Review




Structured Review

Data Sciences International surface electrocardiogram (ecg) p3 plus
Transplantation of gut microbiota from aged mice increases susceptibility to arrhythmia (A) Sample <t>ECG</t> traces of four different types of arrhythmic events: ventricular premature beats (VPB), ventricular tachycardia (VT), atrial fibrillation (AF), and atrioventricular block (AVB). (B) Summary the inducibility of VPB, VT, AF, and AVB in young and aged mice. Numbers in parentheses indicate the number of mice that were induced into VPB, VT, AF, AVB following ISO treated ( n = 6/per group). Data analyzed by Fischer’s exact test. (C) Differences in heart rates, PR intervals, QRS intervals, R amplitude, P duration and P amplitude among young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (D) Representative western blot and quantification of Cx43, Cx40, Nav1.5, Cav1.2, Serca-2A, Kv4.2, IL-6, IL-10, IL-1β, TNF-α, TGF-β, α-SMA, GAPDH in ventricular and atrial tissue of young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). GAPDH was used for internal normalization. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (E) Representative micrographs of Cx43 signal in ventricular and Cx40 in stained atrial sections visualized ( n = 6/per group). Cx43 indicates Connexin 43; Cx40, Connexin 40; ISO, isoproterenol; IL-6, Interleukin-6; TNF-α, tumor necrosis factor-α; TGF-β, transforming growth factor β.
Surface Electrocardiogram (Ecg) P3 Plus, supplied by Data Sciences International, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electrocardiogram+data/surface+electrocardiogram++ecg++p3+plus/pmc11460473-610-0-8
Average 90 stars, based on 1 article reviews
surface electrocardiogram (ecg) p3 plus - by Bioz Stars, 2026-11
90/100 stars

Images

1) Product Images from "Aged gut microbiota promotes arrhythmia susceptibility via oxidative stress"

Article Title: Aged gut microbiota promotes arrhythmia susceptibility via oxidative stress

Journal: iScience

doi: 10.1016/j.isci.2024.110888

Transplantation of gut microbiota from aged mice increases susceptibility to arrhythmia (A) Sample ECG traces of four different types of arrhythmic events: ventricular premature beats (VPB), ventricular tachycardia (VT), atrial fibrillation (AF), and atrioventricular block (AVB). (B) Summary the inducibility of VPB, VT, AF, and AVB in young and aged mice. Numbers in parentheses indicate the number of mice that were induced into VPB, VT, AF, AVB following ISO treated ( n = 6/per group). Data analyzed by Fischer’s exact test. (C) Differences in heart rates, PR intervals, QRS intervals, R amplitude, P duration and P amplitude among young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (D) Representative western blot and quantification of Cx43, Cx40, Nav1.5, Cav1.2, Serca-2A, Kv4.2, IL-6, IL-10, IL-1β, TNF-α, TGF-β, α-SMA, GAPDH in ventricular and atrial tissue of young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). GAPDH was used for internal normalization. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (E) Representative micrographs of Cx43 signal in ventricular and Cx40 in stained atrial sections visualized ( n = 6/per group). Cx43 indicates Connexin 43; Cx40, Connexin 40; ISO, isoproterenol; IL-6, Interleukin-6; TNF-α, tumor necrosis factor-α; TGF-β, transforming growth factor β.
Figure Legend Snippet: Transplantation of gut microbiota from aged mice increases susceptibility to arrhythmia (A) Sample ECG traces of four different types of arrhythmic events: ventricular premature beats (VPB), ventricular tachycardia (VT), atrial fibrillation (AF), and atrioventricular block (AVB). (B) Summary the inducibility of VPB, VT, AF, and AVB in young and aged mice. Numbers in parentheses indicate the number of mice that were induced into VPB, VT, AF, AVB following ISO treated ( n = 6/per group). Data analyzed by Fischer’s exact test. (C) Differences in heart rates, PR intervals, QRS intervals, R amplitude, P duration and P amplitude among young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (D) Representative western blot and quantification of Cx43, Cx40, Nav1.5, Cav1.2, Serca-2A, Kv4.2, IL-6, IL-10, IL-1β, TNF-α, TGF-β, α-SMA, GAPDH in ventricular and atrial tissue of young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). GAPDH was used for internal normalization. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (E) Representative micrographs of Cx43 signal in ventricular and Cx40 in stained atrial sections visualized ( n = 6/per group). Cx43 indicates Connexin 43; Cx40, Connexin 40; ISO, isoproterenol; IL-6, Interleukin-6; TNF-α, tumor necrosis factor-α; TGF-β, transforming growth factor β.

Techniques Used: Transplantation Assay, Blocking Assay, Western Blot, Staining

Vitexin improved aged related arrhythmia through OLA1-Nrf2 signaling pathway (A) Experimental design for testing the anti-aging effect of vitexin on aged mice induced by 150 mg kg D-gal. (B) Sample ECG traces of three different types of arrhythmic events: ventricular premature beats (VPB), atrial fibrillation (AF), and atrioventricular block (AVB). (C) Summary of inducibility of VPB, AF, and AVB in vehicle, and vitexin treated aged mice. Numbers in parentheses indicate the number of mice that were induced into VPB, AF, AVB following ISO treated ( n = 6/per group). Data analyzed by Fischer’s exact test. And differences in heart rates, P-R intervals, QRS intervals, and R amplitude among different group ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (D) The examples of HE, Sirius red staining in the ventricle and atria from different group of mice ( n = 6/per group). Scale bar, 100 μm. Viteixn attenuated fibrosis in aged mice measured by Sirius red staining. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (E and I) Cardiac, serum, colon MDA, SOD and GSH-px levels were quantified using commercial assay kits. ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (F) Representative western blot and quantification of Cx43, Nav1.5, Cav1.2, Serca-2A, Kv4.2, α-SMA, OLA1, Nrf2, GAPDH in ventricle and atria in the four groups ( n = 6/per group). GAPDH was used for internal normalization. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (G) Experimental design for testing the anti-aging effect of Nrf2 activator and inhibitor on aged mice induced by 150 mg kg D-gal. Summary of inducibility of VPB, AF, and AVB in vitexin, DMF, ML385 treated aged mice. Numbers in parentheses indicate the number of mice that were induced into VPB, AF, AVB following ISO treated ( n = 6/per group). Data analyzed by Fischer’s exact test. (H) The examples of HE, Sirius red staining in the ventricle from different group of mice ( n = 6/per group). Scale bar, 100 μm. Viteixn and DMF attenuated fibrosis in aged mice measured by Sirius red staining. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. Serum levels were quantified using commercial assay kits. ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (J) Representative western blot and quantification of Cx43, Nav1.5, Cav1.2, Serca-2A, Kv4.2, α-SMA, OLA1, Nrf2, and GAPDH in ventricle in the four groups ( n = 6/per group). GAPDH was used for internal normalization. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001.
Figure Legend Snippet: Vitexin improved aged related arrhythmia through OLA1-Nrf2 signaling pathway (A) Experimental design for testing the anti-aging effect of vitexin on aged mice induced by 150 mg kg D-gal. (B) Sample ECG traces of three different types of arrhythmic events: ventricular premature beats (VPB), atrial fibrillation (AF), and atrioventricular block (AVB). (C) Summary of inducibility of VPB, AF, and AVB in vehicle, and vitexin treated aged mice. Numbers in parentheses indicate the number of mice that were induced into VPB, AF, AVB following ISO treated ( n = 6/per group). Data analyzed by Fischer’s exact test. And differences in heart rates, P-R intervals, QRS intervals, and R amplitude among different group ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (D) The examples of HE, Sirius red staining in the ventricle and atria from different group of mice ( n = 6/per group). Scale bar, 100 μm. Viteixn attenuated fibrosis in aged mice measured by Sirius red staining. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (E and I) Cardiac, serum, colon MDA, SOD and GSH-px levels were quantified using commercial assay kits. ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (F) Representative western blot and quantification of Cx43, Nav1.5, Cav1.2, Serca-2A, Kv4.2, α-SMA, OLA1, Nrf2, GAPDH in ventricle and atria in the four groups ( n = 6/per group). GAPDH was used for internal normalization. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (G) Experimental design for testing the anti-aging effect of Nrf2 activator and inhibitor on aged mice induced by 150 mg kg D-gal. Summary of inducibility of VPB, AF, and AVB in vitexin, DMF, ML385 treated aged mice. Numbers in parentheses indicate the number of mice that were induced into VPB, AF, AVB following ISO treated ( n = 6/per group). Data analyzed by Fischer’s exact test. (H) The examples of HE, Sirius red staining in the ventricle from different group of mice ( n = 6/per group). Scale bar, 100 μm. Viteixn and DMF attenuated fibrosis in aged mice measured by Sirius red staining. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. Serum levels were quantified using commercial assay kits. ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (J) Representative western blot and quantification of Cx43, Nav1.5, Cav1.2, Serca-2A, Kv4.2, α-SMA, OLA1, Nrf2, and GAPDH in ventricle in the four groups ( n = 6/per group). GAPDH was used for internal normalization. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001.

Techniques Used: Blocking Assay, Staining, Western Blot

Related Articles

Transplantation Assay:

Article Title: Aged gut microbiota promotes arrhythmia susceptibility via oxidative stress
Article Snippet: Surface electrocardiogram (ECG) was monitored by P3 plus (Data Sciences International), 1.5% isoflurane-oxygen mixture was anesthetized, and subcutaneous platinum electrode was placed on lead II.

Blocking Assay:

Article Title: Aged gut microbiota promotes arrhythmia susceptibility via oxidative stress
Article Snippet: Surface electrocardiogram (ECG) was monitored by P3 plus (Data Sciences International), 1.5% isoflurane-oxygen mixture was anesthetized, and subcutaneous platinum electrode was placed on lead II.

Western Blot:

Article Title: Aged gut microbiota promotes arrhythmia susceptibility via oxidative stress
Article Snippet: Surface electrocardiogram (ECG) was monitored by P3 plus (Data Sciences International), 1.5% isoflurane-oxygen mixture was anesthetized, and subcutaneous platinum electrode was placed on lead II.

Staining:

Article Title: Aged gut microbiota promotes arrhythmia susceptibility via oxidative stress
Article Snippet: Surface electrocardiogram (ECG) was monitored by P3 plus (Data Sciences International), 1.5% isoflurane-oxygen mixture was anesthetized, and subcutaneous platinum electrode was placed on lead II.



Similar Products

86
Ryobi Technologies Inc electrocardiogram data
Electrocardiogram Data, supplied by Ryobi Technologies Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electrocardiogram+data/data+electrocardiogram/us12651669-173-5-20
Average 86 stars, based on 1 article reviews
electrocardiogram data - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Physiodata Inc electrocardiogram ecg data
Electrocardiogram Ecg Data, supplied by Physiodata Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electrocardiogram+data/data+ecg+electrocardiogram/bio_rxiv__64898__2026__04__17__718894-221-0-7
Average 86 stars, based on 1 article reviews
electrocardiogram ecg data - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Kaggle Inc kaggle ecg data set
Kaggle Ecg Data Set, supplied by Kaggle Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electrocardiogram+data/categorization+dataset+ecg+heartbeat/10__1097_slash_coc__0000000000001280-25-0-0
Average 86 stars, based on 1 article reviews
kaggle ecg data set - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Fukuda Denshi Co mbf 1000 ecg data management system
(A) Representative <t>electrocardiogram</t> for determining PTFV1. PTFV1 (mm∙s) was calculated by the duration (s) of the terminal negative part of the P wave in lead V1 multiplied by the absolute value of its amplitude (mm). (B) Distribution of PTFV1 in patients with CAD who underwent PCI. The red bars indicate abnormal PTFV1, and the blue bars show normal PTFV1. CAD = coronary artery disease, PCI = percutaneous coronary intervention, and PTFV1 = P-wave terminal force in V1. (For interpretation of the references to colour in this figure legend, the reader is referred to the Web version of this article.)
Mbf 1000 Ecg Data Management System, supplied by Fukuda Denshi Co, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electrocardiogram+data/1000+analysis+bomeam+electrocardiograph+mbf+system/pmc12641559-82-8-13
Average 86 stars, based on 1 article reviews
mbf 1000 ecg data management system - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Biogen Inc ecg data
(A) Representative <t>electrocardiogram</t> for determining PTFV1. PTFV1 (mm∙s) was calculated by the duration (s) of the terminal negative part of the P wave in lead V1 multiplied by the absolute value of its amplitude (mm). (B) Distribution of PTFV1 in patients with CAD who underwent PCI. The red bars indicate abnormal PTFV1, and the blue bars show normal PTFV1. CAD = coronary artery disease, PCI = percutaneous coronary intervention, and PTFV1 = P-wave terminal force in V1. (For interpretation of the references to colour in this figure legend, the reader is referred to the Web version of this article.)
Ecg Data, supplied by Biogen Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electrocardiogram+data/data+ecg/fda_document____drugsatfda_docs_slash_nda_slash_2013_slash_204063orig1s000medr-1735-5-3
Average 86 stars, based on 1 article reviews
ecg data - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Pfizer Inc ecg monitoring data
(A) Representative <t>electrocardiogram</t> for determining PTFV1. PTFV1 (mm∙s) was calculated by the duration (s) of the terminal negative part of the P wave in lead V1 multiplied by the absolute value of its amplitude (mm). (B) Distribution of PTFV1 in patients with CAD who underwent PCI. The red bars indicate abnormal PTFV1, and the blue bars show normal PTFV1. CAD = coronary artery disease, PCI = percutaneous coronary intervention, and PTFV1 = P-wave terminal force in V1. (For interpretation of the references to colour in this figure legend, the reader is referred to the Web version of this article.)
Ecg Monitoring Data, supplied by Pfizer Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electrocardiogram+data/rsv+vaccine/fda_document____drugsatfda_docs_slash_nda_slash_2004_slash_021266orig1s009-623-4-16
Average 86 stars, based on 1 article reviews
ecg monitoring data - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Texas Instruments ecg data
(A) Representative <t>electrocardiogram</t> for determining PTFV1. PTFV1 (mm∙s) was calculated by the duration (s) of the terminal negative part of the P wave in lead V1 multiplied by the absolute value of its amplitude (mm). (B) Distribution of PTFV1 in patients with CAD who underwent PCI. The red bars indicate abnormal PTFV1, and the blue bars show normal PTFV1. CAD = coronary artery disease, PCI = percutaneous coronary intervention, and PTFV1 = P-wave terminal force in V1. (For interpretation of the references to colour in this figure legend, the reader is referred to the Web version of this article.)
Ecg Data, supplied by Texas Instruments, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electrocardiogram+data/data+ecg/pmc12484162-67-6-25
Average 86 stars, based on 1 article reviews
ecg data - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

