tmae fractogel Search Results


90
Merck KGaA tmae(m) column minichrom column fractogel® tmae (m)
Tmae(m) Column Minichrom Column Fractogel® Tmae (M), supplied by Merck KGaA, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tmae+fractogel/tmae+m++column+minichrom+column+fractogel++tmae++m+/pmc07212201-58-5-12
Average 90 stars, based on 1 article reviews
tmae(m) column minichrom column fractogel® tmae (m) - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Merck KGaA anion-exchange fractogel tmae (m) matrix
Anion Exchange Fractogel Tmae (M) Matrix, supplied by Merck KGaA, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tmae+fractogel/anion+exchange+fractogel+tmae++m++matrix/pmc07349063-67-6-11
Average 90 stars, based on 1 article reviews
anion-exchange fractogel tmae (m) matrix - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Merck & Co fractogel emd tmae hicap (m) column
Fractogel Emd Tmae Hicap (M) Column, supplied by Merck & Co, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tmae+fractogel/fractogel+emd+so3/pm36307781-85-25-31
Average 90 stars, based on 1 article reviews
fractogel emd tmae hicap (m) column - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Merck KGaA fractogel emd tmae hicap
Fractogel Emd Tmae Hicap, supplied by Merck KGaA, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tmae+fractogel/fractogel+emd+tmae+hicap/us08604175-134-4-10
Average 90 stars, based on 1 article reviews
fractogel emd tmae hicap - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Merck KGaA anion exchange resin fractogel emd tmae
Anion Exchange Resin Fractogel Emd Tmae, supplied by Merck KGaA, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tmae+fractogel/anion+exchange+resin+fractogel+emd+tmae/us10414816-188-1-7
Average 90 stars, based on 1 article reviews
anion exchange resin fractogel emd tmae - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Merck KGaA fractogel®-tmae prepacked minichrom column 8
Fractogel® Tmae Prepacked Minichrom Column 8, supplied by Merck KGaA, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tmae+fractogel/fractogel++tmae+prepacked+minichrom+column+8/10__1002_slash_jssc__201901215-150-10-18
Average 90 stars, based on 1 article reviews
fractogel®-tmae prepacked minichrom column 8 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
EM Science Inc fractogel emd tmae-650 (s)tm
Fractogel Emd Tmae 650 (S)tm, supplied by EM Science Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tmae+fractogel/fractogel+tmae+column/us09644195-317-30-34
Average 90 stars, based on 1 article reviews
fractogel emd tmae-650 (s)tm - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Merck KGaA ion exchange resin tmae-fractogel(s)
Ion Exchange Resin Tmae Fractogel(s), supplied by Merck KGaA, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tmae+fractogel/ion+exchange+resin+tmae+fractogel+s+/us09163228-11-8-12
Average 90 stars, based on 1 article reviews
ion exchange resin tmae-fractogel(s) - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Merck KGaA fractogel emd tmae tentacle gel
Fractogel Emd Tmae Tentacle Gel, supplied by Merck KGaA, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tmae+fractogel/fractogel+emd+tmae+tentacle+gel/us07166709-2-8-15
Average 90 stars, based on 1 article reviews
fractogel emd tmae tentacle gel - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Prosep Inc fractogel® tmae hicap resin
Fractogel® Tmae Hicap Resin, supplied by Prosep Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tmae+fractogel/fractogel++tmae+hicap+resin/us11590434-640-65-49
Average 90 stars, based on 1 article reviews
fractogel® tmae hicap resin - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

86
Merck & Co fractogel tmae m prepacked column
UV280 breakthrough chromatogram during anion-exchange chromatography on <t>Fractogel</t> <t>TMAE</t> (M) used to deplete IgA and IgM from the caprylic acid–purified EQ-IgG intermediate. The IgG-rich flow-through (breakthrough zone) was collected, whereas retained proteins (including IgA/IgM) were subsequently eluted during the regeneration step. The final peak corresponds to the column cleaning-in-place (CIP) step. UV absorbance is shown at 280 nm as a function of elution volume (mL).
Fractogel Tmae M Prepacked Column, supplied by Merck & Co, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tmae+fractogel/column+fractogel+m+prepacked+tmae/bio_rxiv__64898__2026__02__26__708374-45-3-10
Average 86 stars, based on 1 article reviews
fractogel tmae m prepacked column - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

