ecis zθ and 16w array station with ecis software (Applied BioPhysics)
Structured Review

Ecis Zθ And 16w Array Station With Ecis Software, supplied by Applied BioPhysics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/16w+software/ecis+z%CE%B8+and+16w+array+station+with+ecis+software/pmc05644665-77-19-21
Average 90 stars, based on 1 article reviews
Images
1) Product Images from "Elucidating the molecular basis of PPCD: Effects of decreased ZEB1 expression on corneal endothelial cell function"
Article Title: Elucidating the molecular basis of PPCD: Effects of decreased ZEB1 expression on corneal endothelial cell function
Journal: Molecular Vision
doi:
Figure Legend Snippet: The impact of ZEB1 reduction on cell migration in HCEnC-21T cells. A : HCEnC-21T cells were transfected with either ZEB1 siRNA-C or scrambled siRNA (sc-siRNA), and knockdown of ZEB1 was validated with western blotting. B : Transfected HCEnC-21T cells were seeded to 100% confluence on an electric cell–substrate impedance sensing (ECIS) electrode array. A high current (arrow) was applied to the circular electrode underneath the central region of the cell monolayer, thus clearing the circular area. Migration of cells into the cleared area was monitored for 12 h after wounding by measuring impedance (ohms) across the electrode at 4,000 Hz. Three wells for each condition were measured; n = 3. Error bars = standard error of the mean (SEM).
Techniques Used: Migration, Transfection, Knockdown, Western Blot, Electric Cell-substrate Impedance Sensing
Figure Legend Snippet: The impact of ZEB1 reduction on cell barrier function in in HCEnC-21T cells. A : HCEnC-21T cells were transfected with ZEB1 siRNA-C or scrambled siRNA (sc-siRNA), and knockdown of ZEB1 was confirmed with western blotting. B : Impedance (ohm) at 4,000 Hz, interendothelial resistance (Rb), cell attachment resistance (alpha), and plasma membrane capacitance (Cm) were measured for 48 h after seeding on electric cell–substrate impedance sensing (ECIS) electrode arrays. Three wells for each condition were measured; n = 3. Error bars = standard error of the mean (SEM). Statistical significance (p<0.05) is noted for a range when two or more sequential time points demonstrated statistical significance.
Techniques Used: Transfection, Knockdown, Western Blot, Cell Attachment Assay, Clinical Proteomics, Membrane, Electric Cell-substrate Impedance Sensing
Related Articles
Generated:Article Title: Elucidating the molecular basis of PPCD: Effects of decreased ZEB1 expression on corneal endothelial cell function Article Snippet: 8W1E electric cell–substrate impedance sensing (ECIS) Cultureware disposable electrode arrays (Applied BioPhysics, Troy, NY) were stabilized with F99 medium according to the manufacturer’s protocol and then were coated with 40 μg/cm 2 chondroitin sulfate A (Sigma-Aldrich) and 400 ng/cm 2 laminin (Sigma-Aldrich) in PBS for 2 h. Twenty-four hours after transfection, the HCEnC-21T cells were reseeded at 100% confluency in the stabilized electrode arrays. .. At 24 h after reseeding, a circular gap in the cell layer above each electrode was generated by applying the cell wounding module to the electrode array at a current of 1400 μA, a frequency of 60,000 Hz, and a duration of 20 s. Cell migration across the gap was monitored by measuring the resistance (ohms) at the electrode using an ECIS Zθ and Migration:Article Title: Elucidating the molecular basis of PPCD: Effects of decreased ZEB1 expression on corneal endothelial cell function Article Snippet: 8W1E electric cell–substrate impedance sensing (ECIS) Cultureware disposable electrode arrays (Applied BioPhysics, Troy, NY) were stabilized with F99 medium according to the manufacturer’s protocol and then were coated with 40 μg/cm 2 chondroitin sulfate A (Sigma-Aldrich) and 400 ng/cm 2 laminin (Sigma-Aldrich) in PBS for 2 h. Twenty-four hours after transfection, the HCEnC-21T cells were reseeded at 100% confluency in the stabilized electrode arrays. .. At 24 h after reseeding, a circular gap in the cell layer above each electrode was generated by applying the cell wounding module to the electrode array at a current of 1400 μA, a frequency of 60,000 Hz, and a duration of 20 s. Cell migration across the gap was monitored by measuring the resistance (ohms) at the electrode using an ECIS Zθ and Electric Cell-substrate Impedance Sensing:Article Title: Elucidating the molecular basis of PPCD: Effects of decreased ZEB1 expression on corneal endothelial cell function Article Snippet: 8W1E electric cell–substrate impedance sensing (ECIS) Cultureware disposable electrode arrays (Applied BioPhysics, Troy, NY) were stabilized with F99 medium according to the manufacturer’s protocol and then were coated with 40 μg/cm 2 chondroitin sulfate A (Sigma-Aldrich) and 400 ng/cm 2 laminin (Sigma-Aldrich) in PBS for 2 h. Twenty-four hours after transfection, the HCEnC-21T cells were reseeded at 100% confluency in the stabilized electrode arrays. .. At 24 h after reseeding, a circular gap in the cell layer above each electrode was generated by applying the cell wounding module to the electrode array at a current of 1400 μA, a frequency of 60,000 Hz, and a duration of 20 s. Cell migration across the gap was monitored by measuring the resistance (ohms) at the electrode using an ECIS Zθ and Article Title: Elucidating the molecular basis of PPCD: Effects of decreased ZEB1 expression on corneal endothelial cell function Article Snippet: The arrays were subsequently coated with 40 μg/cm 2 chondroitin sulfate A (Sigma-Aldrich) and 400 ng/cm 2 laminin (Sigma-Aldrich) in PBS for 2 h. Forty-eight hours after transfection, HCEnC-21T cells were reseeded at 100% confluency in the coated and stabilized electrode arrays. .. Measured in ohms, cell resistances at multiple frequencies were monitored using an ECIS Zθ and Software:Article Title: Elucidating the molecular basis of PPCD: Effects of decreased ZEB1 expression on corneal endothelial cell function Article Snippet: 8W1E electric cell–substrate impedance sensing (ECIS) Cultureware disposable electrode arrays (Applied BioPhysics, Troy, NY) were stabilized with F99 medium according to the manufacturer’s protocol and then were coated with 40 μg/cm 2 chondroitin sulfate A (Sigma-Aldrich) and 400 ng/cm 2 laminin (Sigma-Aldrich) in PBS for 2 h. Twenty-four hours after transfection, the HCEnC-21T cells were reseeded at 100% confluency in the stabilized electrode arrays. .. At 24 h after reseeding, a circular gap in the cell layer above each electrode was generated by applying the cell wounding module to the electrode array at a current of 1400 μA, a frequency of 60,000 Hz, and a duration of 20 s. Cell migration across the gap was monitored by measuring the resistance (ohms) at the electrode using an ECIS Zθ and Article Title: Elucidating the molecular basis of PPCD: Effects of decreased ZEB1 expression on corneal endothelial cell function Article Snippet: The arrays were subsequently coated with 40 μg/cm 2 chondroitin sulfate A (Sigma-Aldrich) and 400 ng/cm 2 laminin (Sigma-Aldrich) in PBS for 2 h. Forty-eight hours after transfection, HCEnC-21T cells were reseeded at 100% confluency in the coated and stabilized electrode arrays. .. Measured in ohms, cell resistances at multiple frequencies were monitored using an ECIS Zθ and |