Review



matrix of seven independently movable electrodes  (Thomas RECORDING)

 
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Thomas RECORDING matrix of seven independently movable electrodes
    Receptive-field diversity measured in pairs of neighboring geniculate cells recorded from the same <t>electrode</t> tip. Response properties of neighboring geniculate cells were compared in paired-cell recordings obtained with the same electrode tip. A: the percentage of neighboring cells with receptive fields overlapped ≤80% was only 19% for neighboring X cells (blue circles) but it was 53% for neighboring YA cells (orange circles) and 58% for neighboring YC cells (green squares). In other words, although most X–X cell pairs (81%) had receptive fields overlapped >80% only 42–47% of Y–Y cell pairs had receptive fields overlapped >80%. The relation between receptive-field overlap and accumulated cell-pair percentage can be accurately fit with exponential functions (R2 = 0.99 for each of the possible pair combinations). The equations of these exponential fits are: XA–XA cell pair: y = 0.11·e0.068x, XA–YA pair: y = 0.42·e0.055x, YA–YA pair: y = 2.19·e0.038x, YC–YC pair: y = 3.39·e0.034x. B: neighboring Y geniculate cells tended to be better matched in their response latencies than neighboring X geniculate cells. The mean peak-time difference of neighboring X cells (6.40 ms) was about 2.5-fold larger than for neighboring YA cells (2.72 ms, P < 0.001, Mann–Whitney test) and 3-fold larger than for neighboring YC cells (2.03 ms, P < 0.001, Mann–Whitney test). Symbols of different sizes are used to represent the number of cell pairs. C: similar comparisons for peak-time ratio. D: similar comparisons for receptive-field size ratio.
    Matrix Of Seven Independently Movable Electrodes, supplied by Thomas RECORDING, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/electrode+matrix/matrix+of+seven+independently+moveable+electrodes/pmc02695628-64-10-28
    Average 90 stars, based on 1 article reviews
    matrix of seven independently movable electrodes - by Bioz Stars, 2026-11
    90/100 stars

    Images

    1) Product Images from "Functional Consequences of Neuronal Divergence Within the Retinogeniculate Pathway"

    Article Title: Functional Consequences of Neuronal Divergence Within the Retinogeniculate Pathway

    Journal: Journal of Neurophysiology

    doi: 10.1152/jn.91088.2008

    Receptive-field diversity measured in pairs of neighboring geniculate cells recorded from the same electrode tip. Response properties of neighboring geniculate cells were compared in paired-cell recordings obtained with the same electrode tip. A: the percentage of neighboring cells with receptive fields overlapped ≤80% was only 19% for neighboring X cells (blue circles) but it was 53% for neighboring YA cells (orange circles) and 58% for neighboring YC cells (green squares). In other words, although most X–X cell pairs (81%) had receptive fields overlapped >80% only 42–47% of Y–Y cell pairs had receptive fields overlapped >80%. The relation between receptive-field overlap and accumulated cell-pair percentage can be accurately fit with exponential functions (R2 = 0.99 for each of the possible pair combinations). The equations of these exponential fits are: XA–XA cell pair: y = 0.11·e0.068x, XA–YA pair: y = 0.42·e0.055x, YA–YA pair: y = 2.19·e0.038x, YC–YC pair: y = 3.39·e0.034x. B: neighboring Y geniculate cells tended to be better matched in their response latencies than neighboring X geniculate cells. The mean peak-time difference of neighboring X cells (6.40 ms) was about 2.5-fold larger than for neighboring YA cells (2.72 ms, P < 0.001, Mann–Whitney test) and 3-fold larger than for neighboring YC cells (2.03 ms, P < 0.001, Mann–Whitney test). Symbols of different sizes are used to represent the number of cell pairs. C: similar comparisons for peak-time ratio. D: similar comparisons for receptive-field size ratio.
    Figure Legend Snippet: Receptive-field diversity measured in pairs of neighboring geniculate cells recorded from the same electrode tip. Response properties of neighboring geniculate cells were compared in paired-cell recordings obtained with the same electrode tip. A: the percentage of neighboring cells with receptive fields overlapped ≤80% was only 19% for neighboring X cells (blue circles) but it was 53% for neighboring YA cells (orange circles) and 58% for neighboring YC cells (green squares). In other words, although most X–X cell pairs (81%) had receptive fields overlapped >80% only 42–47% of Y–Y cell pairs had receptive fields overlapped >80%. The relation between receptive-field overlap and accumulated cell-pair percentage can be accurately fit with exponential functions (R2 = 0.99 for each of the possible pair combinations). The equations of these exponential fits are: XA–XA cell pair: y = 0.11·e0.068x, XA–YA pair: y = 0.42·e0.055x, YA–YA pair: y = 2.19·e0.038x, YC–YC pair: y = 3.39·e0.034x. B: neighboring Y geniculate cells tended to be better matched in their response latencies than neighboring X geniculate cells. The mean peak-time difference of neighboring X cells (6.40 ms) was about 2.5-fold larger than for neighboring YA cells (2.72 ms, P < 0.001, Mann–Whitney test) and 3-fold larger than for neighboring YC cells (2.03 ms, P < 0.001, Mann–Whitney test). Symbols of different sizes are used to represent the number of cell pairs. C: similar comparisons for peak-time ratio. D: similar comparisons for receptive-field size ratio.

