Dexcom Inc enlite sensor
Table 4.
Enlite Sensor, supplied by Dexcom Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dexcom+sensor/enlite+sensor/pmc04201312-182-9-1
Average 90 stars, based on 1 article reviews
enlite sensor - by Bioz Stars, 2026-11
90/100 stars

Images

1) Product Images from "A Clinical Trial of the Accuracy and Treatment Experience of the Dexcom G4 Sensor (Dexcom G4 System) and Enlite Sensor (Guardian REAL-Time System) Tested Simultaneously in Ambulatory Patients with Type 1 Diabetes"

Article Title: A Clinical Trial of the Accuracy and Treatment Experience of the Dexcom G4 Sensor (Dexcom G4 System) and Enlite Sensor (Guardian REAL-Time System) Tested Simultaneously in Ambulatory Patients with Type 1 Diabetes

Journal: Diabetes Technology & Therapeutics

doi: 10.1089/dia.2014.0238

Table 4.
Figure Legend Snippet: Table 4.

Techniques Used:

Related Articles

Modification:

Article Title: Allergic contact dermatitis caused by glucose sensors and insulin pumps: A full review
Article Snippet: Colophonium‐related substances, including hydrogenated resin acids and derivatives have been found in the Dexcom G7 sensor. .. ACD from (modified) colophonium has been most frequently observed with the Enlite sensor ( n = 20): a case series of (a maximum of) 6 patients, a series of 5, a series of 4 and 5 single case reports., , , , There are 3 single case reports of ACD from colophonium in the Omnipod pump, , , 2 patients with ACD from modified colophonium in the FSL sensor and in the Dexcom G7 sensor and one case report each of TouchCare A6 and Omnipod DASH. ..

Article Title: Allergic contact dermatitis caused by glucose sensors and insulin pumps: A full review
Article Snippet: .. ACD from colophonium or modified colophonium has been reported in patients using the Dexcom G7 sensor, Enlite sensor, the Omnipod pump, the Omnopid DASH the FSL sensor and the TouchCare A6 pump and sensor. ..

Article Title: Allergic contact dermatitis caused by glucose sensors and insulin pumps: A full review: Part 1: Sensors and pumps, adverse cutaneous reactions, allergens, and diabetes devices causing allergic contact dermatitis.
Article Snippet: .. Colophonium in the European baseline series was negative, as is often the case with patients sensitised to modified colophonium products (chapter 4.3.2).147 A 3-year-old girl with ACD from colophonium in the Enlite sensor had a positive patch test to an ‘Overtape dressing’ and a moisturising cream (no further data available).36 An 18-year-old female patient had a positive patch test to ‘isopropyl alcohol wipes’ (++ on D4), but there were no other positive reactions.36 An 8-year-old boy had developed ACD from IBOA, DMDI (dicyclohexylmethane-4,40-diisocyanate) and (derivatives of) colophonium in the Dexcom G7 sensor. ..

Gas Chromatography-Mass Spectrometry:

Article Title: Allergic contact dermatitis caused by glucose sensors and insulin pumps: A full review: Part 1: Sensors and pumps, adverse cutaneous reactions, allergens, and diabetes devices causing allergic contact dermatitis.
Article Snippet: .. In addition, a large number of single (sometimes 2 patients) case reports of ACD from IBOA in FSL have been published.36,40,54,69,74–92 The sudden and explosive rise of IBOA as an allergen in diabetes devices made IBOA the 2020 American Contact Dermatitis Society Allergen of the year.4 IBOA was also identified by chemical analyses using gas chromatography–mass spectrometry (GC–MS) in the commonly used glucose sensors Enlite and Dexcom G6, the patch pump Omnipod and various other diabetic devices (Table S1, Supporting information). ..

Article Title: Allergic contact dermatitis caused by glucose sensors and insulin pumps: A full review
Article Snippet: .. IBOA was also identified by chemical analyses using gas chromatography–mass spectrometry (GC–MS) in the commonly used glucose sensors Enlite and Dexcom G6, the patch pump Omnipod and various other diabetic devices (Table , Supporting information). ..

Adhesive:

Article Title: Contact allergy to the Dexcom G6 glucose monitoring system-Role of 2,2'-methylenebis(6-tert-butyl-4-methylphenol) monoacrylate in the new adhesive.
Article Snippet: .. IBOA moved into focus for a longer period of time, as it was also contained in further diabetic devices such as the Enlite sensor and the patch pump Omnipod.6–9 In contrary to the findings of Svedman et al.12 according to our studies from 2018 and 2019, IBOA concentrations in the adhesive patches of the Dexcom G5 and G6 sensor including the plastic sleigh and transmitter9,10 were below limit of quantification. .. Therefore, patients with IBOA allergy were able to use IBOA-free devices (e.g., Dexcom).

other:

Article Title: Clinical Performance Evaluation of Continuous Glucose Monitoring Systems: A Scoping Review and Recommendations for Reporting.
Article Snippet: Matuleviciene V, Joseph JI, Andelin M, et al. A clinical trial of the accuracy and treatment experience of the Dexcom G4 sensor (Dexcom G4 system) and Enlite sensor (guardian REAL-time system) tested simultaneously in ambulatory patients with type 1 diabetes.

Cream:

Article Title: Allergic contact dermatitis caused by glucose sensors and insulin pumps: A full review: Part 1: Sensors and pumps, adverse cutaneous reactions, allergens, and diabetes devices causing allergic contact dermatitis.
Article Snippet: .. Colophonium in the European baseline series was negative, as is often the case with patients sensitised to modified colophonium products (chapter 4.3.2).147 A 3-year-old girl with ACD from colophonium in the Enlite sensor had a positive patch test to an ‘Overtape dressing’ and a moisturising cream (no further data available).36 An 18-year-old female patient had a positive patch test to ‘isopropyl alcohol wipes’ (++ on D4), but there were no other positive reactions.36 An 8-year-old boy had developed ACD from IBOA, DMDI (dicyclohexylmethane-4,40-diisocyanate) and (derivatives of) colophonium in the Dexcom G7 sensor. ..



Similar Products

86
Dexcom Inc dexcom cgm sensor
Dexcom Cgm Sensor, supplied by Dexcom Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dexcom+sensor/cgm+sensors/pm42156180-52-2-2
Average 86 stars, based on 1 article reviews
dexcom cgm sensor - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Dexcom Inc dexcom g7 cgm sensor
Dexcom G7 Cgm Sensor, supplied by Dexcom Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dexcom+sensor/dexcom+g7+sensor/pm42156180-106-2-2
Average 86 stars, based on 1 article reviews
dexcom g7 cgm sensor - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Dexcom Inc dexcom g4 platinum sensor
Proposed amended reporting format for CGM sensor measurement limit capping, illustrated using two exemplar 14-day windows from the Aleppo 2017 Replace-BG trial (Dexcom <t>G4</t> Platinum) for the participant with the highest proportion of upper-limit capped readings (A-D) and the participant with the highest proportion of lower-limit capped readings (E-H). Panels A and E show the ambulatory glucose profile (AGP) with median glucose (red line) and shaded 25–75% and 10–90% interpercentile ranges. Grey shaded bands above and below the dashed device detection limit lines (400 and 40 mg/dL) indicate the glucose range that cannot be measured by the device. Panels B and F show glucose-range exposure as a stacked bar chart, with black segments at the top and bottom representing readings at or beyond the device detection limits, extending the standard display. Panels C and G summarise conventional window-level metrics alongside device-limit capping statistics (frequency and longest run duration), and panels D and H show the glucose frequency distribution with lower and upper capped bins shaded black. These display elements are proposed as optional additions to standard CGM reporting software, to be shown only when capping is present.
Dexcom G4 Platinum Sensor, supplied by Dexcom Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dexcom+sensor/dexcom+g4+platinum/med_rxiv__64898__2026__05__13__26353094-140-16-16
Average 86 stars, based on 1 article reviews
dexcom g4 platinum sensor - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Dexcom Inc dexcom sensors
Proposed amended reporting format for CGM sensor measurement limit capping, illustrated using two exemplar 14-day windows from the Aleppo 2017 Replace-BG trial (Dexcom <t>G4</t> Platinum) for the participant with the highest proportion of upper-limit capped readings (A-D) and the participant with the highest proportion of lower-limit capped readings (E-H). Panels A and E show the ambulatory glucose profile (AGP) with median glucose (red line) and shaded 25–75% and 10–90% interpercentile ranges. Grey shaded bands above and below the dashed device detection limit lines (400 and 40 mg/dL) indicate the glucose range that cannot be measured by the device. Panels B and F show glucose-range exposure as a stacked bar chart, with black segments at the top and bottom representing readings at or beyond the device detection limits, extending the standard display. Panels C and G summarise conventional window-level metrics alongside device-limit capping statistics (frequency and longest run duration), and panels D and H show the glucose frequency distribution with lower and upper capped bins shaded black. These display elements are proposed as optional additions to standard CGM reporting software, to be shown only when capping is present.
Dexcom Sensors, supplied by Dexcom Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dexcom+sensor/dexcom+sensors/med_rxiv__64898__2026__05__13__26353094-32-26-26
Average 86 stars, based on 1 article reviews
dexcom sensors - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Dexcom Inc dexcom g6 sensor
Proposed amended reporting format for CGM sensor measurement limit capping, illustrated using two exemplar 14-day windows from the Aleppo 2017 Replace-BG trial (Dexcom <t>G4</t> Platinum) for the participant with the highest proportion of upper-limit capped readings (A-D) and the participant with the highest proportion of lower-limit capped readings (E-H). Panels A and E show the ambulatory glucose profile (AGP) with median glucose (red line) and shaded 25–75% and 10–90% interpercentile ranges. Grey shaded bands above and below the dashed device detection limit lines (400 and 40 mg/dL) indicate the glucose range that cannot be measured by the device. Panels B and F show glucose-range exposure as a stacked bar chart, with black segments at the top and bottom representing readings at or beyond the device detection limits, extending the standard display. Panels C and G summarise conventional window-level metrics alongside device-limit capping statistics (frequency and longest run duration), and panels D and H show the glucose frequency distribution with lower and upper capped bins shaded black. These display elements are proposed as optional additions to standard CGM reporting software, to be shown only when capping is present.
Dexcom G6 Sensor, supplied by Dexcom Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dexcom+sensor/dexcom+g6+sensor/pm42108404-47-3-6
Average 86 stars, based on 1 article reviews
dexcom g6 sensor - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Dexcom Inc unblinded dexcom g7 sensor
Proposed amended reporting format for CGM sensor measurement limit capping, illustrated using two exemplar 14-day windows from the Aleppo 2017 Replace-BG trial (Dexcom <t>G4</t> Platinum) for the participant with the highest proportion of upper-limit capped readings (A-D) and the participant with the highest proportion of lower-limit capped readings (E-H). Panels A and E show the ambulatory glucose profile (AGP) with median glucose (red line) and shaded 25–75% and 10–90% interpercentile ranges. Grey shaded bands above and below the dashed device detection limit lines (400 and 40 mg/dL) indicate the glucose range that cannot be measured by the device. Panels B and F show glucose-range exposure as a stacked bar chart, with black segments at the top and bottom representing readings at or beyond the device detection limits, extending the standard display. Panels C and G summarise conventional window-level metrics alongside device-limit capping statistics (frequency and longest run duration), and panels D and H show the glucose frequency distribution with lower and upper capped bins shaded black. These display elements are proposed as optional additions to standard CGM reporting software, to be shown only when capping is present.
Unblinded Dexcom G7 Sensor, supplied by Dexcom Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dexcom+sensor/dexcom+g7+sensor/pm42092238-19-34-35
Average 86 stars, based on 1 article reviews
unblinded dexcom g7 sensor - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Dexcom Inc dexcom g7 sensor
Proposed amended reporting format for CGM sensor measurement limit capping, illustrated using two exemplar 14-day windows from the Aleppo 2017 Replace-BG trial (Dexcom <t>G4</t> Platinum) for the participant with the highest proportion of upper-limit capped readings (A-D) and the participant with the highest proportion of lower-limit capped readings (E-H). Panels A and E show the ambulatory glucose profile (AGP) with median glucose (red line) and shaded 25–75% and 10–90% interpercentile ranges. Grey shaded bands above and below the dashed device detection limit lines (400 and 40 mg/dL) indicate the glucose range that cannot be measured by the device. Panels B and F show glucose-range exposure as a stacked bar chart, with black segments at the top and bottom representing readings at or beyond the device detection limits, extending the standard display. Panels C and G summarise conventional window-level metrics alongside device-limit capping statistics (frequency and longest run duration), and panels D and H show the glucose frequency distribution with lower and upper capped bins shaded black. These display elements are proposed as optional additions to standard CGM reporting software, to be shown only when capping is present.
Dexcom G7 Sensor, supplied by Dexcom Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dexcom+sensor/dexcom+g7+sensor/pmc13128380-112-1-1
Average 86 stars, based on 1 article reviews
dexcom g7 sensor - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Dexcom Inc dexcom sensor
Proposed amended reporting format for CGM sensor measurement limit capping, illustrated using two exemplar 14-day windows from the Aleppo 2017 Replace-BG trial (Dexcom <t>G4</t> Platinum) for the participant with the highest proportion of upper-limit capped readings (A-D) and the participant with the highest proportion of lower-limit capped readings (E-H). Panels A and E show the ambulatory glucose profile (AGP) with median glucose (red line) and shaded 25–75% and 10–90% interpercentile ranges. Grey shaded bands above and below the dashed device detection limit lines (400 and 40 mg/dL) indicate the glucose range that cannot be measured by the device. Panels B and F show glucose-range exposure as a stacked bar chart, with black segments at the top and bottom representing readings at or beyond the device detection limits, extending the standard display. Panels C and G summarise conventional window-level metrics alongside device-limit capping statistics (frequency and longest run duration), and panels D and H show the glucose frequency distribution with lower and upper capped bins shaded black. These display elements are proposed as optional additions to standard CGM reporting software, to be shown only when capping is present.
Dexcom Sensor, supplied by Dexcom Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dexcom+sensor/dexcom+sensor/pmc13065641-82-22-22
Average 86 stars, based on 1 article reviews
dexcom sensor - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Dexcom Inc dexcom g4 sensor
Proposed amended reporting format for CGM sensor measurement limit capping, illustrated using two exemplar 14-day windows from the Aleppo 2017 Replace-BG trial (Dexcom <t>G4</t> Platinum) for the participant with the highest proportion of upper-limit capped readings (A-D) and the participant with the highest proportion of lower-limit capped readings (E-H). Panels A and E show the ambulatory glucose profile (AGP) with median glucose (red line) and shaded 25–75% and 10–90% interpercentile ranges. Grey shaded bands above and below the dashed device detection limit lines (400 and 40 mg/dL) indicate the glucose range that cannot be measured by the device. Panels B and F show glucose-range exposure as a stacked bar chart, with black segments at the top and bottom representing readings at or beyond the device detection limits, extending the standard display. Panels C and G summarise conventional window-level metrics alongside device-limit capping statistics (frequency and longest run duration), and panels D and H show the glucose frequency distribution with lower and upper capped bins shaded black. These display elements are proposed as optional additions to standard CGM reporting software, to be shown only when capping is present.
Dexcom G4 Sensor, supplied by Dexcom Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dexcom+sensor/dexcom+g4+sensor/pmc13065641-63-9-9
Average 86 stars, based on 1 article reviews
dexcom g4 sensor - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

