Review




Structured Review

Charles River Laboratories cell microarray
Retrogenix <t>microarray</t> screen. Expression vectors encoding >6000 human membrane proteins were arrayed on slides and overlaid with HEK293 cells for reverse transfection. AAV was added and cell-bound capsids were detected with an anti-AAV9 antibody. Bottom panel: Image from microarray screen demonstrating detection of virus spotted in gelatin (positive control) and VCAP-101 bound to cells expressing ALPL. b , Human ORFeome screen protocol. A lentiviral library containing 17,000 human ORFs was used to generate a stable HEK293T pool that was subjected to iterative rounds of transduction with VCAP-102-EGFP followed by sorting of GFP(+) cells. AAV9-mCherry was added to the third round of screening to identify EGFP(+)/mCherry(-) cells expressing a VCAP-102-specific receptor. Bottom panel: FACS gating strategy showing stepwise enrichment of permissive GFP(+) cells. c, Detection of ALPL by immunohistochemistry (IHC) in brain sections from human, African green monkey and mouse . d , Impact of ALPL depletion on VCAP-102 transduction. HeLa cells were transfected with siRNAs against ALPL and transduced with AAV9 or VCAP-102 containing a luciferase transgene. Luciferase data was normalized to VCAP-102 control siRNA (mean ± SD, n=3). e , Removal of cell surface GPI-AP proteins reduces VCAP-102 transduction. HeLa cells were treated with PI-PLC and transduced with AAV9 or VCAP-102 containing a luciferase transgene. Luciferase data (mean ± SD, n=3) is normalized to untreated controls. f , Plasma membrane localization of ALPL is necessary for VCAP-102 transduction. HEK293T cells were transfected with plasmid encoding an ALPL isoform defective for plasma membrane trafficking (ALPL-V2) and transduced with AAV9 or VCAP-102 encoding luciferase. 24h post-transduction a luciferase assay was performed. Data (mean ± SD, n=3) was normalized to vector control.
Cell Microarray, supplied by Charles River Laboratories, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cell+microarray+assay/cell+microarray/bio_rxiv__2024__03__12__584703-207-2-1
Average 90 stars, based on 1 article reviews
cell microarray - by Bioz Stars, 2026-11
90/100 stars

Images

1) Product Images from "Highly conserved brain vascular receptor ALPL mediates transport of engineered viral vectors across the blood-brain barrier"

Article Title: Highly conserved brain vascular receptor ALPL mediates transport of engineered viral vectors across the blood-brain barrier

Journal: bioRxiv

doi: 10.1101/2024.03.12.584703

Retrogenix microarray screen. Expression vectors encoding >6000 human membrane proteins were arrayed on slides and overlaid with HEK293 cells for reverse transfection. AAV was added and cell-bound capsids were detected with an anti-AAV9 antibody. Bottom panel: Image from microarray screen demonstrating detection of virus spotted in gelatin (positive control) and VCAP-101 bound to cells expressing ALPL. b , Human ORFeome screen protocol. A lentiviral library containing 17,000 human ORFs was used to generate a stable HEK293T pool that was subjected to iterative rounds of transduction with VCAP-102-EGFP followed by sorting of GFP(+) cells. AAV9-mCherry was added to the third round of screening to identify EGFP(+)/mCherry(-) cells expressing a VCAP-102-specific receptor. Bottom panel: FACS gating strategy showing stepwise enrichment of permissive GFP(+) cells. c, Detection of ALPL by immunohistochemistry (IHC) in brain sections from human, African green monkey and mouse . d , Impact of ALPL depletion on VCAP-102 transduction. HeLa cells were transfected with siRNAs against ALPL and transduced with AAV9 or VCAP-102 containing a luciferase transgene. Luciferase data was normalized to VCAP-102 control siRNA (mean ± SD, n=3). e , Removal of cell surface GPI-AP proteins reduces VCAP-102 transduction. HeLa cells were treated with PI-PLC and transduced with AAV9 or VCAP-102 containing a luciferase transgene. Luciferase data (mean ± SD, n=3) is normalized to untreated controls. f , Plasma membrane localization of ALPL is necessary for VCAP-102 transduction. HEK293T cells were transfected with plasmid encoding an ALPL isoform defective for plasma membrane trafficking (ALPL-V2) and transduced with AAV9 or VCAP-102 encoding luciferase. 24h post-transduction a luciferase assay was performed. Data (mean ± SD, n=3) was normalized to vector control.
Figure Legend Snippet: Retrogenix microarray screen. Expression vectors encoding >6000 human membrane proteins were arrayed on slides and overlaid with HEK293 cells for reverse transfection. AAV was added and cell-bound capsids were detected with an anti-AAV9 antibody. Bottom panel: Image from microarray screen demonstrating detection of virus spotted in gelatin (positive control) and VCAP-101 bound to cells expressing ALPL. b , Human ORFeome screen protocol. A lentiviral library containing 17,000 human ORFs was used to generate a stable HEK293T pool that was subjected to iterative rounds of transduction with VCAP-102-EGFP followed by sorting of GFP(+) cells. AAV9-mCherry was added to the third round of screening to identify EGFP(+)/mCherry(-) cells expressing a VCAP-102-specific receptor. Bottom panel: FACS gating strategy showing stepwise enrichment of permissive GFP(+) cells. c, Detection of ALPL by immunohistochemistry (IHC) in brain sections from human, African green monkey and mouse . d , Impact of ALPL depletion on VCAP-102 transduction. HeLa cells were transfected with siRNAs against ALPL and transduced with AAV9 or VCAP-102 containing a luciferase transgene. Luciferase data was normalized to VCAP-102 control siRNA (mean ± SD, n=3). e , Removal of cell surface GPI-AP proteins reduces VCAP-102 transduction. HeLa cells were treated with PI-PLC and transduced with AAV9 or VCAP-102 containing a luciferase transgene. Luciferase data (mean ± SD, n=3) is normalized to untreated controls. f , Plasma membrane localization of ALPL is necessary for VCAP-102 transduction. HEK293T cells were transfected with plasmid encoding an ALPL isoform defective for plasma membrane trafficking (ALPL-V2) and transduced with AAV9 or VCAP-102 encoding luciferase. 24h post-transduction a luciferase assay was performed. Data (mean ± SD, n=3) was normalized to vector control.

Techniques Used: Microarray, Expressing, Membrane, Transfection, Virus, Positive Control, Transduction, Immunohistochemistry, Luciferase, Plasmid Preparation

Related Articles

Microarray:

Article Title: Applications of Cell-Based Protein Array Technology to Preclinical Safety Assessment of Biological Products.
Article Snippet: Off-target evaluation is essential in preclinical safety assessments of novel biotherapeutics, supporting lead molecule selection, endpoint selection in toxicology studies, and regulatory requirements for first-in-human trials.. Off-target interaction of a therapeutic antibody and antibody derivatives has been historically assessed via the Tissue Cross-Reactivity (TCR) study, in which the candidate molecule is used as a reagent in immunohistochemistry (IHC) to assess binding of the candidate molecule to a panel of human tissue sections.. The TCR approach is limited by the performance of the therapeutic as an IHC reagent, which is often suboptimal to outright infeasible.

Article Title: Preclinical Evaluation of PTK7-Targeted Radionuclide Therapy
Article Snippet: Goat anti-human Alexa 488 secondary antibody was procured from Thermo Fisher Scientific (A11013, Lot 2273669, Oslo, Norway). .. Retrogenix Cell Microarray Technology (Charles River [formerly Retrogenix], UK) was used to identify the target antigen of the OI-1 antibody. ..

Article Title: A bispecific CD40 agonistic antibody allowing for antibody-peptide conjugate formation to enable cancer-specific peptide delivery, resulting in improved T proliferation and anti-tumor immunity in mice
Article Snippet: The secondary goat anti-human IgG kappa-HRP (Southern Biotech, Cat. 2060-05) was added and incubated for 1 h prior to TMB (Fisher Scientific, Cat. N301) development and stopped with 1 M H 2 SO 4 and read at 450 nm. .. For the final BiAb drug candidate, an array-bases screening for off-target binding was tested using Retrogenix Cell Microarray Technology with live and fixed cells, including 6105 full-length human plasma membrane proteins, secreted and cell surface-tethered human secreted proteins plus a further 400 human heterodimers, performed by Charles River Laboratories using 5 μg/ml of antibody. .. Potential off-target binding was tested by ELISA against baculovirus particles (BVP), similar to described , and against a panel of antigens; Cardiolipin (Sigma-Aldrich), Keyhole Limpet Haemocyanin (KLH) (Sigma-Aldrich), lipopolysaccharide (LPS) (InvivoGen), single-stranded DNA (ssDNA) and double-stranded DNA (dsDNA) from calf thymus (Sigma-Aldrich) and human insulin (Sigma-Aldrich) analogous to previous described .

