Review




Structured Review

Matrixx Initiatives 2d ionization chamber array i’mrt
2d Ionization Chamber Array I’mrt, supplied by Matrixx Initiatives, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2d+ionization+chamber+array/2d+ionization+chamber+array+i%E2%80%99mrt/pm38071091-176-15-16
Average 90 stars, based on 1 article reviews
2d ionization chamber array i’mrt - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

other:

Article Title: A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy.
Article Snippet: Purpose: The objective of this work is to present a new 2D plastic scintillation detectors array (2D-PSDA) designed for the dosimetry of megavoltage (MV) energy photon beams in radiation therapy and to characterize its basic performance.. Methods: We developed a 2D detector array consisting of 781 plastic scintillation detectors (PSDs) inserted into a plane of a water-equivalent phantom.. The PSDs were distributed on a 26 26 cm grid, with an interdetector spacing of 10 mm, except for two perpendicular lines centered on the detection plane, where the spacing was 5 mm.

Article Title: Dosimetric characterization of the iBEAM evo carbon fiber couch for radiotherapy.
Article Snippet: Dosimetric characterization of the iBEAM evo carbon fiber couch for radiotherapy David W. Smith, Damianos Christophides, Christopher Dean, Mitchell Naisbit, Joshua Mason, and Andrew Morgan Citation: Medical Physics 37, 3595 (2010); doi: 10.1118/1.3451114 View online: http://dx.doi.org/10.1118/1.3451114 View Table of Contents: http://scitation.aip.org/content/aapm/journal/medphys/37/7?ver=pdfcov Published by the American Association of Physicists in Medicine Articles you may be interested in Carbon fiber couch effects on skin dose for volumetric modulated arcs Med.. Phys.. 38, 2419 (2011); 10.1118/1.3576106 Evaluation of two-dimensional bolus effect of immobilization/support devices on skin doses: A radiochromic EBT film dosimetry study in phantom Med.

Article Title: Study of Stability and Sensitivity of Three-dimensional Diode Array Detector
Article Snippet: Hybrid plan verification for intensity-modulated radiation therapy (IMRT) using the 2D ionization chamber array I’mRT MatriXX–a feasibility study.

Article Title: Patient-specific 3D pretreatment and potential 3D online dose verification of Monte Carlo-calculated IMRT prostate treatment plans.
Article Snippet: Reprint Radiation Theodor-K 621-383-3 umm.de Purpose: Fast and reliable comprehensive quality assurance tools are required to validate the safety and accuracy of complex intensity-modulated radiotherapy (IMRT) plans for prostate treatment.. In this study, we evaluated the performance of the COMPASS system for both off-line and potential online procedures for the verification of IMRT treatment plans.. Methods and Materials: COMPASS has a dedicated beam model and dose engine, it can reconstruct threedimensional dose distributions on the patient anatomy based on measured fluences using either the MatriXX two-dimensional (2D) array (offline) or a 2D transmission detector (T2D) (online).

Article Title: Evaluation of volumetric modulated arc therapy (VMAT) with Oncentra MasterPlan® for the treatment of head and neck cancer
Article Snippet: Dobler B, Streck N, Klein E, Loeschel R, Haertl P, Koelbl O: Hybrid plan verification for intensity-modulated radiation therapy (IMRT) using the 2 D ionization chamber array I’mRT MatriXX–a feasibility study.

Article Title: Patient specific quality assurance of volumetric modulated arc therapy of synchronous bilateral breast cancer.
Article Snippet: Synchronous bilateral breast cancers (SBBC) present a considerable issue in external beam radiotherapy because of large fields size and large target volumes.. Mono-isocentric volumetric modulated arc therapy (VMAT) appears as an appropriate irradiation technique for these types of tumors.. The aim of this study was to demonstrate the utility of a 3D DVH pretreatment quality assurance program in VMAT of SBBC cases.

Article Title: Searching standard parameters for volumetric modulated arc therapy (VMAT) of prostate cancer
Article Snippet: Dobler B, Streck N, Klein E, Loeschel R, Haertl P, Koelbl O: Hybrid plan verification for intensity-modulated radiation therapy (IMRT) using the 2D ionization chamber array I’mRT MatriXX—a feasability study.



Similar Products

86
Liverage Biomedical Inc crossmini 2d strip ionization chamber detector array
Signal amplitude from the <t>CROSSmini</t> detector with signal fitting and zoomed in views. Figures A, B and C, on the left, shows the signal amplitude from the CROSSmini detector of a spill duration for energy level 70.2, 150.2, and 228.7 MeV, respectively, with nominal beam current 8 MU/s. The red line represents the original signal from CROSSmini and the black line represents the piecewise fitting for the edges. On the right is the zoomed in view of the fitting. The piecewise fitting quantifies the risetime ( t rise ) and measured nominal beam current ( I 0 , measured ).
Crossmini 2d Strip Ionization Chamber Detector Array, supplied by Liverage Biomedical Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2d+ionization+chamber+array/pmc13138202-56-7-14
Average 86 stars, based on 1 article reviews
crossmini 2d strip ionization chamber detector array - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

90
IBA Dosimetry 2d ionization chamber array matrixxone
Signal amplitude from the <t>CROSSmini</t> detector with signal fitting and zoomed in views. Figures A, B and C, on the left, shows the signal amplitude from the CROSSmini detector of a spill duration for energy level 70.2, 150.2, and 228.7 MeV, respectively, with nominal beam current 8 MU/s. The red line represents the original signal from CROSSmini and the black line represents the piecewise fitting for the edges. On the right is the zoomed in view of the fitting. The piecewise fitting quantifies the risetime ( t rise ) and measured nominal beam current ( I 0 , measured ).
2d Ionization Chamber Array Matrixxone, supplied by IBA Dosimetry, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2d+ionization+chamber+array/the+matrixx+evolution+2d+ionization+chamber+array/pmc12138570-65-15-20
Average 90 stars, based on 1 article reviews
2d ionization chamber array matrixxone - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
IBA Dosimetry 2d ionization chambers array matrixxpt
Signal amplitude from the <t>CROSSmini</t> detector with signal fitting and zoomed in views. Figures A, B and C, on the left, shows the signal amplitude from the CROSSmini detector of a spill duration for energy level 70.2, 150.2, and 228.7 MeV, respectively, with nominal beam current 8 MU/s. The red line represents the original signal from CROSSmini and the black line represents the piecewise fitting for the edges. On the right is the zoomed in view of the fitting. The piecewise fitting quantifies the risetime ( t rise ) and measured nominal beam current ( I 0 , measured ).
2d Ionization Chambers Array Matrixxpt, supplied by IBA Dosimetry, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2d+ionization+chamber+array/the+matrixx+evolution+2d+ionization+chamber+array/pm39939287-194-25-30
Average 90 stars, based on 1 article reviews
2d ionization chambers array matrixxpt - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
IBA Dosimetry matrixx one is a 2d ionization chamber array
Signal amplitude from the <t>CROSSmini</t> detector with signal fitting and zoomed in views. Figures A, B and C, on the left, shows the signal amplitude from the CROSSmini detector of a spill duration for energy level 70.2, 150.2, and 228.7 MeV, respectively, with nominal beam current 8 MU/s. The red line represents the original signal from CROSSmini and the black line represents the piecewise fitting for the edges. On the right is the zoomed in view of the fitting. The piecewise fitting quantifies the risetime ( t rise ) and measured nominal beam current ( I 0 , measured ).
Matrixx One Is A 2d Ionization Chamber Array, supplied by IBA Dosimetry, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2d+ionization+chamber+array/the+matrixx+evolution+2d+ionization+chamber+array/pm39854837-200-4-8
Average 90 stars, based on 1 article reviews
matrixx one is a 2d ionization chamber array - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Matrixx Initiatives 2d ionization chamber array detector
Signal amplitude from the <t>CROSSmini</t> detector with signal fitting and zoomed in views. Figures A, B and C, on the left, shows the signal amplitude from the CROSSmini detector of a spill duration for energy level 70.2, 150.2, and 228.7 MeV, respectively, with nominal beam current 8 MU/s. The red line represents the original signal from CROSSmini and the black line represents the piecewise fitting for the edges. On the right is the zoomed in view of the fitting. The piecewise fitting quantifies the risetime ( t rise ) and measured nominal beam current ( I 0 , measured ).
2d Ionization Chamber Array Detector, supplied by Matrixx Initiatives, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2d+ionization+chamber+array/2d+ion+chamber+array/pm39854837-171-17-16
Average 90 stars, based on 1 article reviews
2d ionization chamber array detector - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Matrixx Initiatives pt 2d ionization chamber array detector
Signal amplitude from the <t>CROSSmini</t> detector with signal fitting and zoomed in views. Figures A, B and C, on the left, shows the signal amplitude from the CROSSmini detector of a spill duration for energy level 70.2, 150.2, and 228.7 MeV, respectively, with nominal beam current 8 MU/s. The red line represents the original signal from CROSSmini and the black line represents the piecewise fitting for the edges. On the right is the zoomed in view of the fitting. The piecewise fitting quantifies the risetime ( t rise ) and measured nominal beam current ( I 0 , measured ).
Pt 2d Ionization Chamber Array Detector, supplied by Matrixx Initiatives, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2d+ionization+chamber+array/2d+ion+chamber+array/10__1016_slash_j__radphyschem__2024__111953-79-24-23
Average 90 stars, based on 1 article reviews
pt 2d ionization chamber array detector - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Matrixx Initiatives 2d ionization chamber array i’mrt
Signal amplitude from the <t>CROSSmini</t> detector with signal fitting and zoomed in views. Figures A, B and C, on the left, shows the signal amplitude from the CROSSmini detector of a spill duration for energy level 70.2, 150.2, and 228.7 MeV, respectively, with nominal beam current 8 MU/s. The red line represents the original signal from CROSSmini and the black line represents the piecewise fitting for the edges. On the right is the zoomed in view of the fitting. The piecewise fitting quantifies the risetime ( t rise ) and measured nominal beam current ( I 0 , measured ).
2d Ionization Chamber Array I’mrt, supplied by Matrixx Initiatives, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2d+ionization+chamber+array/2d+ionization+chamber+array+i%E2%80%99mrt/pm38071091-176-15-16
Average 90 stars, based on 1 article reviews
2d ionization chamber array i’mrt - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
IBA Dosimetry 2d arrays with ionization chambers
Signal amplitude from the <t>CROSSmini</t> detector with signal fitting and zoomed in views. Figures A, B and C, on the left, shows the signal amplitude from the CROSSmini detector of a spill duration for energy level 70.2, 150.2, and 228.7 MeV, respectively, with nominal beam current 8 MU/s. The red line represents the original signal from CROSSmini and the black line represents the piecewise fitting for the edges. On the right is the zoomed in view of the fitting. The piecewise fitting quantifies the risetime ( t rise ) and measured nominal beam current ( I 0 , measured ).
2d Arrays With Ionization Chambers, supplied by IBA Dosimetry, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2d+ionization+chamber+array/the+matrixx+evolution+2d+ionization+chamber+array/pmc10476988-46-27-41
Average 90 stars, based on 1 article reviews
2d arrays with ionization chambers - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
PTW Freiburg GmbH 2d ionization chamber array octavius detector 1500 xdr
(a) Measurement device combined with a <t>2D</t> <t>ionization</t> chamber array and an accordion-type water phantom. (b) Typical results for PSQA. The upper and lower panels show the PC and HNC cases, respectively. The arrows on the dose distribution indicate the dose profile’s direction. (c) The gamma passing rate in the clinical cases.
2d Ionization Chamber Array Octavius Detector 1500 Xdr, supplied by PTW Freiburg GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2d+ionization+chamber+array/2d+ionization+chamber+array+octavius+detector+1500+xdr/pmc09089877-183-11-19
Average 90 stars, based on 1 article reviews
2d ionization chamber array octavius detector 1500 xdr - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Matrixx Initiatives ionization chamber 2d array
(a) Measurement device combined with a <t>2D</t> <t>ionization</t> chamber array and an accordion-type water phantom. (b) Typical results for PSQA. The upper and lower panels show the PC and HNC cases, respectively. The arrows on the dose distribution indicate the dose profile’s direction. (c) The gamma passing rate in the clinical cases.
Ionization Chamber 2d Array, supplied by Matrixx Initiatives, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2d+ionization+chamber+array/2d+ion+chamber+array/pm32634280-12687-11-17
Average 90 stars, based on 1 article reviews
ionization chamber 2d array - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Signal amplitude from the CROSSmini detector with signal fitting and zoomed in views. Figures A, B and C, on the left, shows the signal amplitude from the CROSSmini detector of a spill duration for energy level 70.2, 150.2, and 228.7 MeV, respectively, with nominal beam current 8 MU/s. The red line represents the original signal from CROSSmini and the black line represents the piecewise fitting for the edges. On the right is the zoomed in view of the fitting. The piecewise fitting quantifies the risetime ( t rise ) and measured nominal beam current ( I 0 , measured ).

Journal: International Journal of Particle Therapy

Article Title: Phenomenological Study of Intra-Spill Break Spots in Dose-Driven Continuous Scanning Proton Therapy

doi: 10.1016/j.ijpt.2026.101315

Figure Lengend Snippet: Signal amplitude from the CROSSmini detector with signal fitting and zoomed in views. Figures A, B and C, on the left, shows the signal amplitude from the CROSSmini detector of a spill duration for energy level 70.2, 150.2, and 228.7 MeV, respectively, with nominal beam current 8 MU/s. The red line represents the original signal from CROSSmini and the black line represents the piecewise fitting for the edges. On the right is the zoomed in view of the fitting. The piecewise fitting quantifies the risetime ( t rise ) and measured nominal beam current ( I 0 , measured ).

Article Snippet: The beam current was measured using a CROSSmini 2D strip ionization chamber detector array (Liverage Biomedical Inc, Taiwan) positioned at the isocenter plane.

Techniques:

Signal amplitude from the CROSSmini detector with signal fitting. shows the signal amplitude as a function of time measured by the CROSSmini detector and the piecewise fittings. Figures A, B, and C are measurements for energy level 70.2 MeV with nominal beam current 8, 14, and 20 MU/s, respectively. Figures D, E, and F are the measurements for energy level 228.7 MeV with nominal beam current 8, 14, and 20 MU/s, respectively.

Journal: International Journal of Particle Therapy

Article Title: Phenomenological Study of Intra-Spill Break Spots in Dose-Driven Continuous Scanning Proton Therapy

doi: 10.1016/j.ijpt.2026.101315

Figure Lengend Snippet: Signal amplitude from the CROSSmini detector with signal fitting. shows the signal amplitude as a function of time measured by the CROSSmini detector and the piecewise fittings. Figures A, B, and C are measurements for energy level 70.2 MeV with nominal beam current 8, 14, and 20 MU/s, respectively. Figures D, E, and F are the measurements for energy level 228.7 MeV with nominal beam current 8, 14, and 20 MU/s, respectively.

Article Snippet: The beam current was measured using a CROSSmini 2D strip ionization chamber detector array (Liverage Biomedical Inc, Taiwan) positioned at the isocenter plane.

Techniques:

t rise comparison between analytical and measured. The blue and red plots represent the analytically derived t rise and CROSSmini measured t rise , respectively, across the various nominal beam current settings.

Journal: International Journal of Particle Therapy

Article Title: Phenomenological Study of Intra-Spill Break Spots in Dose-Driven Continuous Scanning Proton Therapy

doi: 10.1016/j.ijpt.2026.101315

Figure Lengend Snippet: t rise comparison between analytical and measured. The blue and red plots represent the analytically derived t rise and CROSSmini measured t rise , respectively, across the various nominal beam current settings.

Article Snippet: The beam current was measured using a CROSSmini 2D strip ionization chamber detector array (Liverage Biomedical Inc, Taiwan) positioned at the isocenter plane.

Techniques: Comparison, Derivative Assay

(a) Measurement device combined with a 2D ionization chamber array and an accordion-type water phantom. (b) Typical results for PSQA. The upper and lower panels show the PC and HNC cases, respectively. The arrows on the dose distribution indicate the dose profile’s direction. (c) The gamma passing rate in the clinical cases.

Journal: PLoS ONE

Article Title: Commissioning a newly developed treatment planning system, VQA Plan, for fast-raster scanning of carbon-ion beams

doi: 10.1371/journal.pone.0268087

Figure Lengend Snippet: (a) Measurement device combined with a 2D ionization chamber array and an accordion-type water phantom. (b) Typical results for PSQA. The upper and lower panels show the PC and HNC cases, respectively. The arrows on the dose distribution indicate the dose profile’s direction. (c) The gamma passing rate in the clinical cases.

Article Snippet: We performed the measurements using the PinPoint chamber and a commercial 2D ionization chamber array (OCTAVIUS Detector 1500 XDR, PTW-Freiburg GmbH, Freiburg, Germany) mounted on an accordion-type water phantom that enables the water-equivalent thickness to be changed easily [ ].

Techniques: