ms modelling ver 4.2 Search Results


97
Shimadzu Corporation shimadzu gcms qp2020nx model gc ms
Shimadzu Gcms Qp2020nx Model Gc Ms, supplied by Shimadzu Corporation, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ms+modelling+ver+4%2E2/GCMS+NX+Series/pmc12932320-219-0-0
Average 97 stars, based on 1 article reviews
shimadzu gcms qp2020nx model gc ms - by Bioz Stars, 2026-09
97/100 stars
  Buy from Supplier

96
Ismatec GmBH multichannel variable speed peristaltic pump
Multichannel Variable Speed Peristaltic Pump, supplied by Ismatec GmBH, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ms+modelling+ver+4%2E2/IPC+Low-Flow+Multichannel+Peristaltic+Pump/pm18965564-53-1-6
Average 96 stars, based on 1 article reviews
multichannel variable speed peristaltic pump - by Bioz Stars, 2026-09
96/100 stars
  Buy from Supplier

90
PCB Piezotronics triaxial accelerometer pcb model vw356a12
a Representative examples of each frequency evaluated are shown with the corresponding power spectra below. Measurements were made using a hydrophone in the same place, where the fish’s head was positioned. b Particle acceleration levels (dB re: 1 ms−2) from the underwater speaker measured in all three dimensions (x-axis = black, y-axis = light grey, z-axis = dark grey) at all frequencies exam-ined for three sound pressure levels: 139, 145, and 151 dB re: 1 µPa. Measurements were made using a triaxial <t>accelerometer</t> in the same place, where the fish’s head was positioned
Triaxial Accelerometer Pcb Model Vw356a12, supplied by PCB Piezotronics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ms+modelling+ver+4%2E2/triaxial+accelerometer+pcb+model+vw356a12/pmc06494099-48-26-31
Average 90 stars, based on 1 article reviews
triaxial accelerometer pcb model vw356a12 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
EKO Instruments Co Ltd pyranometer eko instruments model ms-42
a Representative examples of each frequency evaluated are shown with the corresponding power spectra below. Measurements were made using a hydrophone in the same place, where the fish’s head was positioned. b Particle acceleration levels (dB re: 1 ms−2) from the underwater speaker measured in all three dimensions (x-axis = black, y-axis = light grey, z-axis = dark grey) at all frequencies exam-ined for three sound pressure levels: 139, 145, and 151 dB re: 1 µPa. Measurements were made using a triaxial <t>accelerometer</t> in the same place, where the fish’s head was positioned
Pyranometer Eko Instruments Model Ms 42, supplied by EKO Instruments Co Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ms+modelling+ver+4%2E2/pyrheliometer+ms+54/10__5004_slash_dwt__2009__757-63-20-21
Average 90 stars, based on 1 article reviews
pyranometer eko instruments model ms-42 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
PCB Piezotronics calibrated neutrally buoyant waterproofed triaxial accelerometer pcb model w356a
a Representative examples of each frequency evaluated are shown with the corresponding power spectra below. Measurements were made using a hydrophone in the same place, where the fish’s head was positioned. b Particle acceleration levels (dB re: 1 ms−2) from the underwater speaker measured in all three dimensions (x-axis = black, y-axis = light grey, z-axis = dark grey) at all frequencies exam-ined for three sound pressure levels: 139, 145, and 151 dB re: 1 µPa. Measurements were made using a triaxial <t>accelerometer</t> in the same place, where the fish’s head was positioned
Calibrated Neutrally Buoyant Waterproofed Triaxial Accelerometer Pcb Model W356a, supplied by PCB Piezotronics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ms+modelling+ver+4%2E2/w356+b21+accelerometer/pm33556775-65-26-31
Average 90 stars, based on 1 article reviews
calibrated neutrally buoyant waterproofed triaxial accelerometer pcb model w356a - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

N/A
STK26 HEK293T cell transient overexpression lysate as WB positive control
  Buy from Supplier

N/A
Transient overexpression lysate of thymosin beta 4, Y-linked (TMSB4Y)
  Buy from Supplier

N/A
1-1/2x life size, enlarged. This 1-part model depicts the internal anatomy of the liver with the inferior surface removed. Use this medical-quality piece to teach the form and functions of the liver and gallbladder and
  Buy from Supplier

N/A
Transient overexpression lysate of chromosome 4 open reading frame 44 (C4orf44), transcript variant 1
  Buy from Supplier

N/A
Transient overexpression lysate of microseminoprotein, prostate associated (MSMP)
  Buy from Supplier

N/A
WT1 HEK293T cell transient overexpression lysate as WB positive control
  Buy from Supplier

N/A
MSANTD4 HEK293T cell transient overexpression lysate as WB positive control
  Buy from Supplier

Image Search Results


a Representative examples of each frequency evaluated are shown with the corresponding power spectra below. Measurements were made using a hydrophone in the same place, where the fish’s head was positioned. b Particle acceleration levels (dB re: 1 ms−2) from the underwater speaker measured in all three dimensions (x-axis = black, y-axis = light grey, z-axis = dark grey) at all frequencies exam-ined for three sound pressure levels: 139, 145, and 151 dB re: 1 µPa. Measurements were made using a triaxial accelerometer in the same place, where the fish’s head was positioned

Journal: Journal of comparative physiology. A, Neuroethology, sensory, neural, and behavioral physiology

Article Title: Lagenar potentials of the vocal plainfin midshipman fish, Porichthys notatus

doi: 10.1007/s00359-018-01314-0

Figure Lengend Snippet: a Representative examples of each frequency evaluated are shown with the corresponding power spectra below. Measurements were made using a hydrophone in the same place, where the fish’s head was positioned. b Particle acceleration levels (dB re: 1 ms−2) from the underwater speaker measured in all three dimensions (x-axis = black, y-axis = light grey, z-axis = dark grey) at all frequencies exam-ined for three sound pressure levels: 139, 145, and 151 dB re: 1 µPa. Measurements were made using a triaxial accelerometer in the same place, where the fish’s head was positioned

Article Snippet: Measurements were made using a triaxial accelerometer in the same place, where the fish’s head was positioned Particle acceleration measurements were collected using a neutrally buoyant, triaxial accelerometer [PCB model VW356A12, PCB Piezotronics, Depew, NY, USA; sensitivity at 100 Hz: 10.42 mV/ms −2 ( x -axis), 9.65 mV/ms −2 ( y -axis), 10.14 mV/ms −2 ( z -axis)].

Techniques:

Acoustic characteristics of the experimental tank and speaker. a Acoustic impedance [ratio of sound pressure (dB re: 1 µPa) to particle velocity (dB re: 1 ms−1)] in the z-axis (Z) relative to 1.5597 MRayl (the reference impedance for a free-field in 35 ppt salinity seawater at 15 °C) is plotted for all the frequencies examined at three sound pressure levels: 136, 145, and 151 dB re: 1 µPa. Measurements were made using a triaxial accelerometer placed in the center of the tank and water column. Multiple magnitude measurements (n = 10) for both pressure and particle velocity were made at each frequency and sound pressure level. All data are plotted as the mean ± 1 standard deviation; note that the standard deviations are very small and the standard deviation bars are obscured by the symbols. b Phase difference (Δ) between the pressure and particle velocity wave. Measurements were made using a triaxial accelerometer placed in the center of the tank and water column. Multiple phase difference measurements (n = 10) were made at each frequency and sound pressure level. All data are plotted as the mean ± 1 standard deviation; note that the standard deviations are very small (< 0.3°) and the standard deviation bars are obscured by the symbols

Journal: Journal of comparative physiology. A, Neuroethology, sensory, neural, and behavioral physiology

Article Title: Lagenar potentials of the vocal plainfin midshipman fish, Porichthys notatus

doi: 10.1007/s00359-018-01314-0

Figure Lengend Snippet: Acoustic characteristics of the experimental tank and speaker. a Acoustic impedance [ratio of sound pressure (dB re: 1 µPa) to particle velocity (dB re: 1 ms−1)] in the z-axis (Z) relative to 1.5597 MRayl (the reference impedance for a free-field in 35 ppt salinity seawater at 15 °C) is plotted for all the frequencies examined at three sound pressure levels: 136, 145, and 151 dB re: 1 µPa. Measurements were made using a triaxial accelerometer placed in the center of the tank and water column. Multiple magnitude measurements (n = 10) for both pressure and particle velocity were made at each frequency and sound pressure level. All data are plotted as the mean ± 1 standard deviation; note that the standard deviations are very small and the standard deviation bars are obscured by the symbols. b Phase difference (Δ) between the pressure and particle velocity wave. Measurements were made using a triaxial accelerometer placed in the center of the tank and water column. Multiple phase difference measurements (n = 10) were made at each frequency and sound pressure level. All data are plotted as the mean ± 1 standard deviation; note that the standard deviations are very small (< 0.3°) and the standard deviation bars are obscured by the symbols

Article Snippet: Measurements were made using a triaxial accelerometer in the same place, where the fish’s head was positioned Particle acceleration measurements were collected using a neutrally buoyant, triaxial accelerometer [PCB model VW356A12, PCB Piezotronics, Depew, NY, USA; sensitivity at 100 Hz: 10.42 mV/ms −2 ( x -axis), 9.65 mV/ms −2 ( y -axis), 10.14 mV/ms −2 ( z -axis)].

Techniques: Standard Deviation