|
Thermo Fisher
iohexol Iohexol, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/iohexol/product/Thermo Fisher Average 94 stars, based on 1 article reviews
iohexol - by Bioz Stars,
2026-06
94/100 stars
|
Buy from Supplier |
|
Santa Cruz Biotechnology
iohexol Iohexol, supplied by Santa Cruz Biotechnology, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/iohexol/product/Santa Cruz Biotechnology Average 90 stars, based on 1 article reviews
iohexol - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
Toronto Research Chemicals
penta deuterated d5 iohexol internal standard ![]() Penta Deuterated D5 Iohexol Internal Standard, supplied by Toronto Research Chemicals, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/penta deuterated d5 iohexol internal standard/product/Toronto Research Chemicals Average 92 stars, based on 1 article reviews
penta deuterated d5 iohexol internal standard - by Bioz Stars,
2026-06
92/100 stars
|
Buy from Supplier |
|
Toronto Research Chemicals
synthetic iohexol ![]() Synthetic Iohexol, supplied by Toronto Research Chemicals, used in various techniques. Bioz Stars score: 88/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/synthetic iohexol/product/Toronto Research Chemicals Average 88 stars, based on 1 article reviews
synthetic iohexol - by Bioz Stars,
2026-06
88/100 stars
|
Buy from Supplier |
|
SERVA Electrophoresis
nycodenz cushion ![]() Nycodenz Cushion, supplied by SERVA Electrophoresis, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/nycodenz cushion/product/SERVA Electrophoresis Average 90 stars, based on 1 article reviews
nycodenz cushion - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
Axis-Shield Diagnostics
nycodenz ![]() Nycodenz, supplied by Axis-Shield Diagnostics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/nycodenz/product/Axis-Shield Diagnostics Average 90 stars, based on 1 article reviews
nycodenz - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
Serumwerk Bernburg AG
nycodenz ![]() Nycodenz, supplied by Serumwerk Bernburg AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/nycodenz/product/Serumwerk Bernburg AG Average 90 stars, based on 1 article reviews
nycodenz - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
ProteoGenix
nycodenz solution (1.3 g⋅ml -1 ![]() Nycodenz Solution (1.3 G⋅Ml 1, supplied by ProteoGenix, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/nycodenz solution (1.3 g⋅ml -1/product/ProteoGenix Average 90 stars, based on 1 article reviews
nycodenz solution (1.3 g⋅ml -1 - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
Cosmo Bio USA
density-gradient centrifugation with nycodenz tm 1.077 ![]() Density Gradient Centrifugation With Nycodenz Tm 1.077, supplied by Cosmo Bio USA, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/density-gradient centrifugation with nycodenz tm 1.077/product/Cosmo Bio USA Average 90 stars, based on 1 article reviews
density-gradient centrifugation with nycodenz tm 1.077 - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
Oriental Bio Service Kanto Inc
nycodenz gradient ![]() Nycodenz Gradient, supplied by Oriental Bio Service Kanto Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/nycodenz gradient/product/Oriental Bio Service Kanto Inc Average 90 stars, based on 1 article reviews
nycodenz gradient - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
GENTAUR Inc
nicodenz gradient ![]() Nicodenz Gradient, supplied by GENTAUR Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/nicodenz gradient/product/GENTAUR Inc Average 90 stars, based on 1 article reviews
nicodenz gradient - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
Axis-Shield Diagnostics
nycodenz solution ![]() Nycodenz Solution, supplied by Axis-Shield Diagnostics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/nycodenz solution/product/Axis-Shield Diagnostics Average 90 stars, based on 1 article reviews
nycodenz solution - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
Image Search Results
Journal: Physiological Reports
Article Title: Validation of a routine two‐sample iohexol plasma clearance assessment of GFR and an evaluation of common endogenous markers in a rat model of CKD
doi: 10.14814/phy2.13205
Figure Lengend Snippet: Sensitivity and normalization of kidney function measurements. (A–E) Change in trapezoidal plasma clearance of both iohexol and inulin and endogenous biomarkers: plasma creatinine, urea, and cystatin‐C by week of adenine diet‐induced kidney dysfunction. Results analyzed using a repeated measures one‐way ANOVA with post hoc paired T ‐tests with a Tukey correction on the P ‐value comparing each week to week 0 (* P < 0.05, ** P < 0.001, *** P < 0.0001). Error bars show SD . (F–J) The kidney function estimated by inulin plasma clearance as a reference method and the % estimated by the biomarker or iohexol were plotted against each other. An F ‐test was employed to determine whether a straight line or sixth‐order polynomial fit the data better and the result was plotted. Iohexol plasma clearance fit a straight line. Creatinine, urea, and cystatin‐C fit to a sixth‐order polynomial. Gray dotted line indicates inulin plasma clearance plotted against itself – unity.
Article Snippet: Protein precipitation was carried out by adding 100 μ L of 0.2 mol/L zinc sulfate, 450 μ L of methanol, and 1 μ g of
Techniques: Clinical Proteomics, Biomarker Discovery
Journal: Physiological Reports
Article Title: Validation of a routine two‐sample iohexol plasma clearance assessment of GFR and an evaluation of common endogenous markers in a rat model of CKD
doi: 10.14814/phy2.13205
Figure Lengend Snippet: Comparison of inulin and iohexol trapezoidal plasma clearance to simplified one‐compartment model. (A) Plot of inulin plasma clearance as measured by trapezoidal approximation plotted against the one‐compartment model estimation. The gray dotted line indicates unity. (B) Bland–Altman plot of absolute bias of inulin one‐compartment model compared to the reference measure of inulin trapezoidal plasma clearance plotted against the mean of both clearances. The center line indicates the mean bias of −0.57 mL/min with the dotted line indicating the 95% confidence interval or 2 SD (±0.74 mL/min). (C) Plot of iohexol plasma clearance as measured by trapezoidal approximation plotted against the one‐compartment model estimation. The gray dotted line indicates unity. (D) Bland–Altman plot of absolute bias of iohexol one‐compartment model compared to the reference measure of iohexol trapezoidal plasma clearance plotted against the mean of both clearances. The center line indicates the mean bias of −0.02 mL/min with the dotted line indicating the 95% confidence interval or 2 SD (±0.26).
Article Snippet: Protein precipitation was carried out by adding 100 μ L of 0.2 mol/L zinc sulfate, 450 μ L of methanol, and 1 μ g of
Techniques: Comparison, Clinical Proteomics
Journal: Physiological Reports
Article Title: Validation of a routine two‐sample iohexol plasma clearance assessment of GFR and an evaluation of common endogenous markers in a rat model of CKD
doi: 10.14814/phy2.13205
Figure Lengend Snippet: Iohexol plasma clearance calculated by two blood samples at 30 and 90 min. (A) Plot of iohexol two‐sample plasma clearance (30, 90) against the full 12‐sample trapezoidal approximation. The gray dotted line indicates unity. (B) Bland–Altman plot of absolute bias of two‐sample iohexol plasma clearance compared to the reference measure of iohexol trapezoidal plasma clearance plotted against the mean of both clearances. The center line indicates the mean bias of −0.04 mL/min with the dotted line indicating the 95% confidence interval or 2 SD (±0.30 mL/min). (C) Sensitivity of two‐sample iohexol plasma clearance (30, 90) to change by the week of adenine diet‐induced kidney dysfunction. Results analyzed using a one‐way ANOVA with post hoc T ‐tests with a Tukey correction on the P ‐value comparing each week to week 0 (*** P < 0.0001). Error bars show SD.
Article Snippet: Protein precipitation was carried out by adding 100 μ L of 0.2 mol/L zinc sulfate, 450 μ L of methanol, and 1 μ g of
Techniques: Clinical Proteomics
Journal: Physiological Reports
Article Title: Validation of a routine two‐sample iohexol plasma clearance assessment of GFR and an evaluation of common endogenous markers in a rat model of CKD
doi: 10.14814/phy2.13205
Figure Lengend Snippet: Linear regression coefficients, mean bias, precision, and accuracy comparing all plasma clearance measures of both inulin and iohexol
Article Snippet: Protein precipitation was carried out by adding 100 μ L of 0.2 mol/L zinc sulfate, 450 μ L of methanol, and 1 μ g of
Techniques: Clinical Proteomics
Journal: Physiological Reports
Article Title: Validation of a routine two‐sample iohexol plasma clearance assessment of GFR and an evaluation of common endogenous markers in a rat model of CKD
doi: 10.14814/phy2.13205
Figure Lengend Snippet: Two‐sample permutations of iohexol one‐compartment plasma clearance compared to iohexol plasma clearance calculated by trapezoidal, one‐, and two‐compartment models – linear regression coefficients, bias, precision, and accuracy
Article Snippet: Protein precipitation was carried out by adding 100 μ L of 0.2 mol/L zinc sulfate, 450 μ L of methanol, and 1 μ g of
Techniques: Clinical Proteomics