96
ADInstruments electrocardiography ecg data
(A) Representative <t>electrocardiogram</t> for determining PTFV1. PTFV1 (mm∙s) was calculated by the duration (s) of the terminal negative part of the P wave in lead V1 multiplied by the absolute value of its amplitude (mm). (B) Distribution of PTFV1 in patients with CAD who underwent PCI. The red bars indicate abnormal PTFV1, and the blue bars show normal PTFV1. CAD = coronary artery disease, PCI = percutaneous coronary intervention, and PTFV1 = P-wave terminal force in V1. (For interpretation of the references to colour in this figure legend, the reader is referred to the Web version of this article.)
Electrocardiography Ecg Data, supplied by ADInstruments, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electrocardiogram+data/pm40108505-79-0-14
Average 96 stars, based on 1 article reviews
electrocardiography ecg data - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

86
Grafana Labs z ecg data visualization
(A) Representative <t>electrocardiogram</t> for determining PTFV1. PTFV1 (mm∙s) was calculated by the duration (s) of the terminal negative part of the P wave in lead V1 multiplied by the absolute value of its amplitude (mm). (B) Distribution of PTFV1 in patients with CAD who underwent PCI. The red bars indicate abnormal PTFV1, and the blue bars show normal PTFV1. CAD = coronary artery disease, PCI = percutaneous coronary intervention, and PTFV1 = P-wave terminal force in V1. (For interpretation of the references to colour in this figure legend, the reader is referred to the Web version of this article.)
Z Ecg Data Visualization, supplied by Grafana Labs, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electrocardiogram+data/data+grafana+software+visualization/10__3390_slash_info16030213-747-3-11
Average 86 stars, based on 1 article reviews
z ecg data visualization - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

Image Search Results


(A) Representative electrocardiogram for determining PTFV1. PTFV1 (mm∙s) was calculated by the duration (s) of the terminal negative part of the P wave in lead V1 multiplied by the absolute value of its amplitude (mm). (B) Distribution of PTFV1 in patients with CAD who underwent PCI. The red bars indicate abnormal PTFV1, and the blue bars show normal PTFV1. CAD = coronary artery disease, PCI = percutaneous coronary intervention, and PTFV1 = P-wave terminal force in V1. (For interpretation of the references to colour in this figure legend, the reader is referred to the Web version of this article.)

Journal: International Journal of Cardiology. Cardiovascular Risk and Prevention

Article Title: Prevalence, associated factors, and prognostic value of P wave abnormality in patients with coronary artery disease

doi: 10.1016/j.ijcrp.2025.200533

Figure Lengend Snippet: (A) Representative electrocardiogram for determining PTFV1. PTFV1 (mm∙s) was calculated by the duration (s) of the terminal negative part of the P wave in lead V1 multiplied by the absolute value of its amplitude (mm). (B) Distribution of PTFV1 in patients with CAD who underwent PCI. The red bars indicate abnormal PTFV1, and the blue bars show normal PTFV1. CAD = coronary artery disease, PCI = percutaneous coronary intervention, and PTFV1 = P-wave terminal force in V1. (For interpretation of the references to colour in this figure legend, the reader is referred to the Web version of this article.)

Article Snippet: These parameters were also automatically analyzed by the MBF-1000 ECG Data Management System (Fukuda Denshi Co., Ltd., Tokyo, Japan) in 1179 patients.

Techniques: