Review




Structured Review

Honigmann GmbH 3d printed scaphoid prosthesis
3d Printed Scaphoid Prosthesis, supplied by Honigmann GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+printed+prosthesis/scaphoid+prosthesis/pm39085142-252-11-1
Average 90 stars, based on 1 article reviews
3d printed scaphoid prosthesis - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

other:

Article Title: Customized 3D-printed Poly ether ether ketone cranial implant for cranioplasty of skull defects.
Article Snippet: or infections.. Cranioplasty is essential not only for protecting the brain but also for cosmetic reasons [1].. Due to its immunological and structural compatibility and low cost, the patient’s own autologous bone flap is often the first choice for reconstructing cranial defects [1–3].

Article Title: A comprehensive review of the educational, clinical and rehabilitative applications of 3D printing technology in hand surgery
Article Snippet: Honigmann et al. used alumina ceramic 3DP scaphoid replacements in a cadaveric study and reported physiological behavior under motion analysis compared to native scaphoids[29].

Article Title: Economic evaluation of the manufacturing of 3D-printed wrist orthoses vs low temperature thermoplastic wrist orthoses.
Article Snippet: Guebeli A, Thieringer F, Honigmann P, Keller M. In-house 3D-printed custom splints for non-operative treatment of distal radial fractures: a randomized controlled trial.

Article Title: Comparative CT-Based Assessment of Segmentation Accuracy and Volumetric Variability in Scaphoids from Frozen and Thawed Cadaver Arms for Scaphoid Prosthesis Modeling
Article Snippet: Honigmann P, Schumacher R, Marek R, Büttner F, Thieringer F, Haefeli M. A three-dimensional printed patient-speci c scaphoid replacement: a cadaveric study.

Article Title: Feasibility of 3D-Printed Locking Compression Plates with Polyether Ether Ketone (PEEK) in Tibial Comminuted Diaphyseal Fractures
Article Snippet: Honigmann et al. [ ] verified the possibility of manufacturing various forms of patient-specific surgical implants, such as osteosynthesis plates and fragment osteosynthesis plates, through the FDM method and using PEEK materials.

Article Title: Finite Element Analysis of Patient-Specific 3D-Printed Cranial Implant Manufactured with PMMA and PEEK: A Mechanical Comparative Study.
Article Snippet: Honigmann, P.; Sharma, N.; Schumacher, R.; Rueegg, J.; Haefeli, M.; Thieringer, F. In-hospital 3D printed scaphoid prosthesis using medical-grade polyetheretherketone (PEEK) biomaterial.

Article Title: The research status and future direction of polyetheretherketone in dental implant -A comprehensive review.
Article Snippet: 29) Honigmann P, Sharma N, Schumacher R, Rueegg J, Haefeli M, Thieringer F. In-hospital 3D printed scaphoid prosthesis using medical-grade polyetheretherketone (PEEK) biomaterial.

Suspension:

Article Title: Titanium patient-specific scaphoid replacement for unreconstructable nonunions: a case series study.
Article Snippet: Although reconstruction is the preferred treatment option for symptomatic scaphoid nonunions, this may not be an option due to inadequate bone quality or degenerative changes.. Existing salvage procedures tend to compromise function.. This study introduces an alternative approach through the utilisation of a 3-D-printed titanium patient-specific scaphoid implant.



Similar Products

86
Geomagic Inc 3d printed prosthesis
3d Printed Prosthesis, supplied by Geomagic Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+printed+prosthesis/3d+printed+prosthesis/pm42165180-43-1-7
Average 86 stars, based on 1 article reviews
3d printed prosthesis - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

90
BioMimetic Therapeutics 3d-printed custom-made prosthesis
3d Printed Custom Made Prosthesis, supplied by BioMimetic Therapeutics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+printed+prosthesis/3d+printed+custom+made+prosthesis/pm39774918-374-12-9
Average 90 stars, based on 1 article reviews
3d-printed custom-made prosthesis - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Waldemar Link GmbH Co KG 3d-printed custom-made distal tibia prosthesis trabeculink
Intraoperative images showing (A) the distal tibia surgical specimen after resection and (B) the resulting bone gap, which was later fulfilled with (C) our custom made <t>prosthetic</t> <t>implant.</t>
3d Printed Custom Made Distal Tibia Prosthesis Trabeculink, supplied by Waldemar Link GmbH Co KG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+printed+prosthesis/3d+printed+custom+made+distal+tibia+prosthesis+trabeculink/pmc11887833-87-10-26
Average 90 stars, based on 1 article reviews
3d-printed custom-made distal tibia prosthesis trabeculink - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Waldemar Link GmbH Co KG 3d-printed custom-made distal tibia prosthesis
Intraoperative images showing (A) the distal tibia surgical specimen after resection and (B) the resulting bone gap, which was later fulfilled with (C) our custom made <t>prosthetic</t> <t>implant.</t>
3d Printed Custom Made Distal Tibia Prosthesis, supplied by Waldemar Link GmbH Co KG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+printed+prosthesis/3d+printed+custom+made+distal+tibia+prosthesis/pmc11887833-67-10-26
Average 90 stars, based on 1 article reviews
3d-printed custom-made distal tibia prosthesis - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Honigmann GmbH 3d printed scaphoid prosthesis
Intraoperative images showing (A) the distal tibia surgical specimen after resection and (B) the resulting bone gap, which was later fulfilled with (C) our custom made <t>prosthetic</t> <t>implant.</t>
3d Printed Scaphoid Prosthesis, supplied by Honigmann GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+printed+prosthesis/scaphoid+prosthesis/pm39085142-252-11-1
Average 90 stars, based on 1 article reviews
3d printed scaphoid prosthesis - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Arcam Corporation 3d-printed glenohumeral fusion prosthesis
Design of the 3D-printed <t>glenohumeral</t> fusion <t>prosthesis</t> and model construction, and element division method and loading modes in the finite element analysis. (A,B) Design details of the 3D-printed glenohumeral fusion prosthesis. (C) Biomimetic bones (sawbones) of the shoulder joint were used to construct biomechanical experimental models for simulating proximal humerus bone defect reconstruction after proximal humerus tumor resection with the 3D-printed glenohumeral fusion prosthesis. (D–F) Three reconstruction models were created, all of which simulated the reconstruction of the bone defect after a 15-cm osteotomy in the proximal humerus. (D) Model 1 represented traditional glenohumeral arthrodesis with an intercalary allograft and a vascularized fibular graft. (E) Model 2 represented the 3D-printed glenohumeral fusion prosthesis. (F) Model 3 represented the 3D-printed glenohumeral fusion prosthesis with a metal plate fixed on the spine of the scapula. (G) The contact was set, and the grid was divided freely with solid 187 as the solid unit and 3 mm as the unit size. (H,I) The scapula was bound and fixed, and two loading modes were applied to the distal end of the humerus. (H) The first loading mode consisted of an axial load of 700 N along the humeral axis, which was equivalent to the pressure on the glenohumeral joint during arm elevation (Model 1 is taken as an example to illustrate two loading modes). (I) The loading mode consisted of a vertical downward load of 42.532 N, which was equivalent to the weight of the upper limb.
3d Printed Glenohumeral Fusion Prosthesis, supplied by Arcam Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+printed+prosthesis/3d+printed+glenohumeral+fusion+prosthesis/pmc11260710-48-2-8
Average 90 stars, based on 1 article reviews
3d-printed glenohumeral fusion prosthesis - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
BioMimetic Therapeutics 3d-printed glenohumeral fusion prosthesis
Design of the 3D-printed <t>glenohumeral</t> fusion <t>prosthesis</t> and model construction, and element division method and loading modes in the finite element analysis. (A,B) Design details of the 3D-printed glenohumeral fusion prosthesis. (C) Biomimetic bones (sawbones) of the shoulder joint were used to construct biomechanical experimental models for simulating proximal humerus bone defect reconstruction after proximal humerus tumor resection with the 3D-printed glenohumeral fusion prosthesis. (D–F) Three reconstruction models were created, all of which simulated the reconstruction of the bone defect after a 15-cm osteotomy in the proximal humerus. (D) Model 1 represented traditional glenohumeral arthrodesis with an intercalary allograft and a vascularized fibular graft. (E) Model 2 represented the 3D-printed glenohumeral fusion prosthesis. (F) Model 3 represented the 3D-printed glenohumeral fusion prosthesis with a metal plate fixed on the spine of the scapula. (G) The contact was set, and the grid was divided freely with solid 187 as the solid unit and 3 mm as the unit size. (H,I) The scapula was bound and fixed, and two loading modes were applied to the distal end of the humerus. (H) The first loading mode consisted of an axial load of 700 N along the humeral axis, which was equivalent to the pressure on the glenohumeral joint during arm elevation (Model 1 is taken as an example to illustrate two loading modes). (I) The loading mode consisted of a vertical downward load of 42.532 N, which was equivalent to the weight of the upper limb.
3d Printed Glenohumeral Fusion Prosthesis, supplied by BioMimetic Therapeutics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+printed+prosthesis/3d+printed+glenohumeral+fusion+prosthesis/pm39040498-65-124-39
Average 90 stars, based on 1 article reviews
3d-printed glenohumeral fusion prosthesis - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Arcam Corporation 3d-printed pti prosthesis
Ionic liquid-coated 3D-printed <t>prosthesis</t> prevents periprosthetic infection and promotes osseointegration simultaneously.
3d Printed Pti Prosthesis, supplied by Arcam Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+printed+prosthesis/3d+printed+glenohumeral+fusion+prosthesis/pmc11070339-34-2-8
Average 90 stars, based on 1 article reviews
3d-printed pti prosthesis - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Intraoperative images showing (A) the distal tibia surgical specimen after resection and (B) the resulting bone gap, which was later fulfilled with (C) our custom made prosthetic implant.

Journal: Acta Medica Lituanica

Article Title: Ankle and Distal Tibia Megaprostheses in Orthopedic Oncology: A Report of Two Cases and Review of the Literature

doi: 10.15388/Amed.2024.31.2.13

Figure Lengend Snippet: Intraoperative images showing (A) the distal tibia surgical specimen after resection and (B) the resulting bone gap, which was later fulfilled with (C) our custom made prosthetic implant.

Article Snippet: The bone defect was fulfilled with a 3D-printed custom-made distal tibia prosthesis consisting of a Ti6AL4V alloy with a TrabecuLink structure on its bone contact surfaces (Waldemar Link GmbH & Co., Hamburg, Germany), which was fixed to the remaining autograft and native tibia using custom made medial and anterior plates designed to avoid screw colliding in the tibial shaft.

Techniques:

Intraoperative images showing (A) the distal tibia surgical specimen after resection and (B) the resulting bone gap, which was later fulfilled with (C) our custom made prosthetic implant.

Journal: Acta Medica Lituanica

Article Title: Ankle and Distal Tibia Megaprostheses in Orthopedic Oncology: A Report of Two Cases and Review of the Literature

doi: 10.15388/Amed.2024.31.2.13

Figure Lengend Snippet: Intraoperative images showing (A) the distal tibia surgical specimen after resection and (B) the resulting bone gap, which was later fulfilled with (C) our custom made prosthetic implant.

Article Snippet: The bone defect was fulfilled with a 3D-printed custom-made distal tibia prosthesis consisting of a Ti6AL4V alloy with a TrabecuLink structure on its bone contact surfaces (Waldemar Link GmbH & Co., Hamburg, Germany), which was fixed to the native tibia with an uncemented stem ( ).

Techniques:

Design of the 3D-printed glenohumeral fusion prosthesis and model construction, and element division method and loading modes in the finite element analysis. (A,B) Design details of the 3D-printed glenohumeral fusion prosthesis. (C) Biomimetic bones (sawbones) of the shoulder joint were used to construct biomechanical experimental models for simulating proximal humerus bone defect reconstruction after proximal humerus tumor resection with the 3D-printed glenohumeral fusion prosthesis. (D–F) Three reconstruction models were created, all of which simulated the reconstruction of the bone defect after a 15-cm osteotomy in the proximal humerus. (D) Model 1 represented traditional glenohumeral arthrodesis with an intercalary allograft and a vascularized fibular graft. (E) Model 2 represented the 3D-printed glenohumeral fusion prosthesis. (F) Model 3 represented the 3D-printed glenohumeral fusion prosthesis with a metal plate fixed on the spine of the scapula. (G) The contact was set, and the grid was divided freely with solid 187 as the solid unit and 3 mm as the unit size. (H,I) The scapula was bound and fixed, and two loading modes were applied to the distal end of the humerus. (H) The first loading mode consisted of an axial load of 700 N along the humeral axis, which was equivalent to the pressure on the glenohumeral joint during arm elevation (Model 1 is taken as an example to illustrate two loading modes). (I) The loading mode consisted of a vertical downward load of 42.532 N, which was equivalent to the weight of the upper limb.

Journal: Frontiers in Bioengineering and Biotechnology

Article Title: Design and validation of a novel 3D-printed glenohumeral fusion prosthesis for the reconstruction of proximal humerus bone defects: a biomechanical study

doi: 10.3389/fbioe.2024.1428446

Figure Lengend Snippet: Design of the 3D-printed glenohumeral fusion prosthesis and model construction, and element division method and loading modes in the finite element analysis. (A,B) Design details of the 3D-printed glenohumeral fusion prosthesis. (C) Biomimetic bones (sawbones) of the shoulder joint were used to construct biomechanical experimental models for simulating proximal humerus bone defect reconstruction after proximal humerus tumor resection with the 3D-printed glenohumeral fusion prosthesis. (D–F) Three reconstruction models were created, all of which simulated the reconstruction of the bone defect after a 15-cm osteotomy in the proximal humerus. (D) Model 1 represented traditional glenohumeral arthrodesis with an intercalary allograft and a vascularized fibular graft. (E) Model 2 represented the 3D-printed glenohumeral fusion prosthesis. (F) Model 3 represented the 3D-printed glenohumeral fusion prosthesis with a metal plate fixed on the spine of the scapula. (G) The contact was set, and the grid was divided freely with solid 187 as the solid unit and 3 mm as the unit size. (H,I) The scapula was bound and fixed, and two loading modes were applied to the distal end of the humerus. (H) The first loading mode consisted of an axial load of 700 N along the humeral axis, which was equivalent to the pressure on the glenohumeral joint during arm elevation (Model 1 is taken as an example to illustrate two loading modes). (I) The loading mode consisted of a vertical downward load of 42.532 N, which was equivalent to the weight of the upper limb.

Article Snippet: The 3D-printed glenohumeral fusion prosthesis was fabricated by Arcam Q10 PLUS (Arcam Inc., Germany) using high-energy electron beam melting (EBM) technology.

Techniques: Construct

Two reconstruction models in the biomechanical experiment verification, and the total displacement of the prosthesis and the maximum principal strain of the glenoid cavity at an axial downward pressure of 700 N in the biomechanical experiment. (A,C) The reconstruction model using the 3D-printed glenohumeral fusion prosthesis with a lateral metal plate fixed on the spine of the scapula (with-plate group); (B,D) The reconstruction model using the 3D-printed glenohumeral fusion prosthesis only (without-plate group). (E) The total displacement of the prosthesis in the with-plate group. (F) The total displacement of the prosthesis in the without-plate group. (G) The maximum principal strain of the glenoid cavity in the with-plate group. (H) The maximum principal strain of the glenoid cavity in the without-plate group.

Journal: Frontiers in Bioengineering and Biotechnology

Article Title: Design and validation of a novel 3D-printed glenohumeral fusion prosthesis for the reconstruction of proximal humerus bone defects: a biomechanical study

doi: 10.3389/fbioe.2024.1428446

Figure Lengend Snippet: Two reconstruction models in the biomechanical experiment verification, and the total displacement of the prosthesis and the maximum principal strain of the glenoid cavity at an axial downward pressure of 700 N in the biomechanical experiment. (A,C) The reconstruction model using the 3D-printed glenohumeral fusion prosthesis with a lateral metal plate fixed on the spine of the scapula (with-plate group); (B,D) The reconstruction model using the 3D-printed glenohumeral fusion prosthesis only (without-plate group). (E) The total displacement of the prosthesis in the with-plate group. (F) The total displacement of the prosthesis in the without-plate group. (G) The maximum principal strain of the glenoid cavity in the with-plate group. (H) The maximum principal strain of the glenoid cavity in the without-plate group.

Article Snippet: The 3D-printed glenohumeral fusion prosthesis was fabricated by Arcam Q10 PLUS (Arcam Inc., Germany) using high-energy electron beam melting (EBM) technology.

Techniques:

Ionic liquid-coated 3D-printed prosthesis prevents periprosthetic infection and promotes osseointegration simultaneously.

Journal: Materials Today Bio

Article Title: A multifunctional ionic liquid coating on 3D-Printed prostheses: Combating infection, promoting osseointegration

doi: 10.1016/j.mtbio.2024.101076

Figure Lengend Snippet: Ionic liquid-coated 3D-printed prosthesis prevents periprosthetic infection and promotes osseointegration simultaneously.

Article Snippet: The 3D-printed pTi prosthesis was manufactured by the Arcam Electron Beam Melting (EBM) system (Q10, Sweden), following the method described in our previous studies [ , , ].

Techniques: Infection

Elemental compositions on the  prosthesis  surfaces determined by EDS.

Journal: Materials Today Bio

Article Title: A multifunctional ionic liquid coating on 3D-Printed prostheses: Combating infection, promoting osseointegration

doi: 10.1016/j.mtbio.2024.101076

Figure Lengend Snippet: Elemental compositions on the prosthesis surfaces determined by EDS.

Article Snippet: The 3D-printed pTi prosthesis was manufactured by the Arcam Electron Beam Melting (EBM) system (Q10, Sweden), following the method described in our previous studies [ , , ].

Techniques:

In vitro NIR photothermal bactericidal activity of the pTi@MMIB. (a, b) Infrared thermographic images (a) and temperature change curves (b) of the pTi and pTi@MMIB under NIR irradiation (808 nm, 2 W cm −2 ). (c) On–off temperature curves for pTi@MMIB under NIR irradiation (808 nm, 2 W cm −2 ). (d, g) Photographs of the bacterial colonies after the standard plate count assay and SEM images of the adhered bacteria on the prosthesis surfaces. (e, h) Number of adhered bacteria on the prosthesis surfaces. (f, i) NIR photothermal bactericidal activity of pTi and pTi@MMIB. (d–f) for E. coli , (g–i) for S. aureus . n = 3, **p < 0.01, ***p < 0.001.

Journal: Materials Today Bio

Article Title: A multifunctional ionic liquid coating on 3D-Printed prostheses: Combating infection, promoting osseointegration

doi: 10.1016/j.mtbio.2024.101076

Figure Lengend Snippet: In vitro NIR photothermal bactericidal activity of the pTi@MMIB. (a, b) Infrared thermographic images (a) and temperature change curves (b) of the pTi and pTi@MMIB under NIR irradiation (808 nm, 2 W cm −2 ). (c) On–off temperature curves for pTi@MMIB under NIR irradiation (808 nm, 2 W cm −2 ). (d, g) Photographs of the bacterial colonies after the standard plate count assay and SEM images of the adhered bacteria on the prosthesis surfaces. (e, h) Number of adhered bacteria on the prosthesis surfaces. (f, i) NIR photothermal bactericidal activity of pTi and pTi@MMIB. (d–f) for E. coli , (g–i) for S. aureus . n = 3, **p < 0.01, ***p < 0.001.

Article Snippet: The 3D-printed pTi prosthesis was manufactured by the Arcam Electron Beam Melting (EBM) system (Q10, Sweden), following the method described in our previous studies [ , , ].

Techniques: In Vitro, Activity Assay, Irradiation, Bacteria

In vivo anti-infection performance of the pTi@MMIB. (a) Temperature change of the implanting pTi and pTi@MMIB under NIR irradiation (808 nm, 2 W cm −2 ). (b) The survival of the animals during the entire experiment. (c) WBC count in the peripheral blood evaluates the severity of systemic infection (n = 5). (d) Neutrophils count in the peripheral blood after different time of treatment (n = 5). (e) IL-6 content after different time of treatment (n = 5). (f) Giemsa staining shows bacterial contamination in the tissue around the prosthesis interfaces (red arrows indicate bacteria). (For interpretation of the references to color in this figure legend, the reader is referred to the Web version of this article.)

Journal: Materials Today Bio

Article Title: A multifunctional ionic liquid coating on 3D-Printed prostheses: Combating infection, promoting osseointegration

doi: 10.1016/j.mtbio.2024.101076

Figure Lengend Snippet: In vivo anti-infection performance of the pTi@MMIB. (a) Temperature change of the implanting pTi and pTi@MMIB under NIR irradiation (808 nm, 2 W cm −2 ). (b) The survival of the animals during the entire experiment. (c) WBC count in the peripheral blood evaluates the severity of systemic infection (n = 5). (d) Neutrophils count in the peripheral blood after different time of treatment (n = 5). (e) IL-6 content after different time of treatment (n = 5). (f) Giemsa staining shows bacterial contamination in the tissue around the prosthesis interfaces (red arrows indicate bacteria). (For interpretation of the references to color in this figure legend, the reader is referred to the Web version of this article.)

Article Snippet: The 3D-printed pTi prosthesis was manufactured by the Arcam Electron Beam Melting (EBM) system (Q10, Sweden), following the method described in our previous studies [ , , ].

Techniques: In Vivo, Infection, Irradiation, Staining, Bacteria

In vivo bone regeneration and osseointegration assessment around the prosthesis interfaces. (a) Gross view of the lateral condyle of distal femurs. (b) 3D reconstruction images of the prosthesis (white) and regenerated bone tissue (yellow). (c–f) Bone morphometric analysis of bone volume/tissue volume (BV/TV) (c), trabecular number (Tb·N) (d), trabecular bone thickness (Tb·Th) (e), trabecular separation (Tb.Sp) (f) according to Micro-CT at 12 weeks post-implantation. (g) Representative histological images of Masson staining (the black areas indicate the pTi prosthesis, the blue areas indicate the bone, and the yellow areas indicate pus). (h) Biomechanical evaluation by pull-out testing to study the osseointegration between the prosthesis interfaces. (i) Representative images of calcein fluorescence double-labelling of bone regeneration around the prosthesis interfaces. (j) Mineral apposition rate (MAR) by calcein fluorescence double labelling (n = 5, *p < 0.05, **p < 0.01, ***p < 0.001). (For interpretation of the references to color in this figure legend, the reader is referred to the Web version of this article.)

Journal: Materials Today Bio

Article Title: A multifunctional ionic liquid coating on 3D-Printed prostheses: Combating infection, promoting osseointegration

doi: 10.1016/j.mtbio.2024.101076

Figure Lengend Snippet: In vivo bone regeneration and osseointegration assessment around the prosthesis interfaces. (a) Gross view of the lateral condyle of distal femurs. (b) 3D reconstruction images of the prosthesis (white) and regenerated bone tissue (yellow). (c–f) Bone morphometric analysis of bone volume/tissue volume (BV/TV) (c), trabecular number (Tb·N) (d), trabecular bone thickness (Tb·Th) (e), trabecular separation (Tb.Sp) (f) according to Micro-CT at 12 weeks post-implantation. (g) Representative histological images of Masson staining (the black areas indicate the pTi prosthesis, the blue areas indicate the bone, and the yellow areas indicate pus). (h) Biomechanical evaluation by pull-out testing to study the osseointegration between the prosthesis interfaces. (i) Representative images of calcein fluorescence double-labelling of bone regeneration around the prosthesis interfaces. (j) Mineral apposition rate (MAR) by calcein fluorescence double labelling (n = 5, *p < 0.05, **p < 0.01, ***p < 0.001). (For interpretation of the references to color in this figure legend, the reader is referred to the Web version of this article.)

Article Snippet: The 3D-printed pTi prosthesis was manufactured by the Arcam Electron Beam Melting (EBM) system (Q10, Sweden), following the method described in our previous studies [ , , ].

Techniques: In Vivo, Micro-CT, Staining, Fluorescence

Representative histological H&E staining images of the main organs taken from the different groups three months after prosthesis implantation.

Journal: Materials Today Bio

Article Title: A multifunctional ionic liquid coating on 3D-Printed prostheses: Combating infection, promoting osseointegration

doi: 10.1016/j.mtbio.2024.101076

Figure Lengend Snippet: Representative histological H&E staining images of the main organs taken from the different groups three months after prosthesis implantation.

Article Snippet: The 3D-printed pTi prosthesis was manufactured by the Arcam Electron Beam Melting (EBM) system (Q10, Sweden), following the method described in our previous studies [ , , ].

Techniques: Staining