Review




Structured Review

Corning Life Sciences transwell insert costar upper compartment
Transwell Insert Costar Upper Compartment, supplied by Corning Life Sciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/compartment+insert/transwell+compartment/pmc09102452-257-19-21
Average 90 stars, based on 1 article reviews
transwell insert costar upper compartment - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

Migration:

Article Title: Promotion of osteochondral repair through immune microenvironment regulation and activation of endogenous chondrogenesis via the release of apoptotic vesicles from donor MSCs
Article Snippet: The change in the scratch area was quantified using ImageJ software (NIH Image, US). .. Transwell migration assays were conducted as follows: a BMSCs suspension (100 μl; 2 × 10 5 cells/ml) was added to the upper Transwell compartment (Corning, US). ..

Article Title: Low expression of ZFP36L1 in osteosarcoma promotes lung metastasis by inhibiting the SDC4-TGF-β signaling feedback loop.
Article Snippet: .. OS cell migration was assessed using 24-well plate-sized Transwell compartments with a pore size of 8 μm (Corning Falcon, USA). ..

Suspension:

Article Title: Promotion of osteochondral repair through immune microenvironment regulation and activation of endogenous chondrogenesis via the release of apoptotic vesicles from donor MSCs
Article Snippet: The change in the scratch area was quantified using ImageJ software (NIH Image, US). .. Transwell migration assays were conducted as follows: a BMSCs suspension (100 μl; 2 × 10 5 cells/ml) was added to the upper Transwell compartment (Corning, US). ..

Concentration Assay:

Article Title: Network Pharmacological Analysis and Experimental Validation of the Effects of Silybin on Proliferation, Migration, and Immunotherapy of Papillary Thyroid Cancer.
Article Snippet: Aim: The study aimed to use network pharmacology research and in vitro experiments to investigate the material basis and molecular mechanisms of silybin in the treatment of papillary

Flow Cytometry:

Article Title: N 6 -methyladenosine-regulated exosome biogenesis orchestrates an immunosuppressive pre-metastatic niche in gastric cancer peritoneal metastasis.
Article Snippet: Following isolation, cells were labeled with CellTraceTM carboxyfluorescein succinimidyl ester (CFSE, 65-0850-84, Invitrogen) and stimulated with Dynabeads R© Mouse TActivator CD3/CD28 for T-Cell Expansion and Activation (11453D, Gibco, Waltham, MA, USA) and Mouse IL-2 Recombinant Protein (50 ng/mL; 212-12, PeproTech, Rocky Hill, NJ, USA). .. After treatment with exosomes or coculture with macrophages pretreated with exosomes or overexpressingmiR-17-92 cluster using Transwell compartments (six-well plate; Corning, NY, USA), the expanded T lymphocytes were harvested, and their proliferation was evaluated using flow cytometry after 72 h. ..

other:

Article Title: MiR-BART1-3p and BART18-5p inhibit cell migration, proliferation and activate autophagy in Epstein-Barr virus-associated gastric cancer by targeting erythropoietin-producing human hepatocellular 2.
Article Snippet: Epstein-Barr virus (EBV) is a human tumor-associated virus that encodes various microRNAs.. EBV infection causes a variety of malignant tumors, including nasopharyngeal carcinoma and gastric cancer, etc.. EBV-associated gastric cancer (EBVaGC) has unique molecular characteristics from other gastric cancers, but its pathogenic mechanism remains unclear.

Pore Size:

Article Title: Low expression of ZFP36L1 in osteosarcoma promotes lung metastasis by inhibiting the SDC4-TGF-β signaling feedback loop.
Article Snippet: .. OS cell migration was assessed using 24-well plate-sized Transwell compartments with a pore size of 8 μm (Corning Falcon, USA). ..

Transfection:

Article Title: Hsa_circ_0080608 Attenuates Lung Cancer Progression by Functioning as a Competitive Endogenous RNA to Regulate the miR-661/ADRA1A Pathway.
Article Snippet: Lung cancer is the second most common form of cancer, accounting for 11.4 % of all cancer cases and 18 % of all cancer-related deaths in 2020 [1].. Non-small cell lung cancer (NSCLC) is the most common type of lung cancer, accounting for over 85 % of all lung cancer cases [2].. Patients with NSCLC have a high mortality rate and only a 5 % five-year survival rate [3].



Similar Products

90
ibidi GmbH four-compartment culture inserts ibidi
Four Compartment Culture Inserts Ibidi, supplied by ibidi GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/compartment+insert/four+compartment+culture+inserts+ibidi/pm40070022-357-26-29
Average 90 stars, based on 1 article reviews
four-compartment culture inserts ibidi - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
ibidi GmbH four-compartment culture inserts
Four Compartment Culture Inserts, supplied by ibidi GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/compartment+insert/four+compartment+culture+inserts/pmc11897063-327-27-30
Average 90 stars, based on 1 article reviews
four-compartment culture inserts - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Corning Life Sciences 2-compartment boyden chamber with a physical barrier of an 8 μm polycarbonate membrane transwell insert
2 Compartment Boyden Chamber With A Physical Barrier Of An 8 μm Polycarbonate Membrane Transwell Insert, supplied by Corning Life Sciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/compartment+insert/2+compartment+boyden+chamber+with+a+physical+barrier+of+an+8+%CE%BCm+polycarbonate+membrane+transwell+insert/10__3390_slash_ijms26051822-302-6-21
Average 90 stars, based on 1 article reviews
2-compartment boyden chamber with a physical barrier of an 8 μm polycarbonate membrane transwell insert - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
ibidi GmbH sterile compartment culture-insert 2well
Sterile Compartment Culture Insert 2well, supplied by ibidi GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/compartment+insert/double+well+culture+inserts/10__1016_slash_j__preme__2024__100005-80-11-15
Average 90 stars, based on 1 article reviews
sterile compartment culture-insert 2well - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

99
BMG Labtech cell culture insert compartments
Cell Culture Insert Compartments, supplied by BMG Labtech, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/compartment+insert/FLUOstar+Omega/pm38386637-222-15-27
Average 99 stars, based on 1 article reviews
cell culture insert compartments - by Bioz Stars, 2026-11
99/100 stars
  Buy from Supplier

97
Med Associates Inc compartments
A) Experimental timeline of the conditioned place preference (CPP) paradigm. B) Illustration of the CPP apparatus in the low and high context version of the apparatus. In the low context version, the walls were distinctly patterned with horizontal stripes in the “left” compartment and zig zag stripes in the “right” compartment, but the flooring was smooth in both <t>compartments.</t> In the high context version, the flooring was also distinct between compartments, with the “left” compartment altered to a textured rubber flooring to distinguish it tactilely from the “right” compartment smooth flooring. C-D) % Time spent in the left compartment of the apparatus in the low ( C ) and high ( D ) context versions of the apparatus on the pretest, when mice could freely explore both compartments of the apparatus for the first time. Individual data points are color coded to reflect categorization of compartment bias on the pretest (pink: > 55%; teal: < 45%; black: between 45% and 55% in left compartment). *p < 0.05 for unpaired t-tests between males and females; # p < 0.05, #### p < 0.0001 for one-sample t-tests within group compared to the null hypothesis mean of 50%. E-F) Pretest locomotion in females and males, subcategorized by compartment bias of 55% as defined in C and D . Females had greater pretest locomotion than males in both the low ( E ) and high ( F ) context versions of the assay, but locomotion was unaffected by compartment bias. *p < 0.05, ****p < 0.0001 for main effects of sex in 2×2 ANOVAs.
Compartments, supplied by Med Associates Inc, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/compartment+insert/Two+Chamber+Place+Preference+Insert/bio_rxiv__2023__11__03__565492-33-14-26
Average 97 stars, based on 1 article reviews
compartments - by Bioz Stars, 2026-11
97/100 stars
  Buy from Supplier

96
AutoMate Scientific Inc compartments
A) Experimental timeline of the conditioned place preference (CPP) paradigm. B) Illustration of the CPP apparatus in the low and high context version of the apparatus. In the low context version, the walls were distinctly patterned with horizontal stripes in the “left” compartment and zig zag stripes in the “right” compartment, but the flooring was smooth in both <t>compartments.</t> In the high context version, the flooring was also distinct between compartments, with the “left” compartment altered to a textured rubber flooring to distinguish it tactilely from the “right” compartment smooth flooring. C-D) % Time spent in the left compartment of the apparatus in the low ( C ) and high ( D ) context versions of the apparatus on the pretest, when mice could freely explore both compartments of the apparatus for the first time. Individual data points are color coded to reflect categorization of compartment bias on the pretest (pink: > 55%; teal: < 45%; black: between 45% and 55% in left compartment). *p < 0.05 for unpaired t-tests between males and females; # p < 0.05, #### p < 0.0001 for one-sample t-tests within group compared to the null hypothesis mean of 50%. E-F) Pretest locomotion in females and males, subcategorized by compartment bias of 55% as defined in C and D . Females had greater pretest locomotion than males in both the low ( E ) and high ( F ) context versions of the assay, but locomotion was unaffected by compartment bias. *p < 0.05, ****p < 0.0001 for main effects of sex in 2×2 ANOVAs.
Compartments, supplied by AutoMate Scientific Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/compartment+insert/Dark+Box+Insert/bio_rxiv__2023__08__10__552874-297-16-9
Average 96 stars, based on 1 article reviews
compartments - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

90
Corning Life Sciences 24-well transwell inserts upper compartment pores
A) Experimental timeline of the conditioned place preference (CPP) paradigm. B) Illustration of the CPP apparatus in the low and high context version of the apparatus. In the low context version, the walls were distinctly patterned with horizontal stripes in the “left” compartment and zig zag stripes in the “right” compartment, but the flooring was smooth in both <t>compartments.</t> In the high context version, the flooring was also distinct between compartments, with the “left” compartment altered to a textured rubber flooring to distinguish it tactilely from the “right” compartment smooth flooring. C-D) % Time spent in the left compartment of the apparatus in the low ( C ) and high ( D ) context versions of the apparatus on the pretest, when mice could freely explore both compartments of the apparatus for the first time. Individual data points are color coded to reflect categorization of compartment bias on the pretest (pink: > 55%; teal: < 45%; black: between 45% and 55% in left compartment). *p < 0.05 for unpaired t-tests between males and females; # p < 0.05, #### p < 0.0001 for one-sample t-tests within group compared to the null hypothesis mean of 50%. E-F) Pretest locomotion in females and males, subcategorized by compartment bias of 55% as defined in C and D . Females had greater pretest locomotion than males in both the low ( E ) and high ( F ) context versions of the assay, but locomotion was unaffected by compartment bias. *p < 0.05, ****p < 0.0001 for main effects of sex in 2×2 ANOVAs.
24 Well Transwell Inserts Upper Compartment Pores, supplied by Corning Life Sciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/compartment+insert/96+well+plates/pmc09338917-45-39-41
Average 90 stars, based on 1 article reviews
24-well transwell inserts upper compartment pores - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Corning Life Sciences transwell insert costar upper compartment
A) Experimental timeline of the conditioned place preference (CPP) paradigm. B) Illustration of the CPP apparatus in the low and high context version of the apparatus. In the low context version, the walls were distinctly patterned with horizontal stripes in the “left” compartment and zig zag stripes in the “right” compartment, but the flooring was smooth in both <t>compartments.</t> In the high context version, the flooring was also distinct between compartments, with the “left” compartment altered to a textured rubber flooring to distinguish it tactilely from the “right” compartment smooth flooring. C-D) % Time spent in the left compartment of the apparatus in the low ( C ) and high ( D ) context versions of the apparatus on the pretest, when mice could freely explore both compartments of the apparatus for the first time. Individual data points are color coded to reflect categorization of compartment bias on the pretest (pink: > 55%; teal: < 45%; black: between 45% and 55% in left compartment). *p < 0.05 for unpaired t-tests between males and females; # p < 0.05, #### p < 0.0001 for one-sample t-tests within group compared to the null hypothesis mean of 50%. E-F) Pretest locomotion in females and males, subcategorized by compartment bias of 55% as defined in C and D . Females had greater pretest locomotion than males in both the low ( E ) and high ( F ) context versions of the assay, but locomotion was unaffected by compartment bias. *p < 0.05, ****p < 0.0001 for main effects of sex in 2×2 ANOVAs.
Transwell Insert Costar Upper Compartment, supplied by Corning Life Sciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/compartment+insert/transwell+compartment/pmc09102452-257-19-21
Average 90 stars, based on 1 article reviews
transwell insert costar upper compartment - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Bruker Corporation gas cell inserted into the sample compartment of a bruker vertex70 fourier transform infrared (ftir) interferometer
A) Experimental timeline of the conditioned place preference (CPP) paradigm. B) Illustration of the CPP apparatus in the low and high context version of the apparatus. In the low context version, the walls were distinctly patterned with horizontal stripes in the “left” compartment and zig zag stripes in the “right” compartment, but the flooring was smooth in both <t>compartments.</t> In the high context version, the flooring was also distinct between compartments, with the “left” compartment altered to a textured rubber flooring to distinguish it tactilely from the “right” compartment smooth flooring. C-D) % Time spent in the left compartment of the apparatus in the low ( C ) and high ( D ) context versions of the apparatus on the pretest, when mice could freely explore both compartments of the apparatus for the first time. Individual data points are color coded to reflect categorization of compartment bias on the pretest (pink: > 55%; teal: < 45%; black: between 45% and 55% in left compartment). *p < 0.05 for unpaired t-tests between males and females; # p < 0.05, #### p < 0.0001 for one-sample t-tests within group compared to the null hypothesis mean of 50%. E-F) Pretest locomotion in females and males, subcategorized by compartment bias of 55% as defined in C and D . Females had greater pretest locomotion than males in both the low ( E ) and high ( F ) context versions of the assay, but locomotion was unaffected by compartment bias. *p < 0.05, ****p < 0.0001 for main effects of sex in 2×2 ANOVAs.
Gas Cell Inserted Into The Sample Compartment Of A Bruker Vertex70 Fourier Transform Infrared (Ftir) Interferometer, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/compartment+insert/d8+advance+diffractometer/pmc08607820-131-15-18
Average 90 stars, based on 1 article reviews
gas cell inserted into the sample compartment of a bruker vertex70 fourier transform infrared (ftir) interferometer - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


A) Experimental timeline of the conditioned place preference (CPP) paradigm. B) Illustration of the CPP apparatus in the low and high context version of the apparatus. In the low context version, the walls were distinctly patterned with horizontal stripes in the “left” compartment and zig zag stripes in the “right” compartment, but the flooring was smooth in both compartments. In the high context version, the flooring was also distinct between compartments, with the “left” compartment altered to a textured rubber flooring to distinguish it tactilely from the “right” compartment smooth flooring. C-D) % Time spent in the left compartment of the apparatus in the low ( C ) and high ( D ) context versions of the apparatus on the pretest, when mice could freely explore both compartments of the apparatus for the first time. Individual data points are color coded to reflect categorization of compartment bias on the pretest (pink: > 55%; teal: < 45%; black: between 45% and 55% in left compartment). *p < 0.05 for unpaired t-tests between males and females; # p < 0.05, #### p < 0.0001 for one-sample t-tests within group compared to the null hypothesis mean of 50%. E-F) Pretest locomotion in females and males, subcategorized by compartment bias of 55% as defined in C and D . Females had greater pretest locomotion than males in both the low ( E ) and high ( F ) context versions of the assay, but locomotion was unaffected by compartment bias. *p < 0.05, ****p < 0.0001 for main effects of sex in 2×2 ANOVAs.

