Review




Structured Review

COMSOL Inc creeping flow physics
Creeping Flow Physics, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/flow+module/creeping+flow+module/pm24284651-50-2-0
Average 90 stars, based on 1 article reviews
creeping flow physics - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

other:

Article Title: Gout management using uricase and sodium citrate hollow mesoporous nanomotors.
Article Snippet: The COMSOL model employed creeping flow modules and electrostatics.

Article Title: Creep characteristics of muddy siltstone and its engineering application on cross-river tunnel stability
Article Snippet: In the COMSOL, the built-in creep module does not include the rock creep equation described in this article.

Article Title: Creep characteristics of muddy siltstone and its engineering application on cross-river tunnel stability.
Article Snippet: In the COMSOL, the built-in creep module does not include the rock creep equation described in this article.

Article Title: Ion-exchange induced multiple effects to promote uranium uptake from nonmarine water by micromotors.
Article Snippet: COMSOL Multiphysics package was used to simulate the diffusion and electric fields, as well as fluid flow around mAIEX using Transport of Diluted Species, Electrostatics, and Creeping Flow modules (see details in Note S1).

Article Title: Wrinkled microsphere-modified superhydrophobic PTFE fibrous substrate for high-flux oil-water emulsion separation
Article Snippet: Superhydrophobic membrane is promising in treatment of oil–water emulsion wastewater, but its large-scale application is often limited by the lack of facile preparation approach.. Herein, we developed a simple superhydrophobic modification strategy of ultrasonic-spraying wrinkled microspheres into a commercial polytetrafluoroethylene (PTFE) fibrous substrate.. Due to the atomization effect, the sprayed polydimethylsiloxane (PDMS) solution containing ZIF-8@rGO microsphere (~ 0.4 μm) can be uniformly assembled at the surface of the PTFE fibers, which formed a superhydrophobic membrane with a contact angle of about 152.

Article Title: Numerical study on a facing electrode configuration dielectrophoresis microfluidic system for efficient biological cell separation
Article Snippet: COMSOL Multiphysics software has been used to examine the separation mechanism, the efficiency of the microfluidic device, and the impacts of various factors on the cell separation process using a 3D model. To model and simulate this biochip, the Electric Currents, Creeping Flow, and Particle Tracing for Fluid Flow modules were utilized.

Article Title: Multiscale computational analysis of the steady fluid flow through a lymph node.
Article Snippet: We implement this flow in COMSOL using the creeping flow module for the Stokes equation (1), with the TaylorHood element P3 2 − P1 ; this means that, given a triangu- lation T of the domain Ω , we approximate the velocity and the pressure with the piecewise polynomial spaces P 3 2 = ( P2(T) )3 ∩ H1 0 (Ω) and P1 = P1(T) ∩ L20(Ω) , respect ively, where Pk(T) = {g ∈ C(Ω) ∶ g ∈ P2,∀ ∈ T} , H10 (Ω) = {w ∈ H 1(Ω):w | Ω = 0} , L20(Ω) = {w ∈ L 2(Ω) ∶ w | Ω = 0} , H1(Ω) is a Sobolev space and L2(Ω) is a Banach space.

Article Title: Gout management using uricase and sodium citrate hollow mesoporous nanomotors
Article Snippet: The COMSOL model employed creeping flow modules and electrostatics.



Similar Products

96
Repligen Corp filter module
Filter Module, supplied by Repligen Corp, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/flow+module/KrosFlo+KR2i+Tangential+Flow+Filtration+(TFF)+System/10__1177_slash_03913988261471583-2264-3-10
Average 96 stars, based on 1 article reviews
filter module - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

93
Biolin Scientific theta topography flow goniometer
Theta Topography Flow Goniometer, supplied by Biolin Scientific, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/flow+module/Theta+Topography+module/pm41765304-89-24-35
Average 93 stars, based on 1 article reviews
theta topography flow goniometer - by Bioz Stars, 2026-11
93/100 stars
  Buy from Supplier

86
Zaiput Flow Technologies flow chemistry modules
Flow Chemistry Modules, supplied by Zaiput Flow Technologies, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/flow+module/chemistry+flow+modules/pm42120392-278-57-71
Average 86 stars, based on 1 article reviews
flow chemistry modules - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

94
Biolin Scientific flow module
Flow Module, supplied by Biolin Scientific, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/flow+module/QFM+401+Flow+module/pm41922476-249-13-25
Average 94 stars, based on 1 article reviews
flow module - by Bioz Stars, 2026-11
94/100 stars
  Buy from Supplier

86
Transonic Systems Inc perivascular flow module
(A) From superior to inferior and left to right: (1) Right External Jugular Vein – 7 Fr. cannula for central venous pressure (CVP) monitoring, (2) Left External Jugular vein – 7 Fr. triple lumen catheter for for fluid and drug administration, (3) Left Carotid Artery, 3-4mm <t>Perivascular</t> Transonic flow probe, (4) Left Subclavian Artery – 7Fr Cannula for proximal arterial pressure monitoring, (5) Right Brachial Artery, 5Fr. catheter for blood sampling, (6) Brachiocephalic arterial trunk, 6-8mm Perivascular Transonic flow probe, (7) Ascending Aorta (aortic root), 20-24mm Perivascular Transonic flow probe, (8) Left Ventricle, Transonic Pressure-Volume Catheter introduced via apical stick, (9) Proximal Descending Aorta, 12-14mm Perivascular Transonic Flow probe, (10) Left Renal Artery, 3-4 mm Perivascular Transonic Flow probe, (11) Distal Descending Aorta, 6-8 mm Perivascular Transonic flow probe, (12) Right Femoral Artery – 7 Fr. cannula reserved for distal pressure monitoring generally positioned infrarenal, (13) Left Femoral Artery - 9 Fr. cannula for introduction of the balloon catheter (balloon is inflated in the figure), (14) Left Femoral Vein – 9 Fr. MAC catheter for hemorrhage, transfusion and fluid resuscitation via automated Masterflex pump, and (15) Foley catheter for urine collection. Not depicted in the illustration are the endotracheal tube, splenectomy, or rectal temperature probe. We’d like to acknowledge Mr. Jerry Louis Shelton at Texas A&M University for his assistance in generating the pig illustration in panel 1A. (B) Experimental timeline depicting controlled 30-minute hemorrhage period, followed by 30 minutes of aortic occlusion, a 10-minute balloon wean and 3-hour critical care resuscitation phase. Animals were randomized to 10%, 20% or 30% hemorrhage (by volume), and then randomized to either no aortic occlusion, partial REBOA (p-REBOA) and full REBOA (f-REBOA) intervention groups. Autologous blood re-transfusion and balloon weaning occurred between 65–75 minutes, after which a closed-loop critical care algorithm was initiated to maintain target MAP>65 mmHg for three hours (until time 240 minutes).
Perivascular Flow Module, supplied by Transonic Systems Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/flow+module/flow+perivascular+probe/bio_rxiv__64898__2026__02__05__703869-60-8-17
Average 86 stars, based on 1 article reviews
perivascular flow module - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Transonic Systems Inc transonic tubing flow module
(A) From superior to inferior and left to right: (1) Right External Jugular Vein – 7 Fr. cannula for central venous pressure (CVP) monitoring, (2) Left External Jugular vein – 7 Fr. triple lumen catheter for for fluid and drug administration, (3) Left Carotid Artery, 3-4mm <t>Perivascular</t> Transonic flow probe, (4) Left Subclavian Artery – 7Fr Cannula for proximal arterial pressure monitoring, (5) Right Brachial Artery, 5Fr. catheter for blood sampling, (6) Brachiocephalic arterial trunk, 6-8mm Perivascular Transonic flow probe, (7) Ascending Aorta (aortic root), 20-24mm Perivascular Transonic flow probe, (8) Left Ventricle, Transonic Pressure-Volume Catheter introduced via apical stick, (9) Proximal Descending Aorta, 12-14mm Perivascular Transonic Flow probe, (10) Left Renal Artery, 3-4 mm Perivascular Transonic Flow probe, (11) Distal Descending Aorta, 6-8 mm Perivascular Transonic flow probe, (12) Right Femoral Artery – 7 Fr. cannula reserved for distal pressure monitoring generally positioned infrarenal, (13) Left Femoral Artery - 9 Fr. cannula for introduction of the balloon catheter (balloon is inflated in the figure), (14) Left Femoral Vein – 9 Fr. MAC catheter for hemorrhage, transfusion and fluid resuscitation via automated Masterflex pump, and (15) Foley catheter for urine collection. Not depicted in the illustration are the endotracheal tube, splenectomy, or rectal temperature probe. We’d like to acknowledge Mr. Jerry Louis Shelton at Texas A&M University for his assistance in generating the pig illustration in panel 1A. (B) Experimental timeline depicting controlled 30-minute hemorrhage period, followed by 30 minutes of aortic occlusion, a 10-minute balloon wean and 3-hour critical care resuscitation phase. Animals were randomized to 10%, 20% or 30% hemorrhage (by volume), and then randomized to either no aortic occlusion, partial REBOA (p-REBOA) and full REBOA (f-REBOA) intervention groups. Autologous blood re-transfusion and balloon weaning occurred between 65–75 minutes, after which a closed-loop critical care algorithm was initiated to maintain target MAP>65 mmHg for three hours (until time 240 minutes).
Transonic Tubing Flow Module, supplied by Transonic Systems Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/flow+module/flow+meter+tubing/pmc12875343-59-26-30
Average 86 stars, based on 1 article reviews
transonic tubing flow module - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

93
ADInstruments perivascular flow module
(A) From superior to inferior and left to right: (1) Right External Jugular Vein – 7 Fr. cannula for central venous pressure (CVP) monitoring, (2) Left External Jugular vein – 7 Fr. triple lumen catheter for for fluid and drug administration, (3) Left Carotid Artery, 3-4mm <t>Perivascular</t> Transonic flow probe, (4) Left Subclavian Artery – 7Fr Cannula for proximal arterial pressure monitoring, (5) Right Brachial Artery, 5Fr. catheter for blood sampling, (6) Brachiocephalic arterial trunk, 6-8mm Perivascular Transonic flow probe, (7) Ascending Aorta (aortic root), 20-24mm Perivascular Transonic flow probe, (8) Left Ventricle, Transonic Pressure-Volume Catheter introduced via apical stick, (9) Proximal Descending Aorta, 12-14mm Perivascular Transonic Flow probe, (10) Left Renal Artery, 3-4 mm Perivascular Transonic Flow probe, (11) Distal Descending Aorta, 6-8 mm Perivascular Transonic flow probe, (12) Right Femoral Artery – 7 Fr. cannula reserved for distal pressure monitoring generally positioned infrarenal, (13) Left Femoral Artery - 9 Fr. cannula for introduction of the balloon catheter (balloon is inflated in the figure), (14) Left Femoral Vein – 9 Fr. MAC catheter for hemorrhage, transfusion and fluid resuscitation via automated Masterflex pump, and (15) Foley catheter for urine collection. Not depicted in the illustration are the endotracheal tube, splenectomy, or rectal temperature probe. We’d like to acknowledge Mr. Jerry Louis Shelton at Texas A&M University for his assistance in generating the pig illustration in panel 1A. (B) Experimental timeline depicting controlled 30-minute hemorrhage period, followed by 30 minutes of aortic occlusion, a 10-minute balloon wean and 3-hour critical care resuscitation phase. Animals were randomized to 10%, 20% or 30% hemorrhage (by volume), and then randomized to either no aortic occlusion, partial REBOA (p-REBOA) and full REBOA (f-REBOA) intervention groups. Autologous blood re-transfusion and balloon weaning occurred between 65–75 minutes, after which a closed-loop critical care algorithm was initiated to maintain target MAP>65 mmHg for three hours (until time 240 minutes).
Perivascular Flow Module, supplied by ADInstruments, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/flow+module/Perivascular+Flowmeter+Module/pm41419687-59-31-41
Average 93 stars, based on 1 article reviews
perivascular flow module - by Bioz Stars, 2026-11
93/100 stars
  Buy from Supplier

86
Spectrum Labs minikros plus tangential flow filtration module
(A) From superior to inferior and left to right: (1) Right External Jugular Vein – 7 Fr. cannula for central venous pressure (CVP) monitoring, (2) Left External Jugular vein – 7 Fr. triple lumen catheter for for fluid and drug administration, (3) Left Carotid Artery, 3-4mm <t>Perivascular</t> Transonic flow probe, (4) Left Subclavian Artery – 7Fr Cannula for proximal arterial pressure monitoring, (5) Right Brachial Artery, 5Fr. catheter for blood sampling, (6) Brachiocephalic arterial trunk, 6-8mm Perivascular Transonic flow probe, (7) Ascending Aorta (aortic root), 20-24mm Perivascular Transonic flow probe, (8) Left Ventricle, Transonic Pressure-Volume Catheter introduced via apical stick, (9) Proximal Descending Aorta, 12-14mm Perivascular Transonic Flow probe, (10) Left Renal Artery, 3-4 mm Perivascular Transonic Flow probe, (11) Distal Descending Aorta, 6-8 mm Perivascular Transonic flow probe, (12) Right Femoral Artery – 7 Fr. cannula reserved for distal pressure monitoring generally positioned infrarenal, (13) Left Femoral Artery - 9 Fr. cannula for introduction of the balloon catheter (balloon is inflated in the figure), (14) Left Femoral Vein – 9 Fr. MAC catheter for hemorrhage, transfusion and fluid resuscitation via automated Masterflex pump, and (15) Foley catheter for urine collection. Not depicted in the illustration are the endotracheal tube, splenectomy, or rectal temperature probe. We’d like to acknowledge Mr. Jerry Louis Shelton at Texas A&M University for his assistance in generating the pig illustration in panel 1A. (B) Experimental timeline depicting controlled 30-minute hemorrhage period, followed by 30 minutes of aortic occlusion, a 10-minute balloon wean and 3-hour critical care resuscitation phase. Animals were randomized to 10%, 20% or 30% hemorrhage (by volume), and then randomized to either no aortic occlusion, partial REBOA (p-REBOA) and full REBOA (f-REBOA) intervention groups. Autologous blood re-transfusion and balloon weaning occurred between 65–75 minutes, after which a closed-loop critical care algorithm was initiated to maintain target MAP>65 mmHg for three hours (until time 240 minutes).
Minikros Plus Tangential Flow Filtration Module, supplied by Spectrum Labs, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/flow+module/filtration+flow+tangential/us12492232-439-0-6
Average 86 stars, based on 1 article reviews
minikros plus tangential flow filtration module - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

94
Biolin Scientific qfm401
(A) From superior to inferior and left to right: (1) Right External Jugular Vein – 7 Fr. cannula for central venous pressure (CVP) monitoring, (2) Left External Jugular vein – 7 Fr. triple lumen catheter for for fluid and drug administration, (3) Left Carotid Artery, 3-4mm <t>Perivascular</t> Transonic flow probe, (4) Left Subclavian Artery – 7Fr Cannula for proximal arterial pressure monitoring, (5) Right Brachial Artery, 5Fr. catheter for blood sampling, (6) Brachiocephalic arterial trunk, 6-8mm Perivascular Transonic flow probe, (7) Ascending Aorta (aortic root), 20-24mm Perivascular Transonic flow probe, (8) Left Ventricle, Transonic Pressure-Volume Catheter introduced via apical stick, (9) Proximal Descending Aorta, 12-14mm Perivascular Transonic Flow probe, (10) Left Renal Artery, 3-4 mm Perivascular Transonic Flow probe, (11) Distal Descending Aorta, 6-8 mm Perivascular Transonic flow probe, (12) Right Femoral Artery – 7 Fr. cannula reserved for distal pressure monitoring generally positioned infrarenal, (13) Left Femoral Artery - 9 Fr. cannula for introduction of the balloon catheter (balloon is inflated in the figure), (14) Left Femoral Vein – 9 Fr. MAC catheter for hemorrhage, transfusion and fluid resuscitation via automated Masterflex pump, and (15) Foley catheter for urine collection. Not depicted in the illustration are the endotracheal tube, splenectomy, or rectal temperature probe. We’d like to acknowledge Mr. Jerry Louis Shelton at Texas A&M University for his assistance in generating the pig illustration in panel 1A. (B) Experimental timeline depicting controlled 30-minute hemorrhage period, followed by 30 minutes of aortic occlusion, a 10-minute balloon wean and 3-hour critical care resuscitation phase. Animals were randomized to 10%, 20% or 30% hemorrhage (by volume), and then randomized to either no aortic occlusion, partial REBOA (p-REBOA) and full REBOA (f-REBOA) intervention groups. Autologous blood re-transfusion and balloon weaning occurred between 65–75 minutes, after which a closed-loop critical care algorithm was initiated to maintain target MAP>65 mmHg for three hours (until time 240 minutes).
Qfm401, supplied by Biolin Scientific, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/flow+module/QFM+401+Flow+module/pm41331924-168-38-44
Average 94 stars, based on 1 article reviews
qfm401 - by Bioz Stars, 2026-11
94/100 stars
  Buy from Supplier

Image Search Results


(A) From superior to inferior and left to right: (1) Right External Jugular Vein – 7 Fr. cannula for central venous pressure (CVP) monitoring, (2) Left External Jugular vein – 7 Fr. triple lumen catheter for for fluid and drug administration, (3) Left Carotid Artery, 3-4mm Perivascular Transonic flow probe, (4) Left Subclavian Artery – 7Fr Cannula for proximal arterial pressure monitoring, (5) Right Brachial Artery, 5Fr. catheter for blood sampling, (6) Brachiocephalic arterial trunk, 6-8mm Perivascular Transonic flow probe, (7) Ascending Aorta (aortic root), 20-24mm Perivascular Transonic flow probe, (8) Left Ventricle, Transonic Pressure-Volume Catheter introduced via apical stick, (9) Proximal Descending Aorta, 12-14mm Perivascular Transonic Flow probe, (10) Left Renal Artery, 3-4 mm Perivascular Transonic Flow probe, (11) Distal Descending Aorta, 6-8 mm Perivascular Transonic flow probe, (12) Right Femoral Artery – 7 Fr. cannula reserved for distal pressure monitoring generally positioned infrarenal, (13) Left Femoral Artery - 9 Fr. cannula for introduction of the balloon catheter (balloon is inflated in the figure), (14) Left Femoral Vein – 9 Fr. MAC catheter for hemorrhage, transfusion and fluid resuscitation via automated Masterflex pump, and (15) Foley catheter for urine collection. Not depicted in the illustration are the endotracheal tube, splenectomy, or rectal temperature probe. We’d like to acknowledge Mr. Jerry Louis Shelton at Texas A&M University for his assistance in generating the pig illustration in panel 1A. (B) Experimental timeline depicting controlled 30-minute hemorrhage period, followed by 30 minutes of aortic occlusion, a 10-minute balloon wean and 3-hour critical care resuscitation phase. Animals were randomized to 10%, 20% or 30% hemorrhage (by volume), and then randomized to either no aortic occlusion, partial REBOA (p-REBOA) and full REBOA (f-REBOA) intervention groups. Autologous blood re-transfusion and balloon weaning occurred between 65–75 minutes, after which a closed-loop critical care algorithm was initiated to maintain target MAP>65 mmHg for three hours (until time 240 minutes).

Journal: bioRxiv

Article Title: A translational porcine model to assess the graded impact of hemorrhage and aortic occlusion on cardiovascular hemodynamics and renal perfusion

doi: 10.64898/2026.02.05.703869

Figure Lengend Snippet: (A) From superior to inferior and left to right: (1) Right External Jugular Vein – 7 Fr. cannula for central venous pressure (CVP) monitoring, (2) Left External Jugular vein – 7 Fr. triple lumen catheter for for fluid and drug administration, (3) Left Carotid Artery, 3-4mm Perivascular Transonic flow probe, (4) Left Subclavian Artery – 7Fr Cannula for proximal arterial pressure monitoring, (5) Right Brachial Artery, 5Fr. catheter for blood sampling, (6) Brachiocephalic arterial trunk, 6-8mm Perivascular Transonic flow probe, (7) Ascending Aorta (aortic root), 20-24mm Perivascular Transonic flow probe, (8) Left Ventricle, Transonic Pressure-Volume Catheter introduced via apical stick, (9) Proximal Descending Aorta, 12-14mm Perivascular Transonic Flow probe, (10) Left Renal Artery, 3-4 mm Perivascular Transonic Flow probe, (11) Distal Descending Aorta, 6-8 mm Perivascular Transonic flow probe, (12) Right Femoral Artery – 7 Fr. cannula reserved for distal pressure monitoring generally positioned infrarenal, (13) Left Femoral Artery - 9 Fr. cannula for introduction of the balloon catheter (balloon is inflated in the figure), (14) Left Femoral Vein – 9 Fr. MAC catheter for hemorrhage, transfusion and fluid resuscitation via automated Masterflex pump, and (15) Foley catheter for urine collection. Not depicted in the illustration are the endotracheal tube, splenectomy, or rectal temperature probe. We’d like to acknowledge Mr. Jerry Louis Shelton at Texas A&M University for his assistance in generating the pig illustration in panel 1A. (B) Experimental timeline depicting controlled 30-minute hemorrhage period, followed by 30 minutes of aortic occlusion, a 10-minute balloon wean and 3-hour critical care resuscitation phase. Animals were randomized to 10%, 20% or 30% hemorrhage (by volume), and then randomized to either no aortic occlusion, partial REBOA (p-REBOA) and full REBOA (f-REBOA) intervention groups. Autologous blood re-transfusion and balloon weaning occurred between 65–75 minutes, after which a closed-loop critical care algorithm was initiated to maintain target MAP>65 mmHg for three hours (until time 240 minutes).

Article Snippet: To monitor the hemodynamic response, we used a Perivascular Flow Module with six ultrasonic flow probes (TS420, Transonic Systems Inc., Ithaca, NY).

Techniques: Sampling