Review




Structured Review

Philips Healthcare imaging software echonavigator
Imaging Software Echonavigator, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/echonavigator+software/echonavigator+software/pmc09724844-359-2-5
Average 90 stars, based on 1 article reviews
imaging software echonavigator - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

other:

Article Title: Echocardiographic-fluoroscopic fusion imaging with the mini 3D transesophageal probe in pediatric congenital heart disease.
Article Snippet: Echocardiography-fluoroscopy fusion (EFF) imaging was introduced several years ago to improve guidance during interventional procedures in adult patients.. While limited studies have focused on its use in children with congenital heart disease (CHD), they were constrained by the availability of 3-dimensional (3D) probes designed for adults.. The recent development of mini 3D transesophageal echocardiography (3D-TEE) probes has expanded the utility of this technology to smaller patients, including those weighing less than 30 kg.

Article Title: Fusion imaging during balloon mitral valvulopasty: First experience.
Article Snippet: A 35-year-old male with a history of obstructive sleep apnea and obesity presented for evaluation of dyspnea and new onset of paroxysmal atrial fibrillation secondary to rheumatic mitral stenosis (MS).. A transthoracic echocardiogram (TTE) demonstrated a left ventricular ejection fraction of 45% and rheumatic mitral valve changes.. A three-dimensional (3D) TEE revealed a mitral valve area (MVA) of 1.5 cm2, based on 3D planimetry, and a mean gradient of 7 mm Hg at a heart rate of 112 beats per minute.

Article Title: Fusion imaging in interventional cardiology.
Article Snippet: All these limitations can be solved by fluoroscopy.2,4,3 These two images are routinely obtained independently and displayed on different screens in different orientations, which requires the information to be integrated and mentally reconstructed by the operators.3,11 In 2014, the second version of the EchoNavigator® software (Philips Healthcare, Best, The Netherlands) was developed, which enables TEE to be fused with the fluoroscopy imaging on the same screen.2,12 Once the TEE ultrasound has been automatically co-registered, repositioning the C-arm allows the fluoroscopic and echocardiographic images to move in sync, without loss of imaging fusion.1,4,10,3 The co-registration process uses a calibration algorithm between the TEE ultrasound and the fluoroscopy for the system to identify the ultrasound probe and generate an overlay image with the two modalities orientated in the same direction.5 This is automatic and fairly accurate (the average error is one to two milimeters),11 and can be optimized by placing the TEE probe in the center of the fluoroscopy image screen, at the following angles: 0◦, 45◦ left anterior oblique and 45◦ right anterior oblique.11 Once v t f n 465 egistration is complete, all changes to the TEE probe (posiion, rotation and angulation) are automatically detected y the system and the image is updated on the screen, ogether with the fluoroscopy.

Software:

Article Title: New horizon of fusion imaging using echocardiography: its progress in the diagnosis and treatment of cardiovascular disease.
Article Snippet: Cardiac imaging modalities are essential for the management of cardiac diseases.. Multimodality imaging, such as echocardiography, cardiac computed tomography (CT), cardiac magnetic resonance imaging, and fluoroscopy, is required for assessing cardiac condition.. In recent years, fusion imaging, which integrates different imaging modalities on the same screen, has been developed.

Article Title: Transseptal puncture: procedural guidance, challenging situations and management of complications
Article Snippet: .. A novel imaging software (EchoNavigator; Philips Healthcare, Best, the Netherlands) allows the integration between fluoroscopic and TEE images: it acquires patient-specific imaging data from both fluoroscopic projections and bi-/tri-dimensional TEE volumetric data sets and finally overlaps them. ..

Article Title: Advances in TEE-Centric Intraprocedural Multimodal Image Guidance for Congenital and Structural Heart Disease.
Article Snippet: .. The EchoNavigator software (Philips Healthcare, Best, The Netherlands) performs real-time 3D TEE and fluoroscopy fusion on a single screen. ..

Article Title: Transseptal puncture: procedural guidance, challenging situations and management of complications
Article Snippet: .. THE ROLE OF REAL-TIME FUSION IMAGING A novel imaging software (EchoNavigator; Philips Healthcare, Best, the Netherlands) allows the integration between fluoroscopic and TEE images: it acquires patient-specific imaging data from both fluoroscopic projections and bi-/tri-dimensional TEE volumetric data sets and finally overlaps them. ..

Article Title: Digital health in cardiovascular medicine: An overview of key applications and clinical impact by the Portuguese Society of Cardiology Study Group on Digital Health.
Article Snippet: .. The bestknown example is probably the EchoNavigator® (Philips, The Netherlands) software that fuses fluoroscopy and echocardiography images to enhance the perception of the position of the catheters and devices being deployed relative to the surrounding heart structures.75 2.3 Natural language processing and chatbots Electronic health records are increasingly recognized as a powerful tool to enhance the quality of medical care and clinical research.76 However, a significant portion of EHR involves free text that is not readily accessible for data abstraction and the intricate nature of plain language makes conventional rule-based methods prone to misclassification and bias.77 Deep learning-based natural language processing (NLP) models are emerging as more dependable alternatives to interrogate large volumes of free text and leverage its’ data for predictive analytics78, patient identification/recruitment,79 among others. ..

Imaging:

Article Title: Transseptal puncture: procedural guidance, challenging situations and management of complications
Article Snippet: .. A novel imaging software (EchoNavigator; Philips Healthcare, Best, the Netherlands) allows the integration between fluoroscopic and TEE images: it acquires patient-specific imaging data from both fluoroscopic projections and bi-/tri-dimensional TEE volumetric data sets and finally overlaps them. ..

Article Title: Transseptal puncture: procedural guidance, challenging situations and management of complications
Article Snippet: .. THE ROLE OF REAL-TIME FUSION IMAGING A novel imaging software (EchoNavigator; Philips Healthcare, Best, the Netherlands) allows the integration between fluoroscopic and TEE images: it acquires patient-specific imaging data from both fluoroscopic projections and bi-/tri-dimensional TEE volumetric data sets and finally overlaps them. ..



Similar Products

90
Philips Healthcare echonavigator software v4.0
Echonavigator Software V4.0, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/echonavigator+software/echonavigator+software/pm40221086-8-0-3
Average 90 stars, based on 1 article reviews
echonavigator software v4.0 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Philips Healthcare echonavigator® software
Echonavigator® Software, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/echonavigator+software/echonavigator+software/pm39393635-55-6-7
Average 90 stars, based on 1 article reviews
echonavigator® software - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Philips Healthcare echonavigator software
Echonavigator Software, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/echonavigator+software/echonavigator+software/pm37761348-428-1-3
Average 90 stars, based on 1 article reviews
echonavigator software - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Philips Healthcare fluoroscopic fusion software (echonavigator release 3.0
Fluoroscopic Fusion Software (Echonavigator Release 3.0, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/echonavigator+software/fluoroscopic+fusion+software++echonavigator+release+3+0/pm35643764-10-7-13
Average 90 stars, based on 1 article reviews
fluoroscopic fusion software (echonavigator release 3.0 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Philips Healthcare 3d transesophageal echocardiography (tee) and fluoroscopic fusion software echonavigator release 3.0
3d Transesophageal Echocardiography (Tee) And Fluoroscopic Fusion Software Echonavigator Release 3.0, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/echonavigator+software/sonos+7500/pm35643764-2-7-13
Average 90 stars, based on 1 article reviews
3d transesophageal echocardiography (tee) and fluoroscopic fusion software echonavigator release 3.0 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Philips Healthcare echonavigator transesophageal echocardiographic-fluoroscopic fusion imaging software
<t>EchoNavigator</t> virtual marker and fusion imaging for transcatheter closure of paravalvular leak. A: Significant mitral paravalvular leak (PVL) was seen in <t>transesophageal</t> echocardiography (TEE 0 degrees); B: The PVL location at the X-plane views of TEE was marked to generate marker 1 on the fluoroscopic screen; C: A suitable point for transseptal puncture was made under the guidance of TEE; D: The curvature of the Agilis NxT steerable introducer was adjusted for better orientation; E: The PVL defect was crossed with a 0.035-inch guidewire supported by the telescoping system of a 6 Fr MP guide catheter and JR4 diagnostic catheter; F: Three-dimensional TEE showed the first Amplatzer Vascular Plug II (AVP II 12 mm); G: The second AVP II (10 mm) was deployed without releasing the first AVP II; H: The second AVP II (10 mm) was released first; I: Color Doppler mode of the TEE showed only mild residual PVL; J: Three-dimensional TEE showed that the 1st AVP II (12 mm) had been released; K: Final position of the two AVP II (blue arrow heads).
Echonavigator Transesophageal Echocardiographic Fluoroscopic Fusion Imaging Software, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/echonavigator+software/echonavigator+transesophageal+echocardiographic+fluoroscopic+fusion+imaging+software/pmc09131240-27-0-6
Average 90 stars, based on 1 article reviews
echonavigator transesophageal echocardiographic-fluoroscopic fusion imaging software - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Philips Healthcare echonavigator echocardiographic-fluoroscopic fusion imaging software second release software
( A ) Baseline 3D TEE color Doppler showing two round-shaped mitral PVLs with significant regurgitant jets located at 5 o’clock (3.2 mm) and 7 o’clock (3.6 mm) ( a , b ) in a female patient with a mitral bioprosthetic valve replacement; ( c ): successful implantation of a 3 mm-square twist PLD (red asterisk) at 5 o’clock; ( d ): fusion of real-time 2D TEE (Phillips Epiq7) and cardiac fluoroscopy imaging was obtained using <t>EchoNavigator®-system</t> (Philips Healthcare, Best, The Netherlands) with the fused image maintained demonstrating the location of the postero-laterally located (7 o’clock) mitral PVL (yellow circle) that was marked to aid the pathway of the guidewire (black arrow) crossing the leak, particularly in the case of a radiolucent bioprosthetic valve like in our patient. “ * ” refers to 3 mm-square twist PLD. ( B ) Intraprocedural navigation using fusion of 3D TEE and fluoroscopy with the fused image maintained helped the interventionalist to close successfully the second leak with a 5 mm-square twist PLD (black asterisk), improving the safety and the efficacy of this technically challenging procedure. PLD, Occlutech Paravalvular Leak Device ST, square twist, “ * ” refers to 5 mm-square twist PLD.
Echonavigator Echocardiographic Fluoroscopic Fusion Imaging Software Second Release Software, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/echonavigator+software/echonavigator+echocardiographic+fluoroscopic+fusion+imaging+software+second+release+software/pmc08999580-73-15-23
Average 90 stars, based on 1 article reviews
echonavigator echocardiographic-fluoroscopic fusion imaging software second release software - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Philips Healthcare imaging software echonavigator
( A ) Baseline 3D TEE color Doppler showing two round-shaped mitral PVLs with significant regurgitant jets located at 5 o’clock (3.2 mm) and 7 o’clock (3.6 mm) ( a , b ) in a female patient with a mitral bioprosthetic valve replacement; ( c ): successful implantation of a 3 mm-square twist PLD (red asterisk) at 5 o’clock; ( d ): fusion of real-time 2D TEE (Phillips Epiq7) and cardiac fluoroscopy imaging was obtained using <t>EchoNavigator®-system</t> (Philips Healthcare, Best, The Netherlands) with the fused image maintained demonstrating the location of the postero-laterally located (7 o’clock) mitral PVL (yellow circle) that was marked to aid the pathway of the guidewire (black arrow) crossing the leak, particularly in the case of a radiolucent bioprosthetic valve like in our patient. “ * ” refers to 3 mm-square twist PLD. ( B ) Intraprocedural navigation using fusion of 3D TEE and fluoroscopy with the fused image maintained helped the interventionalist to close successfully the second leak with a 5 mm-square twist PLD (black asterisk), improving the safety and the efficacy of this technically challenging procedure. PLD, Occlutech Paravalvular Leak Device ST, square twist, “ * ” refers to 5 mm-square twist PLD.
Imaging Software Echonavigator, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/echonavigator+software/echonavigator+software/pmc09724844-359-2-5
Average 90 stars, based on 1 article reviews
imaging software echonavigator - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


EchoNavigator virtual marker and fusion imaging for transcatheter closure of paravalvular leak. A: Significant mitral paravalvular leak (PVL) was seen in transesophageal echocardiography (TEE 0 degrees); B: The PVL location at the X-plane views of TEE was marked to generate marker 1 on the fluoroscopic screen; C: A suitable point for transseptal puncture was made under the guidance of TEE; D: The curvature of the Agilis NxT steerable introducer was adjusted for better orientation; E: The PVL defect was crossed with a 0.035-inch guidewire supported by the telescoping system of a 6 Fr MP guide catheter and JR4 diagnostic catheter; F: Three-dimensional TEE showed the first Amplatzer Vascular Plug II (AVP II 12 mm); G: The second AVP II (10 mm) was deployed without releasing the first AVP II; H: The second AVP II (10 mm) was released first; I: Color Doppler mode of the TEE showed only mild residual PVL; J: Three-dimensional TEE showed that the 1st AVP II (12 mm) had been released; K: Final position of the two AVP II (blue arrow heads).

