|
Greiner Bio
96 well microplate 96 Well Microplate, supplied by Greiner Bio, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/96 well microplate/product/Greiner Bio Average 96 stars, based on 1 article reviews
96 well microplate - by Bioz Stars,
2026-06
96/100 stars
|
Buy from Supplier |
|
Greiner Bio
ubottom 96 well microplates Ubottom 96 Well Microplates, supplied by Greiner Bio, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/ubottom 96 well microplates/product/Greiner Bio Average 93 stars, based on 1 article reviews
ubottom 96 well microplates - by Bioz Stars,
2026-06
93/100 stars
|
Buy from Supplier |
|
Greiner Bio
pbs 96 well round bottom polystyrene microtiter plate Pbs 96 Well Round Bottom Polystyrene Microtiter Plate, supplied by Greiner Bio, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/pbs 96 well round bottom polystyrene microtiter plate/product/Greiner Bio Average 96 stars, based on 1 article reviews
pbs 96 well round bottom polystyrene microtiter plate - by Bioz Stars,
2026-06
96/100 stars
|
Buy from Supplier |
|
Greiner Bio
black microplate Black Microplate, supplied by Greiner Bio, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/black microplate/product/Greiner Bio Average 94 stars, based on 1 article reviews
black microplate - by Bioz Stars,
2026-06
94/100 stars
|
Buy from Supplier |
|
Greiner Bio
round bottom microplates Round Bottom Microplates, supplied by Greiner Bio, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/round bottom microplates/product/Greiner Bio Average 95 stars, based on 1 article reviews
round bottom microplates - by Bioz Stars,
2026-06
95/100 stars
|
Buy from Supplier |
|
Revvity
384 well microplate 384 Well Microplate, supplied by Revvity, used in various techniques. Bioz Stars score: 91/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/384 well microplate/product/Revvity Average 91 stars, based on 1 article reviews
384 well microplate - by Bioz Stars,
2026-06
91/100 stars
|
Buy from Supplier |
|
Greiner Bio
u bottom microplates U Bottom Microplates, supplied by Greiner Bio, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/u bottom microplates/product/Greiner Bio Average 96 stars, based on 1 article reviews
u bottom microplates - by Bioz Stars,
2026-06
96/100 stars
|
Buy from Supplier |
|
Greiner Bio
well microplate Well Microplate, supplied by Greiner Bio, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/well microplate/product/Greiner Bio Average 95 stars, based on 1 article reviews
well microplate - by Bioz Stars,
2026-06
95/100 stars
|
Buy from Supplier |
|
Greiner Bio
white 96 well microplate White 96 Well Microplate, supplied by Greiner Bio, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/white 96 well microplate/product/Greiner Bio Average 94 stars, based on 1 article reviews
white 96 well microplate - by Bioz Stars,
2026-06
94/100 stars
|
Buy from Supplier |
|
Greiner Bio
well u bottom clear cell repellent surface microplates Well U Bottom Clear Cell Repellent Surface Microplates, supplied by Greiner Bio, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/well u bottom clear cell repellent surface microplates/product/Greiner Bio Average 94 stars, based on 1 article reviews
well u bottom clear cell repellent surface microplates - by Bioz Stars,
2026-06
94/100 stars
|
Buy from Supplier |
|
Greiner Bio
microplates ![]() Microplates, supplied by Greiner Bio, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/microplates/product/Greiner Bio Average 94 stars, based on 1 article reviews
microplates - by Bioz Stars,
2026-06
94/100 stars
|
Buy from Supplier |
|
Greiner Bio
96 well polypropylene microplates ![]() 96 Well Polypropylene Microplates, supplied by Greiner Bio, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/96 well polypropylene microplates/product/Greiner Bio Average 93 stars, based on 1 article reviews
96 well polypropylene microplates - by Bioz Stars,
2026-06
93/100 stars
|
Buy from Supplier |
Image Search Results
Journal: bioRxiv
Article Title: A CD25-CCR7 complex initiates non-canonical IL-2 signaling
doi: 10.1101/2025.02.03.636356
Figure Lengend Snippet: (A) 7G7B6 triggers IL-2 dependent hCD25-CCR7 complex . 5 ug/mL anti human CD25 antibodies 7G7B6 or BC96 were incubated with HA-hCD25 expressing HEK293T cells in the presence or absence of 1 ug/mL IL-2 and following lysis and immunoprecipitation with anti-HA were assayed for captured CCR7 or HA-hCD25 by immunoblotting. (B) IL-2(E52K) does not support 7G7B6-induced hCD25-CCR7 complex . IL-2(E52K) or wild type IL-2 were assayed for capacity to support 7G7B6-induced CD25-CCR7 complex as described in panel A. (C) IL2(E52K) mutation does not disrupt CD25-IL-2 interaction . Microplates coated with recombinant hCD25 extracellular domain were incubated with the indicated concentrations of IL-2 or IL-2(E52K) and bound IL-2 was quantified by ELISA. (D) IL-2(E52K) does not trigger MACS-dependent integrin activation . IL-2Rα YT-1 cells. were incubated with indicated reagents in the presence of 5 μg/mL hMAdCAM-1 Fc for 30 min at 37 o C, followed by APC-anti-human IgG Fc and FACS to assess MAdCAM-1 binding. (E) IL-2(E52K) does not trigger MACS-dependent integrin activation Freshly isolated human Tregs were incubated with 7G7B6 and 5 μg/ml VCAM-1 Fc (these cells express little α4β7) and 7G7B6 in the presence or absence of IL-2(WT) or IL-2(E52K) (E52K) for 30 min at 37 o C before measurement of bound VCAM-1 Fc by FACS. In some experiments 200 ng/ml Pertussis toxin was added (PTX) or an irrelevant antibody (iso) was added in place of 7G7B6. (F) IL-2(E52K) triggers canonical IL-2 signaling . IL2Rα YT-1 cells were stimulated with varying concentrations of IL-2 or IL-2(E52K) for 30 min at 37 o C, followed by staining with APC-anti phospho-STAT5 and analysis by FACS. *: p<0.05, **: p<0.01, NS: not significant by one-way ANOVA.
Article Snippet:
Techniques: Incubation, Expressing, Lysis, Immunoprecipitation, Western Blot, Mutagenesis, Recombinant, Enzyme-linked Immunosorbent Assay, Activation Assay, Binding Assay, Isolation, Staining