prototype software Search Results


90
Siemens AG prototype software calculating lagrangian strain from deformation field analysis
Prototype Software Calculating Lagrangian Strain From Deformation Field Analysis, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/prototype+software/semi+automatic+prototype+software+calculating+lagrangian+strain+from+deformation+field+analysis/pmc04042354-9-15-18
Average 90 stars, based on 1 article reviews
prototype software calculating lagrangian strain from deformation field analysis - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Siemens AG special prototype software syngo multitechnique workplace
Special Prototype Software Syngo Multitechnique Workplace, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/prototype+software/special+prototype+software+syngo+multitechnique+workplace/10__3174_slash_ajnr__a4497-37-6-19
Average 90 stars, based on 1 article reviews
special prototype software syngo multitechnique workplace - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
MeVIS Research GmbH prototype software program
Prototype Software Program, supplied by MeVIS Research GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/prototype+software/prototype+software/pm29498297-66-5-10
Average 90 stars, based on 1 article reviews
prototype software program - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Siemens AG prototype software
Prototype Software, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/prototype+software/prototype+software/pmc07964758-170-14-16
Average 90 stars, based on 1 article reviews
prototype software - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Siemens AG automated aspects software frontier aspects prototype v2
Workflow of the clinical test, including data collection. Flowchart shows patient selection with criteria and workflow to the clinical test for Heuron <t>ASPECTS</t> evaluation.
Automated Aspects Software Frontier Aspects Prototype V2, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/prototype+software/automated+aspects+software+frontier+aspects+prototype+v2/pmc10804033-76-8-17
Average 90 stars, based on 1 article reviews
automated aspects software frontier aspects prototype v2 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Siemens AG radiomics syngo. via frontier, vision 1.0.0
Workflow of the clinical test, including data collection. Flowchart shows patient selection with criteria and workflow to the clinical test for Heuron <t>ASPECTS</t> evaluation.
Radiomics Syngo. Via Frontier, Vision 1.0.0, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/prototype+software/radiomics+prototype+software+syngo++via+frontier++vision+1+0+0/pmc09815113-161-13-18
Average 90 stars, based on 1 article reviews
radiomics syngo. via frontier, vision 1.0.0 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Siemens AG radiomics prototype software
The workflow in developing a radiomic overall survival nomogram. Computed tomography (CT) and positron emission tomography (PET) images were segmented semiautomatically using the Siemens <t>radiomics</t> prototype. Features including histogram features, shape features, texture features, and wavelet features were extracted from CT and PET images using the software. Three rad-scores were calculated using the least absolute shrinkage and selection operator Cox regression based on subsets of CT, PET, and PET/CT radiomic features. The predictive ability of CT, PET, and PET/CT rad-scores on overall patient survival was evaluated. The overall survival nomogram was constructed based on the PET/CT rad-score and clinicopathological factors.
Radiomics Prototype Software, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/prototype+software/radiomics+prototype+software/pmc07379864-128-24-28
Average 90 stars, based on 1 article reviews
radiomics prototype software - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Optos plc prototype software
The workflow in developing a radiomic overall survival nomogram. Computed tomography (CT) and positron emission tomography (PET) images were segmented semiautomatically using the Siemens <t>radiomics</t> prototype. Features including histogram features, shape features, texture features, and wavelet features were extracted from CT and PET images using the software. Three rad-scores were calculated using the least absolute shrinkage and selection operator Cox regression based on subsets of CT, PET, and PET/CT radiomic features. The predictive ability of CT, PET, and PET/CT rad-scores on overall patient survival was evaluated. The overall survival nomogram was constructed based on the PET/CT rad-score and clinicopathological factors.
Prototype Software, supplied by Optos plc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/prototype+software/prototype+software/pm38724702-68-29-36
Average 90 stars, based on 1 article reviews
prototype software - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
MeVIS Research GmbH cafur software
The workflow in developing a radiomic overall survival nomogram. Computed tomography (CT) and positron emission tomography (PET) images were segmented semiautomatically using the Siemens <t>radiomics</t> prototype. Features including histogram features, shape features, texture features, and wavelet features were extracted from CT and PET images using the software. Three rad-scores were calculated using the least absolute shrinkage and selection operator Cox regression based on subsets of CT, PET, and PET/CT radiomic features. The predictive ability of CT, PET, and PET/CT rad-scores on overall patient survival was evaluated. The overall survival nomogram was constructed based on the PET/CT rad-score and clinicopathological factors.
Cafur Software, supplied by MeVIS Research GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/prototype+software/caipi+prototype+software/pm40554030-126-8-11
Average 90 stars, based on 1 article reviews
cafur software - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Siemens AG syngo through frontier coronary plaque analysis
Selected CTA Automated Quantitative Software Utilizing HU-based AI Algorithms
Syngo Through Frontier Coronary Plaque Analysis, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/prototype+software/software+prototype+coronary+plaque+analysis+2+0+3+syngo+via+frontier/pmc10287054-4-0-7
Average 90 stars, based on 1 article reviews
syngo through frontier coronary plaque analysis - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
EcoDesign Inc ecodesign web-based tool
Selected CTA Automated Quantitative Software Utilizing HU-based AI Algorithms
Ecodesign Web Based Tool, supplied by EcoDesign Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/prototype+software/ecodesign+software+prototyping/10__3390_slash_admsci4030242-337-8-8
Average 90 stars, based on 1 article reviews
ecodesign web-based tool - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
InVisionApp Inc online prototyping software invision
Selected CTA Automated Quantitative Software Utilizing HU-based AI Algorithms
Online Prototyping Software Invision, supplied by InVisionApp Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/prototype+software/online+prototyping+software+invision/pmc06355704-157-3-7
Average 90 stars, based on 1 article reviews
online prototyping software invision - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Workflow of the clinical test, including data collection. Flowchart shows patient selection with criteria and workflow to the clinical test for Heuron ASPECTS evaluation.

Journal: Journal of Neurointerventional Surgery

Article Title: Clinical evaluation of a deep-learning model for automatic scoring of the Alberta stroke program early CT score on non-contrast CT

doi: 10.1136/jnis-2022-019970

Figure Lengend Snippet: Workflow of the clinical test, including data collection. Flowchart shows patient selection with criteria and workflow to the clinical test for Heuron ASPECTS evaluation.

Article Snippet: In the reference study, the agreement between automated ASPECTS software, such as e-ASPECTS, Frontier ASPECTS (prototype v2, Siemens, Germany), and RAPID ASPECTS, was compared with the expert consensus as a reference standard, and it was concluded that reasonable performance was confirmed for all three programs.

Techniques: Selection

The automatic ASPECTS estimation based on the deep-learning model and its performance. (A) progress in estimating the aspects, and (B) output of Heuron ASPECTS. The study results are shown as a Bland–Altman plot (C) of experts’ consensus and Heuron ASPECTS. The mean difference is 0.03, and the upper and lower limits of agreement are 2.80 and −2.74, respectively, satisfying prespecified primary outcomes. (D) The intraclass correlation coefficient (ICC) is 0.78 (95% CI: 0.73 to 0.83), showing good to excellent agreement.

Journal: Journal of Neurointerventional Surgery

Article Title: Clinical evaluation of a deep-learning model for automatic scoring of the Alberta stroke program early CT score on non-contrast CT

doi: 10.1136/jnis-2022-019970

Figure Lengend Snippet: The automatic ASPECTS estimation based on the deep-learning model and its performance. (A) progress in estimating the aspects, and (B) output of Heuron ASPECTS. The study results are shown as a Bland–Altman plot (C) of experts’ consensus and Heuron ASPECTS. The mean difference is 0.03, and the upper and lower limits of agreement are 2.80 and −2.74, respectively, satisfying prespecified primary outcomes. (D) The intraclass correlation coefficient (ICC) is 0.78 (95% CI: 0.73 to 0.83), showing good to excellent agreement.

Article Snippet: In the reference study, the agreement between automated ASPECTS software, such as e-ASPECTS, Frontier ASPECTS (prototype v2, Siemens, Germany), and RAPID ASPECTS, was compared with the expert consensus as a reference standard, and it was concluded that reasonable performance was confirmed for all three programs.

Techniques:

Sensitivity, specificity, and AUC of Heuron  ASPECTS  prediction in comparison with experts’ consensus in each region of interest and dichotomized cut-off points

Journal: Journal of Neurointerventional Surgery

Article Title: Clinical evaluation of a deep-learning model for automatic scoring of the Alberta stroke program early CT score on non-contrast CT

doi: 10.1136/jnis-2022-019970

Figure Lengend Snippet: Sensitivity, specificity, and AUC of Heuron ASPECTS prediction in comparison with experts’ consensus in each region of interest and dichotomized cut-off points

Article Snippet: In the reference study, the agreement between automated ASPECTS software, such as e-ASPECTS, Frontier ASPECTS (prototype v2, Siemens, Germany), and RAPID ASPECTS, was compared with the expert consensus as a reference standard, and it was concluded that reasonable performance was confirmed for all three programs.

