Review



adaptive blind deconvolution in the program autoquant x3  (Meyer Instruments)

 
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Meyer Instruments adaptive blind deconvolution in the program autoquant x3
    Adaptive Blind Deconvolution In The Program Autoquant X3, supplied by Meyer Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/blind+deconvolution/autoquant+x3+software/pmc12269338-73-30-33
    Average 90 stars, based on 1 article reviews
    adaptive blind deconvolution in the program autoquant x3 - by Bioz Stars, 2026-11
    90/100 stars

    Images

    Related Articles

    other:

    Article Title: PiggyBac Transposon-Mediated, Reversible Gene Transfer in Human Embryonic Stem Cells
    Article Snippet: Open arrowheads, piggyBac inverted repeats; filled arrows, Sleeping Beauty inverted repeats; filled arrowheads, lox P sites; Ins, chicken beta-globin insulator sequence; UBC, human ubiquitin C ... table ft1 table-wrap mode=article t1 Table 1. caption a4 Inverse PCR Primer Sequences Used in This Study Fluorescence microscopy and image processing After G418 selection, eight human ES cell clones were picked and plated onto MatTek 35-mm glass bottom culture dishes (MatTek, Ashland, MA), allowed to grow for 5–7 days, and then examined under a Nikon 2000U Inverted Microscope with a 60x/NA1.45 objective lens (Nikon Inc., Melville, NY).

    Software:

    Article Title: Potential application of γ-H2AX as a biodosimetry tool for radiation triage.
    Article Snippet: Radiation triage and biological dosimetry are two initial steps in the medical management of exposed individuals following radiological accidents.. Well established biodosimetry methods such as the dicentric (DC) assay, micronucleus (MN) assay, and fluorescence in-situ hybridization (FISH) translocation assay (for residual damage) have been used for this purpose for several decades.. Recent advances in scoring methodology and networking among established laboratories have increased triage capacity; however, these methods still have limitations in analysing large sample numbers, particularly because of the 48 h minimum culture time required prior to analysis.

    Article Title: Proteomic features of gray matter layers and superficial white matter of the rhesus monkey neocortex: comparison of prefrontal area 46 and occipital area 17
    Article Snippet: .. Cropped images were then deconvolved using AutoQuant X3 software (Meyer Instruments). ..

    Article Title: Supplemental nutrients stimulate the amplification of carbapenemase-producing Klebsiella pneumoniae (CPKP) in a sink drain in vitro biofilm reactor model.
    Article Snippet: Liquid wastes (LW) disposed in hospital handwashing sinks may affect colonization of sink Ptraps by carbapenemase-producing Klebsiella pneumoniae (CPKP), causing CPKP dispersal into the patient care environment.. This study aimed to determine the effect of LW on biofilm formation and CPKP colonization in a P-Trap model (PTM).. PTMs containing polymicrobial biofilms grown in autoclaved municipal tap water (ATW) supplemented with 5% dextrose in water (D5W), nutritional shake (Shake), sugar-based soft drink (Soda), or ATW were inoculated with K. pneumoniae ST258 KPCþ (ST258) or K. pneumoniae CAV1016 (CAV1016) and sampled after 7, 14, and 21 d. Biofilm bio-volume, mean thickness, and heterotrophic plate counts were significantly reduced and roughness coefficient significantly increased by Soda compared with D5W, Shake, or ATW.

