Review



incucyte s3  (Sartorius AG)


Bioz Verified Symbol Sartorius AG is a verified supplier
Bioz Manufacturer Symbol Sartorius AG manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 99

    Structured Review

    Sartorius AG incucyte s3
    Cytotoxicity activities of TIGIT BE-NK cells in vitro . A–E, A variety of different cancer cell lines (GFP expressing or red dye labeled) were inoculated into 96-well plates in quantities of 10 4 cells/well and left for 6 hours to allow cells to attach, then 10 4 PB-NK or BE-NK cells were added, and images of the same field of view were recorded at different times. A, NSCLC cell line H1299 (GFP expressing). B , NSCLC cell line A549 (GFP expressing). C , Fibrosarcoma cell line HT-1080 (GFP expressing). D , Hepatocellular cell line Huh7 (red dye labeled). E , Hepatoma cell line PLC/PRF/5 (red dye labeled). Images recorded and data analyzed by <t>IncuCyte</t> <t>S3,</t> and data are shown as mean ± SD.
    Incucyte S3, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 99/100, based on 16346 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cell+imaging/Live+Cell+Analysis+Instruments/pmc13080321-75-6-8
    Average 99 stars, based on 16346 article reviews
    incucyte s3 - by Bioz Stars, 2026-11
    99/100 stars

    Images

    1) Product Images from "Base Editing of TIGIT Reprograms CD155 Signaling in Natural Killer Cells to Enhance Cancer Immunotherapy Efficacy"

    Article Title: Base Editing of TIGIT Reprograms CD155 Signaling in Natural Killer Cells to Enhance Cancer Immunotherapy Efficacy

    Journal: Cancer Research

    doi: 10.1158/0008-5472.CAN-25-0733

    Cytotoxicity activities of TIGIT BE-NK cells in vitro . A–E, A variety of different cancer cell lines (GFP expressing or red dye labeled) were inoculated into 96-well plates in quantities of 10 4 cells/well and left for 6 hours to allow cells to attach, then 10 4 PB-NK or BE-NK cells were added, and images of the same field of view were recorded at different times. A, NSCLC cell line H1299 (GFP expressing). B , NSCLC cell line A549 (GFP expressing). C , Fibrosarcoma cell line HT-1080 (GFP expressing). D , Hepatocellular cell line Huh7 (red dye labeled). E , Hepatoma cell line PLC/PRF/5 (red dye labeled). Images recorded and data analyzed by IncuCyte S3, and data are shown as mean ± SD.
    Figure Legend Snippet: Cytotoxicity activities of TIGIT BE-NK cells in vitro . A–E, A variety of different cancer cell lines (GFP expressing or red dye labeled) were inoculated into 96-well plates in quantities of 10 4 cells/well and left for 6 hours to allow cells to attach, then 10 4 PB-NK or BE-NK cells were added, and images of the same field of view were recorded at different times. A, NSCLC cell line H1299 (GFP expressing). B , NSCLC cell line A549 (GFP expressing). C , Fibrosarcoma cell line HT-1080 (GFP expressing). D , Hepatocellular cell line Huh7 (red dye labeled). E , Hepatoma cell line PLC/PRF/5 (red dye labeled). Images recorded and data analyzed by IncuCyte S3, and data are shown as mean ± SD.

    Techniques Used: In Vitro, Expressing, Labeling

    TIGIT BE-NK cells specifically recognized target cells in a CD155-/CD226-dependent manner. A, The mean fluorescence intensity (MFI) of CD155 on H1299, H1975, A549, and H460 (NSCLC cell line), K652 (chronic myelogenous leukemia cell line), and CEM (acute lymphoblastic leukemia cell line) was assessed by flow cytometry. B, Tumor cells and PB-NK or TIGIT BE-NK cells were inoculated into 48-well plates at a 1:1 ratio, and CD107a expression on NK cells was detected by flow cytometry 4 hours later. The increase in CD107a-positive cells in the TIGIT BE-NK group was normalized to the PB-NK group. C, Tumor cells were coincubated with PB-NK or TIGIT BE-NK cells for 24 hours at an E:T ratio of 1:1, and then NK cell–mediated lysis was evaluated by luminescent cell viability assay. E:T corresponds to E:T cells. D, The mean fluorescence intensity of CD155 on U251-MG (glioblastoma cell line), Huh7 (hepatocellular cell line), HT-1080 (fibrosarcoma cell line), PLC/PRF/5 (hepatoma cell line), BxPC-3 (pancreatic adenocarcinoma cell line), T24 (urinary bladder cancer cell line), U2OS (osteosarcoma cell line), MCF7 (breast cancer cell line), HeLa (cervical carcinoma cell line), SKOV3 (ovarian cancer cell line), HCT116 (colorectal carcinoma cell line), HGC-27 (gastric cancer cell line), KG-1A, OCI-AML3 (acute myeloid leukemia cell line), and MM.1S (multiple myeloma) was assessed by flow cytometry. E, Tumor cells and PB-NK or TIGIT BE-NK cells were inoculated into 48-well plates at a 1:1 ratio, and CD107a expression on NK cells was detected by flow cytometry 4 hours later. The increase in CD107a-positive cells in the TIGIT BE-NK group was normalized to the PB-NK group. F, The correlation analysis of the result is shown in D and E . Simple linear regression analysis. G and H, The NK cell–mediated cytotoxicity was evaluated using a luminescent cell viability assay following coincubation of A549 ( G ) or Huh7 ( H ) cells with NK cells at a 1:1 ratio for 24 hours. I and J, Cytotoxic effects of individual and combined TIGIT, CD96, and PVRIG KO in NK cells. Data recorded and analyzed by IncuCyte S3; data are shown as mean ± SD. K and L, PB-NK, TIGIT BE-NK, or TIGIT/CD226 double–KO NK cells were cocultured with A549 or Huh7 tumor cells. NK cells were harvested at 0, 2, 15, and 30 minutes after stimulation, and p44/42 MAPK (ERK1/2) and phospho-p44/42 MAPK (ERK1/2; Thr202/Tyr204) activity was assessed by Western blotting. *, P < 0.05; **, P < 0.01; ***, P < 0.001; ****, P < 0.0001; ns, nonsignificant.
    Figure Legend Snippet: TIGIT BE-NK cells specifically recognized target cells in a CD155-/CD226-dependent manner. A, The mean fluorescence intensity (MFI) of CD155 on H1299, H1975, A549, and H460 (NSCLC cell line), K652 (chronic myelogenous leukemia cell line), and CEM (acute lymphoblastic leukemia cell line) was assessed by flow cytometry. B, Tumor cells and PB-NK or TIGIT BE-NK cells were inoculated into 48-well plates at a 1:1 ratio, and CD107a expression on NK cells was detected by flow cytometry 4 hours later. The increase in CD107a-positive cells in the TIGIT BE-NK group was normalized to the PB-NK group. C, Tumor cells were coincubated with PB-NK or TIGIT BE-NK cells for 24 hours at an E:T ratio of 1:1, and then NK cell–mediated lysis was evaluated by luminescent cell viability assay. E:T corresponds to E:T cells. D, The mean fluorescence intensity of CD155 on U251-MG (glioblastoma cell line), Huh7 (hepatocellular cell line), HT-1080 (fibrosarcoma cell line), PLC/PRF/5 (hepatoma cell line), BxPC-3 (pancreatic adenocarcinoma cell line), T24 (urinary bladder cancer cell line), U2OS (osteosarcoma cell line), MCF7 (breast cancer cell line), HeLa (cervical carcinoma cell line), SKOV3 (ovarian cancer cell line), HCT116 (colorectal carcinoma cell line), HGC-27 (gastric cancer cell line), KG-1A, OCI-AML3 (acute myeloid leukemia cell line), and MM.1S (multiple myeloma) was assessed by flow cytometry. E, Tumor cells and PB-NK or TIGIT BE-NK cells were inoculated into 48-well plates at a 1:1 ratio, and CD107a expression on NK cells was detected by flow cytometry 4 hours later. The increase in CD107a-positive cells in the TIGIT BE-NK group was normalized to the PB-NK group. F, The correlation analysis of the result is shown in D and E . Simple linear regression analysis. G and H, The NK cell–mediated cytotoxicity was evaluated using a luminescent cell viability assay following coincubation of A549 ( G ) or Huh7 ( H ) cells with NK cells at a 1:1 ratio for 24 hours. I and J, Cytotoxic effects of individual and combined TIGIT, CD96, and PVRIG KO in NK cells. Data recorded and analyzed by IncuCyte S3; data are shown as mean ± SD. K and L, PB-NK, TIGIT BE-NK, or TIGIT/CD226 double–KO NK cells were cocultured with A549 or Huh7 tumor cells. NK cells were harvested at 0, 2, 15, and 30 minutes after stimulation, and p44/42 MAPK (ERK1/2) and phospho-p44/42 MAPK (ERK1/2; Thr202/Tyr204) activity was assessed by Western blotting. *, P < 0.05; **, P < 0.01; ***, P < 0.001; ****, P < 0.0001; ns, nonsignificant.

    Techniques Used: Fluorescence, Flow Cytometry, Expressing, Lysis, Cell Viability Assay, Activity Assay, Western Blot

    Related Articles

    Live Cell Imaging:

    Article Title: The optogenetic tool ASAP acutely inhibits autophagy.
    Article Snippet: .. Live-cell imaging was performed with the Incucyte S3 (Sartorius) at ×10 magnification. ..

    Article Title: Noncanonical enhancers control gene expression and cell fate in human pluripotent stem cells
    Article Snippet: The samples were imaged using a Leica Stellaris 8 confocal microscope with LAS X software and analyzed with CellProfiler 4.2.6 and ImageJ 1.54f software. .. Live-cell imaging was performed using the Sartorius Incucyte S5 system, and time-lapse images and videos were analyzed using the Sartorius Incucyte 2022B Rev2 software interface. .. Total RNA was extracted using the Monarch Total RNA Miniprep Kit (NEB, T2010S), and 1 μg of RNA was used for complementary DNA synthesis with the RevertAid First Strand cDNA Synthesis Kit (Thermo Fisher Scientific, K1622) according to the manufacturer’s protocols.

    Analysis:

    Article Title: Metabolic rewiring that protects against ferroptosis underlies resistance to CDK4/6 inhibition in prostate cancer
    Article Snippet: .. Plates were then placed in the IncuCyte live-cell analysis system (Sartorius, Australia) housed in a 37 °C, 5% CO2 incubator. ..

    Article Title: Creatine metabolism is dysregulated in necrotizing enterocolitis.
    Article Snippet: .. The plate was transferred to an Incucyte S3 Live-Cell Analysis Instrument (Sartorius) housed in a 37 °C and 5% CO2 incubator. ..

    Incubator:

    Article Title: Metabolic rewiring that protects against ferroptosis underlies resistance to CDK4/6 inhibition in prostate cancer
    Article Snippet: .. Plates were then placed in the IncuCyte live-cell analysis system (Sartorius, Australia) housed in a 37 °C, 5% CO2 incubator. ..

    Article Title: Creatine metabolism is dysregulated in necrotizing enterocolitis.
    Article Snippet: .. The plate was transferred to an Incucyte S3 Live-Cell Analysis Instrument (Sartorius) housed in a 37 °C and 5% CO2 incubator. ..

    Incubation:

    Article Title: Cilengitide limits syndromic and sporadic thoracic aortic aneurysm by targeting specific αV integrin
    Article Snippet: .. The day after, cells were washed with PBS, treated with integrin inhibitors, and incubated with a solution of Annexin V-FITC (BD Biosciences) conjugated with fluorescein isothiocyanate (FITC) or ethidium bromide (EtBr) in the Incucyte Live-Cell Analysis System (Sartorius) for 6 days. ..

    Software:

    Article Title: Noncanonical enhancers control gene expression and cell fate in human pluripotent stem cells
    Article Snippet: The samples were imaged using a Leica Stellaris 8 confocal microscope with LAS X software and analyzed with CellProfiler 4.2.6 and ImageJ 1.54f software. .. Live-cell imaging was performed using the Sartorius Incucyte S5 system, and time-lapse images and videos were analyzed using the Sartorius Incucyte 2022B Rev2 software interface. .. Total RNA was extracted using the Monarch Total RNA Miniprep Kit (NEB, T2010S), and 1 μg of RNA was used for complementary DNA synthesis with the RevertAid First Strand cDNA Synthesis Kit (Thermo Fisher Scientific, K1622) according to the manufacturer’s protocols.



    Similar Products

    97
    Beyotime live dead cell imaging kit
    Live Dead Cell Imaging Kit, supplied by Beyotime, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cell+imaging/Calcein%2FPI+Cell+Viability%2FCytotoxicity+Assay+Kit/pmc13771408-266-6-10
    Average 97 stars, based on 1 article reviews
    live dead cell imaging kit - by Bioz Stars, 2026-11
    97/100 stars
      Buy from Supplier

    99
    Danaher Inc thunder imaging system
    Thunder Imaging System, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cell+imaging/THUNDER+Imager+Live+Cell+%26+3D+Assay/pm43020779-618-6-9
    Average 99 stars, based on 1 article reviews
    thunder imaging system - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    96
    Danaher Inc imageexpress pico system
    Imageexpress Pico System, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cell+imaging/ImageXpress+Pico/pmc13764095-1073-0-4
    Average 96 stars, based on 1 article reviews
    imageexpress pico system - by Bioz Stars, 2026-11
    96/100 stars
      Buy from Supplier

    99
    Sartorius AG cell imaging
    Cell Imaging, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cell+imaging/Live+Cell+Analysis+Instruments/pm43020890-893-0-8
    Average 99 stars, based on 1 article reviews
    cell imaging - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Danaher Inc thunder microscope
    Thunder Microscope, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cell+imaging/THUNDER+Imager+Live+Cell+%26+3D+Assay/pmc13752331-663-6-8
    Average 99 stars, based on 1 article reviews
    thunder microscope - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    95
    Elabscience Biotechnology e click edu 594 cell proliferation detection kit
    E Click Edu 594 Cell Proliferation Detection Kit, supplied by Elabscience Biotechnology, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cell+imaging/E-Click+EdU+Cell+Proliferation+Imaging+Assay+Kit+(Red/pmc13764575-291-26-32
    Average 95 stars, based on 1 article reviews
    e click edu 594 cell proliferation detection kit - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    96
    Danaher Inc imagexpress pico automated cell imaging system
    Imagexpress Pico Automated Cell Imaging System, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cell+imaging/ImageXpress+Pico/pm42998987-246-22-28
    Average 96 stars, based on 1 article reviews
    imagexpress pico automated cell imaging system - by Bioz Stars, 2026-11
    96/100 stars
      Buy from Supplier

    99
    Danaher Inc 213 thunder imager 3d assay platform
    213 Thunder Imager 3d Assay Platform, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cell+imaging/THUNDER+Imager+Live+Cell+%26+3D+Assay/pm42988297-121-18-17
    Average 99 stars, based on 1 article reviews
    213 thunder imager 3d assay platform - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Danaher Inc thunder imager live cell microscope
    Thunder Imager Live Cell Microscope, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cell+imaging/THUNDER+Imager+Live+Cell+%26+3D+Assay/bio_rxiv__64898__2026__11__05__764552-182-37-36
    Average 99 stars, based on 1 article reviews
    thunder imager live cell microscope - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Danaher Inc thunder imager
    Thunder Imager, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cell+imaging/THUNDER+Imager+Live+Cell+%26+3D+Assay/bio_rxiv__64898__2026__11__04__764347-179-7-9
    Average 99 stars, based on 1 article reviews
    thunder imager - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    Image Search Results