Review



cross recurrence plot toolbox for matlab  (MathWorks Inc)


Bioz Verified Symbol MathWorks Inc is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 96

    Structured Review

    MathWorks Inc cross recurrence plot toolbox for matlab
    Cross Recurrence Plot Toolbox For Matlab, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 96/100, based on 2350 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cross+recurrence+plot+matlab+toolbox/Database+Toolbox/pmc07516420-200-17-22
    Average 96 stars, based on 2350 article reviews
    cross recurrence plot toolbox for matlab - by Bioz Stars, 2026-11
    96/100 stars

    Images

    Related Articles

    Software:

    Article Title: Alpha‐adrenergic mediated changes in blood pressure variability after hypoxia‐ischaemia in preterm fetal sheep
    Article Snippet: .. For beat-to-beat BPV analysis, systolic arterial blood pressure peak amplitudes were extracted using LabVIEW software and imported into a customised physiological data analysis toolbox using MATLAB (MATLAB 2023A; The MathWorks, Inc., Natick, MA, USA) to calculate features of beat-to-beat variability. ..

    Clinical Proteomics:

    Article Title: Parvalbumin-positive neurons in the medial septum participate in the formation of hippocampal-dependent spatial memory.
    Article Snippet: .. The EDF files were exported to MATLAB and then analysis sleep state using an open source MATLAB toolbox (https://data.mendeley.com/datasets/c872f83pdz/4)58 Plasma corticosterone measures Plasma samples were collected approximately 12-15 hours after SD, including from the gentle handling SD group. ..

    Article Title: Parvalbumin-positive neurons in the medial septum participate in the formation of hippocampal-dependent spatial memory.
    Article Snippet: .. The EDF files were exported to MATLAB and then analysis sleep state using an open source MATLAB toolbox (https://data.mendeley.com/datasets/c872f83pdz/4) Plasma corticosterone measures Plasma samples were collected approximately 12-15 hours after SD, including from the gentle handling SD group. ..

    Gentle:

    Article Title: Parvalbumin-positive neurons in the medial septum participate in the formation of hippocampal-dependent spatial memory.
    Article Snippet: .. The EDF files were exported to MATLAB and then analysis sleep state using an open source MATLAB toolbox (https://data.mendeley.com/datasets/c872f83pdz/4)58 Plasma corticosterone measures Plasma samples were collected approximately 12-15 hours after SD, including from the gentle handling SD group. ..

    Article Title: Parvalbumin-positive neurons in the medial septum participate in the formation of hippocampal-dependent spatial memory.
    Article Snippet: .. The EDF files were exported to MATLAB and then analysis sleep state using an open source MATLAB toolbox (https://data.mendeley.com/datasets/c872f83pdz/4) Plasma corticosterone measures Plasma samples were collected approximately 12-15 hours after SD, including from the gentle handling SD group. ..

    Generated:

    Article Title: Opposing cortical forces: Alpha slowing and sensorimotor mu acceleration during motor-related BCI training.
    Article Snippet: .. Topoplots were generated using the MATLAB toolbox from Víctor Martínez-Cagigal (2025): Topographic EEG/MEG plot (https://www.mathworks.com/matlabcentral/fileexchange/72729-topographic-eeg-meg-plot). https://doi.org/10.1371/journal.pcbi.1014112.g003 PLOS Computational Biology | https://doi.org/10.1371/journal.pcbi.1014112 April 1, 2026 8 / 22 showing a positive association with posterior alpha frequency acceleration with effects ranging from negligible to moderate depending on dataset. ..

    other:

    Article Title: From statistics to deep learning in single-molecule fluorescence resonance energy transfer analysis.
    Article Snippet: MASH-FRET [9,26], a MATLAB-based toolbox, uses the BOBA-FRET’s analysis and simulation framework, while adding workflows for molecule localisation and dynamic characterisation. iSMS [27] and SMART [28] offer graphical interfaces for data analysis and visualisation, and enhance standard HMM by incorporating VB and the Bayesian Information Criterion (BIC) while estimating the number of states.

    Functional Assay:

    Article Title: Fronto-Cerebellar Connectivity Disruptions and Functional Reorganization in Friedreich's Ataxia: A Structural and Resting-State fMRI Study.
    Article Snippet: .. For functional data, grouplevel analyses were performed using the CONN toolbox in MATLAB (v.R2022a) (Nieto-Castanon and Whitfield-Gabrieli, 2022). ..



    Similar Products

    90
    MathWorks Inc cross recurrence plot toolbox for matlab sensors 2025
    Cross Recurrence Plot Toolbox For Matlab Sensors 2025, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cross+recurrence+plot+matlab+toolbox/pm40096400-84-20-20
    Average 90 stars, based on 1 article reviews
    cross recurrence plot toolbox for matlab sensors 2025 - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    96
    MathWorks Inc cross recurrence plot toolbox for matlab
    Cross Recurrence Plot Toolbox For Matlab, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cross+recurrence+plot+matlab+toolbox/Database+Toolbox/pmc11902333-240-15-20
    Average 96 stars, based on 1 article reviews
    cross recurrence plot toolbox for matlab - by Bioz Stars, 2026-11
    96/100 stars
      Buy from Supplier

    96
    MathWorks Inc cross recurrence plot toolbox in matlab
    Cross Recurrence Plot Toolbox In Matlab, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cross+recurrence+plot+matlab+toolbox/Partial+Differential+Equation+Toolbox/bio_rxiv__2023__10__19__563062-118-6-11
    Average 96 stars, based on 1 article reviews
    cross recurrence plot toolbox in matlab - by Bioz Stars, 2026-11
    96/100 stars
      Buy from Supplier

    90
    MathWorks Inc cross recurrence plot matlab toolbox
    ( a ) Example cross-recurrence plot for the response to one 30 s current step trial against that of the subsequent trial. Threshold (ε) = σ ISI , embedding dimension m = 4. Each point colored black denotes where sequences of 4 ISIs in each of the two trials were closer than ε to each other. ( b ) random shuffling of both sets of ISIs results in a loss of recurrence (proportion of black points in the matrix) and determinism (fraction of black points within diagonals of length 2 or greater. ( c ) Distribution of the recurrence values (each of which is the mean over 7 successive pairwise comparisons of consecutive 10 s trials during stationary firing) for 1000 shuffled surrogates (each ISI sequence in the <t>CRP</t> is randomly permuted), compared to the actual corresponding measured recurrence level (indicated by vertical dotted gray line) over the same set of trials. ( d ) the same for the determinism (fraction of recurrent points lying within diagonals of length ≥ 2). A z <t>-test</t> <t>(Matlab</t> ztest, right-tailed) confirms that both recurrence (p<7.52e-9) and determinism (p<0.023) are significant in this case. DOI: http://dx.doi.org/10.7554/eLife.16475.007
    Cross Recurrence Plot Matlab Toolbox, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cross+recurrence+plot+matlab+toolbox/pmc05030087-341-11-15
    Average 90 stars, based on 1 article reviews
    cross recurrence plot matlab toolbox - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    ( a ) Example cross-recurrence plot for the response to one 30 s current step trial against that of the subsequent trial. Threshold (ε) = σ ISI , embedding dimension m = 4. Each point colored black denotes where sequences of 4 ISIs in each of the two trials were closer than ε to each other. ( b ) random shuffling of both sets of ISIs results in a loss of recurrence (proportion of black points in the matrix) and determinism (fraction of black points within diagonals of length 2 or greater. ( c ) Distribution of the recurrence values (each of which is the mean over 7 successive pairwise comparisons of consecutive 10 s trials during stationary firing) for 1000 shuffled surrogates (each ISI sequence in the CRP is randomly permuted), compared to the actual corresponding measured recurrence level (indicated by vertical dotted gray line) over the same set of trials. ( d ) the same for the determinism (fraction of recurrent points lying within diagonals of length ≥ 2). A z -test (Matlab ztest, right-tailed) confirms that both recurrence (p<7.52e-9) and determinism (p<0.023) are significant in this case. DOI: http://dx.doi.org/10.7554/eLife.16475.007

    Journal: eLife

    Article Title: Stochastic and deterministic dynamics of intrinsically irregular firing in cortical inhibitory interneurons

    doi: 10.7554/eLife.16475

    Figure Lengend Snippet: ( a ) Example cross-recurrence plot for the response to one 30 s current step trial against that of the subsequent trial. Threshold (ε) = σ ISI , embedding dimension m = 4. Each point colored black denotes where sequences of 4 ISIs in each of the two trials were closer than ε to each other. ( b ) random shuffling of both sets of ISIs results in a loss of recurrence (proportion of black points in the matrix) and determinism (fraction of black points within diagonals of length 2 or greater. ( c ) Distribution of the recurrence values (each of which is the mean over 7 successive pairwise comparisons of consecutive 10 s trials during stationary firing) for 1000 shuffled surrogates (each ISI sequence in the CRP is randomly permuted), compared to the actual corresponding measured recurrence level (indicated by vertical dotted gray line) over the same set of trials. ( d ) the same for the determinism (fraction of recurrent points lying within diagonals of length ≥ 2). A z -test (Matlab ztest, right-tailed) confirms that both recurrence (p<7.52e-9) and determinism (p<0.023) are significant in this case. DOI: http://dx.doi.org/10.7554/eLife.16475.007

    Article Snippet: Recurrence plot (RP) analysis ( ) was carried out using the Cross Recurrence Plot (CRP) Matlab toolbox ( ).

    Techniques: Sequencing