Review




Structured Review

Siemens Healthineers body diffusion toolbox
Body Diffusion Toolbox, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/diffusion+analysis+toolbox+(dmat/body+diffusion+toolbox/pm36064445-75-6-9
Average 90 stars, based on 1 article reviews
body diffusion toolbox - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

Software:

Article Title: Predicting disease-free survival in locally advanced rectal cancer using a prognostic model based on pretreatment b-value threshold map and postoperative pathologic features.
Article Snippet: Purpose Disease-free survival (DFS) after neoadjuvant chemoradiotherapy (nCRT) is an important factor in affecting the quality of life and determining the subsequent treatment procedures for patients with locally advanced rectal cancer (LARC).. This study aimed to develop a novel prognostic model for predicting the DFS in patients with LARC following nCRT and to verify its effectiveness.. Materials and methods Patients with LARC who underwent magnetic resonance imaging (MRI) and nCRT at our institution between November 2017 and March 2022 were enrolled in this retrospective study.

Article Title: Breast Cancer: Habitat imaging based on intravoxel incoherent motion for predicting pathologic complete response to neoadjuvant chemotherapy.
Article Snippet: .. To obtain IVIM maps, we carried out a pixel-by-pixel fitting of the diffusion-weighted imaging data by using the prototype research software Body Diffusion Toolbox (Siemens Healthcare, Erlangen, Germany). ..

Article Title: Combined morphology and radiomics of intravoxel incoherent movement as a predictive model for the pathologic complete response before neoadjuvant chemotherapy in patients with breast cancer
Article Snippet: .. To obtain IVIM maps, a pixel-by-pixel fitting of DWI data was carried out using a research prototype software called Body Diffusion Toolbox (Siemens Healthcare, Erlangen, Germany). ..

Article Title: Multitask deep learning model based on multimodal data for predicting prognosis of rectal cancer: a multicenter retrospective study
Article Snippet: .. From diffusion weighted images with multi-b values, DKI model derived corrected diffusion coefficient (D app ), diffusion kurtosis coefficient (K app ) and conventional diffusion weighted imaging (DWI) derived apparent diffusion coefficient (ADC) were calculated by using the research application post-processing software Body Diffusion Toolbox (Siemens Healthineers, Erlangen, Germany). ..

Article Title: Breast Cancer: Habitat imaging based on intravoxel incoherent motion for predicting pathologic complete response to neoadjuvant chemotherapy
Article Snippet: .. To obtain IVIM maps, we carried out a pixel‐by‐pixel fitting of the diffusion‐weighted imaging data by using the prototype research software Body Diffusion Toolbox (Siemens Healthcare, Erlangen, Germany). ..

Diffusion-based Assay:

Article Title: Predicting disease-free survival in locally advanced rectal cancer using a prognostic model based on pretreatment b-value threshold map and postoperative pathologic features.
Article Snippet: Purpose Disease-free survival (DFS) after neoadjuvant chemoradiotherapy (nCRT) is an important factor in affecting the quality of life and determining the subsequent treatment procedures for patients with locally advanced rectal cancer (LARC).. This study aimed to develop a novel prognostic model for predicting the DFS in patients with LARC following nCRT and to verify its effectiveness.. Materials and methods Patients with LARC who underwent magnetic resonance imaging (MRI) and nCRT at our institution between November 2017 and March 2022 were enrolled in this retrospective study.

Article Title: Breast Cancer: Habitat imaging based on intravoxel incoherent motion for predicting pathologic complete response to neoadjuvant chemotherapy.
Article Snippet: .. To obtain IVIM maps, we carried out a pixel-by-pixel fitting of the diffusion-weighted imaging data by using the prototype research software Body Diffusion Toolbox (Siemens Healthcare, Erlangen, Germany). ..

Article Title: Combined morphology and radiomics of intravoxel incoherent movement as a predictive model for the pathologic complete response before neoadjuvant chemotherapy in patients with breast cancer
Article Snippet: .. To obtain IVIM maps, a pixel-by-pixel fitting of DWI data was carried out using a research prototype software called Body Diffusion Toolbox (Siemens Healthcare, Erlangen, Germany). ..

Article Title: Distinguishing Low Expression Levels of Human Epidermal Growth Factor Receptor 2 in Breast Cancer: Insights from Qualitative and Quantitative Magnetic Resonance Imaging Analysis.
Article Snippet: .. Quantitative MRI Analysis Quantitative analysis included conventional apparent diffusion coefficient (ADC) values derived from the mono-exponential model, as well as Dapp and Kapp values from the DKI model. All DKI images were processed using a workstation (Body Diffusion Toolbox, version 0.2.2, Siemens Healthcare). ..

Article Title: Distinguishing Low Expression Levels of Human Epidermal Growth Factor Receptor 2 in Breast Cancer: Insights from Qualitative and Quantitative Magnetic Resonance Imaging Analysis
Article Snippet: .. Quantitative analysis included conventional apparent diffusion coefficient (ADC) values derived from the mono-exponential model, as well as D a p p and K a p p values from the DKI model. All DKI images were processed using a workstation (Body Diffusion Toolbox, version 0.2.2, Siemens Healthcare). ..

Article Title: Multitask deep learning model based on multimodal data for predicting prognosis of rectal cancer: a multicenter retrospective study
Article Snippet: .. From diffusion weighted images with multi-b values, DKI model derived corrected diffusion coefficient (D app ), diffusion kurtosis coefficient (K app ) and conventional diffusion weighted imaging (DWI) derived apparent diffusion coefficient (ADC) were calculated by using the research application post-processing software Body Diffusion Toolbox (Siemens Healthineers, Erlangen, Germany). ..

Article Title: Breast Cancer: Habitat imaging based on intravoxel incoherent motion for predicting pathologic complete response to neoadjuvant chemotherapy
Article Snippet: .. To obtain IVIM maps, we carried out a pixel‐by‐pixel fitting of the diffusion‐weighted imaging data by using the prototype research software Body Diffusion Toolbox (Siemens Healthcare, Erlangen, Germany). ..

other:

Article Title: ZOOMit diffusion kurtosis imaging combined with diffusion weighted imaging for the assessment of microsatellite instability in endometrial cancer.
Article Snippet: 1 Tianjin Medical University Cancer Institute and Hospital, Tianjin, China 2 Xuzhou Maternity and Child Health Care Hospital, Xvzhou, China 3 Siemens Healthcare, Beijing, China Abstract Purpose Detecting microsatellite instability (MSI) plays a key role in the management of endometrial cancer (EC), as it is a critical predictive biomarker for Lynch syndrome or immunotherapy response.. A pressing need exists for cost-efficient, broadly accessible tools to aid patient for universal testing.. Herein, we investigate the value of ZOOMit diffusion kurtosis imaging (DKI) and diffusion weighted imaging (DWI) based on preoperative pelvic magnetic resonance imaging (MRI) images in assessing MSI in EC.

Imaging:

Article Title: Breast Cancer: Habitat imaging based on intravoxel incoherent motion for predicting pathologic complete response to neoadjuvant chemotherapy.
Article Snippet: .. To obtain IVIM maps, we carried out a pixel-by-pixel fitting of the diffusion-weighted imaging data by using the prototype research software Body Diffusion Toolbox (Siemens Healthcare, Erlangen, Germany). ..

Article Title: Multitask deep learning model based on multimodal data for predicting prognosis of rectal cancer: a multicenter retrospective study
Article Snippet: .. From diffusion weighted images with multi-b values, DKI model derived corrected diffusion coefficient (D app ), diffusion kurtosis coefficient (K app ) and conventional diffusion weighted imaging (DWI) derived apparent diffusion coefficient (ADC) were calculated by using the research application post-processing software Body Diffusion Toolbox (Siemens Healthineers, Erlangen, Germany). ..

Article Title: Breast Cancer: Habitat imaging based on intravoxel incoherent motion for predicting pathologic complete response to neoadjuvant chemotherapy
Article Snippet: .. To obtain IVIM maps, we carried out a pixel‐by‐pixel fitting of the diffusion‐weighted imaging data by using the prototype research software Body Diffusion Toolbox (Siemens Healthcare, Erlangen, Germany). ..

Magnetic Resonance Imaging:

Article Title: Distinguishing Low Expression Levels of Human Epidermal Growth Factor Receptor 2 in Breast Cancer: Insights from Qualitative and Quantitative Magnetic Resonance Imaging Analysis.
Article Snippet: .. Quantitative MRI Analysis Quantitative analysis included conventional apparent diffusion coefficient (ADC) values derived from the mono-exponential model, as well as Dapp and Kapp values from the DKI model. All DKI images were processed using a workstation (Body Diffusion Toolbox, version 0.2.2, Siemens Healthcare). ..