Journal: bioRxiv

Article Title: Morphine-context associative memory and locomotor sensitization in mice are modulated by sex and context in a dose-dependent manner

doi: 10.1101/2023.11.03.565492

Figure Lengend Snippet: A) Experimental timeline of the conditioned place preference (CPP) paradigm. B) Illustration of the CPP apparatus in the low and high context version of the apparatus. In the low context version, the walls were distinctly patterned with horizontal stripes in the “left” compartment and zig zag stripes in the “right” compartment, but the flooring was smooth in both compartments. In the high context version, the flooring was also distinct between compartments, with the “left” compartment altered to a textured rubber flooring to distinguish it tactilely from the “right” compartment smooth flooring. C-D) % Time spent in the left compartment of the apparatus in the low ( C ) and high ( D ) context versions of the apparatus on the pretest, when mice could freely explore both compartments of the apparatus for the first time. Individual data points are color coded to reflect categorization of compartment bias on the pretest (pink: > 55%; teal: < 45%; black: between 45% and 55% in left compartment). *p < 0.05 for unpaired t-tests between males and females; # p < 0.05, #### p < 0.0001 for one-sample t-tests within group compared to the null hypothesis mean of 50%. E-F) Pretest locomotion in females and males, subcategorized by compartment bias of 55% as defined in C and D . Females had greater pretest locomotion than males in both the low ( E ) and high ( F ) context versions of the assay, but locomotion was unaffected by compartment bias. *p < 0.05, ****p < 0.0001 for main effects of sex in 2×2 ANOVAs.

Article Snippet: The CPP apparatus consisted of a standard mouse arena (27.3×27.3×20.3 cm) separated into two compartments by a two chamber place preference insert with removable guillotine door (Med Associates Inc., Fairfax, VT, USA).

Techniques: Conditioned Place Preference

A-B) On the first day of conditioning (C1) in the low context ( A ) and high context ( B ) versions of the CPP assay, females displayed acute hyperlocomotion following the morphine injection on the afternoon conditioning session, regardless of whether the morphine was paired with the left or right compartment; this locomotor sensitivity was dose-dependent, as cohorts receiving higher doses of morphine displayed greater morphine-induced hyperlocomotion. Locomotion following saline injection on the morning session (6 hr earlier) was similar across morphine dose groups and paired compartment. C-D) Males displayed a similar dose-dependent hyperlocomotor response to morphine that was similar in both compartments of the apparatus in the low ( C ) and high ( D ) context assays, with no differences in saline locomotion. **p < 0.01, ****p < 0.0001 indicate main effect of morphine dose in 2×2 RM-ANOVAs; $$$ p ≤ 0.001, $$$$ p < 0.0001 indicate difference from 5 mg/kg morphine dose, ## p ≤ 0.01, ### p ≤ 0.001 indicates difference from 10 mg/kg morphine dose in post hoc t-tests between doses.

Journal: bioRxiv

Article Title: Morphine-context associative memory and locomotor sensitization in mice are modulated by sex and context in a dose-dependent manner

doi: 10.1101/2023.11.03.565492

Figure Lengend Snippet: A-B) On the first day of conditioning (C1) in the low context ( A ) and high context ( B ) versions of the CPP assay, females displayed acute hyperlocomotion following the morphine injection on the afternoon conditioning session, regardless of whether the morphine was paired with the left or right compartment; this locomotor sensitivity was dose-dependent, as cohorts receiving higher doses of morphine displayed greater morphine-induced hyperlocomotion. Locomotion following saline injection on the morning session (6 hr earlier) was similar across morphine dose groups and paired compartment. C-D) Males displayed a similar dose-dependent hyperlocomotor response to morphine that was similar in both compartments of the apparatus in the low ( C ) and high ( D ) context assays, with no differences in saline locomotion. **p < 0.01, ****p < 0.0001 indicate main effect of morphine dose in 2×2 RM-ANOVAs; $$$ p ≤ 0.001, $$$$ p < 0.0001 indicate difference from 5 mg/kg morphine dose, ## p ≤ 0.01, ### p ≤ 0.001 indicates difference from 10 mg/kg morphine dose in post hoc t-tests between doses.

Article Snippet: The CPP apparatus consisted of a standard mouse arena (27.3×27.3×20.3 cm) separated into two compartments by a two chamber place preference insert with removable guillotine door (Med Associates Inc., Fairfax, VT, USA).

Techniques: Injection, Saline