2d pc analysis (Medis)
90
Structured Review
Medis
2d pc analysis

2d Pc Analysis, supplied by Medis, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/elements+ar+analysis+2+d+deconvolution+software/2d+pc+analysis/pmc10547653-151-3-10
Average 90 stars, based on 1 article reviews

2d Pc Analysis, supplied by Medis, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/elements+ar+analysis+2+d+deconvolution+software/2d+pc+analysis/pmc10547653-151-3-10
Average 90 stars, based on 1 article reviews
2d pc analysis - by Bioz Stars,
2026-11
90/100 stars
Images
1) Product Images from "Flow evaluation software for four-dimensional flow MRI: a reliability and validation study"
Article Title: Flow evaluation software for four-dimensional flow MRI: a reliability and validation study
Journal: La Radiologia Medica
doi: 10.1007/s11547-023-01697-4
Figure Legend Snippet: Examples of software user interfaces for the 4D flow software programmes at the level of plane definition (panels A – D . A : Arterys; B : Circle; C : Caas; D : Medis) and for 2D flow placement of regions of interest (panel E )
Techniques Used: Software
Figure Legend Snippet: Scatter plots of net flow volume assessment in 188 thoracic arteries by 4D flow compared to 2D PC. Software A – D employing phase-offset correction showed higher linear correlation ( r 0.94–0.97) than without phase-offset correction ( r 0.89). Software A : Arterys; software B : Circle; software C : Caas; software D : Medis
Techniques Used: Software
Figure Legend Snippet: Agreement of net flow volume assessment in 188 thoracic arteries by 4D flow compared to 2D PC. Bland Altman plots show better agreement for software A – D employing phase-offset correction than without phase-offset correction. Limits of agreement (dotted lines) are narrower when phase-offset correction is used. Systematic differences (solid blue lines in the middle) are small with bias < 4 ml (5%) for all methods, but per cent median error is less with phase-offset correction (9–11%) than without (17%). Complete data of Bland Altman analysis is given in Table . Software A : Arterys; software B : Circle; software C : Caas; software D : Medis
Techniques Used: Software
Related Articles
Comparison:Article Title: Flow evaluation software for four-dimensional flow MRI: a reliability and validation study. Article Snippet: Minderhoud et al. [21] found important phase-offset errors in 2D PC acquisitions that needed phantom correction, which however resulted in the same mean net flow for all tested software programmes (Medis QFlow, Circle cvi 42, and MASS). .. A comparison of Article Title: Flow evaluation software for four-dimensional flow MRI: a reliability and validation study Article Snippet: Minderhoud et al. [ ] found important phase-offset errors in 2D PC acquisitions that needed phantom correction, which however resulted in the same mean net flow for all tested software programmes (Medis QFlow, Circle cvi 42, and MASS). .. A comparison of |