    Techniques Used: MANN-WHITNEY

    Related Articles

    other:

    Article Title: Neuronal nonlinearity explains greater visual spatial resolution for darks than lights.
    Article Snippet: Cat. A matrix of seven independently moveable electrodes arranged circularly (Thomas Recording) was used to simultaneously record from multiple geniculate cells with spatially overlapping receptive fields in the A layers of LGN (visual eccentricity 5–20°).

    Article Title: Neuronal nonlinearity explains greater visual spatial resolution for darks than lights
    Article Snippet: A matrix of seven independently moveable electrodes arranged circularly (Thomas Recording) was used to simultaneously record from multiple geniculate cells with spatially overlapping receptive fields in the A layers of LGN (visual eccentricity 5–20°).

    Article Title: Stochastic Generation of Gamma-Band Activity in Primary Visual Cortex of Awake and Anesthetized Monkeys
    Article Snippet: A matrix of seven electrodes (1– 4 M ; Thomas Recording) were arranged linearly and 300 m apart.

    Article Title: Laminar analysis of visually evoked activity in the primary visual cortex
    Article Snippet: A matrix of seven independently moveable electrodes (Thomas Recording) was used to record simultaneously from multiple cortical sites in V1.

    Article Title: Faster Thalamocortical Processing for Dark than Light Visual Targets
    Article Snippet: A matrix of seven independently moveable electrodes arranged circularly (Thomas Recording) was used to simultaneously record from multiple geniculate cells with spatially overlapping receptive fields.

    Article Title: FASTER THALAMOCORTICAL PROCESSING FOR DARK THAN LIGHT VISUAL TARGETS
    Article Snippet: Electrophysiological recordings and data acquisition A matrix of 7 independently moveable electrodes arranged circularly was used to simultaneously record from multiple geniculate cells with spatially overlapping receptive fields (Thomas Recording, Germany).

    Article Title: FASTER THALAMOCORTICAL PROCESSING FOR DARK THAN LIGHT VISUAL TARGETS
    Article Snippet: A matrix of 7 independently moveable electrodes arranged circularly was used to simultaneously record from multiple geniculate cells with spatially overlapping receptive fields (Thomas Recording, Germany).

    Article Title: Stochastic Generation of Gamma-Band Activity in Primary Visual Cortex of Awake and Anesthetized Monkeys
    Article Snippet: A matrix of seven electrodes (1–4 MΩ; Thomas Recording) were arranged linearly and 300 μm apart.



