|
Larodan
sulfatide Sulfatide, supplied by Larodan, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sulfatide/lyso-Sulfatide+(bovine)+NH4%2B+salt/pm16086686-41-55-61 Average 90 stars, based on 1 article reviews
sulfatide - by Bioz Stars,
2026-09
90/100 stars
|
Buy from Supplier |
|
Croda International Plc
bovine brain sulfatides Bovine Brain Sulfatides, supplied by Croda International Plc, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sulfatide/Sulfatides/pmc03035524-140-4-14 Average 95 stars, based on 1 article reviews
bovine brain sulfatides - by Bioz Stars,
2026-09
95/100 stars
|
Buy from Supplier |
|
ProSci Incorporated
protein a coupled anticaspase 8 Protein A Coupled Anticaspase 8, supplied by ProSci Incorporated, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sulfatide/SAP+Antibody/pm27050509-213-11-20 Average 90 stars, based on 1 article reviews
protein a coupled anticaspase 8 - by Bioz Stars,
2026-09
90/100 stars
|
Buy from Supplier |
|
Matreya LLC
bovine brain sulfatides Bovine Brain Sulfatides, supplied by Matreya LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sulfatide/bovine+myelin+derived+sulfatide/pmc03743557-145-17-19 Average 90 stars, based on 1 article reviews
bovine brain sulfatides - by Bioz Stars,
2026-09
90/100 stars
|
Buy from Supplier |
|
Matreya LLC
n-palmitoyl-sulfatide N Palmitoyl Sulfatide, supplied by Matreya LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sulfatide/n+palmitoyl+sulfatide/10__1523_slash_jneurosci__3004___10__2011-63-0-4 Average 90 stars, based on 1 article reviews
n-palmitoyl-sulfatide - by Bioz Stars,
2026-09
90/100 stars
|
Buy from Supplier |
|
GelbChem LLC
d5-c16:0 sulfatide D5 C16:0 Sulfatide, supplied by GelbChem LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sulfatide/d5+c16+0+sulfatide/pm35281662-45-59-60 Average 90 stars, based on 1 article reviews
d5-c16:0 sulfatide - by Bioz Stars,
2026-09
90/100 stars
|
Buy from Supplier |
|
Matreya LLC
n-palmitoyl sulfatide (n16:0 sulfatide ![]() N Palmitoyl Sulfatide (N16:0 Sulfatide, supplied by Matreya LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sulfatide/n+palmitoyl+sulfatide+n16+0+sulfatide/pmc03035524-141-0-7 Average 90 stars, based on 1 article reviews
n-palmitoyl sulfatide (n16:0 sulfatide - by Bioz Stars,
2026-09
90/100 stars
|
Buy from Supplier |
|
Nagai Nori USA INC
sulfatides ![]() Sulfatides, supplied by Nagai Nori USA INC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sulfatide/sulfatides/pm09675222-21-8-27 Average 90 stars, based on 1 article reviews
sulfatides - by Bioz Stars,
2026-09
90/100 stars
|
Buy from Supplier |
|
Matreya LLC
sulfatide ![]() Sulfatide, supplied by Matreya LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sulfatide/sulfatide/pm17853408-183-0-5 Average 90 stars, based on 1 article reviews
sulfatide - by Bioz Stars,
2026-09
90/100 stars
|
Buy from Supplier |
|
Matreya LLC
sulfatides ![]() Sulfatides, supplied by Matreya LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sulfatide/sulfatides/pmc02213337-145-7-17 Average 90 stars, based on 1 article reviews
sulfatides - by Bioz Stars,
2026-09
90/100 stars
|
Buy from Supplier |
|
Matreya LLC
sulfatides (c 42 h 80 nnao 11 s, bovine source, ≥98) ![]() Sulfatides (C 42 H 80 Nnao 11 S, Bovine Source, ≥98), supplied by Matreya LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sulfatide/sulfatides++c+42+h+80+nnao+11+s++bovine+source+++98+/pmc05832864-190-0-14 Average 90 stars, based on 1 article reviews
sulfatides (c 42 h 80 nnao 11 s, bovine source, ≥98) - by Bioz Stars,
2026-09
90/100 stars
|
Buy from Supplier |
|
EUROIMMUN
anti-sulfatides igm antibody ![]() Anti Sulfatides Igm Antibody, supplied by EUROIMMUN, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/sulfatide/anti+sulfatides+igm+antibody/pmc11284090-77-13-23 Average 90 stars, based on 1 article reviews
anti-sulfatides igm antibody - by Bioz Stars,
2026-09
90/100 stars
|
Buy from Supplier |
Image Search Results
Journal: Journal of Lipid Research
Article Title: Selective desorption/ionization of sulfatides by MALDI-MS facilitated using 9-aminoacridine as matrix
doi: 10.1194/jlr.D004077
Figure Lengend Snippet: Mass spectral comparison of sulfatide molecular species present in mouse brain cortical lipid extracts acquired by either MALDI-MS or ESI-MS. Lipid extracts of mouse brain cortices were prepared by a modified Bligh and Dyer procedure as described in “Materials and Methods.” A: A negative-ion mass spectrum of a crude lipid extract of mouse brain cortex acquired by MALDI-MS utilizing 9-AA as matrix dissolved in methanol-water solution (90:10, v/v). B: A negative-ion mass spectrum of an alkaline-treated lipid extract of mouse brain cortex acquired by ESI-MS as described in “Materials and Methods.” C: A negative-ion mass spectrum of a crude lipid extract of mouse brain cortex acquired by MALDI-MS utilizing DHB acid as matrix dissolved in water. IS, Internal standard.
Article Snippet:
Techniques: Modification
Journal: Journal of Lipid Research
Article Title: Selective desorption/ionization of sulfatides by MALDI-MS facilitated using 9-aminoacridine as matrix
doi: 10.1194/jlr.D004077
Figure Lengend Snippet: Determination of enhanced desorption/ionization of sulfatides over PI species by MALDI-MS using 9-AA as matrix. Lipid mixtures comprised of N16:0 sulfatide (0.2 pmol/μl) and soy PIs [either 1 pmol/μl (A) or 10 pmol/μl (B)] were prepared and analyzed by MALDI-MS using 9-AA as matrix as described in “Materials and Methods.”
Article Snippet:
Techniques:
Journal: Journal of Lipid Research
Article Title: Selective desorption/ionization of sulfatides by MALDI-MS facilitated using 9-aminoacridine as matrix
doi: 10.1194/jlr.D004077
Figure Lengend Snippet: Product-ion analyses of sulfatide species in the negative ion refl ector mode using 9-AA as matrix. Tandem mass spectra of d18:1-N24:1 sulfatide at m/z 888.67 (A) and d18:1-[OH]N24:0 sulfatide at m/z 906.67 (B) present in mouse brain cortical lipid extracts acquired by MALDI-TOF/TOF-MS in the negative ion mode as described in “Materials and Methods.” Each tandem mass spectrum was recorded on a 4800 MALDI-TOF/TOF Analyzer in the negative ion refl ector mode using 9-AA as matrix using collision-induced dissociation with the metastable suppressor on and the timed ion selector enabled. The voltages of source 1, collision cell, and collision cell offset were 8.0, 7.0, and −0.035 kV, respectively. The tandem mass spectrum was obtained by averaging 3000 consecutive laser shots (50 shots/subspectra with 60 total subspectra).
Article Snippet:
Techniques:
Journal: Journal of Lipid Research
Article Title: Selective desorption/ionization of sulfatides by MALDI-MS facilitated using 9-aminoacridine as matrix
doi: 10.1194/jlr.D004077
Figure Lengend Snippet: Determination of the limit of detection or quantitation of MALDI-MS analysis of sulfatides using 9-AA as matrix. A mixture of N12:0, N16:0, and bovine brain sulfatides at a molar ratio of 1:1:2 was prepared and MALDI-MS analyses of this mixture after dilution were performed as described in “Materials and Methods.” A: A negative-ion mass spectrum of the mixture at a concentration of 200 fmol/μl. B: A negative-ion mass spectrum of the mixture at a concentration of 4 fmol/μl. C: The linear relationship of the ratios of ion peak intensities of representative bovine brain sulfatide species and each of the selected internal standards with different concentrations of the mixture. The data points represent the mean ± SD from four mixture preparations at each concentration. Note that some error bars are within the symbols. IS, Internal standard.
Article Snippet:
Techniques: Quantitation Assay, Concentration Assay
Journal: Journal of Lipid Research
Article Title: Selective desorption/ionization of sulfatides by MALDI-MS facilitated using 9-aminoacridine as matrix
doi: 10.1194/jlr.D004077
Figure Lengend Snippet: Quantitative analyses of sulfatide species by MALDI-MS using 9-AA as matrix. Mixtures comprised of equimolar N12:0 and N16:0 sulfatides as internal standards and different amounts of bovine brain sulfatides were prepared and MALDI-MS analyses of the mixtures after proper dilution were performed as described in “Materials and Methods.” A, B: The negative-ion mass spectra of mixtures at the concentration of 5 and 250 fmol/μl, respectively. C: The linear log correlation between molar ratios and ion peak intensity ratios of representative bovine brain sulfatide species versus both of the selected internal standards. The data points represent the mean ± SD from four mixture preparations of each molar ratio of bovine brain sulfatides to the selected internal standards. Note that some error bars are within the symbols. IS, Internal standard; ST, sulfatide.
Article Snippet:
Techniques: Concentration Assay
Journal: Journal of Lipid Research
Article Title: Selective desorption/ionization of sulfatides by MALDI-MS facilitated using 9-aminoacridine as matrix
doi: 10.1194/jlr.D004077
Figure Lengend Snippet: MALDI-MS mass spectra of sulfatides in lipid extracts of mouse spinal cord, kidney medulla, kidney cortex, and skeletal muscle. Total lipids of spinal cord, kidney medulla, kidney cortex, and skeletal muscle of mice at 4–6 months of age were extracted by using a modifi ed procedure of Bligh and Dyer against 50 mM LiCl as previously described (39). Part of the lipid extract of mouse kidney medulla, kidney cortex, or skeletal muscle was treated with lithium methoxide as previously described (27). MALDI mass spectra of lipid extracts of mouse spinal cord (A), kidney medulla (B), kidney cortex (C), and skeletal muscle (D) were acquired by averaging 3,000 consecutive laser shots (50 shots/subspectra with 60 total subspectra) using the 4800 MALDI TOF/TOF Analyzer with 9-AA as matrix. IS, Internal standard; ST, sulfatide.
Article Snippet:
Techniques:
Journal: Journal of Lipid Research
Article Title: Selective desorption/ionization of sulfatides by MALDI-MS facilitated using 9-aminoacridine as matrix
doi: 10.1194/jlr.D004077
Figure Lengend Snippet: Quantitative analysis of sulfatide species in the lipid extracts from a variety of mouse tissue samples and plasma a
Article Snippet:
Techniques: