program/10__4236_slash_eng__2023__152007-80-8-14
    Average 90 stars, based on 1 article reviews
    programmed graphic user interface (gui) - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc matlab-based program with a graphical user interface (gui)
    (A) Block diagram and (B) photograph of the portable DF-HRME imaging system. The distal tip of a thin, flexible fiber optic bundle is enclosed in a 3D-printed probe holder and placed in contact with the tissue epithelium. The probe relays the image to the portable optical system at the proximal end of the bundle. The system is controlled via a <t>GUI</t> on a laptop; high resolution video of microvasculature is displayed in real time without the need for an exogenous contrast agent. (C) Optical diagram of the DF-HRME. Scanning darkfield illumination is used to enable reflectance imaging of microvasculature through the fiber bundle. A DLP is used to project a scanning structured illumination pattern at the proximal face of the fiber bundle; synchronized detection is performed using a CMOS camera. An offset is introduced between the illumination and detection apertures to reduce internal reflection. Arrows indicate the directions of scanning at the probe surfaces, DLP and CMOS camera. DF-HRME: scanning darkfield high-resolution microendoscope; DLP: digital light projector; CMOS: complementary metal-oxide semiconductor camera; GUI: graphical user interface.
    Matlab Based Program With A Graphical User Interface (Gui), supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/graphic+user+interface+(gui)+program/pm35888438-198-1-1
    Average 90 stars, based on 1 article reviews
    matlab-based program with a graphical user interface (gui) - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    (A) Block diagram and (B) photograph of the portable DF-HRME imaging system. The distal tip of a thin, flexible fiber optic bundle is enclosed in a 3D-printed probe holder and placed in contact with the tissue epithelium. The probe relays the image to the portable optical system at the proximal end of the bundle. The system is controlled via a GUI on a laptop; high resolution video of microvasculature is displayed in real time without the need for an exogenous contrast agent. (C) Optical diagram of the DF-HRME. Scanning darkfield illumination is used to enable reflectance imaging of microvasculature through the fiber bundle. A DLP is used to project a scanning structured illumination pattern at the proximal face of the fiber bundle; synchronized detection is performed using a CMOS camera. An offset is introduced between the illumination and detection apertures to reduce internal reflection. Arrows indicate the directions of scanning at the probe surfaces, DLP and CMOS camera. DF-HRME: scanning darkfield high-resolution microendoscope; DLP: digital light projector; CMOS: complementary metal-oxide semiconductor camera; GUI: graphical user interface.

    Journal: Biomedical Optics Express

    Article Title: Scanning darkfield high-resolution microendoscope for label-free microvascular imaging

    doi: 10.1364/BOE.498584

    Figure Lengend Snippet: (A) Block diagram and (B) photograph of the portable DF-HRME imaging system. The distal tip of a thin, flexible fiber optic bundle is enclosed in a 3D-printed probe holder and placed in contact with the tissue epithelium. The probe relays the image to the portable optical system at the proximal end of the bundle. The system is controlled via a GUI on a laptop; high resolution video of microvasculature is displayed in real time without the need for an exogenous contrast agent. (C) Optical diagram of the DF-HRME. Scanning darkfield illumination is used to enable reflectance imaging of microvasculature through the fiber bundle. A DLP is used to project a scanning structured illumination pattern at the proximal face of the fiber bundle; synchronized detection is performed using a CMOS camera. An offset is introduced between the illumination and detection apertures to reduce internal reflection. Arrows indicate the directions of scanning at the probe surfaces, DLP and CMOS camera. DF-HRME: scanning darkfield high-resolution microendoscope; DLP: digital light projector; CMOS: complementary metal-oxide semiconductor camera; GUI: graphical user interface.

    Article Snippet: A graphical user interface (GUI) programmed in MATLAB (The MathWorks, Natick, Massachusetts) is implemented on a laptop to control the DF-HRME and display images in real-time.

    Techniques: Blocking Assay, Imaging