    Similar Products

    94
    NeuroNexus Technologies electrode arrays
    Electrode Arrays, supplied by NeuroNexus Technologies, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/electrode+matrix/Matrix/pmc12894943-245-0-4
    Average 94 stars, based on 1 article reviews
    electrode arrays - by Bioz Stars, 2026-11
    94/100 stars
      Buy from Supplier

    94
    NeuroNexus Technologies 128 channel matrix electrode array
    128 Channel Matrix Electrode Array, supplied by NeuroNexus Technologies, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/electrode+matrix/Matrix/pm40162802-100-23-28
    Average 94 stars, based on 1 article reviews
    128 channel matrix electrode array - by Bioz Stars, 2026-11
    94/100 stars
      Buy from Supplier

    94
    World Precision Instruments matrix electrodes
    Matrix Electrodes, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/electrode+matrix/Constant+Current+Stimulus+Isolator-SYS-A365R/pmc11214061__pnas__2315100121__sapp-141-10-20
    Average 94 stars, based on 1 article reviews
    matrix electrodes - by Bioz Stars, 2026-11
    94/100 stars
      Buy from Supplier

    90
    Thomas RECORDING mini matrix electrode microdrive
    This setup allows movements in 3 translational and 3 rotational axes during online position tracking with IR-cameras. (A) The arch that is holding the <t>microdrive</t> is mounted on two vertical and parallel aluminum beams which allows to change its height. The arch can be rotated along the horizontal line connecting the vertical beams. A set of three linear micromanipulators is mounted on the arch and can be moved along the arch to rotate around the center point of the arch, where the target is placed. The linear micromanipulators can be used to adjust the 3 translational axes and to finally drive the tip of the guide tube down into the tissue. Lastly, the microdrive is connected to the linear micromanipulators on a table that is rotatable 360 degrees. (B) Layout of the CortEXplore System interacting with the TREC Microdrive. The CortEXplore Navigation PC is connected to IR-cameras that are tracking the monkey’s head as well as the microdrive’s position relative to each other. A recording trajectory is defined based on an experimental planning file that utilizes CT and MR imaging. The rotational and translational offsets of the realtime electrode trajectory are then displayed by the CortEXplore system, and the micromanipulators set accordingly to minimize the positioning error. Once the positioning error is minimized on all axes (excluding the penetration axis of the electrode), the TREC Matrix computer advances the electrode out of the guide tube along that axis to the desired target depth (adapted Figure, originally provided by CortEXplore GmbH). (C) Photograph of the setup with a monkey head plastic. Physical objects (red) and their representations in digital 3D space (yellow) are encircled. After co-registration, the stiff connection between the reference geometry A and the monkeys head B, allows positioning of the TREC Mini Matrix C relative to the monkey’s anatomy.
    Mini Matrix Electrode Microdrive, supplied by Thomas RECORDING, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/electrode+matrix/multielectrode+microdrive/pmc11132476-32-1-5
    Average 90 stars, based on 1 article reviews
    mini matrix electrode microdrive - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Warner Instruments disc electrode with an ag/agcl matrix e242
    This setup allows movements in 3 translational and 3 rotational axes during online position tracking with IR-cameras. (A) The arch that is holding the <t>microdrive</t> is mounted on two vertical and parallel aluminum beams which allows to change its height. The arch can be rotated along the horizontal line connecting the vertical beams. A set of three linear micromanipulators is mounted on the arch and can be moved along the arch to rotate around the center point of the arch, where the target is placed. The linear micromanipulators can be used to adjust the 3 translational axes and to finally drive the tip of the guide tube down into the tissue. Lastly, the microdrive is connected to the linear micromanipulators on a table that is rotatable 360 degrees. (B) Layout of the CortEXplore System interacting with the TREC Microdrive. The CortEXplore Navigation PC is connected to IR-cameras that are tracking the monkey’s head as well as the microdrive’s position relative to each other. A recording trajectory is defined based on an experimental planning file that utilizes CT and MR imaging. The rotational and translational offsets of the realtime electrode trajectory are then displayed by the CortEXplore system, and the micromanipulators set accordingly to minimize the positioning error. Once the positioning error is minimized on all axes (excluding the penetration axis of the electrode), the TREC Matrix computer advances the electrode out of the guide tube along that axis to the desired target depth (adapted Figure, originally provided by CortEXplore GmbH). (C) Photograph of the setup with a monkey head plastic. Physical objects (red) and their representations in digital 3D space (yellow) are encircled. After co-registration, the stiff connection between the reference geometry A and the monkeys head B, allows positioning of the TREC Mini Matrix C relative to the monkey’s anatomy.
    Disc Electrode With An Ag/Agcl Matrix E242, supplied by Warner Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/electrode+matrix/ag+agcl+ground+electrode/pm37203783-31-4-11
    Average 90 stars, based on 1 article reviews
    disc electrode with an ag/agcl matrix e242 - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    94
    NeuroNexus Technologies 128 channel matrix electrode arrays
    This setup allows movements in 3 translational and 3 rotational axes during online position tracking with IR-cameras. (A) The arch that is holding the <t>microdrive</t> is mounted on two vertical and parallel aluminum beams which allows to change its height. The arch can be rotated along the horizontal line connecting the vertical beams. A set of three linear micromanipulators is mounted on the arch and can be moved along the arch to rotate around the center point of the arch, where the target is placed. The linear micromanipulators can be used to adjust the 3 translational axes and to finally drive the tip of the guide tube down into the tissue. Lastly, the microdrive is connected to the linear micromanipulators on a table that is rotatable 360 degrees. (B) Layout of the CortEXplore System interacting with the TREC Microdrive. The CortEXplore Navigation PC is connected to IR-cameras that are tracking the monkey’s head as well as the microdrive’s position relative to each other. A recording trajectory is defined based on an experimental planning file that utilizes CT and MR imaging. The rotational and translational offsets of the realtime electrode trajectory are then displayed by the CortEXplore system, and the micromanipulators set accordingly to minimize the positioning error. Once the positioning error is minimized on all axes (excluding the penetration axis of the electrode), the TREC Matrix computer advances the electrode out of the guide tube along that axis to the desired target depth (adapted Figure, originally provided by CortEXplore GmbH). (C) Photograph of the setup with a monkey head plastic. Physical objects (red) and their representations in digital 3D space (yellow) are encircled. After co-registration, the stiff connection between the reference geometry A and the monkeys head B, allows positioning of the TREC Mini Matrix C relative to the monkey’s anatomy.
    128 Channel Matrix Electrode Arrays, supplied by NeuroNexus Technologies, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/electrode+matrix/Matrix/scott_hayden__2023__neural_tuning_in_high_dimensional_stimulus_spaces-1058-16-21
    Average 94 stars, based on 1 article reviews
    128 channel matrix electrode arrays - by Bioz Stars, 2026-11
    94/100 stars
      Buy from Supplier

    90
    Thomas RECORDING 5-channel single electrode system (“mini matrix
    This setup allows movements in 3 translational and 3 rotational axes during online position tracking with IR-cameras. (A) The arch that is holding the <t>microdrive</t> is mounted on two vertical and parallel aluminum beams which allows to change its height. The arch can be rotated along the horizontal line connecting the vertical beams. A set of three linear micromanipulators is mounted on the arch and can be moved along the arch to rotate around the center point of the arch, where the target is placed. The linear micromanipulators can be used to adjust the 3 translational axes and to finally drive the tip of the guide tube down into the tissue. Lastly, the microdrive is connected to the linear micromanipulators on a table that is rotatable 360 degrees. (B) Layout of the CortEXplore System interacting with the TREC Microdrive. The CortEXplore Navigation PC is connected to IR-cameras that are tracking the monkey’s head as well as the microdrive’s position relative to each other. A recording trajectory is defined based on an experimental planning file that utilizes CT and MR imaging. The rotational and translational offsets of the realtime electrode trajectory are then displayed by the CortEXplore system, and the micromanipulators set accordingly to minimize the positioning error. Once the positioning error is minimized on all axes (excluding the penetration axis of the electrode), the TREC Matrix computer advances the electrode out of the guide tube along that axis to the desired target depth (adapted Figure, originally provided by CortEXplore GmbH). (C) Photograph of the setup with a monkey head plastic. Physical objects (red) and their representations in digital 3D space (yellow) are encircled. After co-registration, the stiff connection between the reference geometry A and the monkeys head B, allows positioning of the TREC Mini Matrix C relative to the monkey’s anatomy.
    5 Channel Single Electrode System (“Mini Matrix, supplied by Thomas RECORDING, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/electrode+matrix/5+channel+single+electrode+system++%E2%80%9Cmini+matrix/pmc02824817-91-22-28
    Average 90 stars, based on 1 article reviews
    5-channel single electrode system (“mini matrix - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Blackrock Microsystems LLC utah array electrodes with 4 × 8 matrix shanks
    This setup allows movements in 3 translational and 3 rotational axes during online position tracking with IR-cameras. (A) The arch that is holding the <t>microdrive</t> is mounted on two vertical and parallel aluminum beams which allows to change its height. The arch can be rotated along the horizontal line connecting the vertical beams. A set of three linear micromanipulators is mounted on the arch and can be moved along the arch to rotate around the center point of the arch, where the target is placed. The linear micromanipulators can be used to adjust the 3 translational axes and to finally drive the tip of the guide tube down into the tissue. Lastly, the microdrive is connected to the linear micromanipulators on a table that is rotatable 360 degrees. (B) Layout of the CortEXplore System interacting with the TREC Microdrive. The CortEXplore Navigation PC is connected to IR-cameras that are tracking the monkey’s head as well as the microdrive’s position relative to each other. A recording trajectory is defined based on an experimental planning file that utilizes CT and MR imaging. The rotational and translational offsets of the realtime electrode trajectory are then displayed by the CortEXplore system, and the micromanipulators set accordingly to minimize the positioning error. Once the positioning error is minimized on all axes (excluding the penetration axis of the electrode), the TREC Matrix computer advances the electrode out of the guide tube along that axis to the desired target depth (adapted Figure, originally provided by CortEXplore GmbH). (C) Photograph of the setup with a monkey head plastic. Physical objects (red) and their representations in digital 3D space (yellow) are encircled. After co-registration, the stiff connection between the reference geometry A and the monkeys head B, allows positioning of the TREC Mini Matrix C relative to the monkey’s anatomy.
    Utah Array Electrodes With 4 × 8 Matrix Shanks, supplied by Blackrock Microsystems LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/electrode+matrix/utah+array+electrodes+with+4+%C3%97+8+matrix+shanks/pmc09352796-423-18-37
    Average 90 stars, based on 1 article reviews
    utah array electrodes with 4 × 8 matrix shanks - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    This setup allows movements in 3 translational and 3 rotational axes during online position tracking with IR-cameras. (A) The arch that is holding the microdrive is mounted on two vertical and parallel aluminum beams which allows to change its height. The arch can be rotated along the horizontal line connecting the vertical beams. A set of three linear micromanipulators is mounted on the arch and can be moved along the arch to rotate around the center point of the arch, where the target is placed. The linear micromanipulators can be used to adjust the 3 translational axes and to finally drive the tip of the guide tube down into the tissue. Lastly, the microdrive is connected to the linear micromanipulators on a table that is rotatable 360 degrees. (B) Layout of the CortEXplore System interacting with the TREC Microdrive. The CortEXplore Navigation PC is connected to IR-cameras that are tracking the monkey’s head as well as the microdrive’s position relative to each other. A recording trajectory is defined based on an experimental planning file that utilizes CT and MR imaging. The rotational and translational offsets of the realtime electrode trajectory are then displayed by the CortEXplore system, and the micromanipulators set accordingly to minimize the positioning error. Once the positioning error is minimized on all axes (excluding the penetration axis of the electrode), the TREC Matrix computer advances the electrode out of the guide tube along that axis to the desired target depth (adapted Figure, originally provided by CortEXplore GmbH). (C) Photograph of the setup with a monkey head plastic. Physical objects (red) and their representations in digital 3D space (yellow) are encircled. After co-registration, the stiff connection between the reference geometry A and the monkeys head B, allows positioning of the TREC Mini Matrix C relative to the monkey’s anatomy.

