Review




Structured Review

Biacore biosensor technology
Biosensor Technology, supplied by Biacore, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/biosensor/biosensor+system/us12655210-402-21-26
Average 86 stars, based on 1 article reviews
biosensor technology - by Bioz Stars, 2026-11
86/100 stars

Images

Related Articles

SPR Assay:

Article Title: Treatment of PD-L1-positive melanoma using an anti-PD-1 antibody
Article Snippet: .. No. 8,008,449 has been demonstrated to exhibit one or more of the following characteristics: (a) binds to human PD-1 with a KD of 1×10−7 M or less, as determined by surface plasmon resonance using a Biacore biosensor system; (b) does not substantially bind to human CD28, CTLA-4 or ICOS; (c) increases T-cell proliferation in a Mixed Lymphocyte Reaction (MLR) assay; (d) increases interferon-γ production in an MLR assay; (e) increases IL-2 secretion in an MLR assay; (f) binds to human PD-1 and cynomolgus monkey PD-1; (g) inhibits the binding of PD-L1 and/or PD-L2 to PD-1; (h) stimulates antigen-specific memory responses; (i) stimulates antibody responses; and (j) inhibits tumor cell growth in vivo. ..

Article Title: DNA Origami and Their Application in Biosensors
Article Snippet: 1984 , First mediated amperometric biosensor was created , Used oxidative and reductive reactions to measure current that has been generated [ ]. . .. 1990 , The first commercial SPR biosensor , This was created by a company known as Pharmacia Biacore, which determined molecules’ characteristics through affinity and kinetics [ ]. . .. 1992 , The first commercial lab-on-a-chip blood biosensor called i-STAT , This was created by a company named Abbott Laboratories, which provided rapid results within minutes, whilst also being a handheld system [ ]. .

Article Title: Cancer immunotherapy by disrupting PD-1/PD-L1 signaling
Article Snippet: Anti-PD-1 Antibodies of the Invention Each of the anti-PD-1 HuMAbs disclosed in U.S. Pat. .. No. 8,008,449 has been demonstrated to exhibit one or more of the following characteristics: (a) binds to human PD-1 with a KD of 1×10−7 M or less, as determined by surface plasmon resonance using a BIACORE biosensor system; (b) does not substantially bind to human CD28, CTLA-4 or ICOS; (c) increases T-cell proliferation in a Mixed Lymphocyte Reaction (MLR) assay; (d) increases interferon-7 production in an MLR assay; (e) increases IL-2 secretion in an MLR assay; (f) binds to human PD-1 and cynomolgus monkey PD-1; (g) inhibits the binding of PD-L1 and/or PD-L2 to PD-1; (h) stimulates antigen-specific memory responses; (i) stimulates Ab responses; and (j) inhibits tumor cell growth in vivo. ..

Article Title: CLDN18.2 binding molecule
Article Snippet: .. A preferred method for determining the KD value of an antibody is by using surface plasmon resonance, preferably using a biosensor system such as a Biacore system. ..

Article Title: Combination of LILRB1/2 pathway inhibitors and PD-1 pathway inhibitors
Article Snippet: One exemplary method for measuring binding affinity (KD) value is surface plasmon resonance (SPR), typically using a biosensor system such as a BIACORE system. .. SPR refers to an optical phenomenon that allows for the analysis of real-time biospecific interactions by detection of alterations in protein concentrations within a biosensor matrix, for example using the BIACORE system. .. BIAcore kinetic analysis comprises analyzing the binding and dissociation of an antigen from a chip with an immobilized molecule (e.g., a molecule comprising an antigen-binding domain), on their surface; or the dissociation of an antibody, or antigen-binding fragment thereof, from a chip with an immobilized antigen.

Mlr Assay:

Article Title: Treatment of PD-L1-positive melanoma using an anti-PD-1 antibody
Article Snippet: .. No. 8,008,449 has been demonstrated to exhibit one or more of the following characteristics: (a) binds to human PD-1 with a KD of 1×10−7 M or less, as determined by surface plasmon resonance using a Biacore biosensor system; (b) does not substantially bind to human CD28, CTLA-4 or ICOS; (c) increases T-cell proliferation in a Mixed Lymphocyte Reaction (MLR) assay; (d) increases interferon-γ production in an MLR assay; (e) increases IL-2 secretion in an MLR assay; (f) binds to human PD-1 and cynomolgus monkey PD-1; (g) inhibits the binding of PD-L1 and/or PD-L2 to PD-1; (h) stimulates antigen-specific memory responses; (i) stimulates antibody responses; and (j) inhibits tumor cell growth in vivo. ..

Article Title: Cancer immunotherapy by disrupting PD-1/PD-L1 signaling
Article Snippet: Anti-PD-1 Antibodies of the Invention Each of the anti-PD-1 HuMAbs disclosed in U.S. Pat. .. No. 8,008,449 has been demonstrated to exhibit one or more of the following characteristics: (a) binds to human PD-1 with a KD of 1×10−7 M or less, as determined by surface plasmon resonance using a BIACORE biosensor system; (b) does not substantially bind to human CD28, CTLA-4 or ICOS; (c) increases T-cell proliferation in a Mixed Lymphocyte Reaction (MLR) assay; (d) increases interferon-7 production in an MLR assay; (e) increases IL-2 secretion in an MLR assay; (f) binds to human PD-1 and cynomolgus monkey PD-1; (g) inhibits the binding of PD-L1 and/or PD-L2 to PD-1; (h) stimulates antigen-specific memory responses; (i) stimulates Ab responses; and (j) inhibits tumor cell growth in vivo. ..

Binding Assay:

Article Title: Treatment of PD-L1-positive melanoma using an anti-PD-1 antibody
Article Snippet: .. No. 8,008,449 has been demonstrated to exhibit one or more of the following characteristics: (a) binds to human PD-1 with a KD of 1×10−7 M or less, as determined by surface plasmon resonance using a Biacore biosensor system; (b) does not substantially bind to human CD28, CTLA-4 or ICOS; (c) increases T-cell proliferation in a Mixed Lymphocyte Reaction (MLR) assay; (d) increases interferon-γ production in an MLR assay; (e) increases IL-2 secretion in an MLR assay; (f) binds to human PD-1 and cynomolgus monkey PD-1; (g) inhibits the binding of PD-L1 and/or PD-L2 to PD-1; (h) stimulates antigen-specific memory responses; (i) stimulates antibody responses; and (j) inhibits tumor cell growth in vivo. ..

Article Title: Anti-hemojuvelin (HJV) antibodies for treating anemia of chronic disease
Article Snippet: The affinity and binding kinetics of the anti-HJV antibody can be tested using any suitable method including but not limited to biosensor technology (e.g., OCTET or BIACORE). .. The affinity and binding kinetics of the anti-HJV antibody can be tested using any suitable method including but not limited to biosensor technology (e.g., OCTET or BIACORE). ..

Article Title: Cancer immunotherapy by disrupting PD-1/PD-L1 signaling
Article Snippet: Anti-PD-1 Antibodies of the Invention Each of the anti-PD-1 HuMAbs disclosed in U.S. Pat. .. No. 8,008,449 has been demonstrated to exhibit one or more of the following characteristics: (a) binds to human PD-1 with a KD of 1×10−7 M or less, as determined by surface plasmon resonance using a BIACORE biosensor system; (b) does not substantially bind to human CD28, CTLA-4 or ICOS; (c) increases T-cell proliferation in a Mixed Lymphocyte Reaction (MLR) assay; (d) increases interferon-7 production in an MLR assay; (e) increases IL-2 secretion in an MLR assay; (f) binds to human PD-1 and cynomolgus monkey PD-1; (g) inhibits the binding of PD-L1 and/or PD-L2 to PD-1; (h) stimulates antigen-specific memory responses; (i) stimulates Ab responses; and (j) inhibits tumor cell growth in vivo. ..

Article Title: CD33 antibodies
Article Snippet: .. The affinity and binding kinetics of the anti-CD33 antibody can be tested using any method known in the art including but not limited to biosensor technology (e.g., OCTET or BIACORE). .. The affinity and binding kinetics of the anti-CD33 antibody can be tested using any method known in the art including but not limited to biosensor technology (e.g., OCTET or BIACORE).

Article Title: Anti-transferrin receptor (TfR) antibody and uses thereof
Article Snippet: .. The affinity and binding kinetics of the anti-TfR antibody can be tested using any suitable method including but not limited to biosensor technology (e.g., OCTET or BIACORE). ..

In Vivo:

Article Title: Treatment of PD-L1-positive melanoma using an anti-PD-1 antibody
Article Snippet: .. No. 8,008,449 has been demonstrated to exhibit one or more of the following characteristics: (a) binds to human PD-1 with a KD of 1×10−7 M or less, as determined by surface plasmon resonance using a Biacore biosensor system; (b) does not substantially bind to human CD28, CTLA-4 or ICOS; (c) increases T-cell proliferation in a Mixed Lymphocyte Reaction (MLR) assay; (d) increases interferon-γ production in an MLR assay; (e) increases IL-2 secretion in an MLR assay; (f) binds to human PD-1 and cynomolgus monkey PD-1; (g) inhibits the binding of PD-L1 and/or PD-L2 to PD-1; (h) stimulates antigen-specific memory responses; (i) stimulates antibody responses; and (j) inhibits tumor cell growth in vivo. ..

Article Title: Cancer immunotherapy by disrupting PD-1/PD-L1 signaling
Article Snippet: Anti-PD-1 Antibodies of the Invention Each of the anti-PD-1 HuMAbs disclosed in U.S. Pat. .. No. 8,008,449 has been demonstrated to exhibit one or more of the following characteristics: (a) binds to human PD-1 with a KD of 1×10−7 M or less, as determined by surface plasmon resonance using a BIACORE biosensor system; (b) does not substantially bind to human CD28, CTLA-4 or ICOS; (c) increases T-cell proliferation in a Mixed Lymphocyte Reaction (MLR) assay; (d) increases interferon-7 production in an MLR assay; (e) increases IL-2 secretion in an MLR assay; (f) binds to human PD-1 and cynomolgus monkey PD-1; (g) inhibits the binding of PD-L1 and/or PD-L2 to PD-1; (h) stimulates antigen-specific memory responses; (i) stimulates Ab responses; and (j) inhibits tumor cell growth in vivo. ..

Affinity Constant:

Article Title: CLDN18.2 binding molecule
Article Snippet: .. A preferred method for determining the KD value of an antibody is by using surface plasmon resonance, preferably using a biosensor system such as a Biacore system. ..

Analysis:

Article Title: Combination of LILRB1/2 pathway inhibitors and PD-1 pathway inhibitors
Article Snippet: One exemplary method for measuring binding affinity (KD) value is surface plasmon resonance (SPR), typically using a biosensor system such as a BIACORE system. .. SPR refers to an optical phenomenon that allows for the analysis of real-time biospecific interactions by detection of alterations in protein concentrations within a biosensor matrix, for example using the BIACORE system. .. BIAcore kinetic analysis comprises analyzing the binding and dissociation of an antigen from a chip with an immobilized molecule (e.g., a molecule comprising an antigen-binding domain), on their surface; or the dissociation of an antibody, or antigen-binding fragment thereof, from a chip with an immobilized antigen.



Similar Products

97
Sartorius AG ni nta biosensors
Ni Nta Biosensors, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/biosensor/Octet+Ni-NTA+(NTA)+Biosensors/pmc13782623-111-5-8
Average 97 stars, based on 1 article reviews
ni nta biosensors - by Bioz Stars, 2026-11
97/100 stars
  Buy from Supplier

99
Cytiva Europe biacore t200 biosensor instrument
Biacore T200 Biosensor Instrument, supplied by Cytiva Europe, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/biosensor/Biacore+T200+SPR+system/pmc13774862-53-19-23
Average 99 stars, based on 1 article reviews
biacore t200 biosensor instrument - by Bioz Stars, 2026-11
99/100 stars
  Buy from Supplier

99
Cytiva Europe biacore 200 biosensor instrument
Biacore 200 Biosensor Instrument, supplied by Cytiva Europe, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/biosensor/Biacore/pm43042550-56-23-27
Average 99 stars, based on 1 article reviews
biacore 200 biosensor instrument - by Bioz Stars, 2026-11
99/100 stars
  Buy from Supplier

98
Sartorius AG baseline measurement
Baseline Measurement, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/biosensor/Octet+Streptavidin+(SA)+Biosensor/pm43035844-72-15-27
Average 98 stars, based on 1 article reviews
baseline measurement - by Bioz Stars, 2026-11
98/100 stars
  Buy from Supplier

98
Cytiva Europe cm5 biosensor
Cm5 Biosensor, supplied by Cytiva Europe, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/biosensor/Sensor+Chip+CM5/pm43035499-496-11-13
Average 98 stars, based on 1 article reviews
cm5 biosensor - by Bioz Stars, 2026-11
98/100 stars
  Buy from Supplier

96
Sartorius AG high precision streptavidin sax biosensors
High Precision Streptavidin Sax Biosensors, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/biosensor/Octet+High+Precision+Streptavidin+(SAX)+Biosensors/pm43025600-294-6-11
Average 96 stars, based on 1 article reviews
high precision streptavidin sax biosensors - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

94
Sartorius AG mabs
Mabs, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/biosensor/Octet+Protein+G+(ProG)+Biosensors/pm43025674-117-2-9
Average 94 stars, based on 1 article reviews
mabs - by Bioz Stars, 2026-11
94/100 stars
  Buy from Supplier

99
Sartorius AG octet anti human igg fc capture ahc biosensors
A. anti-CD36 mAbs from cell selection hits or commercial clones, or isotype controls were captured on <t>anti-human</t> Fc BLI sensors, then sequentially incubated with increasing concentrations of recombinant human or mouse CD36 extracellular domain with a C-terminal avi-tag. Mouse and human CD36 binding affinities and k on / k off rates are shown. In B, profiles are shown for antibodies and subsequently oxLDL binding to immobilized biotinylated human CD36 protein on streptavidin biosensors. BLI sensors loaded with hCD36 were incubated with anti-CD36 antibodies or matched isotype controls, followed by incubation in oxLDL, to test for antibody-mediated competition for the oxLDL binding site on CD36. C. Magnification of oxLDL association/dissociation steps, vertically aligned at the start of oxLDL binding. Immobilized CD36 pre-treated with non-binding mAbs showed binding of soluble oxLDL, whereas CD36 pre-coated with anti-CD36 mAbs blocked oxLDL binding. D. Infographic showing high-content imaging oxLDL cellular uptake assay. CHO-K1 parental cells and cells overexpressing full-length CD36 were incubated for 4 h with 50 μg/mL DiI-oxLDL in the presence of isotype and anti-CD36 IgGs. Representative overexposed 10X-magnified fluorescence images of DiI-oxLDL-incubated cells shows pre-treated or untreated with Macro0579 (50 nM). E-G. Total spot area of DiI-oxLDL in response to titrated IgG1 concentrations in parental CHO (E), mouse-CD36 (F) and (G) human-CD36 overexpressing CHO cells. Minimal uptake is observed in parental CHO cells whereas robust inhibition of uptake is seen in CD36-overexpressing cells blocked with increasing doses of anti-CD36 IgG1.
Octet Anti Human Igg Fc Capture Ahc Biosensors, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/biosensor/Octet/pmc13759077-87-14-22
Average 99 stars, based on 1 article reviews
octet anti human igg fc capture ahc biosensors - by Bioz Stars, 2026-11
99/100 stars
  Buy from Supplier

97
Sartorius AG iggs
A. Cell phenotypic selections for <t>IgGs</t> targeting suppressive macrophages were performed on human macrophages (unstimulated M0, LPS stimulated, IFN-γ + LPS stimulated (M1), or IL-4 + LPS stimulated (M2)) using a synthetic scFv library (REF library). After two rounds of selections, the scFv from the eluted phage were converted into huIgG1TM. B. A high-throughput binding screening was performed on each of the induced macrophage populations by mirrorball TM and high-content imaging. Two functional screens measured the expression of CXCL10 and CD80 genes in LPS-stimulated macrophages treated with mAbs for 48h. C. Expression of CXCL10 or CD80 normalized to GAPDH housekeeper gene was quantified in 6 human donors. D. Three functional hits demonstrating binding to <t>CD36-transfected</t> 293FT cells as assessed by mirrorball TM . E. Log-normalized CD36 expression from single-cell RNAseq analysis of human NSCLC (n = 5) and (F) melanoma patients (n = 25) . Whiskers represent the min-max values. G. CD36 expression on tumor- vs spleen-infiltrated CD11b+ myeloid cells in MC38 (n = 6) and B16F10 (n = 8) subcutaneous tumor-bearing mice, as assessed by flow cytometry. Tumors were analysed 14 days post-implantation of tumor cells and expression was compared to isotype control antibody (dashed lines). P-value represents an unpaired T-test result.
Iggs, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/biosensor/Octet+Anti-Human+Fc+Capture+(AHC)+Biosensors/pmc13759077-87-6-22
Average 97 stars, based on 1 article reviews
iggs - by Bioz Stars, 2026-11
97/100 stars
  Buy from Supplier

95
Sartorius AG high precision streptavidin sax2 biosensors
A. Cell phenotypic selections for <t>IgGs</t> targeting suppressive macrophages were performed on human macrophages (unstimulated M0, LPS stimulated, IFN-γ + LPS stimulated (M1), or IL-4 + LPS stimulated (M2)) using a synthetic scFv library (REF library). After two rounds of selections, the scFv from the eluted phage were converted into huIgG1TM. B. A high-throughput binding screening was performed on each of the induced macrophage populations by mirrorball TM and high-content imaging. Two functional screens measured the expression of CXCL10 and CD80 genes in LPS-stimulated macrophages treated with mAbs for 48h. C. Expression of CXCL10 or CD80 normalized to GAPDH housekeeper gene was quantified in 6 human donors. D. Three functional hits demonstrating binding to <t>CD36-transfected</t> 293FT cells as assessed by mirrorball TM . E. Log-normalized CD36 expression from single-cell RNAseq analysis of human NSCLC (n = 5) and (F) melanoma patients (n = 25) . Whiskers represent the min-max values. G. CD36 expression on tumor- vs spleen-infiltrated CD11b+ myeloid cells in MC38 (n = 6) and B16F10 (n = 8) subcutaneous tumor-bearing mice, as assessed by flow cytometry. Tumors were analysed 14 days post-implantation of tumor cells and expression was compared to isotype control antibody (dashed lines). P-value represents an unpaired T-test result.
High Precision Streptavidin Sax2 Biosensors, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/biosensor/Octet+High+Precision+Streptavidin+2%2E0+(SAX2)+Biosensors/pmc13759077-92-10-16
Average 95 stars, based on 1 article reviews
high precision streptavidin sax2 biosensors - by Bioz Stars, 2026-11
95/100 stars
  Buy from Supplier

Image Search Results


A. anti-CD36 mAbs from cell selection hits or commercial clones, or isotype controls were captured on anti-human Fc BLI sensors, then sequentially incubated with increasing concentrations of recombinant human or mouse CD36 extracellular domain with a C-terminal avi-tag. Mouse and human CD36 binding affinities and k on / k off rates are shown. In B, profiles are shown for antibodies and subsequently oxLDL binding to immobilized biotinylated human CD36 protein on streptavidin biosensors. BLI sensors loaded with hCD36 were incubated with anti-CD36 antibodies or matched isotype controls, followed by incubation in oxLDL, to test for antibody-mediated competition for the oxLDL binding site on CD36. C. Magnification of oxLDL association/dissociation steps, vertically aligned at the start of oxLDL binding. Immobilized CD36 pre-treated with non-binding mAbs showed binding of soluble oxLDL, whereas CD36 pre-coated with anti-CD36 mAbs blocked oxLDL binding. D. Infographic showing high-content imaging oxLDL cellular uptake assay. CHO-K1 parental cells and cells overexpressing full-length CD36 were incubated for 4 h with 50 μg/mL DiI-oxLDL in the presence of isotype and anti-CD36 IgGs. Representative overexposed 10X-magnified fluorescence images of DiI-oxLDL-incubated cells shows pre-treated or untreated with Macro0579 (50 nM). E-G. Total spot area of DiI-oxLDL in response to titrated IgG1 concentrations in parental CHO (E), mouse-CD36 (F) and (G) human-CD36 overexpressing CHO cells. Minimal uptake is observed in parental CHO cells whereas robust inhibition of uptake is seen in CD36-overexpressing cells blocked with increasing doses of anti-CD36 IgG1.

Journal: PLOS One

Article Title: Minimal functional activity and presence of an antigen sink limit CD36 blockade as a macrophage-targeted cancer immunotherapy

doi: 10.1371/journal.pone.0362100

Figure Lengend Snippet: A. anti-CD36 mAbs from cell selection hits or commercial clones, or isotype controls were captured on anti-human Fc BLI sensors, then sequentially incubated with increasing concentrations of recombinant human or mouse CD36 extracellular domain with a C-terminal avi-tag. Mouse and human CD36 binding affinities and k on / k off rates are shown. In B, profiles are shown for antibodies and subsequently oxLDL binding to immobilized biotinylated human CD36 protein on streptavidin biosensors. BLI sensors loaded with hCD36 were incubated with anti-CD36 antibodies or matched isotype controls, followed by incubation in oxLDL, to test for antibody-mediated competition for the oxLDL binding site on CD36. C. Magnification of oxLDL association/dissociation steps, vertically aligned at the start of oxLDL binding. Immobilized CD36 pre-treated with non-binding mAbs showed binding of soluble oxLDL, whereas CD36 pre-coated with anti-CD36 mAbs blocked oxLDL binding. D. Infographic showing high-content imaging oxLDL cellular uptake assay. CHO-K1 parental cells and cells overexpressing full-length CD36 were incubated for 4 h with 50 μg/mL DiI-oxLDL in the presence of isotype and anti-CD36 IgGs. Representative overexposed 10X-magnified fluorescence images of DiI-oxLDL-incubated cells shows pre-treated or untreated with Macro0579 (50 nM). E-G. Total spot area of DiI-oxLDL in response to titrated IgG1 concentrations in parental CHO (E), mouse-CD36 (F) and (G) human-CD36 overexpressing CHO cells. Minimal uptake is observed in parental CHO cells whereas robust inhibition of uptake is seen in CD36-overexpressing cells blocked with increasing doses of anti-CD36 IgG1.

Article Snippet: Assays to test the affinity of IgGs for human CD36 were set up using OCTET anti-human IgG Fc capture (AHC) biosensors (18–5060; Sartorius) according to the manufacturer’s instructions.

Techniques: Selection, Clone Assay, Incubation, Recombinant, Binding Assay, High Content Screening, Fluorescence, Inhibition, Binding Curves

A. Cell phenotypic selections for IgGs targeting suppressive macrophages were performed on human macrophages (unstimulated M0, LPS stimulated, IFN-γ + LPS stimulated (M1), or IL-4 + LPS stimulated (M2)) using a synthetic scFv library (REF library). After two rounds of selections, the scFv from the eluted phage were converted into huIgG1TM. B. A high-throughput binding screening was performed on each of the induced macrophage populations by mirrorball TM and high-content imaging. Two functional screens measured the expression of CXCL10 and CD80 genes in LPS-stimulated macrophages treated with mAbs for 48h. C. Expression of CXCL10 or CD80 normalized to GAPDH housekeeper gene was quantified in 6 human donors. D. Three functional hits demonstrating binding to CD36-transfected 293FT cells as assessed by mirrorball TM . E. Log-normalized CD36 expression from single-cell RNAseq analysis of human NSCLC (n = 5) and (F) melanoma patients (n = 25) . Whiskers represent the min-max values. G. CD36 expression on tumor- vs spleen-infiltrated CD11b+ myeloid cells in MC38 (n = 6) and B16F10 (n = 8) subcutaneous tumor-bearing mice, as assessed by flow cytometry. Tumors were analysed 14 days post-implantation of tumor cells and expression was compared to isotype control antibody (dashed lines). P-value represents an unpaired T-test result.

Journal: PLOS One

Article Title: Minimal functional activity and presence of an antigen sink limit CD36 blockade as a macrophage-targeted cancer immunotherapy

doi: 10.1371/journal.pone.0362100

Figure Lengend Snippet: A. Cell phenotypic selections for IgGs targeting suppressive macrophages were performed on human macrophages (unstimulated M0, LPS stimulated, IFN-γ + LPS stimulated (M1), or IL-4 + LPS stimulated (M2)) using a synthetic scFv library (REF library). After two rounds of selections, the scFv from the eluted phage were converted into huIgG1TM. B. A high-throughput binding screening was performed on each of the induced macrophage populations by mirrorball TM and high-content imaging. Two functional screens measured the expression of CXCL10 and CD80 genes in LPS-stimulated macrophages treated with mAbs for 48h. C. Expression of CXCL10 or CD80 normalized to GAPDH housekeeper gene was quantified in 6 human donors. D. Three functional hits demonstrating binding to CD36-transfected 293FT cells as assessed by mirrorball TM . E. Log-normalized CD36 expression from single-cell RNAseq analysis of human NSCLC (n = 5) and (F) melanoma patients (n = 25) . Whiskers represent the min-max values. G. CD36 expression on tumor- vs spleen-infiltrated CD11b+ myeloid cells in MC38 (n = 6) and B16F10 (n = 8) subcutaneous tumor-bearing mice, as assessed by flow cytometry. Tumors were analysed 14 days post-implantation of tumor cells and expression was compared to isotype control antibody (dashed lines). P-value represents an unpaired T-test result.

Article Snippet: Assays to test the affinity of IgGs for human CD36 were set up using OCTET anti-human IgG Fc capture (AHC) biosensors (18–5060; Sartorius) according to the manufacturer’s instructions.

Techniques: Sample Throughput, Binding Assay, Screening, High Content Screening, Functional Assay, Expressing, Transfection, Single Cell, RNA Sequencing, Analysis, Flow Cytometry, Control, Phage Display

Tool  anti-CD36   IgGs.

Journal: PLOS One

Article Title: Minimal functional activity and presence of an antigen sink limit CD36 blockade as a macrophage-targeted cancer immunotherapy

doi: 10.1371/journal.pone.0362100

Figure Lengend Snippet: Tool anti-CD36 IgGs.

Article Snippet: Assays to test the affinity of IgGs for human CD36 were set up using OCTET anti-human IgG Fc capture (AHC) biosensors (18–5060; Sartorius) according to the manufacturer’s instructions.

Techniques:

A. anti-CD36 mAbs from cell selection hits or commercial clones, or isotype controls were captured on anti-human Fc BLI sensors, then sequentially incubated with increasing concentrations of recombinant human or mouse CD36 extracellular domain with a C-terminal avi-tag. Mouse and human CD36 binding affinities and k on / k off rates are shown. In B, profiles are shown for antibodies and subsequently oxLDL binding to immobilized biotinylated human CD36 protein on streptavidin biosensors. BLI sensors loaded with hCD36 were incubated with anti-CD36 antibodies or matched isotype controls, followed by incubation in oxLDL, to test for antibody-mediated competition for the oxLDL binding site on CD36. C. Magnification of oxLDL association/dissociation steps, vertically aligned at the start of oxLDL binding. Immobilized CD36 pre-treated with non-binding mAbs showed binding of soluble oxLDL, whereas CD36 pre-coated with anti-CD36 mAbs blocked oxLDL binding. D. Infographic showing high-content imaging oxLDL cellular uptake assay. CHO-K1 parental cells and cells overexpressing full-length CD36 were incubated for 4 h with 50 μg/mL DiI-oxLDL in the presence of isotype and anti-CD36 IgGs. Representative overexposed 10X-magnified fluorescence images of DiI-oxLDL-incubated cells shows pre-treated or untreated with Macro0579 (50 nM). E-G. Total spot area of DiI-oxLDL in response to titrated IgG1 concentrations in parental CHO (E), mouse-CD36 (F) and (G) human-CD36 overexpressing CHO cells. Minimal uptake is observed in parental CHO cells whereas robust inhibition of uptake is seen in CD36-overexpressing cells blocked with increasing doses of anti-CD36 IgG1.

Journal: PLOS One

Article Title: Minimal functional activity and presence of an antigen sink limit CD36 blockade as a macrophage-targeted cancer immunotherapy

doi: 10.1371/journal.pone.0362100

Figure Lengend Snippet: A. anti-CD36 mAbs from cell selection hits or commercial clones, or isotype controls were captured on anti-human Fc BLI sensors, then sequentially incubated with increasing concentrations of recombinant human or mouse CD36 extracellular domain with a C-terminal avi-tag. Mouse and human CD36 binding affinities and k on / k off rates are shown. In B, profiles are shown for antibodies and subsequently oxLDL binding to immobilized biotinylated human CD36 protein on streptavidin biosensors. BLI sensors loaded with hCD36 were incubated with anti-CD36 antibodies or matched isotype controls, followed by incubation in oxLDL, to test for antibody-mediated competition for the oxLDL binding site on CD36. C. Magnification of oxLDL association/dissociation steps, vertically aligned at the start of oxLDL binding. Immobilized CD36 pre-treated with non-binding mAbs showed binding of soluble oxLDL, whereas CD36 pre-coated with anti-CD36 mAbs blocked oxLDL binding. D. Infographic showing high-content imaging oxLDL cellular uptake assay. CHO-K1 parental cells and cells overexpressing full-length CD36 were incubated for 4 h with 50 μg/mL DiI-oxLDL in the presence of isotype and anti-CD36 IgGs. Representative overexposed 10X-magnified fluorescence images of DiI-oxLDL-incubated cells shows pre-treated or untreated with Macro0579 (50 nM). E-G. Total spot area of DiI-oxLDL in response to titrated IgG1 concentrations in parental CHO (E), mouse-CD36 (F) and (G) human-CD36 overexpressing CHO cells. Minimal uptake is observed in parental CHO cells whereas robust inhibition of uptake is seen in CD36-overexpressing cells blocked with increasing doses of anti-CD36 IgG1.

Article Snippet: Assays to test the affinity of IgGs for human CD36 were set up using OCTET anti-human IgG Fc capture (AHC) biosensors (18–5060; Sartorius) according to the manufacturer’s instructions.

Techniques: Selection, Clone Assay, Incubation, Recombinant, Binding Assay, High Content Screening, Fluorescence, Inhibition, Binding Curves