Review




Structured Review

GenScript corporation genscript cpass kit
Genscript Cpass Kit, supplied by GenScript corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/genscript+cpass+kit/genscript+cpass+kit/pm37834413-60-22-21
Average 90 stars, based on 1 article reviews
genscript cpass kit - by Bioz Stars, 2026-10
90/100 stars

Images

Related Articles

Enzyme-linked Immunosorbent Assay:

Article Title: Validation of a SARS-CoV-2 Surrogate Neutralization Test Detecting Neutralizing Antibodies against the Major Variants of Concern
Article Snippet: .. In addition, the sVNT performed comparably to two CE-IVD-approved commercial kits, namely the Icosagen SARS-CoV-2 Neutralizing Antibody ELISA kit and the Genscript cPass kit, for the B.1 parental strain and Omicron BA.2. ..

Article Title: Validation of a SARS-CoV-2 Surrogate Neutralization Test Detecting Neutralizing Antibodies against the Major Variants of Concern.
Article Snippet: .. In addition, the sVNT performed comparably to two CE-IVDapproved commercial kits, namely the Icosagen SARS-CoV-2 Neutralizing Antibody ELISA kit and the Genscript cPass kit, for the B.1 parental strain and Omicron BA.2. ..

Article Title: Validation of a SARS-CoV-2 Surrogate Neutralization Test Detecting Neutralizing Antibodies against the Major Variants of Concern.
Article Snippet: .. Comparison of the WT-sVNT performance with two CE-IVD kits, the “Icosagen SARS-CoV-2 Neutralizing Antibody ELISA kit” and the “Genscript cPass, kit” revealed an overall good correlation ranging from 0.8673 to −0.8773 and a midway profile between both commercial kits with 87.76% sensitivity and 90.48% clinical specificity. .. The BA.2-sVNT performance was similar to the BA.2 Genscript test.

Sterility:

Article Title: Combined Subcutaneous-Intranasal Immunization With Epitope-Based Antigens Elicits Binding and Neutralizing Antibody Responses in Serum and Mucosae Against PRRSV-2 and SARS-CoV-2.
Article Snippet: .. Antibiotics (penicillin, streptomycin, and gentamycin) were added to DMEM at standard concentrations to avoid bacterial contamination (see materials and methods), as sera and mucosal fluids were not sterile. (B) SARS-CoV-2 neutralizing capacity of serum and mucosal samples was assessed by quantifying the inhibition of ACE2-RBD interaction using the cPass GenScript kit. ..

Inhibition:

Article Title: Combined Subcutaneous-Intranasal Immunization With Epitope-Based Antigens Elicits Binding and Neutralizing Antibody Responses in Serum and Mucosae Against PRRSV-2 and SARS-CoV-2.
Article Snippet: .. Antibiotics (penicillin, streptomycin, and gentamycin) were added to DMEM at standard concentrations to avoid bacterial contamination (see materials and methods), as sera and mucosal fluids were not sterile. (B) SARS-CoV-2 neutralizing capacity of serum and mucosal samples was assessed by quantifying the inhibition of ACE2-RBD interaction using the cPass GenScript kit. ..

Article Title: First Detection of the SARS-CoV-2 Omicron BA.5/22B in Monaco.
Article Snippet: The analyte concentration of each sample was expressed in U/mL and E/S for anti-RBD and anti-N total binding antibodies, respectively [16]. .. SARSCoV-2 neutralizing antibodies (nAbs) against the Wuhan-Hu-1 strain and the B.A.1.1.529 (Omicron) variant were measured with the GenScript kit (cPass, Piscataway, NJ, USA), a surrogate virus neutralization test (sVNT) whose accuracy was reported elsewhere and results were expressed as inhibition rate (%) and in IU/mL based on WHO international standards [17,18]. .. SARS-CoV-2 genotype screening was performed on nasopharyngeal samples with a multiplex qPCR assay using the Cobas SARS-CoV-2 Variant Set 1 test (RUO) (Roche Diagnostics) on the automated Cobas 6800 system.

Article Title: First Detection of the SARS-CoV-2 Omicron BA.5/22B in Monaco
Article Snippet: The analyte concentration of each sample was expressed in U/mL and E/S for anti-RBD and anti-N total binding antibodies, respectively [ ]. .. SARS-CoV-2 neutralizing antibodies (nAbs) against the Wuhan-Hu-1 strain and the B.A.1.1.529 (Omicron) variant were measured with the GenScript kit (cPass, Piscataway, NJ, USA), a surrogate virus neutralization test (sVNT) whose accuracy was reported elsewhere and results were expressed as inhibition rate (%) and in IU/mL based on WHO international standards [ , ]. .. SARS-CoV-2 genotype screening was performed on nasopharyngeal samples with a multiplex qPCR assay using the Cobas SARS-CoV-2 Variant Set 1 test (RUO) (Roche Diagnostics) on the automated Cobas 6800 system.

Variant Assay:

Article Title: First Detection of the SARS-CoV-2 Omicron BA.5/22B in Monaco.
Article Snippet: The analyte concentration of each sample was expressed in U/mL and E/S for anti-RBD and anti-N total binding antibodies, respectively [16]. .. SARSCoV-2 neutralizing antibodies (nAbs) against the Wuhan-Hu-1 strain and the B.A.1.1.529 (Omicron) variant were measured with the GenScript kit (cPass, Piscataway, NJ, USA), a surrogate virus neutralization test (sVNT) whose accuracy was reported elsewhere and results were expressed as inhibition rate (%) and in IU/mL based on WHO international standards [17,18]. .. SARS-CoV-2 genotype screening was performed on nasopharyngeal samples with a multiplex qPCR assay using the Cobas SARS-CoV-2 Variant Set 1 test (RUO) (Roche Diagnostics) on the automated Cobas 6800 system.

Article Title: First Detection of the SARS-CoV-2 Omicron BA.5/22B in Monaco
Article Snippet: The analyte concentration of each sample was expressed in U/mL and E/S for anti-RBD and anti-N total binding antibodies, respectively [ ]. .. SARS-CoV-2 neutralizing antibodies (nAbs) against the Wuhan-Hu-1 strain and the B.A.1.1.529 (Omicron) variant were measured with the GenScript kit (cPass, Piscataway, NJ, USA), a surrogate virus neutralization test (sVNT) whose accuracy was reported elsewhere and results were expressed as inhibition rate (%) and in IU/mL based on WHO international standards [ , ]. .. SARS-CoV-2 genotype screening was performed on nasopharyngeal samples with a multiplex qPCR assay using the Cobas SARS-CoV-2 Variant Set 1 test (RUO) (Roche Diagnostics) on the automated Cobas 6800 system.

Virus:

Article Title: First Detection of the SARS-CoV-2 Omicron BA.5/22B in Monaco.
Article Snippet: The analyte concentration of each sample was expressed in U/mL and E/S for anti-RBD and anti-N total binding antibodies, respectively [16]. .. SARSCoV-2 neutralizing antibodies (nAbs) against the Wuhan-Hu-1 strain and the B.A.1.1.529 (Omicron) variant were measured with the GenScript kit (cPass, Piscataway, NJ, USA), a surrogate virus neutralization test (sVNT) whose accuracy was reported elsewhere and results were expressed as inhibition rate (%) and in IU/mL based on WHO international standards [17,18]. .. SARS-CoV-2 genotype screening was performed on nasopharyngeal samples with a multiplex qPCR assay using the Cobas SARS-CoV-2 Variant Set 1 test (RUO) (Roche Diagnostics) on the automated Cobas 6800 system.

Article Title: First Detection of the SARS-CoV-2 Omicron BA.5/22B in Monaco
Article Snippet: The analyte concentration of each sample was expressed in U/mL and E/S for anti-RBD and anti-N total binding antibodies, respectively [ ]. .. SARS-CoV-2 neutralizing antibodies (nAbs) against the Wuhan-Hu-1 strain and the B.A.1.1.529 (Omicron) variant were measured with the GenScript kit (cPass, Piscataway, NJ, USA), a surrogate virus neutralization test (sVNT) whose accuracy was reported elsewhere and results were expressed as inhibition rate (%) and in IU/mL based on WHO international standards [ , ]. .. SARS-CoV-2 genotype screening was performed on nasopharyngeal samples with a multiplex qPCR assay using the Cobas SARS-CoV-2 Variant Set 1 test (RUO) (Roche Diagnostics) on the automated Cobas 6800 system.

Neutralization:

Article Title: First Detection of the SARS-CoV-2 Omicron BA.5/22B in Monaco.
Article Snippet: The analyte concentration of each sample was expressed in U/mL and E/S for anti-RBD and anti-N total binding antibodies, respectively [16]. .. SARSCoV-2 neutralizing antibodies (nAbs) against the Wuhan-Hu-1 strain and the B.A.1.1.529 (Omicron) variant were measured with the GenScript kit (cPass, Piscataway, NJ, USA), a surrogate virus neutralization test (sVNT) whose accuracy was reported elsewhere and results were expressed as inhibition rate (%) and in IU/mL based on WHO international standards [17,18]. .. SARS-CoV-2 genotype screening was performed on nasopharyngeal samples with a multiplex qPCR assay using the Cobas SARS-CoV-2 Variant Set 1 test (RUO) (Roche Diagnostics) on the automated Cobas 6800 system.

Article Title: First Detection of the SARS-CoV-2 Omicron BA.5/22B in Monaco
Article Snippet: The analyte concentration of each sample was expressed in U/mL and E/S for anti-RBD and anti-N total binding antibodies, respectively [ ]. .. SARS-CoV-2 neutralizing antibodies (nAbs) against the Wuhan-Hu-1 strain and the B.A.1.1.529 (Omicron) variant were measured with the GenScript kit (cPass, Piscataway, NJ, USA), a surrogate virus neutralization test (sVNT) whose accuracy was reported elsewhere and results were expressed as inhibition rate (%) and in IU/mL based on WHO international standards [ , ]. .. SARS-CoV-2 genotype screening was performed on nasopharyngeal samples with a multiplex qPCR assay using the Cobas SARS-CoV-2 Variant Set 1 test (RUO) (Roche Diagnostics) on the automated Cobas 6800 system.

other:

Article Title: Performance evaluation of four kits for the detection of neutralizing antibody against SARS-CoV-2 in human serum
Article Snippet: The between-run precision was also analyzed using the PBNAs and the Hygeianey, GenScript, and Vazyme detection kits using duplicate test results.

Comparison:

Article Title: Validation of a SARS-CoV-2 Surrogate Neutralization Test Detecting Neutralizing Antibodies against the Major Variants of Concern.
Article Snippet: .. Comparison of the WT-sVNT performance with two CE-IVD kits, the “Icosagen SARS-CoV-2 Neutralizing Antibody ELISA kit” and the “Genscript cPass, kit” revealed an overall good correlation ranging from 0.8673 to −0.8773 and a midway profile between both commercial kits with 87.76% sensitivity and 90.48% clinical specificity. .. The BA.2-sVNT performance was similar to the BA.2 Genscript test.



Similar Products

90
GenScript corporation svnt kit genscript cpass
Svnt Kit Genscript Cpass, supplied by GenScript corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/genscript+cpass+kit/regf+genscript/10__1172_slash_jci181244-223-22-24
Average 90 stars, based on 1 article reviews
svnt kit genscript cpass - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
GenScript corporation cpass sars-cov-2 neutralization antibody detection kit (genscript) targeting ba.5
Cpass Sars Cov 2 Neutralization Antibody Detection Kit (Genscript) Targeting Ba.5, supplied by GenScript corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/genscript+cpass+kit/cpass+sars+cov+2+neutralization+antibody+detection+kit/pm38140877-27-36-45
Average 90 stars, based on 1 article reviews
cpass sars-cov-2 neutralization antibody detection kit (genscript) targeting ba.5 - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
GenScript corporation cpass sars-cov-2 neutralization antibody detection kit (genscript biotech, leiden, the netherlands)
Cpass Sars Cov 2 Neutralization Antibody Detection Kit (Genscript Biotech, Leiden, The Netherlands), supplied by GenScript corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/genscript+cpass+kit/cpass+sars+cov+2+neutralization+antibody+detection+kit/pm38132270-54-2-8
Average 90 stars, based on 1 article reviews
cpass sars-cov-2 neutralization antibody detection kit (genscript biotech, leiden, the netherlands) - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
GenScript corporation genscript cpass kit
Genscript Cpass Kit, supplied by GenScript corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/genscript+cpass+kit/genscript+cpass+kit/pm37834413-60-22-21
Average 90 stars, based on 1 article reviews
genscript cpass kit - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
GenScript corporation genscript cpass, kit
Genscript Cpass, Kit, supplied by GenScript corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/genscript+cpass+kit/genscript+cpass+kit/pm37834413-4-18-18
Average 90 stars, based on 1 article reviews
genscript cpass, kit - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
GenScript corporation sars-cov-2 surrogate virus neutralization test (svnt) by genscript cpass tm sars-cov-2 neutralization antibody detection kit
Sars Cov 2 Surrogate Virus Neutralization Test (Svnt) By Genscript Cpass Tm Sars Cov 2 Neutralization Antibody Detection Kit, supplied by GenScript corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/genscript+cpass+kit/cpass+sars+cov+2+neutralization+antibody+detection+kit/pm36693568-10-30-29
Average 90 stars, based on 1 article reviews
sars-cov-2 surrogate virus neutralization test (svnt) by genscript cpass tm sars-cov-2 neutralization antibody detection kit - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
GenScript corporation elisa based svnt kit genscript cpass sars-cov-2 neutralization antibody detection kit
Comparison of ID50 values determined by the <t>sVNT</t> <t>ELISA</t> kit and iACE2/RBD-Fc model. ID50 values of 7 vaccine serum samples and 4 convalescent plasma samples were determined by the commercial ELISA based sVNT kit and the iACE2/RBD-Fc model. A panel of raw data for determination of neutralization activity of one vaccine serum by the sVNT ELISA kit and the iACE2/RBD-Fc model was shown in (A, B) , respectively. Two sample dilution response inhibition curves generated from the data shown in Panel (A, B) were plotted and shown in (C) . ID50 values of 11 samples determined by the two assays were compared and shown in (D) . The dash line was used to indicated the serum dilution fold with an activity to inhibit 50% binding of the RBD-Fc on the ACE2 bead. p value <0.05 is represented as *.
Elisa Based Svnt Kit Genscript Cpass Sars Cov 2 Neutralization Antibody Detection Kit, supplied by GenScript corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/genscript+cpass+kit/cpass+sars+cov+2+neutralization+antibody+detection+kit/pmc09748424-69-13-17
Average 90 stars, based on 1 article reviews
elisa based svnt kit genscript cpass sars-cov-2 neutralization antibody detection kit - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
GenScript corporation genscript kit cpass
Comparison of ID50 values determined by the <t>sVNT</t> <t>ELISA</t> kit and iACE2/RBD-Fc model. ID50 values of 7 vaccine serum samples and 4 convalescent plasma samples were determined by the commercial ELISA based sVNT kit and the iACE2/RBD-Fc model. A panel of raw data for determination of neutralization activity of one vaccine serum by the sVNT ELISA kit and the iACE2/RBD-Fc model was shown in (A, B) , respectively. Two sample dilution response inhibition curves generated from the data shown in Panel (A, B) were plotted and shown in (C) . ID50 values of 11 samples determined by the two assays were compared and shown in (D) . The dash line was used to indicated the serum dilution fold with an activity to inhibit 50% binding of the RBD-Fc on the ACE2 bead. p value <0.05 is represented as *.
Genscript Kit Cpass, supplied by GenScript corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/genscript+cpass+kit/genscript+cpass+kit/pmc09607325-46-17-17
Average 90 stars, based on 1 article reviews
genscript kit cpass - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results


Comparison of ID50 values determined by the sVNT ELISA kit and iACE2/RBD-Fc model. ID50 values of 7 vaccine serum samples and 4 convalescent plasma samples were determined by the commercial ELISA based sVNT kit and the iACE2/RBD-Fc model. A panel of raw data for determination of neutralization activity of one vaccine serum by the sVNT ELISA kit and the iACE2/RBD-Fc model was shown in (A, B) , respectively. Two sample dilution response inhibition curves generated from the data shown in Panel (A, B) were plotted and shown in (C) . ID50 values of 11 samples determined by the two assays were compared and shown in (D) . The dash line was used to indicated the serum dilution fold with an activity to inhibit 50% binding of the RBD-Fc on the ACE2 bead. p value <0.05 is represented as *.

Journal: Frontiers in Immunology

Article Title: A highly sensitive bead-based flow cytometric competitive binding assay to detect SARS-CoV-2 neutralizing antibody activity

doi: 10.3389/fimmu.2022.1041860

Figure Lengend Snippet: Comparison of ID50 values determined by the sVNT ELISA kit and iACE2/RBD-Fc model. ID50 values of 7 vaccine serum samples and 4 convalescent plasma samples were determined by the commercial ELISA based sVNT kit and the iACE2/RBD-Fc model. A panel of raw data for determination of neutralization activity of one vaccine serum by the sVNT ELISA kit and the iACE2/RBD-Fc model was shown in (A, B) , respectively. Two sample dilution response inhibition curves generated from the data shown in Panel (A, B) were plotted and shown in (C) . ID50 values of 11 samples determined by the two assays were compared and shown in (D) . The dash line was used to indicated the serum dilution fold with an activity to inhibit 50% binding of the RBD-Fc on the ACE2 bead. p value <0.05 is represented as *.

Article Snippet: The ID50 (50% of maximal inhibitory dose) of samples were determined using an ELISA based sVNT kit (GenScript cPass SARS-CoV-2 neutralization Antibody detection kit, GenScript, China) according to instruction of the manufacturer with a minor modification.

Techniques: Comparison, Enzyme-linked Immunosorbent Assay, Clinical Proteomics, Neutralization, Activity Assay, Inhibition, Generated, Binding Assay