Image Search Results


Proposed amended reporting format for CGM sensor measurement limit capping, illustrated using two exemplar 14-day windows from the Aleppo 2017 Replace-BG trial (Dexcom G4 Platinum) for the participant with the highest proportion of upper-limit capped readings (A-D) and the participant with the highest proportion of lower-limit capped readings (E-H). Panels A and E show the ambulatory glucose profile (AGP) with median glucose (red line) and shaded 25–75% and 10–90% interpercentile ranges. Grey shaded bands above and below the dashed device detection limit lines (400 and 40 mg/dL) indicate the glucose range that cannot be measured by the device. Panels B and F show glucose-range exposure as a stacked bar chart, with black segments at the top and bottom representing readings at or beyond the device detection limits, extending the standard display. Panels C and G summarise conventional window-level metrics alongside device-limit capping statistics (frequency and longest run duration), and panels D and H show the glucose frequency distribution with lower and upper capped bins shaded black. These display elements are proposed as optional additions to standard CGM reporting software, to be shown only when capping is present.

Journal: medRxiv

Article Title: Prevalence, duration, and clinical implications of Continuous Glucose Monitor (CGM) measurement limit capping in type 1 diabetes

doi: 10.64898/2026.05.13.26353094

Figure Lengend Snippet: Proposed amended reporting format for CGM sensor measurement limit capping, illustrated using two exemplar 14-day windows from the Aleppo 2017 Replace-BG trial (Dexcom G4 Platinum) for the participant with the highest proportion of upper-limit capped readings (A-D) and the participant with the highest proportion of lower-limit capped readings (E-H). Panels A and E show the ambulatory glucose profile (AGP) with median glucose (red line) and shaded 25–75% and 10–90% interpercentile ranges. Grey shaded bands above and below the dashed device detection limit lines (400 and 40 mg/dL) indicate the glucose range that cannot be measured by the device. Panels B and F show glucose-range exposure as a stacked bar chart, with black segments at the top and bottom representing readings at or beyond the device detection limits, extending the standard display. Panels C and G summarise conventional window-level metrics alongside device-limit capping statistics (frequency and longest run duration), and panels D and H show the glucose frequency distribution with lower and upper capped bins shaded black. These display elements are proposed as optional additions to standard CGM reporting software, to be shown only when capping is present.

Article Snippet: Our BGM comparison is restricted to a single arm of a single trial using the older Dexcom G4 Platinum sensor (mean absolute relative difference (MARD) ∼14%), which has lower accuracy than the Dexcom G6 (MARD ∼9%) used in three of our four datasets.

Techniques: Software