Journal: World Journal of Clinical Cases

Article Title: EchoNavigator virtual marker and Agilis NxT steerable introducer facilitate transseptal transcatheter closure of mitral paravalvular leak

doi: 10.12998/wjcc.v10.i13.4236

Figure Lengend Snippet: EchoNavigator virtual marker and fusion imaging for transcatheter closure of paravalvular leak. A: Significant mitral paravalvular leak (PVL) was seen in transesophageal echocardiography (TEE 0 degrees); B: The PVL location at the X-plane views of TEE was marked to generate marker 1 on the fluoroscopic screen; C: A suitable point for transseptal puncture was made under the guidance of TEE; D: The curvature of the Agilis NxT steerable introducer was adjusted for better orientation; E: The PVL defect was crossed with a 0.035-inch guidewire supported by the telescoping system of a 6 Fr MP guide catheter and JR4 diagnostic catheter; F: Three-dimensional TEE showed the first Amplatzer Vascular Plug II (AVP II 12 mm); G: The second AVP II (10 mm) was deployed without releasing the first AVP II; H: The second AVP II (10 mm) was released first; I: Color Doppler mode of the TEE showed only mild residual PVL; J: Three-dimensional TEE showed that the 1st AVP II (12 mm) had been released; K: Final position of the two AVP II (blue arrow heads).

Article Snippet: EchoNavigator transesophageal echocardiographic-fluoroscopic fusion imaging software (Philips Medical Systems, Best, the Netherlands) was used during the procedure (Figure ).

Techniques: Marker, Imaging, Diagnostic Assay

( A ) Baseline 3D TEE color Doppler showing two round-shaped mitral PVLs with significant regurgitant jets located at 5 o’clock (3.2 mm) and 7 o’clock (3.6 mm) ( a , b ) in a female patient with a mitral bioprosthetic valve replacement; ( c ): successful implantation of a 3 mm-square twist PLD (red asterisk) at 5 o’clock; ( d ): fusion of real-time 2D TEE (Phillips Epiq7) and cardiac fluoroscopy imaging was obtained using EchoNavigator®-system (Philips Healthcare, Best, The Netherlands) with the fused image maintained demonstrating the location of the postero-laterally located (7 o’clock) mitral PVL (yellow circle) that was marked to aid the pathway of the guidewire (black arrow) crossing the leak, particularly in the case of a radiolucent bioprosthetic valve like in our patient. “ * ” refers to 3 mm-square twist PLD. ( B ) Intraprocedural navigation using fusion of 3D TEE and fluoroscopy with the fused image maintained helped the interventionalist to close successfully the second leak with a 5 mm-square twist PLD (black asterisk), improving the safety and the efficacy of this technically challenging procedure. PLD, Occlutech Paravalvular Leak Device ST, square twist, “ * ” refers to 5 mm-square twist PLD.

Journal: Journal of Clinical Medicine

Article Title: Safety, Efficacy and Long-Term Outcomes of Patients Treated with the Occlutech Paravalvular Leak Device for Significant Paravalvular Regurgitation

doi: 10.3390/jcm11071978

Figure Lengend Snippet: ( A ) Baseline 3D TEE color Doppler showing two round-shaped mitral PVLs with significant regurgitant jets located at 5 o’clock (3.2 mm) and 7 o’clock (3.6 mm) ( a , b ) in a female patient with a mitral bioprosthetic valve replacement; ( c ): successful implantation of a 3 mm-square twist PLD (red asterisk) at 5 o’clock; ( d ): fusion of real-time 2D TEE (Phillips Epiq7) and cardiac fluoroscopy imaging was obtained using EchoNavigator®-system (Philips Healthcare, Best, The Netherlands) with the fused image maintained demonstrating the location of the postero-laterally located (7 o’clock) mitral PVL (yellow circle) that was marked to aid the pathway of the guidewire (black arrow) crossing the leak, particularly in the case of a radiolucent bioprosthetic valve like in our patient. “ * ” refers to 3 mm-square twist PLD. ( B ) Intraprocedural navigation using fusion of 3D TEE and fluoroscopy with the fused image maintained helped the interventionalist to close successfully the second leak with a 5 mm-square twist PLD (black asterisk), improving the safety and the efficacy of this technically challenging procedure. PLD, Occlutech Paravalvular Leak Device ST, square twist, “ * ” refers to 5 mm-square twist PLD.

Article Snippet: In a subset of patients with Mi PVLs, the transapical hybrid approach was applied using EchoNavigator echocardiographic-fluoroscopic fusion imaging software (second release software, Philips Medical Systems, Best, The Netherlands).

Techniques: Imaging