Derivative Assay:

Article Title: Distinguishing Low Expression Levels of Human Epidermal Growth Factor Receptor 2 in Breast Cancer: Insights from Qualitative and Quantitative Magnetic Resonance Imaging Analysis.
Article Snippet: .. Quantitative MRI Analysis Quantitative analysis included conventional apparent diffusion coefficient (ADC) values derived from the mono-exponential model, as well as Dapp and Kapp values from the DKI model. All DKI images were processed using a workstation (Body Diffusion Toolbox, version 0.2.2, Siemens Healthcare). ..

Article Title: Distinguishing Low Expression Levels of Human Epidermal Growth Factor Receptor 2 in Breast Cancer: Insights from Qualitative and Quantitative Magnetic Resonance Imaging Analysis
Article Snippet: .. Quantitative analysis included conventional apparent diffusion coefficient (ADC) values derived from the mono-exponential model, as well as D a p p and K a p p values from the DKI model. All DKI images were processed using a workstation (Body Diffusion Toolbox, version 0.2.2, Siemens Healthcare). ..

Article Title: Multitask deep learning model based on multimodal data for predicting prognosis of rectal cancer: a multicenter retrospective study
Article Snippet: .. From diffusion weighted images with multi-b values, DKI model derived corrected diffusion coefficient (D app ), diffusion kurtosis coefficient (K app ) and conventional diffusion weighted imaging (DWI) derived apparent diffusion coefficient (ADC) were calculated by using the research application post-processing software Body Diffusion Toolbox (Siemens Healthineers, Erlangen, Germany). ..



Similar Products

90
MathWorks Inc diffusion model analysis toolbox (dmat) in
<t>DMAT</t> model fits. We fit <t>the</t> <t>diffusion</t> model to the data using the software package DMAT by allowing only the boundary parameter to vary with SAT levels and the drift parameter to vary with contrast. The fits were very similar to the ones with HDDM (Fig. ). We observed good fits for the d′-RT curves except for the “extremely fast” condition (upper left panel), monotonically increasing functions for the RT difference between error and correct trials (upper right panel), monotonically increasing \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\frac{{SD\left( {RT} \right)}}{{mean\left( {RT} \right)}}$$\end{document} S D RT m e a n RT curves (lower left panel), and inverted-U RT skewness curves (lower right panel). Again, none of the empirically observed U-shaped curves were reproduced even qualitatively. All notation is identical to Fig. .
Diffusion Model Analysis Toolbox (Dmat) In, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/diffusion+analysis+toolbox+(dmat/pmc07794484-427-20-26
Average 90 stars, based on 1 article reviews
diffusion model analysis toolbox (dmat) in - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
MathWorks Inc diffusion analysis toolbox (dmat
<t>DMAT</t> model fits. We fit <t>the</t> <t>diffusion</t> model to the data using the software package DMAT by allowing only the boundary parameter to vary with SAT levels and the drift parameter to vary with contrast. The fits were very similar to the ones with HDDM (Fig. ). We observed good fits for the d′-RT curves except for the “extremely fast” condition (upper left panel), monotonically increasing functions for the RT difference between error and correct trials (upper right panel), monotonically increasing \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\frac{{SD\left( {RT} \right)}}{{mean\left( {RT} \right)}}$$\end{document} S D RT m e a n RT curves (lower left panel), and inverted-U RT skewness curves (lower right panel). Again, none of the empirically observed U-shaped curves were reproduced even qualitatively. All notation is identical to Fig. .
Diffusion Analysis Toolbox (Dmat, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/diffusion+analysis+toolbox+(dmat/diffusion+analysis+toolbox/pmc06377450-240-15-12
Average 90 stars, based on 1 article reviews
diffusion analysis toolbox (dmat - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
MathWorks Inc diffusion model analysis toolbox dmat
<t>DMAT</t> model fits. We fit <t>the</t> <t>diffusion</t> model to the data using the software package DMAT by allowing only the boundary parameter to vary with SAT levels and the drift parameter to vary with contrast. The fits were very similar to the ones with HDDM (Fig. ). We observed good fits for the d′-RT curves except for the “extremely fast” condition (upper left panel), monotonically increasing functions for the RT difference between error and correct trials (upper right panel), monotonically increasing \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\frac{{SD\left( {RT} \right)}}{{mean\left( {RT} \right)}}$$\end{document} S D RT m e a n RT curves (lower left panel), and inverted-U RT skewness curves (lower right panel). Again, none of the empirically observed U-shaped curves were reproduced even qualitatively. All notation is identical to Fig. .
Diffusion Model Analysis Toolbox Dmat, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/diffusion+analysis+toolbox+(dmat/pmc04534506-121-1-12
Average 90 stars, based on 1 article reviews
diffusion model analysis toolbox dmat - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
MathWorks Inc diffusion model analysis toolbox (dmat)
<t>DMAT</t> model fits. We fit <t>the</t> <t>diffusion</t> model to the data using the software package DMAT by allowing only the boundary parameter to vary with SAT levels and the drift parameter to vary with contrast. The fits were very similar to the ones with HDDM (Fig. ). We observed good fits for the d′-RT curves except for the “extremely fast” condition (upper left panel), monotonically increasing functions for the RT difference between error and correct trials (upper right panel), monotonically increasing \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\frac{{SD\left( {RT} \right)}}{{mean\left( {RT} \right)}}$$\end{document} S D RT m e a n RT curves (lower left panel), and inverted-U RT skewness curves (lower right panel). Again, none of the empirically observed U-shaped curves were reproduced even qualitatively. All notation is identical to Fig. .
Diffusion Model Analysis Toolbox (Dmat), supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/diffusion+analysis+toolbox+(dmat/pmc03383845-342-21-27
Average 90 stars, based on 1 article reviews
diffusion model analysis toolbox (dmat) - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
MathWorks Inc diffusion model analysis toolbox (dmat) software
<t>DMAT</t> model fits. We fit <t>the</t> <t>diffusion</t> model to the data using the software package DMAT by allowing only the boundary parameter to vary with SAT levels and the drift parameter to vary with contrast. The fits were very similar to the ones with HDDM (Fig. ). We observed good fits for the d′-RT curves except for the “extremely fast” condition (upper left panel), monotonically increasing functions for the RT difference between error and correct trials (upper right panel), monotonically increasing \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\frac{{SD\left( {RT} \right)}}{{mean\left( {RT} \right)}}$$\end{document} S D RT m e a n RT curves (lower left panel), and inverted-U RT skewness curves (lower right panel). Again, none of the empirically observed U-shaped curves were reproduced even qualitatively. All notation is identical to Fig. .
Diffusion Model Analysis Toolbox (Dmat) Software, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/diffusion+analysis+toolbox+(dmat/pmc02791916-1123-15-12
Average 90 stars, based on 1 article reviews
diffusion model analysis toolbox (dmat) software - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


