Review



48.48 dynamic array tm ifcs  (fluidigm)


Bioz Verified Symbol fluidigm is a verified supplier
Bioz Manufacturer Symbol fluidigm manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    fluidigm 48.48 dynamic array tm ifcs
    48.48 Dynamic Array Tm Ifcs, supplied by fluidigm, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/Array+Tm+Ifc/48+48+access+array+ifc/pmc08602333-454-19-34
    Average 90 stars, based on 1 article reviews
    48.48 dynamic array tm ifcs - by Bioz Stars, 2026-11
    90/100 stars

    Images

    Related Articles

    other:

    Article Title: Gene Expression Profiling Reveals New Pathways and Genes Associated with Visna/Maedi Viral Disease
    Article Snippet: Five-fold dilutions of STA reactions were loaded onto 48.48 Dynamic Array IFC according to Fluidigm’s Fast Gene Expression Analysis using EvaGreen protocol.

    Article Title: Cystatin F acts as a mediator of immune suppression in glioblastoma.
    Article Snippet: Purpose Glioblastoma, the most aggressive type of brain cancer, is composed of heterogeneous populations of differentiated cells, cancer stem cells and immune cells.. Cystatin F, an endogenous inhibitor of lysosomal cysteine peptidases, regulates the function of cytotoxic immune cells.. The aim of this study was to determine which type of cells expresses cystatin F in glioblastoma and to determine the role of cystatin F during disease progression.

    Article Title: Upregulation of Cathepsin X in Glioblastoma: Interplay with γ-Enolase and the Effects of Selective Cathepsin X Inhibitors
    Article Snippet: Fluidigm BioMark HD System RT-PCR (Fluidigm Corporation, San Francisco, CA, USA) and 48.48 Dynamic Arrays IFC, where cDNA of 42 samples and 24 TaqMan Gene Expression assays (ThermoFisher Scientific, see ), were mixed pairwise in nanoliter chambers to enable parallel analysis of 2304 reactions.

    Article Title: Role of genetics in the development of cardiac allograft vasculopathy
    Article Snippet: Genetic testing Single nucleotide polymorphism (SNP) genotyping was performed using Fluidigm SNP Type assays and Fluidigm 48.48 Dynamic Array IFC (integrated fluidic circuit) for Genotyping on the Fluidigm BioMark platform.

    Article Title: Patient-derived tumor organoids mimic treatment-induced DNA damage response in glioblastoma
    Article Snippet: 48.48 Dynamic Arrays IFC , Fluidigm , Cat#BMK- M -48.48.

    Gene Expression:

    Article Title: DNA methylation and gene expression changes in mouse mammary tissue during successive lactations: part II - the impact of lactation rank.
    Article Snippet: .. Gene expression levels were measured on 48 × 48 GE Dynamic Array IFC using the Fluidigm BioMarkTM HD System. .. Fold changes were calculated by the ∆∆Ct method using ‘Fluidigm Real-Time PCR Analysis’ software.

    Article Title: A standardized gnotobiotic mouse model harboring a minimal 15-member mouse gut microbiota recapitulates SOPF/SPF phenotypes
    Article Snippet: .. Amplicons generated using these primers range between 60 and 99 bp. qPCR microfluidic assays were conducted in 48.48 Dynamic Array TM IFCs (integrated fluidic circuits) for EvaGreen Fast Gene Expression on a Biomark HD (Fluidigm) according to the manufacturer’s instructions, with complementary DNA diluted 100-fold, preamplified with pooled primers, and diluted again 100-fold. ..

    Generated:

    Article Title: A standardized gnotobiotic mouse model harboring a minimal 15-member mouse gut microbiota recapitulates SOPF/SPF phenotypes
    Article Snippet: .. Amplicons generated using these primers range between 60 and 99 bp. qPCR microfluidic assays were conducted in 48.48 Dynamic Array TM IFCs (integrated fluidic circuits) for EvaGreen Fast Gene Expression on a Biomark HD (Fluidigm) according to the manufacturer’s instructions, with complementary DNA diluted 100-fold, preamplified with pooled primers, and diluted again 100-fold. ..

    Real-time Polymerase Chain Reaction:

    Article Title: A standardized gnotobiotic mouse model harboring a minimal 15-member mouse gut microbiota recapitulates SOPF/SPF phenotypes
    Article Snippet: .. Amplicons generated using these primers range between 60 and 99 bp. qPCR microfluidic assays were conducted in 48.48 Dynamic Array TM IFCs (integrated fluidic circuits) for EvaGreen Fast Gene Expression on a Biomark HD (Fluidigm) according to the manufacturer’s instructions, with complementary DNA diluted 100-fold, preamplified with pooled primers, and diluted again 100-fold. ..



    Similar Products

    86
    Biomark Inc real time pcr dynamic array tm ifc platform
    Real Time Pcr Dynamic Array Tm Ifc Platform, supplied by Biomark Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/Array+Tm+Ifc/48+48+array+biomark+dynamic/pmc12559939-3-8-7
    Average 86 stars, based on 1 article reviews
    real time pcr dynamic array tm ifc platform - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    93
    fluidigm array tm ifc
    Array Tm Ifc, supplied by fluidigm, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/Array+Tm+Ifc/Assay+Loading+Reagent/pm39855563-97-8-14
    Average 93 stars, based on 1 article reviews
    array tm ifc - by Bioz Stars, 2026-11
    93/100 stars
      Buy from Supplier

    95
    fluidigm array tm integrated fluidic circuits
    Array Tm Integrated Fluidic Circuits, supplied by fluidigm, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/Array+Tm+Ifc/96%2E96+Dynamic+Array+IFC+for+Genotyping/pmc11507445-179-3-8
    Average 95 stars, based on 1 article reviews
    array tm integrated fluidic circuits - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    95
    fluidigm tm instrument
    Tm Instrument, supplied by fluidigm, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/Array+Tm+Ifc/96%2E96+Dynamic+Array+IFC+for+Gene+Expression/pmc09861536-125-38-40
    Average 95 stars, based on 1 article reviews
    tm instrument - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    96
    fluidigm biomark tm ifc dynamic array tm genotyping
    Estimations of duck genome retention in the RH clones. A: retention frequencies of thirty-one microsatellite markers and four scaffold markers before (white) and after (grey) whole genome amplification. The test was done on the 90 selected hybrids by conventional Agarose <t>genotyping.</t> The expected chromosome locations of the markers (given in brackets) are derived from the chicken/duck comparative FISH mapping and a duck genetic map (Marie-Etancelin et al., in prep) for the microsatellite markers and according to comparative genomic data given by the Narcisse software for the scaffold markers. B : Retention frequencies of thirty-nine scaffolds markers obtained using three different genotyping strategies. The thirty-nine scaffold markers were genotyped using either (i) the amplified panel with conventional agarose genotyping (blue: WGA-PCR), (ii) the non amplified panel and genotyping with the Fluidigm BioMark gene expression dynamic array (green: Pre-ampFLDMqPCR) or (iii) the amplified panel and genotyping with the Fluidigm BioMark TM <t>IFC</t> Dynamic Array TM genotyping by quantitative PCR without any pre-amplification step (purple: WGA-FLDMqPCR). The markers are distributed along the X axis from the lowest to the highest retention frequencies obtained by the first method (the amplified panel with conventional agarose genotyping WGA-PCR in blue).
    Biomark Tm Ifc Dynamic Array Tm Genotyping, supplied by fluidigm, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/Array+Tm+Ifc/Biomark/pmc03496577-172-9-8
    Average 96 stars, based on 1 article reviews
    biomark tm ifc dynamic array tm genotyping - by Bioz Stars, 2026-11
    96/100 stars
      Buy from Supplier

    90
    fluidigm 96.96 dynamic array tm integrated fluidic circuit (ifc)
    Estimations of duck genome retention in the RH clones. A: retention frequencies of thirty-one microsatellite markers and four scaffold markers before (white) and after (grey) whole genome amplification. The test was done on the 90 selected hybrids by conventional Agarose <t>genotyping.</t> The expected chromosome locations of the markers (given in brackets) are derived from the chicken/duck comparative FISH mapping and a duck genetic map (Marie-Etancelin et al., in prep) for the microsatellite markers and according to comparative genomic data given by the Narcisse software for the scaffold markers. B : Retention frequencies of thirty-nine scaffolds markers obtained using three different genotyping strategies. The thirty-nine scaffold markers were genotyped using either (i) the amplified panel with conventional agarose genotyping (blue: WGA-PCR), (ii) the non amplified panel and genotyping with the Fluidigm BioMark gene expression dynamic array (green: Pre-ampFLDMqPCR) or (iii) the amplified panel and genotyping with the Fluidigm BioMark TM <t>IFC</t> Dynamic Array TM genotyping by quantitative PCR without any pre-amplification step (purple: WGA-FLDMqPCR). The markers are distributed along the X axis from the lowest to the highest retention frequencies obtained by the first method (the amplified panel with conventional agarose genotyping WGA-PCR in blue).
    96.96 Dynamic Array Tm Integrated Fluidic Circuit (Ifc), supplied by fluidigm, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/Array+Tm+Ifc/48+48+dynamic+array+integrated+fluidic+circuits/pmc09604607-93-31-47
    Average 90 stars, based on 1 article reviews
    96.96 dynamic array tm integrated fluidic circuit (ifc) - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    95
    fluidigm 48 48 dynamic array tm integrated fluid circuit
    Estimations of duck genome retention in the RH clones. A: retention frequencies of thirty-one microsatellite markers and four scaffold markers before (white) and after (grey) whole genome amplification. The test was done on the 90 selected hybrids by conventional Agarose <t>genotyping.</t> The expected chromosome locations of the markers (given in brackets) are derived from the chicken/duck comparative FISH mapping and a duck genetic map (Marie-Etancelin et al., in prep) for the microsatellite markers and according to comparative genomic data given by the Narcisse software for the scaffold markers. B : Retention frequencies of thirty-nine scaffolds markers obtained using three different genotyping strategies. The thirty-nine scaffold markers were genotyped using either (i) the amplified panel with conventional agarose genotyping (blue: WGA-PCR), (ii) the non amplified panel and genotyping with the Fluidigm BioMark gene expression dynamic array (green: Pre-ampFLDMqPCR) or (iii) the amplified panel and genotyping with the Fluidigm BioMark TM <t>IFC</t> Dynamic Array TM genotyping by quantitative PCR without any pre-amplification step (purple: WGA-FLDMqPCR). The markers are distributed along the X axis from the lowest to the highest retention frequencies obtained by the first method (the amplified panel with conventional agarose genotyping WGA-PCR in blue).
    48 48 Dynamic Array Tm Integrated Fluid Circuit, supplied by fluidigm, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/Array+Tm+Ifc/48%2E48+Dynamic+Array+IFC+for+Genotyping/pmc08773042-78-11-19
    Average 95 stars, based on 1 article reviews
    48 48 dynamic array tm integrated fluid circuit - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    95
    fluidigm array tm ifcs
    Estimations of duck genome retention in the RH clones. A: retention frequencies of thirty-one microsatellite markers and four scaffold markers before (white) and after (grey) whole genome amplification. The test was done on the 90 selected hybrids by conventional Agarose <t>genotyping.</t> The expected chromosome locations of the markers (given in brackets) are derived from the chicken/duck comparative FISH mapping and a duck genetic map (Marie-Etancelin et al., in prep) for the microsatellite markers and according to comparative genomic data given by the Narcisse software for the scaffold markers. B : Retention frequencies of thirty-nine scaffolds markers obtained using three different genotyping strategies. The thirty-nine scaffold markers were genotyped using either (i) the amplified panel with conventional agarose genotyping (blue: WGA-PCR), (ii) the non amplified panel and genotyping with the Fluidigm BioMark gene expression dynamic array (green: Pre-ampFLDMqPCR) or (iii) the amplified panel and genotyping with the Fluidigm BioMark TM <t>IFC</t> Dynamic Array TM genotyping by quantitative PCR without any pre-amplification step (purple: WGA-FLDMqPCR). The markers are distributed along the X axis from the lowest to the highest retention frequencies obtained by the first method (the amplified panel with conventional agarose genotyping WGA-PCR in blue).
    Array Tm Ifcs, supplied by fluidigm, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/Array+Tm+Ifc/96%2E96+Dynamic+Array+IFC+for+Gene+Expression/bio_rxiv__2021__12__13__472353-116-24-27
    Average 95 stars, based on 1 article reviews
    array tm ifcs - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    90
    fluidigm 48.48 dynamic array tm ifcs
    Estimations of duck genome retention in the RH clones. A: retention frequencies of thirty-one microsatellite markers and four scaffold markers before (white) and after (grey) whole genome amplification. The test was done on the 90 selected hybrids by conventional Agarose <t>genotyping.</t> The expected chromosome locations of the markers (given in brackets) are derived from the chicken/duck comparative FISH mapping and a duck genetic map (Marie-Etancelin et al., in prep) for the microsatellite markers and according to comparative genomic data given by the Narcisse software for the scaffold markers. B : Retention frequencies of thirty-nine scaffolds markers obtained using three different genotyping strategies. The thirty-nine scaffold markers were genotyped using either (i) the amplified panel with conventional agarose genotyping (blue: WGA-PCR), (ii) the non amplified panel and genotyping with the Fluidigm BioMark gene expression dynamic array (green: Pre-ampFLDMqPCR) or (iii) the amplified panel and genotyping with the Fluidigm BioMark TM <t>IFC</t> Dynamic Array TM genotyping by quantitative PCR without any pre-amplification step (purple: WGA-FLDMqPCR). The markers are distributed along the X axis from the lowest to the highest retention frequencies obtained by the first method (the amplified panel with conventional agarose genotyping WGA-PCR in blue).
    48.48 Dynamic Array Tm Ifcs, supplied by fluidigm, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/Array+Tm+Ifc/48+48+access+array+ifc/pmc08602333-454-19-34
    Average 90 stars, based on 1 article reviews
    48.48 dynamic array tm ifcs - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    Estimations of duck genome retention in the RH clones. A: retention frequencies of thirty-one microsatellite markers and four scaffold markers before (white) and after (grey) whole genome amplification. The test was done on the 90 selected hybrids by conventional Agarose genotyping. The expected chromosome locations of the markers (given in brackets) are derived from the chicken/duck comparative FISH mapping and a duck genetic map (Marie-Etancelin et al., in prep) for the microsatellite markers and according to comparative genomic data given by the Narcisse software for the scaffold markers. B : Retention frequencies of thirty-nine scaffolds markers obtained using three different genotyping strategies. The thirty-nine scaffold markers were genotyped using either (i) the amplified panel with conventional agarose genotyping (blue: WGA-PCR), (ii) the non amplified panel and genotyping with the Fluidigm BioMark gene expression dynamic array (green: Pre-ampFLDMqPCR) or (iii) the amplified panel and genotyping with the Fluidigm BioMark TM IFC Dynamic Array TM genotyping by quantitative PCR without any pre-amplification step (purple: WGA-FLDMqPCR). The markers are distributed along the X axis from the lowest to the highest retention frequencies obtained by the first method (the amplified panel with conventional agarose genotyping WGA-PCR in blue).

    Journal: BMC Genomics

    Article Title: A duck RH panel and its potential for assisting NGS genome assembly

    doi: 10.1186/1471-2164-13-513

    Figure Lengend Snippet: Estimations of duck genome retention in the RH clones. A: retention frequencies of thirty-one microsatellite markers and four scaffold markers before (white) and after (grey) whole genome amplification. The test was done on the 90 selected hybrids by conventional Agarose genotyping. The expected chromosome locations of the markers (given in brackets) are derived from the chicken/duck comparative FISH mapping and a duck genetic map (Marie-Etancelin et al., in prep) for the microsatellite markers and according to comparative genomic data given by the Narcisse software for the scaffold markers. B : Retention frequencies of thirty-nine scaffolds markers obtained using three different genotyping strategies. The thirty-nine scaffold markers were genotyped using either (i) the amplified panel with conventional agarose genotyping (blue: WGA-PCR), (ii) the non amplified panel and genotyping with the Fluidigm BioMark gene expression dynamic array (green: Pre-ampFLDMqPCR) or (iii) the amplified panel and genotyping with the Fluidigm BioMark TM IFC Dynamic Array TM genotyping by quantitative PCR without any pre-amplification step (purple: WGA-FLDMqPCR). The markers are distributed along the X axis from the lowest to the highest retention frequencies obtained by the first method (the amplified panel with conventional agarose genotyping WGA-PCR in blue).

    Article Snippet: In our case, by performing qPCR with the Fluidigm BioMark TM IFC Dynamic Array TM genotyping, the additional benefit is high throughput, as the identification of bands on gel electrophoresis is replaced by monitoring the PCR with Ct (Cycle threshold) and end point Tm (melting temperature) values, allowing the distinction between specific and non-specific amplification profiles.

    Techniques: Clone Assay, Whole Genome Amplification, Derivative Assay, Software, Amplification, Expressing, Real-time Polymerase Chain Reaction

    Genotyping by Fluidigm BioMarkTM IFC Dynamic ArrayTM quantitative PCR. (A) WGA-FLDMqPCR: WGA-amplified DNA and qPCR. Left: double-strand DNA (dsDNA) accumulation curve as a function of the number of cycles. Right: melting curve of the final product. Green: positive control (duck DNA). Red: a hybrid which was positive (containing duck DNA corresponding to the marker tested). Blue: a negative hybrid. Yellow: negative control (hamster DNA). (B) Pre-ampFLDMqPCR: non-amplified DNA, a pre-amplification step with a mix of the 96 primer pairs for the 96 markers tested in the Fluidigm BioMarkTM assay and qPCR. The same markers and controls are used as in (A) . The sensitivity is higher in (B) , with a lower number of cycles necessary for detection of duck DNA. The negative control and the hybrid not containing duck DNA amplify at a much higher number of cycles and the non-specific products amplified can easily be distinguished by their different melting temperature values (right). In both experiments, no amplification was obtained from water (data not shown).

    Journal: BMC Genomics

    Article Title: A duck RH panel and its potential for assisting NGS genome assembly

    doi: 10.1186/1471-2164-13-513

    Figure Lengend Snippet: Genotyping by Fluidigm BioMarkTM IFC Dynamic ArrayTM quantitative PCR. (A) WGA-FLDMqPCR: WGA-amplified DNA and qPCR. Left: double-strand DNA (dsDNA) accumulation curve as a function of the number of cycles. Right: melting curve of the final product. Green: positive control (duck DNA). Red: a hybrid which was positive (containing duck DNA corresponding to the marker tested). Blue: a negative hybrid. Yellow: negative control (hamster DNA). (B) Pre-ampFLDMqPCR: non-amplified DNA, a pre-amplification step with a mix of the 96 primer pairs for the 96 markers tested in the Fluidigm BioMarkTM assay and qPCR. The same markers and controls are used as in (A) . The sensitivity is higher in (B) , with a lower number of cycles necessary for detection of duck DNA. The negative control and the hybrid not containing duck DNA amplify at a much higher number of cycles and the non-specific products amplified can easily be distinguished by their different melting temperature values (right). In both experiments, no amplification was obtained from water (data not shown).

    Article Snippet: In our case, by performing qPCR with the Fluidigm BioMark TM IFC Dynamic Array TM genotyping, the additional benefit is high throughput, as the identification of bands on gel electrophoresis is replaced by monitoring the PCR with Ct (Cycle threshold) and end point Tm (melting temperature) values, allowing the distinction between specific and non-specific amplification profiles.

    Techniques: Real-time Polymerase Chain Reaction, Amplification, Positive Control, Marker, Negative Control

     Genotyping  8 no hit markers using three different genotyping strategies

    Journal: BMC Genomics

    Article Title: A duck RH panel and its potential for assisting NGS genome assembly

    doi: 10.1186/1471-2164-13-513

    Figure Lengend Snippet: Genotyping 8 no hit markers using three different genotyping strategies

    Article Snippet: In our case, by performing qPCR with the Fluidigm BioMark TM IFC Dynamic Array TM genotyping, the additional benefit is high throughput, as the identification of bands on gel electrophoresis is replaced by monitoring the PCR with Ct (Cycle threshold) and end point Tm (melting temperature) values, allowing the distinction between specific and non-specific amplification profiles.

    Techniques:

    Comparison of marker retention with the three  genotyping  techniques

    Journal: BMC Genomics

    Article Title: A duck RH panel and its potential for assisting NGS genome assembly

    doi: 10.1186/1471-2164-13-513

    Figure Lengend Snippet: Comparison of marker retention with the three genotyping techniques

    Article Snippet: In our case, by performing qPCR with the Fluidigm BioMark TM IFC Dynamic Array TM genotyping, the additional benefit is high throughput, as the identification of bands on gel electrophoresis is replaced by monitoring the PCR with Ct (Cycle threshold) and end point Tm (melting temperature) values, allowing the distinction between specific and non-specific amplification profiles.

    Techniques: Marker