Article Title: Secreted Clever-1 Modulates T Cell Responses and Impacts Cancer Immunotherapy Efficacy
Article Snippet: Primary T cell culture supernatants were analyzed for cytokine content six days after activation with Bio-Plex Pro Human Cytokine 27-Plex Assay (#M500KCAF0Y, BioRad) according to the manufacturer’s protocol. .. To discover H1 binding ligands, biotin-H1 was tested in the Retrogenix Cell Microarray assay consisting of 6449 human plasma membrane, tethered human secreted proteins (using an epitope tag and tethered single-chain variable fragment [scFv] anchor technology) and 397 heterodimer plasma membrane protein complexes (Charles River Discovery). ..

Article Title: Preclinical characterization of MTX-101: a novel bispecific CD8 Treg modulator that restores CD8 Treg functions to suppress pathogenic T cells in autoimmune diseases
Article Snippet: .. Restricted KIR binding was confirmed using the Retrogenix cell microarray platform, in which HEK cells are transfected to express individual surface targets derived from a library of plasmids encoding over 6,500 human cell surface-expressed proteins as described , followed by binding of MTX-101 or relevant single-arm controls and flow cytometry analysis. .. Restricted KIR binding was confirmed using the Retrogenix cell microarray platform, in which HEK cells are transfected to express individual surface targets derived from a library of plasmids encoding over 6,500 human cell surface-expressed proteins as described , followed by binding of MTX-101 or relevant single-arm controls and flow cytometry analysis.

Article Title: ETx-22, a Novel Nectin-4–Directed Antibody–Drug Conjugate, Demonstrates Safety and Potent Antitumor Activity in Low-Nectin-4–Expressing Tumors
Article Snippet: .. Antigen selectivity of 15A7.5 was further assessed in a human plasma membrane protein array using the Retrogenix cell microarray technology (Charles River Laboratories) against 6,226 human full-length human plasma membrane and secreted proteins. ..

Membrane:

Article Title: Applications of Cell-Based Protein Array Technology to Preclinical Safety Assessment of Biological Products.
Article Snippet: Off-target evaluation is essential in preclinical safety assessments of novel biotherapeutics, supporting lead molecule selection, endpoint selection in toxicology studies, and regulatory requirements for first-in-human trials.. Off-target interaction of a therapeutic antibody and antibody derivatives has been historically assessed via the Tissue Cross-Reactivity (TCR) study, in which the candidate molecule is used as a reagent in immunohistochemistry (IHC) to assess binding of the candidate molecule to a panel of human tissue sections.. The TCR approach is limited by the performance of the therapeutic as an IHC reagent, which is often suboptimal to outright infeasible.

Article Title: A bispecific CD40 agonistic antibody allowing for antibody-peptide conjugate formation to enable cancer-specific peptide delivery, resulting in improved T proliferation and anti-tumor immunity in mice
Article Snippet: The secondary goat anti-human IgG kappa-HRP (Southern Biotech, Cat. 2060-05) was added and incubated for 1 h prior to TMB (Fisher Scientific, Cat. N301) development and stopped with 1 M H 2 SO 4 and read at 450 nm. .. For the final BiAb drug candidate, an array-bases screening for off-target binding was tested using Retrogenix Cell Microarray Technology with live and fixed cells, including 6105 full-length human plasma membrane proteins, secreted and cell surface-tethered human secreted proteins plus a further 400 human heterodimers, performed by Charles River Laboratories using 5 μg/ml of antibody. .. Potential off-target binding was tested by ELISA against baculovirus particles (BVP), similar to described , and against a panel of antigens; Cardiolipin (Sigma-Aldrich), Keyhole Limpet Haemocyanin (KLH) (Sigma-Aldrich), lipopolysaccharide (LPS) (InvivoGen), single-stranded DNA (ssDNA) and double-stranded DNA (dsDNA) from calf thymus (Sigma-Aldrich) and human insulin (Sigma-Aldrich) analogous to previous described .

Article Title: Secreted Clever-1 Modulates T Cell Responses and Impacts Cancer Immunotherapy Efficacy
Article Snippet: Primary T cell culture supernatants were analyzed for cytokine content six days after activation with Bio-Plex Pro Human Cytokine 27-Plex Assay (#M500KCAF0Y, BioRad) according to the manufacturer’s protocol. .. To discover H1 binding ligands, biotin-H1 was tested in the Retrogenix Cell Microarray assay consisting of 6449 human plasma membrane, tethered human secreted proteins (using an epitope tag and tethered single-chain variable fragment [scFv] anchor technology) and 397 heterodimer plasma membrane protein complexes (Charles River Discovery). ..