    Article Title: ?H2AX foci as a measure of DNA damage: a computational approach to automatic analysis
    Article Snippet: .. Some of these computational approaches are based on the use of the freely available or commercial image analysis software such as ImageJ [ 32 ], NIH Image [ 33 ] and its Windows counterpart Scion Image [ 34 ], MetaMorph (Molecular Devices Inc, US), HistoLab (Microvision Instruments, France), Image Pro (Media Cybernetics Inc, US), AutoQuantX (Meyer Instruments Inc, US), MetaCyte (MetaSystems GmbH, Germany) These approaches invoke computational algorithms at various stages of analysis, starting from image segmentation and focus identification and ending with calculation of numerous quantitative focus parameters, often including writing of custom macros or plug-ins for execution of specific tasks [ 35 – 42 ]. .. Some of these computational approaches are based on the use of the freely available or commercial image analysis software such as ImageJ [ 32 ], NIH Image [ 33 ] and its Windows counterpart Scion Image [ 34 ], MetaMorph (Molecular Devices Inc, US), HistoLab (Microvision Instruments, France), Image Pro (Media Cybernetics Inc, US), AutoQuantX (Meyer Instruments Inc, US), MetaCyte (MetaSystems GmbH, Germany) These approaches invoke computational algorithms at various stages of analysis, starting from image segmentation and focus identification and ending with calculation of numerous quantitative focus parameters, often including writing of custom macros or plug-ins for execution of specific tasks [ 35 – 42 ].

    Article Title: Beta-glucan is a fungal determinant for adhesion-dependent human neutrophil functions.
    Article Snippet: .. Image analysis of total fluorescence was measured with AutoQuant software (Meyer Instruments). .. Image analysis of total fluorescence was measured with AutoQuant software (Meyer Instruments).

    Fluorescence:

    Article Title: Beta-glucan is a fungal determinant for adhesion-dependent human neutrophil functions.
    Article Snippet: .. Image analysis of total fluorescence was measured with AutoQuant software (Meyer Instruments). .. Image analysis of total fluorescence was measured with AutoQuant software (Meyer Instruments).



    Similar Products

    99
    Oxford Instruments 3d blind deconvolution algorithm
    3d Blind Deconvolution Algorithm, supplied by Oxford Instruments, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/blind+deconvolution/Imaris/pmc12660997-540-7-11
    Average 99 stars, based on 1 article reviews
    3d blind deconvolution algorithm - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    90
    Meyer Instruments adaptive blind deconvolution in the program autoquant x3
    Adaptive Blind Deconvolution In The Program Autoquant X3, supplied by Meyer Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/blind+deconvolution/autoquant+x3+software/pmc12269338-73-30-33
    Average 90 stars, based on 1 article reviews
    adaptive blind deconvolution in the program autoquant x3 - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Nikon elements blind deconvolution algorithm
    Elements Blind Deconvolution Algorithm, supplied by Nikon, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/blind+deconvolution/pm40123534-97-6-5
    Average 90 stars, based on 1 article reviews
    elements blind deconvolution algorithm - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Verlag GmbH blind deconvolution
    Blind Deconvolution, supplied by Verlag GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/blind+deconvolution/blind+deconvolution/us12232809-80-20-29
    Average 90 stars, based on 1 article reviews
    blind deconvolution - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Decon Laboratories blind deconvolution
    Blind Deconvolution, supplied by Decon Laboratories, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/blind+deconvolution/blind+deconvolution/pmc11697233__41467_2024_55267_MOESM2_ESM-1-10-30
    Average 90 stars, based on 1 article reviews
    blind deconvolution - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Decon Laboratories blind deconvolution blind
    a Schematic. Left : Fluorescence microscopy volumes are collected and near-diffraction-limited images from the shallow side of each stack are synthetically degraded to resemble aberrated images deeper into the stack. A neural network (e.g., 3D RCAN) is trained to reverse this degradation given the ground truth on the shallow side of the stack, and the trained neural network (DeAbe model) subsequently applied to images throughout the stack, improving contrast and resolution. Right : More detailed view of synthetic degradation process. Zernike basis functions and associated coefficients (coeffs) are used to add random aberrations by modifying the ideal point spread function (iPSF) to generate an aberrated PSF (aPSF). Ground truth images (GT) are Fourier transformed (FT) and multiplied by the ratio of the Fourier transformed aberrated and ideal PSFs (essentially a modified optical transfer function, mOTF). Inverse Fourier transforming (IFT) the result and adding noise generates the synthetically aberrated images. See “ Methods ” for further details. OBJ: objective lens. b Simulated three-dimensional phantoms comparing maximum intensity projections of aberrated input image (left, random aberration with root mean square (RMS) wavefront distortion of 2 radians and Poisson noise added for an SNR of ~16, corresponding PSF in inset), network prediction (DeAbe) given aberrated input (middle), and ground truth (GT, right). Higher magnification views of dashed rectangular region are shown in ( c ) (maximum intensity projection) and ( d ) (single plane), additionally showing restoration given blind <t>deconvolution</t> (Blind Decon), Richardson-Lucy deconvolution with diffraction-limited PSF (RL Decon 1), Richardson-Lucy deconvolution with aberrated PSF (RL Decon 2). Yellow arrows indicate a reference structure for visual comparison. Twenty iterations were used for RL deconvolution and ten for blind deconvolution. e As in ( c , d ) but showing axial plane along dashed blue line in ( b ). f Quantitative comparisons for the restorations shown in ( b – e ) using structural similarity index (SSIM, top) and peak signal-to-noise ratio (PSNR, bottom). Means and standard deviations are shown for 100 simulations (10 independent phantom volumes, each aberrated with 10 randomly chosen aberrations). Scale bars: 5 μm ( b ) and 2.5 μm ( c–e ). See also Supplementary Figs. – .
    Blind Deconvolution Blind, supplied by Decon Laboratories, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/blind+deconvolution/blind+deconvolution/pmc11697233-37-26-29
    Average 90 stars, based on 1 article reviews
    blind deconvolution blind - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    99
    Oxford Instruments 3d blind deconvolution method
    a Schematic. Left : Fluorescence microscopy volumes are collected and near-diffraction-limited images from the shallow side of each stack are synthetically degraded to resemble aberrated images deeper into the stack. A neural network (e.g., 3D RCAN) is trained to reverse this degradation given the ground truth on the shallow side of the stack, and the trained neural network (DeAbe model) subsequently applied to images throughout the stack, improving contrast and resolution. Right : More detailed view of synthetic degradation process. Zernike basis functions and associated coefficients (coeffs) are used to add random aberrations by modifying the ideal point spread function (iPSF) to generate an aberrated PSF (aPSF). Ground truth images (GT) are Fourier transformed (FT) and multiplied by the ratio of the Fourier transformed aberrated and ideal PSFs (essentially a modified optical transfer function, mOTF). Inverse Fourier transforming (IFT) the result and adding noise generates the synthetically aberrated images. See “ Methods ” for further details. OBJ: objective lens. b Simulated three-dimensional phantoms comparing maximum intensity projections of aberrated input image (left, random aberration with root mean square (RMS) wavefront distortion of 2 radians and Poisson noise added for an SNR of ~16, corresponding PSF in inset), network prediction (DeAbe) given aberrated input (middle), and ground truth (GT, right). Higher magnification views of dashed rectangular region are shown in ( c ) (maximum intensity projection) and ( d ) (single plane), additionally showing restoration given blind <t>deconvolution</t> (Blind Decon), Richardson-Lucy deconvolution with diffraction-limited PSF (RL Decon 1), Richardson-Lucy deconvolution with aberrated PSF (RL Decon 2). Yellow arrows indicate a reference structure for visual comparison. Twenty iterations were used for RL deconvolution and ten for blind deconvolution. e As in ( c , d ) but showing axial plane along dashed blue line in ( b ). f Quantitative comparisons for the restorations shown in ( b – e ) using structural similarity index (SSIM, top) and peak signal-to-noise ratio (PSNR, bottom). Means and standard deviations are shown for 100 simulations (10 independent phantom volumes, each aberrated with 10 randomly chosen aberrations). Scale bars: 5 μm ( b ) and 2.5 μm ( c–e ). See also Supplementary Figs. – .
    3d Blind Deconvolution Method, supplied by Oxford Instruments, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/blind+deconvolution/Imaris/pm39696694-96-2-7
    Average 99 stars, based on 1 article reviews
    3d blind deconvolution method - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Nikon blind 3d deconvolution 14 landweber
    a Schematic. Left : Fluorescence microscopy volumes are collected and near-diffraction-limited images from the shallow side of each stack are synthetically degraded to resemble aberrated images deeper into the stack. A neural network (e.g., 3D RCAN) is trained to reverse this degradation given the ground truth on the shallow side of the stack, and the trained neural network (DeAbe model) subsequently applied to images throughout the stack, improving contrast and resolution. Right : More detailed view of synthetic degradation process. Zernike basis functions and associated coefficients (coeffs) are used to add random aberrations by modifying the ideal point spread function (iPSF) to generate an aberrated PSF (aPSF). Ground truth images (GT) are Fourier transformed (FT) and multiplied by the ratio of the Fourier transformed aberrated and ideal PSFs (essentially a modified optical transfer function, mOTF). Inverse Fourier transforming (IFT) the result and adding noise generates the synthetically aberrated images. See “ Methods ” for further details. OBJ: objective lens. b Simulated three-dimensional phantoms comparing maximum intensity projections of aberrated input image (left, random aberration with root mean square (RMS) wavefront distortion of 2 radians and Poisson noise added for an SNR of ~16, corresponding PSF in inset), network prediction (DeAbe) given aberrated input (middle), and ground truth (GT, right). Higher magnification views of dashed rectangular region are shown in ( c ) (maximum intensity projection) and ( d ) (single plane), additionally showing restoration given blind <t>deconvolution</t> (Blind Decon), Richardson-Lucy deconvolution with diffraction-limited PSF (RL Decon 1), Richardson-Lucy deconvolution with aberrated PSF (RL Decon 2). Yellow arrows indicate a reference structure for visual comparison. Twenty iterations were used for RL deconvolution and ten for blind deconvolution. e As in ( c , d ) but showing axial plane along dashed blue line in ( b ). f Quantitative comparisons for the restorations shown in ( b – e ) using structural similarity index (SSIM, top) and peak signal-to-noise ratio (PSNR, bottom). Means and standard deviations are shown for 100 simulations (10 independent phantom volumes, each aberrated with 10 randomly chosen aberrations). Scale bars: 5 μm ( b ) and 2.5 μm ( c–e ). See also Supplementary Figs. – .
    Blind 3d Deconvolution 14 Landweber, supplied by Nikon, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/blind+deconvolution/NIS-Elements/ppr0951772-217-14-19
    Average 99 stars, based on 1 article reviews
    blind 3d deconvolution 14 landweber - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    Image Search Results