Techniques: Comparison

The workflow in developing a radiomic overall survival nomogram. Computed tomography (CT) and positron emission tomography (PET) images were segmented semiautomatically using the Siemens radiomics prototype. Features including histogram features, shape features, texture features, and wavelet features were extracted from CT and PET images using the software. Three rad-scores were calculated using the least absolute shrinkage and selection operator Cox regression based on subsets of CT, PET, and PET/CT radiomic features. The predictive ability of CT, PET, and PET/CT rad-scores on overall patient survival was evaluated. The overall survival nomogram was constructed based on the PET/CT rad-score and clinicopathological factors.

Journal: Frontiers in Oncology

Article Title: Development and Validation of a Radiomics Nomogram Based on 18 F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography and Clinicopathological Factors to Predict the Survival Outcomes of Patients With Non-Small Cell Lung Cancer

doi: 10.3389/fonc.2020.01042

Figure Lengend Snippet: The workflow in developing a radiomic overall survival nomogram. Computed tomography (CT) and positron emission tomography (PET) images were segmented semiautomatically using the Siemens radiomics prototype. Features including histogram features, shape features, texture features, and wavelet features were extracted from CT and PET images using the software. Three rad-scores were calculated using the least absolute shrinkage and selection operator Cox regression based on subsets of CT, PET, and PET/CT radiomic features. The predictive ability of CT, PET, and PET/CT rad-scores on overall patient survival was evaluated. The overall survival nomogram was constructed based on the PET/CT rad-score and clinicopathological factors.

Article Snippet: A volume of interest(VOI)was drawn semiautomatically around the tumor by a chest radiologist (Y.B., 9 years of experience) in the lung diagnosis using the radiomics prototype (Radiomics, Frontier, Siemens) and confirmed by another chest radiologist (W.Q.G., 5 years of experience).

Techniques: Computed Tomography, Positron Emission Tomography, Software, Selection, Positron Emission Tomography-Computed Tomography, Construct

Harrell's concordance index of different modalities.

Journal: Frontiers in Oncology

Article Title: Development and Validation of a Radiomics Nomogram Based on 18 F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography and Clinicopathological Factors to Predict the Survival Outcomes of Patients With Non-Small Cell Lung Cancer

doi: 10.3389/fonc.2020.01042

Figure Lengend Snippet: Harrell's concordance index of different modalities.

Article Snippet: A volume of interest(VOI)was drawn semiautomatically around the tumor by a chest radiologist (Y.B., 9 years of experience) in the lung diagnosis using the radiomics prototype (Radiomics, Frontier, Siemens) and confirmed by another chest radiologist (W.Q.G., 5 years of experience).

Techniques: Biomarker Discovery

Decision curve analysis for each model. The y-axis denotes the net benefit, which was calculated using true-positive and false-positive results. The radiomics nomogram model has the highest net benefit at the threshold from 0.1 to 0.9 among all positive predictions (line labeled “All”), all negative prediction (line labeled “None”), and another 4 clinical models (line labeled “Tumor volume, tumor-node-metastasis [TNM] stage, TNM stage and tumor volume, and clinical model”).

Journal: Frontiers in Oncology

Article Title: Development and Validation of a Radiomics Nomogram Based on 18 F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography and Clinicopathological Factors to Predict the Survival Outcomes of Patients With Non-Small Cell Lung Cancer

doi: 10.3389/fonc.2020.01042

Figure Lengend Snippet: Decision curve analysis for each model. The y-axis denotes the net benefit, which was calculated using true-positive and false-positive results. The radiomics nomogram model has the highest net benefit at the threshold from 0.1 to 0.9 among all positive predictions (line labeled “All”), all negative prediction (line labeled “None”), and another 4 clinical models (line labeled “Tumor volume, tumor-node-metastasis [TNM] stage, TNM stage and tumor volume, and clinical model”).

Article Snippet: A volume of interest(VOI)was drawn semiautomatically around the tumor by a chest radiologist (Y.B., 9 years of experience) in the lung diagnosis using the radiomics prototype (Radiomics, Frontier, Siemens) and confirmed by another chest radiologist (W.Q.G., 5 years of experience).

Techniques: Labeling

Selected CTA Automated Quantitative Software Utilizing HU-based AI Algorithms

Journal: Journal of Thoracic Imaging

Article Title: Computed Tomography Assessment of Coronary Atherosclerosis

doi: 10.1097/RTI.0000000000000711

Figure Lengend Snippet: Selected CTA Automated Quantitative Software Utilizing HU-based AI Algorithms

Article Snippet: Syngo through Frontier Coronary Plaque Analysis , Siemens , Volumetric quantification and differentiation of lipid, fibrous, and calcified plaques , N/A.

Techniques: Software, Diagnostic Assay, Imaging