Review



slidebook™ software (slidebook™ version 5.5.2.0  (3i - Intelligent Imaging)

 
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    3i - Intelligent Imaging slidebook™ software (slidebook™ version 5.5.2.0
    ( A ) MARCKS and ubiquitin protein expression in CEM/WT cells, CEM/BTZ7 cells treated with 30 nM BTZ for 24 hours and CEM/BTZ200 cells treated with 400 nM BTZ for 24 hours. Left panel: DAPI nuclear staining (Blue), ubiquitin (Green), and MARCKS (Red), right panel: level of co-localization of MARCKS with ubiquitin as calculated by the <t>SlideBook</t> microscope software as depicted in blue (normal) to magenta (strong co-localization). Single channel images are shown in . ( B ) Ubiquitin (green) and DAPI (blue) staining in HeLa cells after 24 hour incubation with the supernatants of cultures of CEM/WT, CEM/BTZ7 and CEM/BTZ200 cells untreated or treated with the indicated concentrations of BTZ for 1 hour. ( C ) PKH labeling and ubiquitin protein expression in CEM/WT cells, CEM/BTZ7 and CEM/BTZ200 cells treated with the abovementioned concentrations of BTZ for 24 hours. DAPI nuclear staining (Blue), PKH (Green), and ubiquitin (Red) and level of colocalization of MARCKS with ubiquitin as calculated by the SlideBook microscope software as depicted in blue to magenta (Right panel). ( D ) Ubiquitin (red) and PKH (green) staining in HeLa cells after 24 hour incubation with the supernatants of cultures of CEM/WT, CEM/BTZ7 and CEM/BTZ200 cells untreated or treated with the indicated concentrations of BTZ. Calculated co-localization is depicted in yellow. ( E ) Ubiquitin (green) and MARCKS (red) staining in a primary ALL patient samples, one sensitive to BTZ (LC50: BTZ 6 nM) and one resistant to BTZ (LC50 BTZ: 262 nM) ( F ) without and after incubation with low concentration (7 nM) or high concentration of BTZ (400 nM). In the merge figure, the co-localization of the two proteins is shown in yellow. The right top of the figures depict a quantification using a line scan through the corresponding area of interest (α and β).
    Slidebook™ Software (Slidebook™ Version 5.5.2.0, supplied by 3i - Intelligent Imaging, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/data+processing+hyperion+mass+imaging+system/slidebook+software/pmc05342701-237-5-10
    Average 90 stars, based on 1 article reviews
    slidebook™ software (slidebook™ version 5.5.2.0 - by Bioz Stars, 2026-11
    90/100 stars

    Images

    1) Product Images from "Exocytosis of polyubiquitinated proteins in bortezomib-resistant leukemia cells: a role for MARCKS in acquired resistance to proteasome inhibitors"

    Article Title: Exocytosis of polyubiquitinated proteins in bortezomib-resistant leukemia cells: a role for MARCKS in acquired resistance to proteasome inhibitors

    Journal: Oncotarget

    doi: 10.18632/oncotarget.11340

    ( A ) MARCKS and ubiquitin protein expression in CEM/WT cells, CEM/BTZ7 cells treated with 30 nM BTZ for 24 hours and CEM/BTZ200 cells treated with 400 nM BTZ for 24 hours. Left panel: DAPI nuclear staining (Blue), ubiquitin (Green), and MARCKS (Red), right panel: level of co-localization of MARCKS with ubiquitin as calculated by the SlideBook microscope software as depicted in blue (normal) to magenta (strong co-localization). Single channel images are shown in . ( B ) Ubiquitin (green) and DAPI (blue) staining in HeLa cells after 24 hour incubation with the supernatants of cultures of CEM/WT, CEM/BTZ7 and CEM/BTZ200 cells untreated or treated with the indicated concentrations of BTZ for 1 hour. ( C ) PKH labeling and ubiquitin protein expression in CEM/WT cells, CEM/BTZ7 and CEM/BTZ200 cells treated with the abovementioned concentrations of BTZ for 24 hours. DAPI nuclear staining (Blue), PKH (Green), and ubiquitin (Red) and level of colocalization of MARCKS with ubiquitin as calculated by the SlideBook microscope software as depicted in blue to magenta (Right panel). ( D ) Ubiquitin (red) and PKH (green) staining in HeLa cells after 24 hour incubation with the supernatants of cultures of CEM/WT, CEM/BTZ7 and CEM/BTZ200 cells untreated or treated with the indicated concentrations of BTZ. Calculated co-localization is depicted in yellow. ( E ) Ubiquitin (green) and MARCKS (red) staining in a primary ALL patient samples, one sensitive to BTZ (LC50: BTZ 6 nM) and one resistant to BTZ (LC50 BTZ: 262 nM) ( F ) without and after incubation with low concentration (7 nM) or high concentration of BTZ (400 nM). In the merge figure, the co-localization of the two proteins is shown in yellow. The right top of the figures depict a quantification using a line scan through the corresponding area of interest (α and β).
    Figure Legend Snippet: ( A ) MARCKS and ubiquitin protein expression in CEM/WT cells, CEM/BTZ7 cells treated with 30 nM BTZ for 24 hours and CEM/BTZ200 cells treated with 400 nM BTZ for 24 hours. Left panel: DAPI nuclear staining (Blue), ubiquitin (Green), and MARCKS (Red), right panel: level of co-localization of MARCKS with ubiquitin as calculated by the SlideBook microscope software as depicted in blue (normal) to magenta (strong co-localization). Single channel images are shown in . ( B ) Ubiquitin (green) and DAPI (blue) staining in HeLa cells after 24 hour incubation with the supernatants of cultures of CEM/WT, CEM/BTZ7 and CEM/BTZ200 cells untreated or treated with the indicated concentrations of BTZ for 1 hour. ( C ) PKH labeling and ubiquitin protein expression in CEM/WT cells, CEM/BTZ7 and CEM/BTZ200 cells treated with the abovementioned concentrations of BTZ for 24 hours. DAPI nuclear staining (Blue), PKH (Green), and ubiquitin (Red) and level of colocalization of MARCKS with ubiquitin as calculated by the SlideBook microscope software as depicted in blue to magenta (Right panel). ( D ) Ubiquitin (red) and PKH (green) staining in HeLa cells after 24 hour incubation with the supernatants of cultures of CEM/WT, CEM/BTZ7 and CEM/BTZ200 cells untreated or treated with the indicated concentrations of BTZ. Calculated co-localization is depicted in yellow. ( E ) Ubiquitin (green) and MARCKS (red) staining in a primary ALL patient samples, one sensitive to BTZ (LC50: BTZ 6 nM) and one resistant to BTZ (LC50 BTZ: 262 nM) ( F ) without and after incubation with low concentration (7 nM) or high concentration of BTZ (400 nM). In the merge figure, the co-localization of the two proteins is shown in yellow. The right top of the figures depict a quantification using a line scan through the corresponding area of interest (α and β).

    Techniques Used: Expressing, Staining, Microscopy, Software, Incubation, Labeling, Concentration Assay

    Related Articles

    other:

    Article Title: Molecular circuit between Aspergillus nidulans transcription factors MsnA and VelB to coordinate fungal stress and developmental responses
    Article Snippet: Fluorescence microscopy was performed with the inverted confocal microscope Zeiss AxioObserver, Z.1 (Zeiss, Oberkochen, Germany), and the software SlideBook 6.0 software package (Intelligent Imaging Innovations GmbH, Göttingen, Germany).

    Article Title: The Aspergillus nidulans velvet domain containing transcription factor VeA is shuttled from cytoplasm into nucleus during vegetative growth and stays there for sexual development, but has to return into cytoplasm for asexual development
    Article Snippet: The confocal Axiolab light microscope was used in combination with the SlideBook 6.0 software package (Intelligent Imaging Innovations GmbH).

    Article Title: Light-activated tetanus neurotoxin for conditional proteolysis and inducible synaptic inhibition in vivo
    Article Snippet: Image acquisition and processing was carried out with the SlideBook 5.0 software (Intelligent Imaging Innovations, 3i).

    Microscopy:

    Article Title: Enhancing the efficiency of oncolytic vaccinia virus for ovarian cancer treatment
    Article Snippet: .. The microscope was controlled by Slidebook software (3i Intelligent Imaging Innovations). ..

    Article Title: Embryonic macrophages in brown adipose tissue are spatially associated with developing nerves
    Article Snippet: .. Image acquisition, processing, and analysis was performed with 3i CSU-W1 spinning disk confocal microscope (Intelligent Imaging Innovations) equipped with Photometrics Prime BSI sCMOS camera (Teledyne Imaging) and Plan-Apochromat Zeiss 10x/0.45 or Plan-Apochromat Zeiss 20x/0.8 dry objectives, using SlideBook 6 software (Intelligent Imaging Innovations) and ImageJ software (1.54b). ..

    Article Title: Targeting TRPC channels for control of arthritis-induced bone erosion
    Article Snippet: .. Fluorescent measurements were made using a Leica DMI 6000B fluorescence microscope controlled by Slidebook Software (Intelligent Imaging Innovations, Denver, CO). .. Fluorescent measurements were made using a Leica DMI 6000B fluorescence microscope controlled by Slidebook Software (Intelligent Imaging Innovations, Denver, CO).

    Software:

    Article Title: Enhancing the efficiency of oncolytic vaccinia virus for ovarian cancer treatment
    Article Snippet: .. The microscope was controlled by Slidebook software (3i Intelligent Imaging Innovations). ..

    Article Title: Embryonic macrophages in brown adipose tissue are spatially associated with developing nerves
    Article Snippet: .. Image acquisition, processing, and analysis was performed with 3i CSU-W1 spinning disk confocal microscope (Intelligent Imaging Innovations) equipped with Photometrics Prime BSI sCMOS camera (Teledyne Imaging) and Plan-Apochromat Zeiss 10x/0.45 or Plan-Apochromat Zeiss 20x/0.8 dry objectives, using SlideBook 6 software (Intelligent Imaging Innovations) and ImageJ software (1.54b). ..

    Article Title: Loss of Sirtuin 7 impairs cell motility and proliferation and enhances S-phase cell arrest after 5-fluorouracil treatment in head and neck cancer.
    Article Snippet: .. Their fluorescence was quantified by creating masks for each wavelength, obtaining the average voxel value in the object and the mask statistics in the SlideBook6 software (Intelligent Imaging Innovations Inc., USA). ..

    Article Title: Targeting TRPC channels for control of arthritis-induced bone erosion
    Article Snippet: .. Fluorescent measurements were made using a Leica DMI 6000B fluorescence microscope controlled by Slidebook Software (Intelligent Imaging Innovations, Denver, CO). .. Fluorescent measurements were made using a Leica DMI 6000B fluorescence microscope controlled by Slidebook Software (Intelligent Imaging Innovations, Denver, CO).

    Article Title: Relative Distribution of DnaA and DNA in Escherichia coli Cells as a Factor of Their Phenotypic Variability.
    Article Snippet: The Zeiss Axio-Observer 7 inverted microscope (ZEISS MI, Carl Zeiss, Oberkochen, Germany) was used with the 3i Marianas (Denver, CO, USA) spinning disk confocal microscope equipped with the Yokogawa W1 module (Yokogawa, Tokyo, Japan) and Prime 95B sCMOS camera (pixel size 0.106 microns) (Photometrics, Tucson, USA). .. The acquisition was controlled using SlideBook software (Intelligent Imaging Innovations, SlideBook v2304). ..

    Imaging:

    Article Title: Embryonic macrophages in brown adipose tissue are spatially associated with developing nerves
    Article Snippet: .. Image acquisition, processing, and analysis was performed with 3i CSU-W1 spinning disk confocal microscope (Intelligent Imaging Innovations) equipped with Photometrics Prime BSI sCMOS camera (Teledyne Imaging) and Plan-Apochromat Zeiss 10x/0.45 or Plan-Apochromat Zeiss 20x/0.8 dry objectives, using SlideBook 6 software (Intelligent Imaging Innovations) and ImageJ software (1.54b). ..

    Fluorescence:

    Article Title: Loss of Sirtuin 7 impairs cell motility and proliferation and enhances S-phase cell arrest after 5-fluorouracil treatment in head and neck cancer.
    Article Snippet: .. Their fluorescence was quantified by creating masks for each wavelength, obtaining the average voxel value in the object and the mask statistics in the SlideBook6 software (Intelligent Imaging Innovations Inc., USA). ..

    Article Title: Targeting TRPC channels for control of arthritis-induced bone erosion
    Article Snippet: .. Fluorescent measurements were made using a Leica DMI 6000B fluorescence microscope controlled by Slidebook Software (Intelligent Imaging Innovations, Denver, CO). .. Fluorescent measurements were made using a Leica DMI 6000B fluorescence microscope controlled by Slidebook Software (Intelligent Imaging Innovations, Denver, CO).



    Similar Products

    93
    fluidigm data processing hyperion mass imaging system
    Data Processing Hyperion Mass Imaging System, supplied by fluidigm, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/data+processing+hyperion+mass+imaging+system/Hyperion+Imaging+Mass+Cytometry+System/pm41672987-268-13-19
    Average 93 stars, based on 1 article reviews
    data processing hyperion mass imaging system - by Bioz Stars, 2026-11
    93/100 stars
      Buy from Supplier

    Image Search Results