DMAT model fits. We fit the diffusion model to the data using the software package DMAT by allowing only the boundary parameter to vary with SAT levels and the drift parameter to vary with contrast. The fits were very similar to the ones with HDDM (Fig. ). We observed good fits for the d′-RT curves except for the “extremely fast” condition (upper left panel), monotonically increasing functions for the RT difference between error and correct trials (upper right panel), monotonically increasing \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\frac{{SD\left( {RT} \right)}}{{mean\left( {RT} \right)}}$$\end{document} S D RT m e a n RT curves (lower left panel), and inverted-U RT skewness curves (lower right panel). Again, none of the empirically observed U-shaped curves were reproduced even qualitatively. All notation is identical to Fig. .

Journal: Scientific Reports

Article Title: Qualitative speed-accuracy tradeoff effects that cannot be explained by the diffusion model under the selective influence assumption

doi: 10.1038/s41598-020-79765-2

Figure Lengend Snippet: DMAT model fits. We fit the diffusion model to the data using the software package DMAT by allowing only the boundary parameter to vary with SAT levels and the drift parameter to vary with contrast. The fits were very similar to the ones with HDDM (Fig. ). We observed good fits for the d′-RT curves except for the “extremely fast” condition (upper left panel), monotonically increasing functions for the RT difference between error and correct trials (upper right panel), monotonically increasing \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\frac{{SD\left( {RT} \right)}}{{mean\left( {RT} \right)}}$$\end{document} S D RT m e a n RT curves (lower left panel), and inverted-U RT skewness curves (lower right panel). Again, none of the empirically observed U-shaped curves were reproduced even qualitatively. All notation is identical to Fig. .

Article Snippet: We fit the diffusion model to the data using both the hierarchical drift diffusion model (HDDM) python package and the diffusion model analysis toolbox (DMAT) in MATLAB .

Techniques: Diffusion-based Assay, Software