Article Title: ETx-22, a Novel Nectin-4–Directed Antibody–Drug Conjugate, Demonstrates Safety and Potent Antitumor Activity in Low-Nectin-4–Expressing Tumors
Article Snippet: .. Antigen selectivity of 15A7.5 was further assessed in a human plasma membrane protein array using the Retrogenix cell microarray technology (Charles River Laboratories) against 6,226 human full-length human plasma membrane and secreted proteins. ..

Clinical Proteomics:

Article Title: Applications of Cell-Based Protein Array Technology to Preclinical Safety Assessment of Biological Products.
Article Snippet: Off-target evaluation is essential in preclinical safety assessments of novel biotherapeutics, supporting lead molecule selection, endpoint selection in toxicology studies, and regulatory requirements for first-in-human trials.. Off-target interaction of a therapeutic antibody and antibody derivatives has been historically assessed via the Tissue Cross-Reactivity (TCR) study, in which the candidate molecule is used as a reagent in immunohistochemistry (IHC) to assess binding of the candidate molecule to a panel of human tissue sections.. The TCR approach is limited by the performance of the therapeutic as an IHC reagent, which is often suboptimal to outright infeasible.

Article Title: A bispecific CD40 agonistic antibody allowing for antibody-peptide conjugate formation to enable cancer-specific peptide delivery, resulting in improved T proliferation and anti-tumor immunity in mice
Article Snippet: The secondary goat anti-human IgG kappa-HRP (Southern Biotech, Cat. 2060-05) was added and incubated for 1 h prior to TMB (Fisher Scientific, Cat. N301) development and stopped with 1 M H 2 SO 4 and read at 450 nm. .. For the final BiAb drug candidate, an array-bases screening for off-target binding was tested using Retrogenix Cell Microarray Technology with live and fixed cells, including 6105 full-length human plasma membrane proteins, secreted and cell surface-tethered human secreted proteins plus a further 400 human heterodimers, performed by Charles River Laboratories using 5 μg/ml of antibody. .. Potential off-target binding was tested by ELISA against baculovirus particles (BVP), similar to described , and against a panel of antigens; Cardiolipin (Sigma-Aldrich), Keyhole Limpet Haemocyanin (KLH) (Sigma-Aldrich), lipopolysaccharide (LPS) (InvivoGen), single-stranded DNA (ssDNA) and double-stranded DNA (dsDNA) from calf thymus (Sigma-Aldrich) and human insulin (Sigma-Aldrich) analogous to previous described .

Article Title: Secreted Clever-1 Modulates T Cell Responses and Impacts Cancer Immunotherapy Efficacy
Article Snippet: Primary T cell culture supernatants were analyzed for cytokine content six days after activation with Bio-Plex Pro Human Cytokine 27-Plex Assay (#M500KCAF0Y, BioRad) according to the manufacturer’s protocol. .. To discover H1 binding ligands, biotin-H1 was tested in the Retrogenix Cell Microarray assay consisting of 6449 human plasma membrane, tethered human secreted proteins (using an epitope tag and tethered single-chain variable fragment [scFv] anchor technology) and 397 heterodimer plasma membrane protein complexes (Charles River Discovery). ..

Article Title: ETx-22, a Novel Nectin-4–Directed Antibody–Drug Conjugate, Demonstrates Safety and Potent Antitumor Activity in Low-Nectin-4–Expressing Tumors
Article Snippet: .. Antigen selectivity of 15A7.5 was further assessed in a human plasma membrane protein array using the Retrogenix cell microarray technology (Charles River Laboratories) against 6,226 human full-length human plasma membrane and secreted proteins. ..

Cotransfection:

Article Title: Applications of Cell-Based Protein Array Technology to Preclinical Safety Assessment of Biological Products.
Article Snippet: Off-target evaluation is essential in preclinical safety assessments of novel biotherapeutics, supporting lead molecule selection, endpoint selection in toxicology studies, and regulatory requirements for first-in-human trials.. Off-target interaction of a therapeutic antibody and antibody derivatives has been historically assessed via the Tissue Cross-Reactivity (TCR) study, in which the candidate molecule is used as a reagent in immunohistochemistry (IHC) to assess binding of the candidate molecule to a panel of human tissue sections.. The TCR approach is limited by the performance of the therapeutic as an IHC reagent, which is often suboptimal to outright infeasible.

Transfection:

Article Title: Applications of Cell-Based Protein Array Technology to Preclinical Safety Assessment of Biological Products.
Article Snippet: Off-target evaluation is essential in preclinical safety assessments of novel biotherapeutics, supporting lead molecule selection, endpoint selection in toxicology studies, and regulatory requirements for first-in-human trials.. Off-target interaction of a therapeutic antibody and antibody derivatives has been historically assessed via the Tissue Cross-Reactivity (TCR) study, in which the candidate molecule is used as a reagent in immunohistochemistry (IHC) to assess binding of the candidate molecule to a panel of human tissue sections.. The TCR approach is limited by the performance of the therapeutic as an IHC reagent, which is often suboptimal to outright infeasible.

Article Title: Preclinical characterization of MTX-101: a novel bispecific CD8 Treg modulator that restores CD8 Treg functions to suppress pathogenic T cells in autoimmune diseases
Article Snippet: .. Restricted KIR binding was confirmed using the Retrogenix cell microarray platform, in which HEK cells are transfected to express individual surface targets derived from a library of plasmids encoding over 6,500 human cell surface-expressed proteins as described , followed by binding of MTX-101 or relevant single-arm controls and flow cytometry analysis. .. Restricted KIR binding was confirmed using the Retrogenix cell microarray platform, in which HEK cells are transfected to express individual surface targets derived from a library of plasmids encoding over 6,500 human cell surface-expressed proteins as described , followed by binding of MTX-101 or relevant single-arm controls and flow cytometry analysis.

Expressing:

Article Title: Applications of Cell-Based Protein Array Technology to Preclinical Safety Assessment of Biological Products.
Article Snippet: Off-target evaluation is essential in preclinical safety assessments of novel biotherapeutics, supporting lead molecule selection, endpoint selection in toxicology studies, and regulatory requirements for first-in-human trials.. Off-target interaction of a therapeutic antibody and antibody derivatives has been historically assessed via the Tissue Cross-Reactivity (TCR) study, in which the candidate molecule is used as a reagent in immunohistochemistry (IHC) to assess binding of the candidate molecule to a panel of human tissue sections.. The TCR approach is limited by the performance of the therapeutic as an IHC reagent, which is often suboptimal to outright infeasible.

In Vitro:

Article Title: Applications of Cell-Based Protein Array Technology to Preclinical Safety Assessment of Biological Products.
Article Snippet: Off-target evaluation is essential in preclinical safety assessments of novel biotherapeutics, supporting lead molecule selection, endpoint selection in toxicology studies, and regulatory requirements for first-in-human trials.. Off-target interaction of a therapeutic antibody and antibody derivatives has been historically assessed via the Tissue Cross-Reactivity (TCR) study, in which the candidate molecule is used as a reagent in immunohistochemistry (IHC) to assess binding of the candidate molecule to a panel of human tissue sections.. The TCR approach is limited by the performance of the therapeutic as an IHC reagent, which is often suboptimal to outright infeasible.

Binding Assay:

Article Title: Applications of Cell-Based Protein Array Technology to Preclinical Safety Assessment of Biological Products.
Article Snippet: Off-target evaluation is essential in preclinical safety assessments of novel biotherapeutics, supporting lead molecule selection, endpoint selection in toxicology studies, and regulatory requirements for first-in-human trials.. Off-target interaction of a therapeutic antibody and antibody derivatives has been historically assessed via the Tissue Cross-Reactivity (TCR) study, in which the candidate molecule is used as a reagent in immunohistochemistry (IHC) to assess binding of the candidate molecule to a panel of human tissue sections.. The TCR approach is limited by the performance of the therapeutic as an IHC reagent, which is often suboptimal to outright infeasible.

Article Title: A bispecific CD40 agonistic antibody allowing for antibody-peptide conjugate formation to enable cancer-specific peptide delivery, resulting in improved T proliferation and anti-tumor immunity in mice
Article Snippet: The secondary goat anti-human IgG kappa-HRP (Southern Biotech, Cat. 2060-05) was added and incubated for 1 h prior to TMB (Fisher Scientific, Cat. N301) development and stopped with 1 M H 2 SO 4 and read at 450 nm. .. For the final BiAb drug candidate, an array-bases screening for off-target binding was tested using Retrogenix Cell Microarray Technology with live and fixed cells, including 6105 full-length human plasma membrane proteins, secreted and cell surface-tethered human secreted proteins plus a further 400 human heterodimers, performed by Charles River Laboratories using 5 μg/ml of antibody. .. Potential off-target binding was tested by ELISA against baculovirus particles (BVP), similar to described , and against a panel of antigens; Cardiolipin (Sigma-Aldrich), Keyhole Limpet Haemocyanin (KLH) (Sigma-Aldrich), lipopolysaccharide (LPS) (InvivoGen), single-stranded DNA (ssDNA) and double-stranded DNA (dsDNA) from calf thymus (Sigma-Aldrich) and human insulin (Sigma-Aldrich) analogous to previous described .

Article Title: Secreted Clever-1 Modulates T Cell Responses and Impacts Cancer Immunotherapy Efficacy
Article Snippet: Primary T cell culture supernatants were analyzed for cytokine content six days after activation with Bio-Plex Pro Human Cytokine 27-Plex Assay (#M500KCAF0Y, BioRad) according to the manufacturer’s protocol. .. To discover H1 binding ligands, biotin-H1 was tested in the Retrogenix Cell Microarray assay consisting of 6449 human plasma membrane, tethered human secreted proteins (using an epitope tag and tethered single-chain variable fragment [scFv] anchor technology) and 397 heterodimer plasma membrane protein complexes (Charles River Discovery). ..

Article Title: Preclinical characterization of MTX-101: a novel bispecific CD8 Treg modulator that restores CD8 Treg functions to suppress pathogenic T cells in autoimmune diseases
Article Snippet: .. Restricted KIR binding was confirmed using the Retrogenix cell microarray platform, in which HEK cells are transfected to express individual surface targets derived from a library of plasmids encoding over 6,500 human cell surface-expressed proteins as described , followed by binding of MTX-101 or relevant single-arm controls and flow cytometry analysis. .. Restricted KIR binding was confirmed using the Retrogenix cell microarray platform, in which HEK cells are transfected to express individual surface targets derived from a library of plasmids encoding over 6,500 human cell surface-expressed proteins as described , followed by binding of MTX-101 or relevant single-arm controls and flow cytometry analysis.

Derivative Assay:

Article Title: Preclinical characterization of MTX-101: a novel bispecific CD8 Treg modulator that restores CD8 Treg functions to suppress pathogenic T cells in autoimmune diseases
Article Snippet: .. Restricted KIR binding was confirmed using the Retrogenix cell microarray platform, in which HEK cells are transfected to express individual surface targets derived from a library of plasmids encoding over 6,500 human cell surface-expressed proteins as described , followed by binding of MTX-101 or relevant single-arm controls and flow cytometry analysis. .. Restricted KIR binding was confirmed using the Retrogenix cell microarray platform, in which HEK cells are transfected to express individual surface targets derived from a library of plasmids encoding over 6,500 human cell surface-expressed proteins as described , followed by binding of MTX-101 or relevant single-arm controls and flow cytometry analysis.

Flow Cytometry:

Article Title: Preclinical characterization of MTX-101: a novel bispecific CD8 Treg modulator that restores CD8 Treg functions to suppress pathogenic T cells in autoimmune diseases
Article Snippet: .. Restricted KIR binding was confirmed using the Retrogenix cell microarray platform, in which HEK cells are transfected to express individual surface targets derived from a library of plasmids encoding over 6,500 human cell surface-expressed proteins as described , followed by binding of MTX-101 or relevant single-arm controls and flow cytometry analysis. .. Restricted KIR binding was confirmed using the Retrogenix cell microarray platform, in which HEK cells are transfected to express individual surface targets derived from a library of plasmids encoding over 6,500 human cell surface-expressed proteins as described , followed by binding of MTX-101 or relevant single-arm controls and flow cytometry analysis.

Protein Array:

Article Title: ETx-22, a Novel Nectin-4–Directed Antibody–Drug Conjugate, Demonstrates Safety and Potent Antitumor Activity in Low-Nectin-4–Expressing Tumors
Article Snippet: .. Antigen selectivity of 15A7.5 was further assessed in a human plasma membrane protein array using the Retrogenix cell microarray technology (Charles River Laboratories) against 6,226 human full-length human plasma membrane and secreted proteins. ..



Similar Products

86
Charles River Laboratories retrogenix cell microarray
BNT351 shows comparable target affinity to 1-18 and no off-target binding (A) Left: the binding affinity of BNT351 and 1-18 to the stabilized HIV-1 envelope protein trimer (SOSIP BG505.664 ) by SPR (mean and individual values of triplicate measurements). Also see A. Right: binding of BNT351 and 1-18 to SOSIP BG505.664 by ELISA (mean ± standard deviation of triplicate measurements). (B) BNT351’s off-target binding was assessed by Retrogenix Cell <t>Microarray</t> Technology platform. Interactions identified during the library screen with ∼6,500 human proteins are shown. Also, see . Interaction with pepsinogen C (PGC) that appeared to be specific was re-tested by flow cytometry with HEK293 cells transfected with PGC. HEK293 cells transfected with FcγRIIIa and FcεRIg were used as a positive control. Duplicate measurements are shown for flow cytometry.
Retrogenix Cell Microarray, supplied by Charles River Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cell+microarray+assay/cell+microarray+screen+technology/pmc13276592-382-1-1
Average 86 stars, based on 1 article reviews
retrogenix cell microarray - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Charles River Laboratories retrogenix cell microarray 30
BNT351 shows comparable target affinity to 1-18 and no off-target binding (A) Left: the binding affinity of BNT351 and 1-18 to the stabilized HIV-1 envelope protein trimer (SOSIP BG505.664 ) by SPR (mean and individual values of triplicate measurements). Also see A. Right: binding of BNT351 and 1-18 to SOSIP BG505.664 by ELISA (mean ± standard deviation of triplicate measurements). (B) BNT351’s off-target binding was assessed by Retrogenix Cell <t>Microarray</t> Technology platform. Interactions identified during the library screen with ∼6,500 human proteins are shown. Also, see . Interaction with pepsinogen C (PGC) that appeared to be specific was re-tested by flow cytometry with HEK293 cells transfected with PGC. HEK293 cells transfected with FcγRIIIa and FcεRIg were used as a positive control. Duplicate measurements are shown for flow cytometry.
Retrogenix Cell Microarray 30, supplied by Charles River Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cell+microarray+assay/cell+microarray+screen+technology/10__1016_slash_j__isci__2026__116022-268-1-1
Average 86 stars, based on 1 article reviews
retrogenix cell microarray 30 - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Charles River Laboratories retrogenix cell microarray technology
BNT351 shows comparable target affinity to 1-18 and no off-target binding (A) Left: the binding affinity of BNT351 and 1-18 to the stabilized HIV-1 envelope protein trimer (SOSIP BG505.664 ) by SPR (mean and individual values of triplicate measurements). Also see A. Right: binding of BNT351 and 1-18 to SOSIP BG505.664 by ELISA (mean ± standard deviation of triplicate measurements). (B) BNT351’s off-target binding was assessed by Retrogenix Cell <t>Microarray</t> Technology platform. Interactions identified during the library screen with ∼6,500 human proteins are shown. Also, see . Interaction with pepsinogen C (PGC) that appeared to be specific was re-tested by flow cytometry with HEK293 cells transfected with PGC. HEK293 cells transfected with FcγRIIIa and FcεRIg were used as a positive control. Duplicate measurements are shown for flow cytometry.
Retrogenix Cell Microarray Technology, supplied by Charles River Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cell+microarray+assay/cell+microarray+screen+technology/pmc12977278-382-14-18
Average 86 stars, based on 1 article reviews
retrogenix cell microarray technology - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Charles River Laboratories cell microarray technology screen
BNT351 shows comparable target affinity to 1-18 and no off-target binding (A) Left: the binding affinity of BNT351 and 1-18 to the stabilized HIV-1 envelope protein trimer (SOSIP BG505.664 ) by SPR (mean and individual values of triplicate measurements). Also see A. Right: binding of BNT351 and 1-18 to SOSIP BG505.664 by ELISA (mean ± standard deviation of triplicate measurements). (B) BNT351’s off-target binding was assessed by Retrogenix Cell <t>Microarray</t> Technology platform. Interactions identified during the library screen with ∼6,500 human proteins are shown. Also, see . Interaction with pepsinogen C (PGC) that appeared to be specific was re-tested by flow cytometry with HEK293 cells transfected with PGC. HEK293 cells transfected with FcγRIIIa and FcεRIg were used as a positive control. Duplicate measurements are shown for flow cytometry.
Cell Microarray Technology Screen, supplied by Charles River Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cell+microarray+assay/cell+microarray+screen+technology/pm41742895-65-13-17
Average 86 stars, based on 1 article reviews
cell microarray technology screen - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Charles River Laboratories anti ccr8 antibodies retrogenix cell microarray technology
BNT351 shows comparable target affinity to 1-18 and no off-target binding (A) Left: the binding affinity of BNT351 and 1-18 to the stabilized HIV-1 envelope protein trimer (SOSIP BG505.664 ) by SPR (mean and individual values of triplicate measurements). Also see A. Right: binding of BNT351 and 1-18 to SOSIP BG505.664 by ELISA (mean ± standard deviation of triplicate measurements). (B) BNT351’s off-target binding was assessed by Retrogenix Cell <t>Microarray</t> Technology platform. Interactions identified during the library screen with ∼6,500 human proteins are shown. Also, see . Interaction with pepsinogen C (PGC) that appeared to be specific was re-tested by flow cytometry with HEK293 cells transfected with PGC. HEK293 cells transfected with FcγRIIIa and FcεRIg were used as a positive control. Duplicate measurements are shown for flow cytometry.
Anti Ccr8 Antibodies Retrogenix Cell Microarray Technology, supplied by Charles River Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cell+microarray+assay/cell+microarray+screen+technology/10__1158_slash_1535___7163__mct___25___0367-84-5-7
Average 86 stars, based on 1 article reviews
anti ccr8 antibodies retrogenix cell microarray technology - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Charles River Laboratories retrogenix s cell microarray technology
BNT351 shows comparable target affinity to 1-18 and no off-target binding (A) Left: the binding affinity of BNT351 and 1-18 to the stabilized HIV-1 envelope protein trimer (SOSIP BG505.664 ) by SPR (mean and individual values of triplicate measurements). Also see A. Right: binding of BNT351 and 1-18 to SOSIP BG505.664 by ELISA (mean ± standard deviation of triplicate measurements). (B) BNT351’s off-target binding was assessed by Retrogenix Cell <t>Microarray</t> Technology platform. Interactions identified during the library screen with ∼6,500 human proteins are shown. Also, see . Interaction with pepsinogen C (PGC) that appeared to be specific was re-tested by flow cytometry with HEK293 cells transfected with PGC. HEK293 cells transfected with FcγRIIIa and FcεRIg were used as a positive control. Duplicate measurements are shown for flow cytometry.
Retrogenix S Cell Microarray Technology, supplied by Charles River Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cell+microarray+assay/cell+microarray+screen+technology/us12435107-399-3-3
Average 86 stars, based on 1 article reviews
retrogenix s cell microarray technology - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

Image Search Results


BNT351 shows comparable target affinity to 1-18 and no off-target binding (A) Left: the binding affinity of BNT351 and 1-18 to the stabilized HIV-1 envelope protein trimer (SOSIP BG505.664 ) by SPR (mean and individual values of triplicate measurements). Also see A. Right: binding of BNT351 and 1-18 to SOSIP BG505.664 by ELISA (mean ± standard deviation of triplicate measurements). (B) BNT351’s off-target binding was assessed by Retrogenix Cell Microarray Technology platform. Interactions identified during the library screen with ∼6,500 human proteins are shown. Also, see . Interaction with pepsinogen C (PGC) that appeared to be specific was re-tested by flow cytometry with HEK293 cells transfected with PGC. HEK293 cells transfected with FcγRIIIa and FcεRIg were used as a positive control. Duplicate measurements are shown for flow cytometry.

Journal: iScience

Article Title: Preclinical assessment of broadly neutralizing HIV-1 antibody BNT351 with optimized pharmacokinetics and potent antiviral activity

doi: 10.1016/j.isci.2026.116022

Figure Lengend Snippet: BNT351 shows comparable target affinity to 1-18 and no off-target binding (A) Left: the binding affinity of BNT351 and 1-18 to the stabilized HIV-1 envelope protein trimer (SOSIP BG505.664 ) by SPR (mean and individual values of triplicate measurements). Also see A. Right: binding of BNT351 and 1-18 to SOSIP BG505.664 by ELISA (mean ± standard deviation of triplicate measurements). (B) BNT351’s off-target binding was assessed by Retrogenix Cell Microarray Technology platform. Interactions identified during the library screen with ∼6,500 human proteins are shown. Also, see . Interaction with pepsinogen C (PGC) that appeared to be specific was re-tested by flow cytometry with HEK293 cells transfected with PGC. HEK293 cells transfected with FcγRIIIa and FcεRIg were used as a positive control. Duplicate measurements are shown for flow cytometry.

Article Snippet: The Retrogenix cell microarray was performed by Charles River Laboratories and included 6,105 full-length human proteins (plasma membrane proteins, secreted or a cell surface-tethered secreted proteins) and 400 human heterodimers.

Techniques: Binding Assay, Enzyme-linked Immunosorbent Assay, Standard Deviation, Microarray, Flow Cytometry, Transfection, Positive Control