reduced-dose ct reconstructed with fbp algorithm using boost 3d Search Results


90
Canon inc fc09 iterative reconstruction
Fc09 Iterative Reconstruction, supplied by Canon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/reduced-dose+ct+reconstructed+with+fbp+algorithm+using+boost+3d/fc09+iterative+reconstruction/pmc06609439-73-14-21
Average 90 stars, based on 1 article reviews
fc09 iterative reconstruction - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
TOSHIBA Medical aidr 3d algorithm
Overview of scan protocols compared in this study
Aidr 3d Algorithm, supplied by TOSHIBA Medical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/reduced-dose+ct+reconstructed+with+fbp+algorithm+using+boost+3d/aidr+3d/pmc05606259-80-13-16
Average 90 stars, based on 1 article reviews
aidr 3d algorithm - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

95
Chem Impex International glycerol
Overview of scan protocols compared in this study
Glycerol, supplied by Chem Impex International, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/reduced-dose+ct+reconstructed+with+fbp+algorithm+using+boost+3d/Glycerol/pmc07842297-62-133-134
Average 95 stars, based on 1 article reviews
glycerol - by Bioz Stars, 2026-11
95/100 stars
  Buy from Supplier

90
Toshiba America Electronic Components Inc aidr 3d ir algorithm
List of experimental and scan parameters.
Aidr 3d Ir Algorithm, supplied by Toshiba America Electronic Components Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/reduced-dose+ct+reconstructed+with+fbp+algorithm+using+boost+3d/aidr/pmc05624940-91-18-17
Average 90 stars, based on 1 article reviews
aidr 3d ir algorithm - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Canon inc enhanced adaptive iterative dose reduction 3d aidr 3d
List of experimental and scan parameters.
Enhanced Adaptive Iterative Dose Reduction 3d Aidr 3d, supplied by Canon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/reduced-dose+ct+reconstructed+with+fbp+algorithm+using+boost+3d/aidr+3d/10__3174_slash_ajnr__a6377-25-30-36
Average 90 stars, based on 1 article reviews
enhanced adaptive iterative dose reduction 3d aidr 3d - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Toshiba America Electronic Components Inc three-dimensional aidr (aidr 3d)
The present reconstruction algorithms applied to coronary imaging.
Three Dimensional Aidr (Aidr 3d), supplied by Toshiba America Electronic Components Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/reduced-dose+ct+reconstructed+with+fbp+algorithm+using+boost+3d/aidr+3d/pmc11598146-98-16-6
Average 90 stars, based on 1 article reviews
three-dimensional aidr (aidr 3d) - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
TOSHIBA Medical sure exposure controls 3d
CT image of module 1 of 40-cm phantom reconstructed with adaptive iterative dose reduction three-dimensional standard mode at tube current time product of 180 mAs, showing alignment line (arrows).
Sure Exposure Controls 3d, supplied by TOSHIBA Medical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/reduced-dose+ct+reconstructed+with+fbp+algorithm+using+boost+3d/sure+exposure+3d+standard/pmc03955785-141-1-16
Average 90 stars, based on 1 article reviews
sure exposure controls 3d - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Toshiba America Electronic Components Inc integrated dose reduction technique sureexposure 3d
CT image of module 1 of 40-cm phantom reconstructed with adaptive iterative dose reduction three-dimensional standard mode at tube current time product of 180 mAs, showing alignment line (arrows).
Integrated Dose Reduction Technique Sureexposure 3d, supplied by Toshiba America Electronic Components Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/reduced-dose+ct+reconstructed+with+fbp+algorithm+using+boost+3d/sureexposure/pmc09238519-106-13-12
Average 90 stars, based on 1 article reviews
integrated dose reduction technique sureexposure 3d - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Siemens Healthineers safire
CT image of module 1 of 40-cm phantom reconstructed with adaptive iterative dose reduction three-dimensional standard mode at tube current time product of 180 mAs, showing alignment line (arrows).
Safire, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/reduced-dose+ct+reconstructed+with+fbp+algorithm+using+boost+3d/safire/pm27013695-14-45-40
Average 90 stars, based on 1 article reviews
safire - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Canon inc hybrid-ir adaptive iterative dose reduction 3d fc08 kernel
CT image of module 1 of 40-cm phantom reconstructed with adaptive iterative dose reduction three-dimensional standard mode at tube current time product of 180 mAs, showing alignment line (arrows).
Hybrid Ir Adaptive Iterative Dose Reduction 3d Fc08 Kernel, supplied by Canon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/reduced-dose+ct+reconstructed+with+fbp+algorithm+using+boost+3d/soft+tissue+kernel/pm39466556-86-7-15
Average 90 stars, based on 1 article reviews
hybrid-ir adaptive iterative dose reduction 3d fc08 kernel - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Siemens AG iterative reconstruction in image space (iris)
CT image of module 1 of 40-cm phantom reconstructed with adaptive iterative dose reduction three-dimensional standard mode at tube current time product of 180 mAs, showing alignment line (arrows).
Iterative Reconstruction In Image Space (Iris), supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/reduced-dose+ct+reconstructed+with+fbp+algorithm+using+boost+3d/iterative+reconstruction+in+image+space++iris+/10__1097_slash_rli__0000000000000172-146-21-30
Average 90 stars, based on 1 article reviews
iterative reconstruction in image space (iris) - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

86
Toshiba America Electronic Components Inc aidr 3d
CT image of module 1 of 40-cm phantom reconstructed with adaptive iterative dose reduction three-dimensional standard mode at tube current time product of 180 mAs, showing alignment line (arrows).
Aidr 3d, supplied by Toshiba America Electronic Components Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/reduced-dose+ct+reconstructed+with+fbp+algorithm+using+boost+3d/3d+aidr+integrated/hoffman_john__2018__characterizing_and_minimizing_the_impacts_of_diagnostic_computed_tomography_acquisition_and_reconstruction-1321-15-14
Average 86 stars, based on 1 article reviews
aidr 3d - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

Image Search Results


Overview of scan protocols compared in this study

Journal: Dentomaxillofacial Radiology

Article Title: Reducing the dose of CT of the paranasal sinuses: potential of an iterative reconstruction algorithm

doi: 10.1259/dmfr.20160127

Figure Lengend Snippet: Overview of scan protocols compared in this study

Article Snippet: The images acquired on the Toshiba CT scanner were generated by using the AIDR 3D algorithm (Toshiba Medical Systems, Otawara, Japan).

Techniques:

List of experimental and scan parameters.

Journal: Journal of Medical Imaging

Article Title: Use of a channelized Hotelling observer to assess CT image quality and optimize dose reduction for iteratively reconstructed images

doi: 10.1117/1.JMI.4.3.031213

Figure Lengend Snippet: List of experimental and scan parameters.

Article Snippet: 8 – 19 Here, we present our investigation on low contrast object detectability in images reconstructed with Toshiba’s AIDR 3D IR algorithm using a channelized Hotelling observer (CHO) model. More specifically, we applied a CHO to determine the amount of dose reduction that is achievable with AIDR 3D while still maintaining equivalent low contrast object conspicuity as that of a full-dose FBP image.

Techniques:

Difference in average, normalized AUC values for the full-dose FBP images and  AIDR   3D  (standard strength) images acquired at different dose levels for each size setting. Associated p -values from two-tailed student t -test are listed from each difference value.

Journal: Journal of Medical Imaging

Article Title: Use of a channelized Hotelling observer to assess CT image quality and optimize dose reduction for iteratively reconstructed images

doi: 10.1117/1.JMI.4.3.031213

Figure Lengend Snippet: Difference in average, normalized AUC values for the full-dose FBP images and AIDR 3D (standard strength) images acquired at different dose levels for each size setting. Associated p -values from two-tailed student t -test are listed from each difference value.

Article Snippet: 8 – 19 Here, we present our investigation on low contrast object detectability in images reconstructed with Toshiba’s AIDR 3D IR algorithm using a channelized Hotelling observer (CHO) model. More specifically, we applied a CHO to determine the amount of dose reduction that is achievable with AIDR 3D while still maintaining equivalent low contrast object conspicuity as that of a full-dose FBP image.

Techniques:

IQ SURE settings for the default protocol and modified protocol.

Journal: Journal of Medical Imaging

Article Title: Use of a channelized Hotelling observer to assess CT image quality and optimize dose reduction for iteratively reconstructed images

doi: 10.1117/1.JMI.4.3.031213

Figure Lengend Snippet: IQ SURE settings for the default protocol and modified protocol.

Article Snippet: 8 – 19 Here, we present our investigation on low contrast object detectability in images reconstructed with Toshiba’s AIDR 3D IR algorithm using a channelized Hotelling observer (CHO) model. More specifically, we applied a CHO to determine the amount of dose reduction that is achievable with AIDR 3D while still maintaining equivalent low contrast object conspicuity as that of a full-dose FBP image.

Techniques: Modification

The present reconstruction algorithms applied to coronary imaging.

Journal: Tomography

Article Title: A Review of Factors Affecting Radiation Dose and Image Quality in Coronary CTA Performed with Wide-Detector CT

doi: 10.3390/tomography10110127

Figure Lengend Snippet: The present reconstruction algorithms applied to coronary imaging.

Article Snippet: The specific details are described below: Toshiba has developed the adaptive dose reduction (AIDR), the three-dimensional AIDR (AIDR 3D), and the forward-projected model-based iterative reconstruction solution (FIRST), of which AIDR 3D is currently routinely configured in all major multi-detector CT scanners from this manufacturer [ ].

Techniques: Imaging

CT image of module 1 of 40-cm phantom reconstructed with adaptive iterative dose reduction three-dimensional standard mode at tube current time product of 180 mAs, showing alignment line (arrows).

Journal: Korean Journal of Radiology

Article Title: Adaptive Iterative Dose Reduction Algorithm in CT: Effect on Image Quality Compared with Filtered Back Projection in Body Phantoms of Different Sizes

doi: 10.3348/kjr.2014.15.2.195

Figure Lengend Snippet: CT image of module 1 of 40-cm phantom reconstructed with adaptive iterative dose reduction three-dimensional standard mode at tube current time product of 180 mAs, showing alignment line (arrows).

Article Snippet: When AIDR 3D is used together with the automatic dose-modulation program ( SURE Exposure controls 3D, Toshiba Medical Systems Corporation), it may simplify the workflow and theoretically it is less concerned with image smoothing together with radiation-dose reduction ( ).

Techniques:

CT images of 40-cm phantom scanned with tube current time product of 180 mAs reconstructed with filtered back projection (A), adaptive iterative dose reduction three-dimensional mild (B), standard (C), and strong modes (D).

Journal: Korean Journal of Radiology

Article Title: Adaptive Iterative Dose Reduction Algorithm in CT: Effect on Image Quality Compared with Filtered Back Projection in Body Phantoms of Different Sizes

doi: 10.3348/kjr.2014.15.2.195

Figure Lengend Snippet: CT images of 40-cm phantom scanned with tube current time product of 180 mAs reconstructed with filtered back projection (A), adaptive iterative dose reduction three-dimensional mild (B), standard (C), and strong modes (D).

Article Snippet: When AIDR 3D is used together with the automatic dose-modulation program ( SURE Exposure controls 3D, Toshiba Medical Systems Corporation), it may simplify the workflow and theoretically it is less concerned with image smoothing together with radiation-dose reduction ( ).

Techniques: