Review




Structured Review

fhc inc single tungsten electrodes
Distributions of labeled neurons in visual cortex after injections of CTB into the retinotopic maps in the lateral and inferior pulvinar in two galagos. a-b) Receptive fields for multiunit recordings in the dorsal and ventral maps in the pulvinar of galagos 16–25 and 16–26. The receptive fields are drawn on a depiction of the contralateral lower visual quadrant with 0° corresponding to area centralis of the retina. Receptive fields drawn in blue correspond to retinotopic mapping done using a tungsten <t>electrode.</t> Those fields drawn in red and green were obtained at the dorsal and ventral map injection sites, respectively. Indicated values are the cortical depths at which the circumscribed receptive fields were recorded. c-d) Coronal sections stained for CO overlaid on adjacent sections stained fluorescently for the injected CTB. Injection sites for the dorsal (red) and ventral (green) maps are shown. Scale bar is 1mm, e-f) The locations of populations of labeled neurons projecting to the dorsal map (red) and ventral map (green) in the coronal plane projected at a 45° angle onto the reconstructed dorsolateral surface of cortex. Borders of areas 17, 18, and MT indicated in black. Blue lines indicate tissue blocking cuts. Dashed grey lines indicate every ninth section of tissue. Scale bar is 1cm.
Single Tungsten Electrodes, supplied by fhc inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electron+backscatter+diffraction+ebsd+mapping/tungsten+electrodes+fhc/pmc06506188-122-13-15
Average 90 stars, based on 1 article reviews
single tungsten electrodes - by Bioz Stars, 2026-11
90/100 stars

Images

1) Product Images from "Cortical projections to the two retinotopic maps of primate pulvinar are distinct"

Article Title: Cortical projections to the two retinotopic maps of primate pulvinar are distinct

Journal: The Journal of comparative neurology

doi: 10.1002/cne.24515

Distributions of labeled neurons in visual cortex after injections of CTB into the retinotopic maps in the lateral and inferior pulvinar in two galagos. a-b) Receptive fields for multiunit recordings in the dorsal and ventral maps in the pulvinar of galagos 16–25 and 16–26. The receptive fields are drawn on a depiction of the contralateral lower visual quadrant with 0° corresponding to area centralis of the retina. Receptive fields drawn in blue correspond to retinotopic mapping done using a tungsten electrode. Those fields drawn in red and green were obtained at the dorsal and ventral map injection sites, respectively. Indicated values are the cortical depths at which the circumscribed receptive fields were recorded. c-d) Coronal sections stained for CO overlaid on adjacent sections stained fluorescently for the injected CTB. Injection sites for the dorsal (red) and ventral (green) maps are shown. Scale bar is 1mm, e-f) The locations of populations of labeled neurons projecting to the dorsal map (red) and ventral map (green) in the coronal plane projected at a 45° angle onto the reconstructed dorsolateral surface of cortex. Borders of areas 17, 18, and MT indicated in black. Blue lines indicate tissue blocking cuts. Dashed grey lines indicate every ninth section of tissue. Scale bar is 1cm.
Figure Legend Snippet: Distributions of labeled neurons in visual cortex after injections of CTB into the retinotopic maps in the lateral and inferior pulvinar in two galagos. a-b) Receptive fields for multiunit recordings in the dorsal and ventral maps in the pulvinar of galagos 16–25 and 16–26. The receptive fields are drawn on a depiction of the contralateral lower visual quadrant with 0° corresponding to area centralis of the retina. Receptive fields drawn in blue correspond to retinotopic mapping done using a tungsten electrode. Those fields drawn in red and green were obtained at the dorsal and ventral map injection sites, respectively. Indicated values are the cortical depths at which the circumscribed receptive fields were recorded. c-d) Coronal sections stained for CO overlaid on adjacent sections stained fluorescently for the injected CTB. Injection sites for the dorsal (red) and ventral (green) maps are shown. Scale bar is 1mm, e-f) The locations of populations of labeled neurons projecting to the dorsal map (red) and ventral map (green) in the coronal plane projected at a 45° angle onto the reconstructed dorsolateral surface of cortex. Borders of areas 17, 18, and MT indicated in black. Blue lines indicate tissue blocking cuts. Dashed grey lines indicate every ninth section of tissue. Scale bar is 1cm.

Techniques Used: Labeling, Injection, Staining, Blocking Assay

Related Articles

other:

Article Title: Neural biomarkers of Parkinson's disease
Article Snippet: Neural signals from the first 2 patients were acquired with FHC tungsten electrodes and an FHC data acquisition system (FHC Inc., Bowdoin, ME, USA) with signals split into a Plexon MAP system (Plexon Inc., Dallas, TX, USA); data for the subsequent 20 patients were recorded using “NeuroProbe” tungsten electrodes and Neuro Omega systems (Alpha Omega, Inc., Nazareth, Israel).

Article Title: Suppression of V1 Feedback Produces a Shift in the Topographic Representation of Receptive Fields of LGN Cells by Unmasking Latent Retinal Drives.
Article Snippet: Extracellular single-unit recordings were made in the LGN using tungsten electrodes (FHC, Inc.) of 9–12 Mohm impedance.

Tungsten:

Article Title: Cortical projections to the two retinotopic maps of primate pulvinar are distinct
Article Snippet: .. Pulvinar Injections Parts of the dorsal and ventral retinotopic maps were carefully mapped with single tungsten electrodes (FHC, Inc., ME) at stereotaxic coordinates A-P: 3 mm, M-L: 5.5 mm, using visually evoked potentials in response to a simple stimulus consisting of a spot of light containing a crosshair pattern. ..

Article Title: Evidence for an attentional priority map in inferotemporal cortex
Article Snippet: .. Extracellular recordings were conducted using single Tungsten electrodes (FHC Inc.; impedance ∼20 MΩ at 1 kHz, advanced with a Narishige drive MO-95; Narishige Japan). .. Electrical activity was amplified and filtered for action potential isolation with a band-pass filter at 300 to 8,000 Hz with a Plexon Multichannel Acquisition Processer (MAP) System.

Article Title: Cortical projections to the two retinotopic maps of primate pulvinar are distinct
Article Snippet: .. Parts of the dorsal and ventral retinotopic maps were carefully mapped with single tungsten electrodes (FHC, Inc., ME) at stereotaxic coordinates A-P: 3 mm, M-L: 5.5 mm, using visually evoked potentials in response to a simple stimulus consisting of a spot of light containing a crosshair pattern. ..



Similar Products

99
Hitachi Ltd electron backscattered diffraction ebsd mapping
Electron Backscattered Diffraction Ebsd Mapping, supplied by Hitachi Ltd, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electron+backscatter+diffraction+ebsd+mapping/SU5000/10__1016_slash_j__matdes__2026__117149-102-25-32
Average 99 stars, based on 1 article reviews
electron backscattered diffraction ebsd mapping - by Bioz Stars, 2026-11
99/100 stars
  Buy from Supplier

99
TESCAN USA Inc electron backscattered diffraction ebsd maps
Electron Backscattered Diffraction Ebsd Maps, supplied by TESCAN USA Inc, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electron+backscatter+diffraction+ebsd+mapping/FIB-SEM/10__1016_slash_j__matchar__2025__115510-52-1-11
Average 99 stars, based on 1 article reviews
electron backscattered diffraction ebsd maps - by Bioz Stars, 2026-11
99/100 stars
  Buy from Supplier

97
JEOL electron backscatter diffraction ebsd mapping
Electron Backscatter Diffraction Ebsd Mapping, supplied by JEOL, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electron+backscatter+diffraction+ebsd+mapping/JSM-7001F+Scanning+Electron+Microscope/10__1016_slash_j__msea__2025__148199-122-0-12
Average 97 stars, based on 1 article reviews
electron backscatter diffraction ebsd mapping - by Bioz Stars, 2026-11
97/100 stars
  Buy from Supplier

96
Bruker Corporation electron backscatter diffraction ebsd mapping
Fig. 1. (a) Illustration of typical microstructure of as-deposited cold sprayed Cu after [14]. Small grains due to dynamic recrystallization (DRX) are located near the splat-splat interfaces, while towards the interior of the splats subgrains and deformed large grains are present. The local region of <t>EBSD</t> and nanoindentation mapping in the current study is indicated in (b).
Electron Backscatter Diffraction Ebsd Mapping, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electron+backscatter+diffraction+ebsd+mapping/QUANTAX+EBSD/10__1016_slash_j__msea__2024__147556-67-0-9
Average 96 stars, based on 1 article reviews
electron backscatter diffraction ebsd mapping - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

90
Thermo Fisher electron backscatter diffraction (ebsd) maps
Fig. 1. (a) Illustration of typical microstructure of as-deposited cold sprayed Cu after [14]. Small grains due to dynamic recrystallization (DRX) are located near the splat-splat interfaces, while towards the interior of the splats subgrains and deformed large grains are present. The local region of <t>EBSD</t> and nanoindentation mapping in the current study is indicated in (b).
Electron Backscatter Diffraction (Ebsd) Maps, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electron+backscatter+diffraction+ebsd+mapping/electron+backscatter+diffraction/10__1016_slash_j__jmrt__2024__09__231-58-1-7
Average 90 stars, based on 1 article reviews
electron backscatter diffraction (ebsd) maps - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

98
Oxford Instruments electron backscatter diffraction mapping ebsd
Fig. 1. (a) Illustration of typical microstructure of as-deposited cold sprayed Cu after [14]. Small grains due to dynamic recrystallization (DRX) are located near the splat-splat interfaces, while towards the interior of the splats subgrains and deformed large grains are present. The local region of <t>EBSD</t> and nanoindentation mapping in the current study is indicated in (b).
Electron Backscatter Diffraction Mapping Ebsd, supplied by Oxford Instruments, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electron+backscatter+diffraction+ebsd+mapping/Symmetry/10__1016_slash_j__fusengdes__2024__114528-87-25-32
Average 98 stars, based on 1 article reviews
electron backscatter diffraction mapping ebsd - by Bioz Stars, 2026-11
98/100 stars
  Buy from Supplier

98
Oxford Instruments electron backscattered diffraction ebsd maps
Fig. 1. (a) Illustration of typical microstructure of as-deposited cold sprayed Cu after [14]. Small grains due to dynamic recrystallization (DRX) are located near the splat-splat interfaces, while towards the interior of the splats subgrains and deformed large grains are present. The local region of <t>EBSD</t> and nanoindentation mapping in the current study is indicated in (b).
Electron Backscattered Diffraction Ebsd Maps, supplied by Oxford Instruments, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electron+backscatter+diffraction+ebsd+mapping/Symmetry/10__1016_slash_j__lithos__2023__107375-75-0-9
Average 98 stars, based on 1 article reviews
electron backscattered diffraction ebsd maps - by Bioz Stars, 2026-11
98/100 stars
  Buy from Supplier

96
JEOL electron backscatter diffraction ebsd map
Fig. 1. (a) Illustration of typical microstructure of as-deposited cold sprayed Cu after [14]. Small grains due to dynamic recrystallization (DRX) are located near the splat-splat interfaces, while towards the interior of the splats subgrains and deformed large grains are present. The local region of <t>EBSD</t> and nanoindentation mapping in the current study is indicated in (b).
Electron Backscatter Diffraction Ebsd Map, supplied by JEOL, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electron+backscatter+diffraction+ebsd+mapping/JSM-IT700HR+Scanning+Electron+Microscope/10__1016_slash_j__tecto__2023__230081-99-1-11
Average 96 stars, based on 1 article reviews
electron backscatter diffraction ebsd map - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

98
Oxford Instruments electron backscatter diffraction ebsd mapping
Fig. 1. (a) Illustration of typical microstructure of as-deposited cold sprayed Cu after [14]. Small grains due to dynamic recrystallization (DRX) are located near the splat-splat interfaces, while towards the interior of the splats subgrains and deformed large grains are present. The local region of <t>EBSD</t> and nanoindentation mapping in the current study is indicated in (b).
Electron Backscatter Diffraction Ebsd Mapping, supplied by Oxford Instruments, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electron+backscatter+diffraction+ebsd+mapping/Symmetry/10__1016_slash_j__addma__2023__103499-83-8-21
Average 98 stars, based on 1 article reviews
electron backscatter diffraction ebsd mapping - by Bioz Stars, 2026-11
98/100 stars
  Buy from Supplier

90
ULVAC electron backscatter diffraction (ebsd, ulvac phi-710, kanagawa, japan) mapping
Fig. 1. (a) Illustration of typical microstructure of as-deposited cold sprayed Cu after [14]. Small grains due to dynamic recrystallization (DRX) are located near the splat-splat interfaces, while towards the interior of the splats subgrains and deformed large grains are present. The local region of <t>EBSD</t> and nanoindentation mapping in the current study is indicated in (b).
Electron Backscatter Diffraction (Ebsd, Ulvac Phi 710, Kanagawa, Japan) Mapping, supplied by ULVAC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electron+backscatter+diffraction+ebsd+mapping/phi+710+microprobe/pmc08620976-32-10-6
Average 90 stars, based on 1 article reviews
electron backscatter diffraction (ebsd, ulvac phi-710, kanagawa, japan) mapping - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Fig. 1. (a) Illustration of typical microstructure of as-deposited cold sprayed Cu after [14]. Small grains due to dynamic recrystallization (DRX) are located near the splat-splat interfaces, while towards the interior of the splats subgrains and deformed large grains are present. The local region of EBSD and nanoindentation mapping in the current study is indicated in (b).

Journal: Materials Science and Engineering: A

Article Title: Submicrometer Scale Mapping of Microstructure and Mechanical Properties of Cold Sprayed Copper

doi: 10.1016/j.msea.2024.147556

Figure Lengend Snippet: Fig. 1. (a) Illustration of typical microstructure of as-deposited cold sprayed Cu after [14]. Small grains due to dynamic recrystallization (DRX) are located near the splat-splat interfaces, while towards the interior of the splats subgrains and deformed large grains are present. The local region of EBSD and nanoindentation mapping in the current study is indicated in (b).

Article Snippet: Electron backscatter diffraction (EBSD) mapping was performed using a Bruker QUANTAX EBSD system at 15 kV.

Techniques: Recrystallization

Fig. 3. SEM/EBSD/nanoindentation results of the as-deposited CS-Cu N2 sample: (a) BSE image, (b) SE image, (c) IPF map, (d) GBCD map with the Brandon criterion, (e) KAM map, (f) GND map overlaying with the grain boundaries (misorientation angle >5◦) in black lines, (g) BSE image after nanoindentation, (h) hardness map.

Journal: Materials Science and Engineering: A

Article Title: Submicrometer Scale Mapping of Microstructure and Mechanical Properties of Cold Sprayed Copper

doi: 10.1016/j.msea.2024.147556

Figure Lengend Snippet: Fig. 3. SEM/EBSD/nanoindentation results of the as-deposited CS-Cu N2 sample: (a) BSE image, (b) SE image, (c) IPF map, (d) GBCD map with the Brandon criterion, (e) KAM map, (f) GND map overlaying with the grain boundaries (misorientation angle >5◦) in black lines, (g) BSE image after nanoindentation, (h) hardness map.

Article Snippet: Electron backscatter diffraction (EBSD) mapping was performed using a Bruker QUANTAX EBSD system at 15 kV.

Techniques:

Fig. 4. SEM/EBSD/nanoindentation results of the 350 ◦C annealed CS-Cu N2 sample: (a) BSE image, (b) SE image, (c) IPF map, (d) GBCD map with the Brandon criterion, (e) KAM map, (f) GND map overlaying with the grain boundaries (misorientation angle >5◦) in black lines, (g) BSE image after nanoindentation, (h) hardness map.

Journal: Materials Science and Engineering: A

Article Title: Submicrometer Scale Mapping of Microstructure and Mechanical Properties of Cold Sprayed Copper

doi: 10.1016/j.msea.2024.147556

Figure Lengend Snippet: Fig. 4. SEM/EBSD/nanoindentation results of the 350 ◦C annealed CS-Cu N2 sample: (a) BSE image, (b) SE image, (c) IPF map, (d) GBCD map with the Brandon criterion, (e) KAM map, (f) GND map overlaying with the grain boundaries (misorientation angle >5◦) in black lines, (g) BSE image after nanoindentation, (h) hardness map.

Article Snippet: Electron backscatter diffraction (EBSD) mapping was performed using a Bruker QUANTAX EBSD system at 15 kV.

Techniques: