|
CapitalBio Corporation
luxscan 10k-b microarray scanner Luxscan 10k B Microarray Scanner, supplied by CapitalBio Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/Microarrays/luxscan+10+k+microarray+scanner/nct06133946-1-30-34 Average 90 stars, based on 1 article reviews
luxscan 10k-b microarray scanner - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
Innopsys Inc
the innoscan 300 microarray scanner The Innoscan 300 Microarray Scanner, supplied by Innopsys Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/Microarrays/innoscan+300+microarray+scanner/nct06243497-6-1-6 Average 90 stars, based on 1 article reviews
the innoscan 300 microarray scanner - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
Olympus
issue microarray scanner Issue Microarray Scanner, supplied by Olympus, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/Microarrays/VS120+Virtual+Slide+Microscope+Virtual+Slide+Microscopy/pm42814517-283-18-22 Average 99 stars, based on 1 article reviews
issue microarray scanner - by Bioz Stars,
2026-10
99/100 stars
|
Buy from Supplier |
|
Danaher Inc
microarray scanner Microarray Scanner, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/Microarrays/GenePix+Microarray+Systems/pm42772593-192-17-19 Average 94 stars, based on 1 article reviews
microarray scanner - by Bioz Stars,
2026-10
94/100 stars
|
Buy from Supplier |
|
RayBiotech inc
cytokine protein microarray analysis cytokine protein levels Cytokine Protein Microarray Analysis Cytokine Protein Levels, supplied by RayBiotech inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/Microarrays/Mouse+Cytokine+Array+GS1000/pm42680000-156-0-11 Average 94 stars, based on 1 article reviews
cytokine protein microarray analysis cytokine protein levels - by Bioz Stars,
2026-10
94/100 stars
|
Buy from Supplier |
|
RayBiotech inc
jo urn al pr e p roo f 12 apoptosis protein microarray analysis apoptosis signaling Jo Urn Al Pr E P Roo F 12 Apoptosis Protein Microarray Analysis Apoptosis Signaling, supplied by RayBiotech inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/Microarrays/Mouse+Apoptosis+Signaling+Pathway+Array+C1/pm42680000-150-0-18 Average 94 stars, based on 1 article reviews
jo urn al pr e p roo f 12 apoptosis protein microarray analysis apoptosis signaling - by Bioz Stars,
2026-10
94/100 stars
|
Buy from Supplier |
|
SCIENION
non contact inkjet microarray printer ![]() Non Contact Inkjet Microarray Printer, supplied by SCIENION, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/Microarrays/sciFLEXARRAYER+S12/pmc13380757-243-19-23 Average 95 stars, based on 1 article reviews
non contact inkjet microarray printer - by Bioz Stars,
2026-10
95/100 stars
|
Buy from Supplier |
|
RayBiotech inc
antibody microarrays ![]() Antibody Microarrays, supplied by RayBiotech inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/Microarrays/Human+Immune+Response+Array+GS1/pm42565727-46-14-19 Average 94 stars, based on 1 article reviews
antibody microarrays - by Bioz Stars,
2026-10
94/100 stars
|
Buy from Supplier |
|
SCIENION
non contact microarray spotter ![]() Non Contact Microarray Spotter, supplied by SCIENION, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/Microarrays/sciFLEXARRAYER+S3/pmc13388467-92-19-24 Average 96 stars, based on 1 article reviews
non contact microarray spotter - by Bioz Stars,
2026-10
96/100 stars
|
Buy from Supplier |
Journal: iScience
Article Title: A rapid point-of-care test for vancomycin monitoring at the clinical bedside
doi: 10.1016/j.isci.2026.116064
Figure Lengend Snippet: The VANC-D4 assay (A) Fabrication of the VANC-D4 assay. SI-ATRP is used to grow POEGMA-co-GMA brushes on glass slides. Following SI-ATRP, VANC-BSA is inkjet printed into the polymer brush to create stable spots and fluorescently labeled anti-VANC antibodies (termed dAb) are printed on trehalose pads to create labile spots. (B) Sequential steps of the VANC-D4 assay. The steps of the VANC-D4 are (i) dispensing a blood sample on the surface, (ii) dissolution of the trehalose pads to release the fluorescently labeled dAb into solution, (iii) diffusion of the labeled dAb in the sample volume, (iv) detection of fluorescence signal from the antibody bound to immobilized VANC-BSA. (C) Representative VANC-D4 assay response in the presence of (i) no drug, (ii) low drug, and (iii) high drug concentration. (D) VANC monitoring across its clinical range using VANC-spiked whole blood diluted 100-fold in running buffer, analyzed in triplicate. The clinical range for the test is 1–45 μg/mL. Intensity values are shown, with error bars that represent the standard error of the means for n = 3 separate runs. The LOD for the presented dose-response curve was calculated to be 0.8 μg/mL.
Article Snippet: Following polymerization, D4 assays were fabricated using non-contact inkjet printing methods as described elsewhere., VANC-BSA was printed using a
Techniques: Polymer, Labeling, Dissolution, Diffusion-based Assay, Fluorescence, Concentration Assay
Journal: Frontiers in Immunology
Article Title: Stage-associated immunoproteomic profiling of serum autoantibody-captured retinal antigens in age-related macular degeneration
doi: 10.3389/fimmu.2026.1824524
Figure Lengend Snippet: Overview of the experimental workflow for analyzing retinal antigen profiles captured by serum autoantibodies from patients with different stages of AMD. Antibodies isolated from AMD patient serum were captured on Protein G magnetic beads and incubated overnight with porcine retinal lysates. Unbound retinal antigens were washed away, and antibody-bound antigens were subsequently subjected to MS analysis. Selected differentially expressed retinal antigen targets identified by MS were further evaluated and validated in serum and tear samples from AMD patients using antigen microarray technology. The image was created using BioRender.com ( https://biorender.com/ , accessed on 14. June 2026).
Article Snippet: Commercially obtained antigens ( ) were spotted in triplicates onto nitrocellulose-coated slides (Oncyte, Grace Bio Labs, USA) using a
Techniques: Isolation, Magnetic Beads, Incubation, Microarray
Journal: Frontiers in Immunology
Article Title: Stage-associated immunoproteomic profiling of serum autoantibody-captured retinal antigens in age-related macular degeneration
doi: 10.3389/fimmu.2026.1824524
Figure Lengend Snippet: Selection and validation of candidate retinal antigens recognized by serum and tear autoantibodies in patients with different stages of AMD. (A) Venn diagram showing shared and stage-specific differentially enriched retinal antigens captured by serum autoantibodies across AMD subgroups. (B) Heatmap showing the relative abundance of selected candidate retinal antigens across AMD stages. Red indicates increased abundance and blue indicates decreased abundance. Candidate antigens selected for further validation are highlighted with red boxes. (C–H) Antigen microarray validation of serum and tear autoantibody reactivity against selected retinal antigens, including PSMD6, HSPA12A, PTGES3, ATP5A1, PFKM, and SDHB, in CTRL and AMD subgroups. Data are presented as mean ± SE. *p < 0.05.
Article Snippet: Commercially obtained antigens ( ) were spotted in triplicates onto nitrocellulose-coated slides (Oncyte, Grace Bio Labs, USA) using a
Techniques: Selection, Biomarker Discovery, Microarray
Journal: Frontiers in Immunology
Article Title: Stage-associated immunoproteomic profiling of serum autoantibody-captured retinal antigens in age-related macular degeneration
doi: 10.3389/fimmu.2026.1824524
Figure Lengend Snippet: Validation and overlap analysis of selected candidate retinal antigens recognized by serum and tear autoantibodies in patients with different stages of AMD. (A) Venn diagram showing shared and stage-specific differentially enriched retinal antigens captured by serum autoantibodies across AMD subgroups. (B–G) A subset of candidate retinal antigen targets identified by serum autoantibody-based proteomic profiling, including FTH1, SAG, VIM, PRMT5, SEC22B, and HIST2H2AA3, was selected for further validation by antigen microarray analysis in serum and tear samples from CTRL and AMD subgroups. Data are presented as mean ± SE, with whiskers indicating 1.96 × SE.*p < 0.05. (H) Venn diagram showing the overlap among serum proteomics-positive results, serum autoantibody microarray-positive results, and tear autoantibody microarray-positive results. The antigen microarray analysis was performed as a targeted validation of selected MS-derived retinal antigen targets. Candidate antigens supported by multiple datasets are highlighted in red.
Article Snippet: Commercially obtained antigens ( ) were spotted in triplicates onto nitrocellulose-coated slides (Oncyte, Grace Bio Labs, USA) using a
Techniques: Biomarker Discovery, Microarray, Derivative Assay