Review



digitalmicrograph  (Gatan Inc)


Bioz Verified Symbol Gatan Inc is a verified supplier
Bioz Manufacturer Symbol Gatan Inc manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 96

    Structured Review

    Gatan Inc digitalmicrograph
    Digitalmicrograph, supplied by Gatan Inc, used in various techniques. Bioz Stars score: 96/100, based on 202 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/elements+software/APEX+Software+for+EDS/pm38248673-54-0-2
    Average 96 stars, based on 202 article reviews
    digitalmicrograph - by Bioz Stars, 2026-09
    96/100 stars

    Images

    Related Articles

    Software:

    Article Title: EBSD Study of Creep‐Induced Lattice Misorientation in MgO‐Particle‐Reinforced Austenitic Steel Composites
    Article Snippet: .. The SEM was equipped with a DigiView EBSD camera system which was controlled via the APEX software package (EDAX, AMETEK, USA). ..

    Article Title: Influence of Electrochemical Oxidation in H 2 SO 4 and H 3 PO 4 on the Electrochemical Behavior of Ti-6Al-4V ELI Alloy in Artificial Biological Media Mimicking Physiological and Pathological Environments
    Article Snippet: .. The morphological features and elemental composition of the oxide films formed on the Ti-6Al-4V ELI alloy are examined using an FEI QUANTA 200 scanning electron microscope (FEI Company, Hillsboro, OH, USA), coupled with an energy-dispersive X-ray spectroscopy (EDS) system operated through EDAX Genesis 5.10 software. ..

    Article Title: Calcium Silicate-Based Cements for Vital Pulp Therapy: Integrated Assessment of Radiopacity, Elemental Composition, and 24-h Pulp Cell Responses
    Article Snippet: Elemental composition was determined using energy-dispersive X-ray spectroscopy (EDX; Thermoscientific Apreo S, Waltham, MA, USA) integrated with the SEM system. .. Quantitative elemental analysis was performed on the total area of each specimen using EDAX Team software (EDAX Inc., Mahwah, NJ, USA). ..

    Article Title: Synthesis and Characterization of Regenerated Cellulose Coated with a Silk Fibroin/Hydroxyapatite Scaffold for Enhanced Adhesion and Proliferation of Preosteoblast Cells
    Article Snippet: .. The elemental composition and large area mapping of the scaffolds were determined using energy-dispersive spectrometry (EDS, Oxford Instruments, X-Max, Iran) and analyzed with APEX software (EDAX Corporation, Mahwah NJ, USA). ..

    Article Title: Salinity-driven shifts in calcareous deposits formed under cathodic protection and influenced by marine biocalcifying bacteria.
    Article Snippet: Calcareous deposits formed under cathodic protection (CP) may be influenced by microbial activity and salinity, particularly in harbours subjected to tidal mixing and freshwater inputs.. This study investigates the impact of the biocalcifying marine bacterium Pseudoalteromonas sp. CD10 on calcareous deposit formation on carbon steel under CP, with a particular attention to salinity effects.. Experiments were conducted in natural and artificial seawater at two NaCl concentrations (100 and 400 mM), representative of low-tide and seawater conditions.

    Article Title: Sustainable glucose meters: Circular economy insights from integrated life cycle assessment and material composition analysis
    Article Snippet: .. Elemental quantification was carried out using EDAX TEAM software and compared against the eZAF Smart Quant database. ..

    Article Title: Synergistic effect of copper( ii ) ions and orthosilicate group in nanosized hydroxyapatite
    Article Snippet: .. The chemical composition of the synthesized materials was analyzed using a field-emission scanning electron microscope (FE-SEM, FEI Nova NanoSEM 230) equipped with an energy-dispersive X-ray spectrometer (EDS, EDAX Apollo X Silicon Drift Detector) operated with Genesis EDAX Microanalysis Software. .. For measurements, the samples were embedded in carbon resin (PolyFast Struers) and pressed using an automatic press (CitoPress-1, Struers).

    Microscopy:

    Article Title: Influence of Electrochemical Oxidation in H 2 SO 4 and H 3 PO 4 on the Electrochemical Behavior of Ti-6Al-4V ELI Alloy in Artificial Biological Media Mimicking Physiological and Pathological Environments
    Article Snippet: .. The morphological features and elemental composition of the oxide films formed on the Ti-6Al-4V ELI alloy are examined using an FEI QUANTA 200 scanning electron microscope (FEI Company, Hillsboro, OH, USA), coupled with an energy-dispersive X-ray spectroscopy (EDS) system operated through EDAX Genesis 5.10 software. ..

    Article Title: Synergistic effect of copper( ii ) ions and orthosilicate group in nanosized hydroxyapatite
    Article Snippet: .. The chemical composition of the synthesized materials was analyzed using a field-emission scanning electron microscope (FE-SEM, FEI Nova NanoSEM 230) equipped with an energy-dispersive X-ray spectrometer (EDS, EDAX Apollo X Silicon Drift Detector) operated with Genesis EDAX Microanalysis Software. .. For measurements, the samples were embedded in carbon resin (PolyFast Struers) and pressed using an automatic press (CitoPress-1, Struers).

    X-ray Spectroscopy:

    Article Title: Influence of Electrochemical Oxidation in H 2 SO 4 and H 3 PO 4 on the Electrochemical Behavior of Ti-6Al-4V ELI Alloy in Artificial Biological Media Mimicking Physiological and Pathological Environments
    Article Snippet: .. The morphological features and elemental composition of the oxide films formed on the Ti-6Al-4V ELI alloy are examined using an FEI QUANTA 200 scanning electron microscope (FEI Company, Hillsboro, OH, USA), coupled with an energy-dispersive X-ray spectroscopy (EDS) system operated through EDAX Genesis 5.10 software. ..

    Synthesized:

    Article Title: Synergistic effect of copper( ii ) ions and orthosilicate group in nanosized hydroxyapatite
    Article Snippet: .. The chemical composition of the synthesized materials was analyzed using a field-emission scanning electron microscope (FE-SEM, FEI Nova NanoSEM 230) equipped with an energy-dispersive X-ray spectrometer (EDS, EDAX Apollo X Silicon Drift Detector) operated with Genesis EDAX Microanalysis Software. .. For measurements, the samples were embedded in carbon resin (PolyFast Struers) and pressed using an automatic press (CitoPress-1, Struers).



    Similar Products

    99
    Nikon nis elements advanced research software
    Nis Elements Advanced Research Software, supplied by Nikon, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/elements+software/NIS-Elements/pmc12907503-295-24-23
    Average 99 stars, based on 1 article reviews
    nis elements advanced research software - by Bioz Stars, 2026-09
    99/100 stars
      Buy from Supplier

    86
    Dassault Systemes finite element analysis software
    Finite Element Analysis Software, supplied by Dassault Systemes, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/elements+software/element+finite+model/pm42308584-281-45-49
    Average 86 stars, based on 1 article reviews
    finite element analysis software - by Bioz Stars, 2026-09
    86/100 stars
      Buy from Supplier

    86
    Abaqus Inc abaqus finite element software
    Abaqus Finite Element Software, supplied by Abaqus Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/elements+software/abaqus+element+finite+software/10__1016_slash_j__jpowsour__2026__240434-62-8-8
    Average 86 stars, based on 1 article reviews
    abaqus finite element software - by Bioz Stars, 2026-09
    86/100 stars
      Buy from Supplier

    86
    Abaqus Inc element software abaqus
    Element Software Abaqus, supplied by Abaqus Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/elements+software/abaqus+element+finite+software/pm42284347-106-13-15
    Average 86 stars, based on 1 article reviews
    element software abaqus - by Bioz Stars, 2026-09
    86/100 stars
      Buy from Supplier

    86
    Abaqus Inc 6 14 finite element software
    6 14 Finite Element Software, supplied by Abaqus Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/elements+software/abaqus+element+finite+software/pm42279914-114-3-2
    Average 86 stars, based on 1 article reviews
    6 14 finite element software - by Bioz Stars, 2026-09
    86/100 stars
      Buy from Supplier

    99
    Nikon nikon nis elements software
    A. brasilense AR mutant exhibits elevated levels of intracellular c-di-GMP. Colony morphology of wild-type A. brasilense Sp7 ( A ) and the AR mutant ( B ) expressing a c-di-GMP biosensor (pFY4535). Cultures were grown for five days at 30 °C on Nfb∗ agar supplemented with KNO 3 . The intracellular c-di-GMP concentration is proportional to the expression of TurboRFP (red), resulting in a red colony color. The AR mutant's more intense coloration indicates higher c-di-GMP accumulation than in the WT. Representative fluorescence microscopy of individual WT and AR mutant cells. Images were captured on a Nikon Eclipse TE2000-U microscope using the following excitation/emission wavelengths: 489/519 nm for AmCyan (green) and 553/574 nm for TurboRFP (red). Gray images are intensity surface plots corresponding to the fluorescence emitted by TurboRFP. Images were processed using Nikon <t>NIS</t> <t>Elements</t> <t>software.</t> All images shown are representative of three independent experiments. Scale bars, 10 mm (colonies); 10 μm (individual cells). (For interpretation of the references to color in this figure legend, the reader is referred to the Web version of this article.)
    Nikon Nis Elements Software, supplied by Nikon, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/elements+software/NIS-Elements/pmc12811640-111-7-7
    Average 99 stars, based on 1 article reviews
    nikon nis elements software - by Bioz Stars, 2026-09
    99/100 stars
      Buy from Supplier

    Image Search Results


    A. brasilense AR mutant exhibits elevated levels of intracellular c-di-GMP. Colony morphology of wild-type A. brasilense Sp7 ( A ) and the AR mutant ( B ) expressing a c-di-GMP biosensor (pFY4535). Cultures were grown for five days at 30 °C on Nfb∗ agar supplemented with KNO 3 . The intracellular c-di-GMP concentration is proportional to the expression of TurboRFP (red), resulting in a red colony color. The AR mutant's more intense coloration indicates higher c-di-GMP accumulation than in the WT. Representative fluorescence microscopy of individual WT and AR mutant cells. Images were captured on a Nikon Eclipse TE2000-U microscope using the following excitation/emission wavelengths: 489/519 nm for AmCyan (green) and 553/574 nm for TurboRFP (red). Gray images are intensity surface plots corresponding to the fluorescence emitted by TurboRFP. Images were processed using Nikon NIS Elements software. All images shown are representative of three independent experiments. Scale bars, 10 mm (colonies); 10 μm (individual cells). (For interpretation of the references to color in this figure legend, the reader is referred to the Web version of this article.)

    Journal: Biofilm

    Article Title: Inactivation of Cysteine Synthase CysK-A enhances flocculation, biofilm formation, and sensitivity to oxidative stress in Azospirillum brasilense Sp7

    doi: 10.1016/j.bioflm.2025.100335

    Figure Lengend Snippet: A. brasilense AR mutant exhibits elevated levels of intracellular c-di-GMP. Colony morphology of wild-type A. brasilense Sp7 ( A ) and the AR mutant ( B ) expressing a c-di-GMP biosensor (pFY4535). Cultures were grown for five days at 30 °C on Nfb∗ agar supplemented with KNO 3 . The intracellular c-di-GMP concentration is proportional to the expression of TurboRFP (red), resulting in a red colony color. The AR mutant's more intense coloration indicates higher c-di-GMP accumulation than in the WT. Representative fluorescence microscopy of individual WT and AR mutant cells. Images were captured on a Nikon Eclipse TE2000-U microscope using the following excitation/emission wavelengths: 489/519 nm for AmCyan (green) and 553/574 nm for TurboRFP (red). Gray images are intensity surface plots corresponding to the fluorescence emitted by TurboRFP. Images were processed using Nikon NIS Elements software. All images shown are representative of three independent experiments. Scale bars, 10 mm (colonies); 10 μm (individual cells). (For interpretation of the references to color in this figure legend, the reader is referred to the Web version of this article.)

    Article Snippet: Obtained images were processed and analyzed using Nikon NIS Elements software.

    Techniques: Mutagenesis, Expressing, Concentration Assay, Fluorescence, Microscopy, Software