Review



confocal laser scanning microscope zeiss lsm880—fast airy scan  (Carl Zeiss)


Bioz Verified Symbol Carl Zeiss is a verified supplier
Bioz Manufacturer Symbol Carl Zeiss manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Carl Zeiss confocal laser scanning microscope zeiss lsm880—fast airy scan
    Confocal Laser Scanning Microscope Zeiss Lsm880—Fast Airy Scan, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fast+scan+microscope/laser+microscope+scan/pmc07554735-149-5-9
    Average 90 stars, based on 1 article reviews
    confocal laser scanning microscope zeiss lsm880—fast airy scan - by Bioz Stars, 2026-11
    90/100 stars

    Images

    Related Articles

    Microscopy:

    Article Title: DNA-PK inhibition sustains the antitumor innate immune response in Small Cell Lung Cancer
    Article Snippet: .. The subcellular localization was assessed using a confocal microscope (Airy Scan 2, 938 ZEISS, LSM980). .. The relative mean fluorescence intensity (MFI) was analyzed using the ImageJ 939 software (NIH, Bethesda, MD, USA).

    Article Title: Analysis of maturation dynamics and oocyte nuclear quality after rescue-IVM and semi-automated vitrification.
    Article Snippet: STUDY QUESTION: What is the optimal stage (immature vs mature) and most efficient vitrification technique (semi-automated vs manual) to ensure the safety of the rescue-IVM (r-IVM) procedure for oocyte cryopreservation?. SUMMARY ANSWER: Human oocytes should be cryopreserved after r-IVM at the mature stage (r-MII oocytes) by semi-automated or manual vitrification.. WHAT IS KNOWN ALREADY: r-IVM of immature oocytes may increase the number of oocytes cryopreserved for fertility preservation.

    Article Title: Exogenous hydrogen sulfide and NOX2 inhibition mitigate ferroptosis in pressure-induced retinal ganglion cell damage.
    Article Snippet: DAPI containing mounting media (BIOZOL Diagnostica Vertrieb GmbH, Eching, Germany) was used for mounting the slices. .. A confocal fluorescence microscope (Airy Scan confocal, Zeiss) was used to scan the complete retinal tissue at 20-fold magnification. ..

    Article Title: The HISTONE ACETYLTRANSFERASE 1 interacts with CONSTANS to promote flowering in Arabidopsis.
    Article Snippet: 32 33 Chromatin modifications including histone acetylation play essential roles in 34 regulating flowering.. The CBP/p300 family HISTONE ACETYLTRANSFERASE 1 35 (HAC1), which mediates histone acetylation, promotes the process of floral transition; 36 however, the precise mechanism remains largely unclear.. Specifically, how HAC1 is 37 involved in the flowering regulatory network and which genes are the direct targets of 38 HAC1 during flowering regulation are still unknown.

    Article Title: β,β-Dimethylacryloyl Alkannin from Arnebia euchroma Roots Suppresses Triple-Negative Breast Cancer Growth via AKT/Gli1 Signaling.
    Article Snippet: After confirmation of Arnebia euchroma by genetic analysis, we identified the key compounds from the root: alkannin (1), acetylalkannin (2), β-acetoxyisovaleryl alkannin (3), isobutyryl alkannin (4), and β,β-dimethylacryloyl alkannin (DMA) (5).. Among these, DMA most effectively inhibited the proliferation of triple-negative breast cancer (TNBC) cells, with IC50 values of 5.1 μM (MDA-MB-231) and 8.7 μM (MCF10DCIS.com).. DMA and the Hedgehog (Hh) inhibitor Gant61 targeting Gli1 significantly induced apoptosis, as indicated by increased Bax and cleaved PARP, and decreased Bcl-2 levels (p < 0.01) in both cell lines.

    other:

    Article Title: 3D Micropatterned Traction Force Microscopy: A Technique to Control 3D Cell Shape While Measuring Cell-Substrate Force Transmission.
    Article Snippet: To achieve an optimal compromise between spatial and temporal resolution, we used a fast airy-scan confocal microscope (Carl Zeiss Ltd.).

    Article Title: A large-scale sORF screen identifies putative microproteins involved in cancer cell fitness
    Article Snippet: SDS sample buffer (recipe described above) was added to the samples and was boiled for five minutes at 95°C, followed by SDS-PAGE using a 4–20% Mini-PROTEAN TGX Gel (Biorad).