    Journal: PLOS ONE

    Article Title: Using camera-guided electrode microdrive navigation for precise 3D targeting of macaque brain sites

    doi: 10.1371/journal.pone.0301849

    Figure Lengend Snippet: This setup allows movements in 3 translational and 3 rotational axes during online position tracking with IR-cameras. (A) The arch that is holding the microdrive is mounted on two vertical and parallel aluminum beams which allows to change its height. The arch can be rotated along the horizontal line connecting the vertical beams. A set of three linear micromanipulators is mounted on the arch and can be moved along the arch to rotate around the center point of the arch, where the target is placed. The linear micromanipulators can be used to adjust the 3 translational axes and to finally drive the tip of the guide tube down into the tissue. Lastly, the microdrive is connected to the linear micromanipulators on a table that is rotatable 360 degrees. (B) Layout of the CortEXplore System interacting with the TREC Microdrive. The CortEXplore Navigation PC is connected to IR-cameras that are tracking the monkey’s head as well as the microdrive’s position relative to each other. A recording trajectory is defined based on an experimental planning file that utilizes CT and MR imaging. The rotational and translational offsets of the realtime electrode trajectory are then displayed by the CortEXplore system, and the micromanipulators set accordingly to minimize the positioning error. Once the positioning error is minimized on all axes (excluding the penetration axis of the electrode), the TREC Matrix computer advances the electrode out of the guide tube along that axis to the desired target depth (adapted Figure, originally provided by CortEXplore GmbH). (C) Photograph of the setup with a monkey head plastic. Physical objects (red) and their representations in digital 3D space (yellow) are encircled. After co-registration, the stiff connection between the reference geometry A and the monkeys head B, allows positioning of the TREC Mini Matrix C relative to the monkey’s anatomy.

    Article Snippet: The Mini Matrix electrode microdrive (Thomas RECORDING GmbH (TREC), Giessen, Germany; customized for cortEXplore compatibility) and the monkeys head are continuously tracked by cortEXplore’s infrared camera system that allows precise evaluation of electrode positions relative to the target volume while advancing recording electrodes.

    Techniques: Imaging

    The rotational offset of each axis is displayed on top of each axis section with the planned trajectory (blue) and realtime trajectory (red). The red dot along the realtime trajectory equals the guide tube tip of the MiniMatrix. The upper blue dot along the planned trajectory is the planned guide tube tip position, and the lower dot shows the electrode target position. The figure shows the realtime trajectory and positioning errors before the fine adjustment. Rotational offsets, displayed at the top of each window, are minimized first by adjusting the respective micromanipulators (rotational errors in this figure: coronal: 6.74°, sagittal: 7.44°, axial: 74.65°). Afterwards, the translational offset of the realtime trajectory to the target location is minimized using the translational micromanipulators. Once the distance depicted in ‘Tool axis to target’ (here 8.35 mm) in the lower right corner is minimized (close to 0 mm), the microdrive is advanced into the tissue along the tool axis which is matching the guide tube.

    Journal: PLOS ONE

    Article Title: Using camera-guided electrode microdrive navigation for precise 3D targeting of macaque brain sites

    doi: 10.1371/journal.pone.0301849

    Figure Lengend Snippet: The rotational offset of each axis is displayed on top of each axis section with the planned trajectory (blue) and realtime trajectory (red). The red dot along the realtime trajectory equals the guide tube tip of the MiniMatrix. The upper blue dot along the planned trajectory is the planned guide tube tip position, and the lower dot shows the electrode target position. The figure shows the realtime trajectory and positioning errors before the fine adjustment. Rotational offsets, displayed at the top of each window, are minimized first by adjusting the respective micromanipulators (rotational errors in this figure: coronal: 6.74°, sagittal: 7.44°, axial: 74.65°). Afterwards, the translational offset of the realtime trajectory to the target location is minimized using the translational micromanipulators. Once the distance depicted in ‘Tool axis to target’ (here 8.35 mm) in the lower right corner is minimized (close to 0 mm), the microdrive is advanced into the tissue along the tool axis which is matching the guide tube.

    Article Snippet: The Mini Matrix electrode microdrive (Thomas RECORDING GmbH (TREC), Giessen, Germany; customized for cortEXplore compatibility) and the monkeys head are continuously tracked by cortEXplore’s infrared camera system that allows precise evaluation of electrode positions relative to the target volume while advancing recording electrodes.

    Techniques: