Review



reconstruction method fbp algorithm with convolution kernel h31s  (Siemens AG)

 
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Siemens AG reconstruction method fbp algorithm with convolution kernel h31s
    Reconstruction Method Fbp Algorithm With Convolution Kernel H31s, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fbp+reconstruction+algorithm/moderately+soft+kernel+siemens+h31s/pmc05127821-79-54-54
    Average 90 stars, based on 1 article reviews
    reconstruction method fbp algorithm with convolution kernel h31s - by Bioz Stars, 2026-11
    90/100 stars

    Images

    Related Articles

    other:

    Article Title: Variations in Determining Actual Orientations of Segmented Deep Brain Stimulation Leads Using the DiODe Algorithm: A Retrospective Study Across Different Lead Designs and Medical Institutions.
    Article Snippet: Introduction: Directional deep brain stimulation (DBS) leads have become widely used in the past decade.. Understanding the asymmetric stimulation provided by directional leads requires precise knowledge of the exact orientation of the lead in respect to its anatomical target.. Recently, the DiODe algorithm was developed to automatically determine the orientation angle of leads from the artifact on postoperative computed tomography (CT) images.

    Article Title: Automated brain computed tomographic densitometry of early ischemic changes in acute stroke
    Article Snippet: Axial slices were reconstructed with a thickness of 1.0 mm and a 0.64 0.12 mm (mean SD) increment, using a moderately soft kernel (Siemens “H31s”) and a 512 × 512 matrix containing the whole brain.

    Article Title: Automated brain computed tomographic densitometry of early ischemic changes in acute stroke
    Article Snippet: Axial slices were reconstructed with a thickness of 1.0 mm and a 0.64 ± 0.12 mm (mean ± SD) increment, using a moderately soft kernel (Siemens “H31s”) and a 512 × 512 matrix containing the whole brain.

    Article Title: Radiation dose reduction with dictionary learning based processing for head CT
    Article Snippet: Other scan parameters include: kVp, 120; slice thickness, 6mm; Gantry rotation time, 0.5s; detector configuration (detector rows×section thickness), 16mm × 1.5mm; pixel spacing: 0.4922mm × 0.4922mm; table feed per gantry rotation, 24mm; pitch, 1:1; reconstruction method: FBP algorithm with convolution kernel “H31s” (“H31s” is the routine smoothing kernel used in reconstructing head images on Siemens CT).

    Article Title: The possibility of identifying brain hemorrhage in putrefied bodies with PMCT
    Article Snippet: The acquired images were reconstructed with a slice thickness of 0.6 mm with an increment of 0.4 mm, and with a slice thickness of 4 mm with an increment of 3 mm, both with a Medium Smooth+ Kernel (Siemens H31s).

    Article Title: AngioCT in the management of neurointerventional patients: a prospective, consecutive series with associated dosimetry and resolution data.
    Article Snippet: Introduction Endovascular coiling of intracranial aneurysms carries a risk of complications.. Early detection and management of complications can improve clinical outcomes.. AngioCT is a new imaging technology enabling CTlike images to be generated on a flat-panel digital subtraction angiography system, which can provide immediate “on angio table” identification and thorough assessment of such complications.



    Similar Products

    90
    Siemens AG fbp reconstruction algorithm
    Fbp Reconstruction Algorithm, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fbp+reconstruction+algorithm/fbp+reconstruction+algorithm/pm37602816-161-1-5
    Average 90 stars, based on 1 article reviews
    fbp reconstruction algorithm - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Philips Healthcare filtered-back projection reconstruction algorithm fbp
    Filtered Back Projection Reconstruction Algorithm Fbp, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fbp+reconstruction+algorithm/filtered+back+projection++fbp+/pm37685359-43-6-10
    Average 90 stars, based on 1 article reviews
    filtered-back projection reconstruction algorithm fbp - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Wolters Kluwer Health fbp reconstruction algorithm
    Fbp Reconstruction Algorithm, supplied by Wolters Kluwer Health, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fbp+reconstruction+algorithm/fbp+reconstruction+algorithm/10__1097_slash_rct__0000000000001251-116-27-3
    Average 90 stars, based on 1 article reviews
    fbp reconstruction algorithm - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Siemens Healthineers reconstruction algorithm fbp
    Reconstruction Algorithm Fbp, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fbp+reconstruction+algorithm/reconstruction+algorithm+fbp/pmc06753441-117-125-33
    Average 90 stars, based on 1 article reviews
    reconstruction algorithm fbp - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Canon inc standard-dose ct reconstructed with fbp algorithm using boost 3d
    Standard Dose Ct Reconstructed With Fbp Algorithm Using Boost 3d, supplied by Canon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fbp+reconstruction+algorithm/standard+dose+ct+reconstructed+with+fbp+algorithm+using+boost+3d/pm30691672-423-20-22
    Average 90 stars, based on 1 article reviews
    standard-dose ct reconstructed with fbp algorithm using boost 3d - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Canon inc reduced-dose ct reconstructed with fbp algorithm using boost 3d
    Reduced Dose Ct Reconstructed With Fbp Algorithm Using Boost 3d, supplied by Canon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fbp+reconstruction+algorithm/standard+dose+ct+reconstructed+with+fbp+algorithm+using+boost+3d/pm30691672-423-31-33
    Average 90 stars, based on 1 article reviews
    reduced-dose ct reconstructed with fbp algorithm using boost 3d - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Philips Healthcare filtered back reconstruction algorithm (fbp)
    Filtered Back Reconstruction Algorithm (Fbp), supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fbp+reconstruction+algorithm/filtered+back+projection++fbp+/pmc06497819-58-10-13
    Average 90 stars, based on 1 article reviews
    filtered back reconstruction algorithm (fbp) - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Philips Healthcare reconstruction algorithms of standard fbp and knowledge-based ir imr
    Reconstruction Algorithms Of Standard Fbp And Knowledge Based Ir Imr, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fbp+reconstruction+algorithm/reconstruction+algorithms+of+standard+fbp+and+knowledge+based+ir+imr/pm29948063-49-12-17
    Average 90 stars, based on 1 article reviews
    reconstruction algorithms of standard fbp and knowledge-based ir imr - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Siemens Healthineers fbp ct reconstruction algorithms
    Fbp Ct Reconstruction Algorithms, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fbp+reconstruction+algorithm/fbp+ct+reconstruction+algorithms/pm24989387-130-14-34
    Average 90 stars, based on 1 article reviews
    fbp ct reconstruction algorithms - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Siemens AG reconstruction method fbp algorithm with convolution kernel h31s
    Reconstruction Method Fbp Algorithm With Convolution Kernel H31s, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fbp+reconstruction+algorithm/moderately+soft+kernel+siemens+h31s/pmc05127821-79-54-54
    Average 90 stars, based on 1 article reviews
    reconstruction method fbp algorithm with convolution kernel h31s - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results