    a Schematic. Left : Fluorescence microscopy volumes are collected and near-diffraction-limited images from the shallow side of each stack are synthetically degraded to resemble aberrated images deeper into the stack. A neural network (e.g., 3D RCAN) is trained to reverse this degradation given the ground truth on the shallow side of the stack, and the trained neural network (DeAbe model) subsequently applied to images throughout the stack, improving contrast and resolution. Right : More detailed view of synthetic degradation process. Zernike basis functions and associated coefficients (coeffs) are used to add random aberrations by modifying the ideal point spread function (iPSF) to generate an aberrated PSF (aPSF). Ground truth images (GT) are Fourier transformed (FT) and multiplied by the ratio of the Fourier transformed aberrated and ideal PSFs (essentially a modified optical transfer function, mOTF). Inverse Fourier transforming (IFT) the result and adding noise generates the synthetically aberrated images. See “ Methods ” for further details. OBJ: objective lens. b Simulated three-dimensional phantoms comparing maximum intensity projections of aberrated input image (left, random aberration with root mean square (RMS) wavefront distortion of 2 radians and Poisson noise added for an SNR of ~16, corresponding PSF in inset), network prediction (DeAbe) given aberrated input (middle), and ground truth (GT, right). Higher magnification views of dashed rectangular region are shown in ( c ) (maximum intensity projection) and ( d ) (single plane), additionally showing restoration given blind deconvolution (Blind Decon), Richardson-Lucy deconvolution with diffraction-limited PSF (RL Decon 1), Richardson-Lucy deconvolution with aberrated PSF (RL Decon 2). Yellow arrows indicate a reference structure for visual comparison. Twenty iterations were used for RL deconvolution and ten for blind deconvolution. e As in ( c , d ) but showing axial plane along dashed blue line in ( b ). f Quantitative comparisons for the restorations shown in ( b – e ) using structural similarity index (SSIM, top) and peak signal-to-noise ratio (PSNR, bottom). Means and standard deviations are shown for 100 simulations (10 independent phantom volumes, each aberrated with 10 randomly chosen aberrations). Scale bars: 5 μm ( b ) and 2.5 μm ( c–e ). See also Supplementary Figs. – .