    Article Title: DNA-PK inhibition sustains the antitumor innate immune response in small cell lung cancer
    Article Snippet: Then, Protein A/G Plus-Agarose (Santa Cruz Biotechnology, CA, USA) was added to the protein-antibody complexes, which were incubated with shaking overnight at 4°C.

    Fluorescence:

    Article Title: Exogenous hydrogen sulfide and NOX2 inhibition mitigate ferroptosis in pressure-induced retinal ganglion cell damage.
    Article Snippet: DAPI containing mounting media (BIOZOL Diagnostica Vertrieb GmbH, Eching, Germany) was used for mounting the slices. .. A confocal fluorescence microscope (Airy Scan confocal, Zeiss) was used to scan the complete retinal tissue at 20-fold magnification. ..

    Article Title: The HISTONE ACETYLTRANSFERASE 1 interacts with CONSTANS to promote flowering in Arabidopsis.
    Article Snippet: 32 33 Chromatin modifications including histone acetylation play essential roles in 34 regulating flowering.. The CBP/p300 family HISTONE ACETYLTRANSFERASE 1 35 (HAC1), which mediates histone acetylation, promotes the process of floral transition; 36 however, the precise mechanism remains largely unclear.. Specifically, how HAC1 is 37 involved in the flowering regulatory network and which genes are the direct targets of 38 HAC1 during flowering regulation are still unknown.

    Confocal:

    Article Title: β,β-Dimethylacryloyl Alkannin from Arnebia euchroma Roots Suppresses Triple-Negative Breast Cancer Growth via AKT/Gli1 Signaling.
    Article Snippet: After confirmation of Arnebia euchroma by genetic analysis, we identified the key compounds from the root: alkannin (1), acetylalkannin (2), β-acetoxyisovaleryl alkannin (3), isobutyryl alkannin (4), and β,β-dimethylacryloyl alkannin (DMA) (5).. Among these, DMA most effectively inhibited the proliferation of triple-negative breast cancer (TNBC) cells, with IC50 values of 5.1 μM (MDA-MB-231) and 8.7 μM (MCF10DCIS.com).. DMA and the Hedgehog (Hh) inhibitor Gant61 targeting Gli1 significantly induced apoptosis, as indicated by increased Bax and cleaved PARP, and decreased Bcl-2 levels (p < 0.01) in both cell lines.



    Similar Products

    99
    Olympus fast scan microscope
    Fast Scan Microscope, supplied by Olympus, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fast+scan+microscope/VS120+Virtual+Slide+Microscope+Virtual+Slide+Microscopy/pmc12900355-256-12-15
    Average 99 stars, based on 1 article reviews
    fast scan microscope - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Olympus multispectral fast laser confocal microscope
    Multispectral Fast Laser Confocal Microscope, supplied by Olympus, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fast+scan+microscope/FV3000+Confocal+Laser+Scanning+Microscope/pm40815895-131-6-12
    Average 99 stars, based on 1 article reviews
    multispectral fast laser confocal microscope - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    90
    Carl Zeiss confocal scanning microscope lsm880 with fast airyscan
    Confocal Scanning Microscope Lsm880 With Fast Airyscan, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fast+scan+microscope/browser+image+lsm/pm40664662-86-23-30
    Average 90 stars, based on 1 article reviews
    confocal scanning microscope lsm880 with fast airyscan - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Carl Zeiss lsm880-zeiss confocal laser scanning microscope with fast airyscan
    Lsm880 Zeiss Confocal Laser Scanning Microscope With Fast Airyscan, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fast+scan+microscope/browser+image+lsm/pm40586601-81-42-44
    Average 90 stars, based on 1 article reviews
    lsm880-zeiss confocal laser scanning microscope with fast airyscan - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Miltenyi Biotec ultra-fast laser-scanning multiphoton microscope trimscope ii
    Bone matrix integrity in response to HHP treatment. Human trabecular bone was treated with HHP at 250, 350, and 600 MPa at 10°C for 20 min using 0.9% saline as the pressure-transmitting medium before post-treatment incubation of bone cylinders was conducted at 4°C for 1 h. <t>Multiphoton</t> microscopy images (a–j), showing tissue autofluorescence at 525/50 nm (green; organic matrix components)) and second harmonic generation (SHG) signal at 405/20 nm (blue; fibrillar collagen), using an excitation wavelength of 810 nm. Here, treated bone cylinders (c–h) are compared to untreated bone (a and b) and bone that was autoclaved (i and j) 121°C for 20 min). Scale bar: 100 µm. The collagen I Western blot (k) is based on a native PAGE (1000 ng of protein per band) with the corresponding quantification (l) that was performed using Image Lab quantification of respective band intensities. Mechanical characterization of human trabecular bone cylinders ( n = 9) regarding compressive modulus (m) and strength (n) via a tactile extensometer. Compressive modulus and strength are displayed as means with standard deviation and single values, represented as dots colored according to corresponding bone density values. Statistical analysis of M and N: Kruskal-Wallis test with Dunn’s multiple comparisons test: p > 0.05.
    Ultra Fast Laser Scanning Multiphoton Microscope Trimscope Ii, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fast+scan+microscope/single+beam+multiphoton+microscope+trimscope/pmc12206270-104-7-13
    Average 90 stars, based on 1 article reviews
    ultra-fast laser-scanning multiphoton microscope trimscope ii - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Bruker Corporation atomic force microscope bruker dimension fast scan
    Bone matrix integrity in response to HHP treatment. Human trabecular bone was treated with HHP at 250, 350, and 600 MPa at 10°C for 20 min using 0.9% saline as the pressure-transmitting medium before post-treatment incubation of bone cylinders was conducted at 4°C for 1 h. <t>Multiphoton</t> microscopy images (a–j), showing tissue autofluorescence at 525/50 nm (green; organic matrix components)) and second harmonic generation (SHG) signal at 405/20 nm (blue; fibrillar collagen), using an excitation wavelength of 810 nm. Here, treated bone cylinders (c–h) are compared to untreated bone (a and b) and bone that was autoclaved (i and j) 121°C for 20 min). Scale bar: 100 µm. The collagen I Western blot (k) is based on a native PAGE (1000 ng of protein per band) with the corresponding quantification (l) that was performed using Image Lab quantification of respective band intensities. Mechanical characterization of human trabecular bone cylinders ( n = 9) regarding compressive modulus (m) and strength (n) via a tactile extensometer. Compressive modulus and strength are displayed as means with standard deviation and single values, represented as dots colored according to corresponding bone density values. Statistical analysis of M and N: Kruskal-Wallis test with Dunn’s multiple comparisons test: p > 0.05.
    Atomic Force Microscope Bruker Dimension Fast Scan, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fast+scan+microscope/atomic+force+microscope+dimension+icon/10__1016_slash_j__foodhyd__2025__111671-96-26-32
    Average 90 stars, based on 1 article reviews
    atomic force microscope bruker dimension fast scan - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Carl Zeiss fluorescence confocal laser scanning microscope zeiss lsm 880 with fast airyscan
    Bone matrix integrity in response to HHP treatment. Human trabecular bone was treated with HHP at 250, 350, and 600 MPa at 10°C for 20 min using 0.9% saline as the pressure-transmitting medium before post-treatment incubation of bone cylinders was conducted at 4°C for 1 h. <t>Multiphoton</t> microscopy images (a–j), showing tissue autofluorescence at 525/50 nm (green; organic matrix components)) and second harmonic generation (SHG) signal at 405/20 nm (blue; fibrillar collagen), using an excitation wavelength of 810 nm. Here, treated bone cylinders (c–h) are compared to untreated bone (a and b) and bone that was autoclaved (i and j) 121°C for 20 min). Scale bar: 100 µm. The collagen I Western blot (k) is based on a native PAGE (1000 ng of protein per band) with the corresponding quantification (l) that was performed using Image Lab quantification of respective band intensities. Mechanical characterization of human trabecular bone cylinders ( n = 9) regarding compressive modulus (m) and strength (n) via a tactile extensometer. Compressive modulus and strength are displayed as means with standard deviation and single values, represented as dots colored according to corresponding bone density values. Statistical analysis of M and N: Kruskal-Wallis test with Dunn’s multiple comparisons test: p > 0.05.
    Fluorescence Confocal Laser Scanning Microscope Zeiss Lsm 880 With Fast Airyscan, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fast+scan+microscope/880+confocal+lsm+microscope/10__1021_slash_acselectrochem__5c00053-72-1-5
    Average 90 stars, based on 1 article reviews
    fluorescence confocal laser scanning microscope zeiss lsm 880 with fast airyscan - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    99
    Nikon a1r ultra fast spectral scanning confocal microscope
    Bone matrix integrity in response to HHP treatment. Human trabecular bone was treated with HHP at 250, 350, and 600 MPa at 10°C for 20 min using 0.9% saline as the pressure-transmitting medium before post-treatment incubation of bone cylinders was conducted at 4°C for 1 h. <t>Multiphoton</t> microscopy images (a–j), showing tissue autofluorescence at 525/50 nm (green; organic matrix components)) and second harmonic generation (SHG) signal at 405/20 nm (blue; fibrillar collagen), using an excitation wavelength of 810 nm. Here, treated bone cylinders (c–h) are compared to untreated bone (a and b) and bone that was autoclaved (i and j) 121°C for 20 min). Scale bar: 100 µm. The collagen I Western blot (k) is based on a native PAGE (1000 ng of protein per band) with the corresponding quantification (l) that was performed using Image Lab quantification of respective band intensities. Mechanical characterization of human trabecular bone cylinders ( n = 9) regarding compressive modulus (m) and strength (n) via a tactile extensometer. Compressive modulus and strength are displayed as means with standard deviation and single values, represented as dots colored according to corresponding bone density values. Statistical analysis of M and N: Kruskal-Wallis test with Dunn’s multiple comparisons test: p > 0.05.
    A1r Ultra Fast Spectral Scanning Confocal Microscope, supplied by Nikon, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/fast+scan+microscope/Objectives/pmc10333845__MSB___19___e11267___s010-580-6-5
    Average 99 stars, based on 1 article reviews
    a1r ultra fast spectral scanning confocal microscope - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    Image Search Results


    Bone matrix integrity in response to HHP treatment. Human trabecular bone was treated with HHP at 250, 350, and 600 MPa at 10°C for 20 min using 0.9% saline as the pressure-transmitting medium before post-treatment incubation of bone cylinders was conducted at 4°C for 1 h. Multiphoton microscopy images (a–j), showing tissue autofluorescence at 525/50 nm (green; organic matrix components)) and second harmonic generation (SHG) signal at 405/20 nm (blue; fibrillar collagen), using an excitation wavelength of 810 nm. Here, treated bone cylinders (c–h) are compared to untreated bone (a and b) and bone that was autoclaved (i and j) 121°C for 20 min). Scale bar: 100 µm. The collagen I Western blot (k) is based on a native PAGE (1000 ng of protein per band) with the corresponding quantification (l) that was performed using Image Lab quantification of respective band intensities. Mechanical characterization of human trabecular bone cylinders ( n = 9) regarding compressive modulus (m) and strength (n) via a tactile extensometer. Compressive modulus and strength are displayed as means with standard deviation and single values, represented as dots colored according to corresponding bone density values. Statistical analysis of M and N: Kruskal-Wallis test with Dunn’s multiple comparisons test: p > 0.05.

    Journal: Journal of Tissue Engineering

    Article Title: Comprehensive characterization of cell and tissue responses toward high hydrostatic pressure treatment: Molecular feedback and structural integrity in bone graft processing

    doi: 10.1177/20417314251337193

    Figure Lengend Snippet: Bone matrix integrity in response to HHP treatment. Human trabecular bone was treated with HHP at 250, 350, and 600 MPa at 10°C for 20 min using 0.9% saline as the pressure-transmitting medium before post-treatment incubation of bone cylinders was conducted at 4°C for 1 h. Multiphoton microscopy images (a–j), showing tissue autofluorescence at 525/50 nm (green; organic matrix components)) and second harmonic generation (SHG) signal at 405/20 nm (blue; fibrillar collagen), using an excitation wavelength of 810 nm. Here, treated bone cylinders (c–h) are compared to untreated bone (a and b) and bone that was autoclaved (i and j) 121°C for 20 min). Scale bar: 100 µm. The collagen I Western blot (k) is based on a native PAGE (1000 ng of protein per band) with the corresponding quantification (l) that was performed using Image Lab quantification of respective band intensities. Mechanical characterization of human trabecular bone cylinders ( n = 9) regarding compressive modulus (m) and strength (n) via a tactile extensometer. Compressive modulus and strength are displayed as means with standard deviation and single values, represented as dots colored according to corresponding bone density values. Statistical analysis of M and N: Kruskal-Wallis test with Dunn’s multiple comparisons test: p > 0.05.

    Article Snippet: The multiphoton images were taken utilizing an ultra-fast laser-scanning multiphoton microscope (TriMScope II, LaVision BioTec, Bielefeld, Germany) in combination with a mode-locked femtosecond-pulsed Ti:Sa laser (Chameleon Vision II, Coherent, Santa Clara, CA, USA).

    Techniques: Saline, Incubation, Microscopy, Western Blot, Clear Native PAGE, Standard Deviation