90
Merck KGaA fractogel tmd tmae m
UV280 breakthrough chromatogram during anion-exchange chromatography on <t>Fractogel</t> <t>TMAE</t> (M) used to deplete IgA and IgM from the caprylic acid–purified EQ-IgG intermediate. The IgG-rich flow-through (breakthrough zone) was collected, whereas retained proteins (including IgA/IgM) were subsequently eluted during the regeneration step. The final peak corresponds to the column cleaning-in-place (CIP) step. UV absorbance is shown at 280 nm as a function of elution volume (mL).
Fractogel Tmd Tmae M, supplied by Merck KGaA, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tmae+fractogel/fractogel+tmd+tmae+m/pm15596359-67-12-16
Average 90 stars, based on 1 article reviews
fractogel tmd tmae m - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


UV280 breakthrough chromatogram during anion-exchange chromatography on Fractogel TMAE (M) used to deplete IgA and IgM from the caprylic acid–purified EQ-IgG intermediate. The IgG-rich flow-through (breakthrough zone) was collected, whereas retained proteins (including IgA/IgM) were subsequently eluted during the regeneration step. The final peak corresponds to the column cleaning-in-place (CIP) step. UV absorbance is shown at 280 nm as a function of elution volume (mL).

Journal: bioRxiv

Article Title: IgA/IgM chromatographic depletion enables efficient 20-nm virus nanofiltration of mini-pool caprylic-acid IgG

doi: 10.64898/2026.02.26.708374

Figure Lengend Snippet: UV280 breakthrough chromatogram during anion-exchange chromatography on Fractogel TMAE (M) used to deplete IgA and IgM from the caprylic acid–purified EQ-IgG intermediate. The IgG-rich flow-through (breakthrough zone) was collected, whereas retained proteins (including IgA/IgM) were subsequently eluted during the regeneration step. The final peak corresponds to the column cleaning-in-place (CIP) step. UV absorbance is shown at 280 nm as a function of elution volume (mL).

Article Snippet: A 5 mL Fractogel TMAE (M) prepacked column (MiniChrom format; Merck), was equilibrated with 25 mM sodium acetate buffer (pH 5.9).

Techniques: Chromatography, Purification

Effect of IgA/IgM depletion on Planova nanofiltration performance of caprylic acid–purified IgG (CA-IgG). (A) Direct nanofiltration of CA-IgG using Planova 20N (membrane area 0.001 m²) shows an early decline in permeate flux after ∼29 min, yielding only ∼16 mL of filtrate after 120 min (0.8 kgf/cm²). (B) Sequential filtration of CA-IgG using Planova 35N followed by 20N (0.001 m² each) under identical conditions does not prevent early flux decline (after ∼26–27 min) and results in a similar filtrate volume (∼15–16 mL after 120 min). (C) After Fractogel TMAE chromatography (IgA/IgM-depleted flow-through), sequential Planova 35N→20N filtration shows stable filtrate accumulation, indicating improved filterability after upstream removal of fouling components. (D,E) Volume–time plots used to derive permeate flow rates for the Fractogel TMAE flow-through during sequential filtration using Planova 35N→20N (D) and Planova 35N→S20N (E). Under the same feed conditions, the S20N run shows a higher steady permeate flow (∼1.5 mL/min) than the 20N run (∼0.5 mL/min). In panels A–C, cumulative filtrate mass (g) is plotted versus time; overlaid traces represent repeated runs.

Journal: bioRxiv

Article Title: IgA/IgM chromatographic depletion enables efficient 20-nm virus nanofiltration of mini-pool caprylic-acid IgG

doi: 10.64898/2026.02.26.708374

Figure Lengend Snippet: Effect of IgA/IgM depletion on Planova nanofiltration performance of caprylic acid–purified IgG (CA-IgG). (A) Direct nanofiltration of CA-IgG using Planova 20N (membrane area 0.001 m²) shows an early decline in permeate flux after ∼29 min, yielding only ∼16 mL of filtrate after 120 min (0.8 kgf/cm²). (B) Sequential filtration of CA-IgG using Planova 35N followed by 20N (0.001 m² each) under identical conditions does not prevent early flux decline (after ∼26–27 min) and results in a similar filtrate volume (∼15–16 mL after 120 min). (C) After Fractogel TMAE chromatography (IgA/IgM-depleted flow-through), sequential Planova 35N→20N filtration shows stable filtrate accumulation, indicating improved filterability after upstream removal of fouling components. (D,E) Volume–time plots used to derive permeate flow rates for the Fractogel TMAE flow-through during sequential filtration using Planova 35N→20N (D) and Planova 35N→S20N (E). Under the same feed conditions, the S20N run shows a higher steady permeate flow (∼1.5 mL/min) than the 20N run (∼0.5 mL/min). In panels A–C, cumulative filtrate mass (g) is plotted versus time; overlaid traces represent repeated runs.

Article Snippet: A 5 mL Fractogel TMAE (M) prepacked column (MiniChrom format; Merck), was equilibrated with 25 mM sodium acetate buffer (pH 5.9).

Techniques: Purification, Membrane, Filtration, Chromatography

DLS and NTA profiles of the apparent size distribution and subvisible particulate content of IgG intermediates after Fractogel TMAE chromatography and Planova nanofiltration. (A) Dynamic light scattering (DLS) intensity-weighted hydrodynamic size distributions of the Fractogel flow-through and of products after Planova 35N filtration and sequential Planova 35N→20N filtration. Z-average hydrodynamic diameter and polydispersity index (PDI) are shown below each plot. (B) Representative DLS intensity distributions for the corresponding products (Fractogel–35N, Fractogel–35N–20N, and Fractogel–35N–S20N). (C) Nanoparticle tracking analysis (NTA) of the same IgG solutions showing the concentration and apparent size distribution of subvisible, light-scattering particles (IgG aggregates/particulates); total particle concentration (particles/mL) and measurements at comparable tracking density or particles per frame (∼30–33) are indicated in each panel. The NTA data show a marked reduction in detectable subvisible particles after Planova 20N or S20N filtration.

Journal: bioRxiv

Article Title: IgA/IgM chromatographic depletion enables efficient 20-nm virus nanofiltration of mini-pool caprylic-acid IgG

doi: 10.64898/2026.02.26.708374

Figure Lengend Snippet: DLS and NTA profiles of the apparent size distribution and subvisible particulate content of IgG intermediates after Fractogel TMAE chromatography and Planova nanofiltration. (A) Dynamic light scattering (DLS) intensity-weighted hydrodynamic size distributions of the Fractogel flow-through and of products after Planova 35N filtration and sequential Planova 35N→20N filtration. Z-average hydrodynamic diameter and polydispersity index (PDI) are shown below each plot. (B) Representative DLS intensity distributions for the corresponding products (Fractogel–35N, Fractogel–35N–20N, and Fractogel–35N–S20N). (C) Nanoparticle tracking analysis (NTA) of the same IgG solutions showing the concentration and apparent size distribution of subvisible, light-scattering particles (IgG aggregates/particulates); total particle concentration (particles/mL) and measurements at comparable tracking density or particles per frame (∼30–33) are indicated in each panel. The NTA data show a marked reduction in detectable subvisible particles after Planova 20N or S20N filtration.

Article Snippet: A 5 mL Fractogel TMAE (M) prepacked column (MiniChrom format; Merck), was equilibrated with 25 mM sodium acetate buffer (pH 5.9).

Techniques: Chromatography, Filtration, Concentration Assay

SDS–PAGE profile of IgG intermediates under non-reducing (conditions before and after IgA/IgM depletion and Planova nanofiltration. All samples show a dominant band at ∼150 kDa consistent with intact IgG and depletion of higher-molecular-weight species after sequential Planova nanofiltration. Lane assignments: (1) caprylic acid–purified IgG (CA-IgG); (2) Fractogel TMAE (M) flow-through (EQ-IgG); (3) Planova 35N filtrate; (4) sequential Planova 35N→20N filtrate; (5) sequential Planova 35N→S20N filtrate. Molecular weight markers (kDa) are shown on the left.

Journal: bioRxiv

Article Title: IgA/IgM chromatographic depletion enables efficient 20-nm virus nanofiltration of mini-pool caprylic-acid IgG

doi: 10.64898/2026.02.26.708374

Figure Lengend Snippet: SDS–PAGE profile of IgG intermediates under non-reducing (conditions before and after IgA/IgM depletion and Planova nanofiltration. All samples show a dominant band at ∼150 kDa consistent with intact IgG and depletion of higher-molecular-weight species after sequential Planova nanofiltration. Lane assignments: (1) caprylic acid–purified IgG (CA-IgG); (2) Fractogel TMAE (M) flow-through (EQ-IgG); (3) Planova 35N filtrate; (4) sequential Planova 35N→20N filtrate; (5) sequential Planova 35N→S20N filtrate. Molecular weight markers (kDa) are shown on the left.

Article Snippet: A 5 mL Fractogel TMAE (M) prepacked column (MiniChrom format; Merck), was equilibrated with 25 mM sodium acetate buffer (pH 5.9).

Techniques: SDS Page, Molecular Weight, Purification