    Journal: Nature Communications

    Article Title: Deep learning-based aberration compensation improves contrast and resolution in fluorescence microscopy

    doi: 10.1038/s41467-024-55267-x

    Figure Lengend Snippet: a Schematic. Left : Fluorescence microscopy volumes are collected and near-diffraction-limited images from the shallow side of each stack are synthetically degraded to resemble aberrated images deeper into the stack. A neural network (e.g., 3D RCAN) is trained to reverse this degradation given the ground truth on the shallow side of the stack, and the trained neural network (DeAbe model) subsequently applied to images throughout the stack, improving contrast and resolution. Right : More detailed view of synthetic degradation process. Zernike basis functions and associated coefficients (coeffs) are used to add random aberrations by modifying the ideal point spread function (iPSF) to generate an aberrated PSF (aPSF). Ground truth images (GT) are Fourier transformed (FT) and multiplied by the ratio of the Fourier transformed aberrated and ideal PSFs (essentially a modified optical transfer function, mOTF). Inverse Fourier transforming (IFT) the result and adding noise generates the synthetically aberrated images. See “ Methods ” for further details. OBJ: objective lens. b Simulated three-dimensional phantoms comparing maximum intensity projections of aberrated input image (left, random aberration with root mean square (RMS) wavefront distortion of 2 radians and Poisson noise added for an SNR of ~16, corresponding PSF in inset), network prediction (DeAbe) given aberrated input (middle), and ground truth (GT, right). Higher magnification views of dashed rectangular region are shown in ( c ) (maximum intensity projection) and ( d ) (single plane), additionally showing restoration given blind deconvolution (Blind Decon), Richardson-Lucy deconvolution with diffraction-limited PSF (RL Decon 1), Richardson-Lucy deconvolution with aberrated PSF (RL Decon 2). Yellow arrows indicate a reference structure for visual comparison. Twenty iterations were used for RL deconvolution and ten for blind deconvolution. e As in ( c , d ) but showing axial plane along dashed blue line in ( b ). f Quantitative comparisons for the restorations shown in ( b – e ) using structural similarity index (SSIM, top) and peak signal-to-noise ratio (PSNR, bottom). Means and standard deviations are shown for 100 simulations (10 independent phantom volumes, each aberrated with 10 randomly chosen aberrations). Scale bars: 5 μm ( b ) and 2.5 μm ( c–e ). See also Supplementary Figs. – .

    Article Snippet: Higher magnification views of dashed rectangular region are shown in ( c ) (maximum intensity projection) and ( d ) (single plane), additionally showing restoration given blind deconvolution (Blind Decon), Richardson-Lucy deconvolution with diffraction-limited PSF (RL Decon 1), Richardson-Lucy deconvolution with aberrated PSF (RL Decon 2).

    Techniques: Fluorescence, Microscopy, Transformation Assay, Modification, Comparison

    a Live C. elegans embryos expressing a pan-nuclear GFP histone marker were imaged with light sheet microscopy ( i , left column) and the raw data processed with Richardson-Lucy deconvolution ( ii , 10 iterations, middle column) or with a trained DeAbe model ( iii , right column). First two rows show single planes 20.0 and 27.7 μm into the sample, third row shows axial view. Comparative line profiles through blue, yellow, and green lines are shown in insets, comparing ability to discriminate nuclei. Red arrow highlights nuclei for visual comparison. See also Supplementary Movie . b NK-92 cells stained with Alexa Fluor 555 wheat germ agglutinin and embedded in collagen matrices were fixed and imaged with instant SIM, a super-resolution imaging technique. Left: raw data, right: after application of DeAbe and deconvolution (DeAbe + , 20 iterations Richardson-Lucy). Lateral maximum intensity projections (MIP, top) or single axial planes (bottom) are shown in ( b ), and ( c , d ) show higher magnification views corresponding to green ( c ) or blue ( d ) dashed rectangular regions in ( b ). Colored arrows in ( c, d ) highlight fine features obscured in the raw data and better revealed in the DeAbe+ reconstructions. See also Supplementary Movie , Supplementary Fig. . e Live cardiac tissue containing cardiomyocytes expressing Tomm20-GFP was imaged with two photon microscopy. Raw data (left) are compared with DeAbe prediction (right) at indicated depths, with insets showing corresponding Fourier transform magnitudes. Blue circles in Fourier insets in ( e ) indicate 1/300 nm −1 spatial frequency just beyond resolution limit. See also Supplementary Movie . f Higher magnification views of white dashed rectangular region in ( e ), emphasizing recovery of mitochondrial boundaries by DeAbe model. See also Supplementary Fig. , Supplementary Movie . Scale bars: 10 μm ( a, e ); 5 μm ( b, f ); 2 μm ( c, d ); ( e ) diameter of Fourier circle: 300 nm −1 . Data shown are representative samples from N = 3 experiments.

    Journal: Nature Communications

    Article Title: Deep learning-based aberration compensation improves contrast and resolution in fluorescence microscopy

    doi: 10.1038/s41467-024-55267-x

    Figure Lengend Snippet: a Live C. elegans embryos expressing a pan-nuclear GFP histone marker were imaged with light sheet microscopy ( i , left column) and the raw data processed with Richardson-Lucy deconvolution ( ii , 10 iterations, middle column) or with a trained DeAbe model ( iii , right column). First two rows show single planes 20.0 and 27.7 μm into the sample, third row shows axial view. Comparative line profiles through blue, yellow, and green lines are shown in insets, comparing ability to discriminate nuclei. Red arrow highlights nuclei for visual comparison. See also Supplementary Movie . b NK-92 cells stained with Alexa Fluor 555 wheat germ agglutinin and embedded in collagen matrices were fixed and imaged with instant SIM, a super-resolution imaging technique. Left: raw data, right: after application of DeAbe and deconvolution (DeAbe + , 20 iterations Richardson-Lucy). Lateral maximum intensity projections (MIP, top) or single axial planes (bottom) are shown in ( b ), and ( c , d ) show higher magnification views corresponding to green ( c ) or blue ( d ) dashed rectangular regions in ( b ). Colored arrows in ( c, d ) highlight fine features obscured in the raw data and better revealed in the DeAbe+ reconstructions. See also Supplementary Movie , Supplementary Fig. . e Live cardiac tissue containing cardiomyocytes expressing Tomm20-GFP was imaged with two photon microscopy. Raw data (left) are compared with DeAbe prediction (right) at indicated depths, with insets showing corresponding Fourier transform magnitudes. Blue circles in Fourier insets in ( e ) indicate 1/300 nm −1 spatial frequency just beyond resolution limit. See also Supplementary Movie . f Higher magnification views of white dashed rectangular region in ( e ), emphasizing recovery of mitochondrial boundaries by DeAbe model. See also Supplementary Fig. , Supplementary Movie . Scale bars: 10 μm ( a, e ); 5 μm ( b, f ); 2 μm ( c, d ); ( e ) diameter of Fourier circle: 300 nm −1 . Data shown are representative samples from N = 3 experiments.

    Article Snippet: Higher magnification views of dashed rectangular region are shown in ( c ) (maximum intensity projection) and ( d ) (single plane), additionally showing restoration given blind deconvolution (Blind Decon), Richardson-Lucy deconvolution with diffraction-limited PSF (RL Decon 1), Richardson-Lucy deconvolution with aberrated PSF (RL Decon 2).

    Techniques: Expressing, Marker, Microscopy, Comparison, Staining, Imaging